首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The study of the metabolic fate of drugs is an essential and important part of the drug development process. The analysis of metabolites is a challenging task and several different analytical methods have been used in these studies. However, after the introduction of the atmospheric pressure ionization (API) technique, electrospray and atmospheric pressure chemical ionization, liquid chromatography/mass spectrometry (LC/MS) has become an important and widely used method in the analysis of metabolites owing to its superior specificity, sensitivity and efficiency. In this paper the feasibility of LC/API-MS techniques in the identification, structure characterization and quantitation of drug metabolites is reviewed. Sample preparation, LC techniques, isotope labeling, suitability of different MS techniques, such as tandem mass spectrometry, and high-resolution MS in drug metabolite analysis, are summarized and discussed. Automation of data acquisition and interpretation, special techniques and possible future trends are also the topics of the review.  相似文献   

2.
With advancements in ionization methods and instrumentation, liquid chromatography/mass spectrometry (LC/MS) has become a powerful technology for the characterization of small molecules and proteins. This article will illustrate the role of LC/MS analysis in drug discovery process. Examples will be given on high-throughput analysis, structural analysis of trace level impurities in drug substances, identification of metabolites, and characterization of therapeutic protein products for process improvement. Some unique MS techniques will also be discussed to demonstrate their effectiveness in facilitating structural identifications.  相似文献   

3.
The requirement for prefractionation in proteomic analysis is linked to the challenge of performing such an analysis on complex biological samples and identifying low level components in the presence of numerous abundant housekeeping and structural proteins. The employment of a preliminary fractionation step results in a reduction of complexity in an individual fraction and permits more complete liquid chromatography/mass spectrometry (LC/MS) analysis. Free flow electrophoresis (FFE), a solution-based preparative isoelectric focusing technique, fractionates and enriches protein fractions according to their charge differences and is orthogonal in selectivity to the popular reversed phase high performance liquid chromatography (HPLC) fractionation step. In this paper, we explored the advantages of a combination of FFE and liquid chromatography/mass spectrometry to extend the dynamic range of a proteomic analysis of a complex cell lysate. In this study, the whole cell lysate of a chronic myelogeneous leukemia cell line, K562/CR3, was prefractionated by FFE into 96 fractions spanning pH 3-12. Of these, 35 fractions were digested with trypsin and then analyzed by LC/MS. Depending on the algorithm used for peptide assignment from MS/MS data, at least 319 proteins were identified through database searches. The results also suggested that pI could serve as an additional criterion besides peptide fragmentation pattern for protein identification, although in some cases, a pI shift might indicate post-translational modification. In summary, this study demonstrated that free flow electrophoresis provided a useful prefractionation step for proteomic analysis and when combined with LC/MS allowed the identification of significant number of low level proteins in complex samples.  相似文献   

4.
Two liquid chromatography mass spectrometric techniques, i.e. ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-Tof MS) and high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS), were used for quantification, confirmation or identification of six macrolide antibiotic residues and/or their degradation products in eggs, raw milk, and/or honey. Macrolides were extracted from food samples by acetonitrile or phosphate buffer (0.1 M, pH 8.0), and sample extracts were further cleaned up using solid-phase extraction cartridges. UPLC/Q-Tof data were acquired in Tof MS full scan mode that allowed both quantification and confirmation of macrolides, and identification of their degradation products. LC/MS/MS data acquisition was achieved using multiple reaction monitoring (MRM), i.e. two transitions, to provide a high degree of sensitivity and repeatability. Matrix-matched standard calibration curves with the use of roxithromycin as an internal standard were utilized to achieve the best accuracy of the method. Both techniques demonstrated good quantitative performance in terms of accuracy and repeatability. LC/MS/MS had advantages over UPLC/Q-Tof MS in that its limits of detection were lower and repeatability was somewhat better. UPLC/Q-Tof provided ultimate and unequivocal confirmation of positive findings, and allowed degradation product identification based on accurate mass. The combination of the two techniques can be very beneficial or complementary in routine analysis of macrolide antibiotic residues and their degradation products in food matrices to ensure the safety of food supply.  相似文献   

5.
Hyphenated mass spectrometric techniques, particularly gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), are indispensable tools in clinical and forensic toxicology and in doping control owing to their high sensitivity and specificity. They are used for screening, library-assisted identification and quantification of drugs, poisons and their metabolites, prerequisites for competent expertise in these fields. In addition, they allow the study of metabolism of new drugs or poisons as a basis for developing screening procedures in biological matrices, most notably in urine, or toxicological risk assessment. Concepts and procedures using GC/MS and LC/MS techniques in the areas of analytical toxicology and the role of mass spectral libraries are presented and discussed in this feature article. Finally, perspectives of their future position are discussed.  相似文献   

6.
This article reviews research on the qualitative and quantitative analysis by high-performance column liquid chromatography/mass spectrometry (LC/MS) and LC/tandem mass spectrometry (LC/MS/MS) of botanical drugs, drug substances or preparations, and finished botanical products. In addition, LC/MS and LC/MS/MS techniques and commercial instruments are described and compared briefly, and prospects for future use of these methods for the analysis of botanicals are suggested. Some applications of direct MS without LC are also described.  相似文献   

7.
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.  相似文献   

8.
Paramethoxyamphetamine (PMA) is an amphetamine-like designer drug that has emerged recently on the European illicit drug market. This drug has a wicked reputation, as a number of lethal intoxications have occurred. A method using high-performance liquid chromatography coupled to ion trap based mass spectrometry (LC/MS) is described for the determination of this compound together with 3,4-methylenedioxymethamphetamine (XTC or MDMA), amphetamine and 3,4-methylenedioxyamphetamine (MDA) in human matrices. A liquid/liquid extraction (LLE) was applied to whole blood, urine and postmortem tissues. Reversed-phase liquid chromatography was performed on a narrow-bore phenyl-type column at a flow rate of 0.3 mL/min. A switch box allowed disposal of early-eluting irrelevant material to waste, protecting the mass spectrometer from contamination. The column effluent was directed into an ion trap mass spectrometer by a sonic spray ionization (SSI) interface. The method was validated for all three matrices, proving the applicability of SSI even when dealing with complex biological matrices. The within-and between-day precisions were less than 17.5% and accuracy was below 16.2%. Weighted (1/x) quadratic calibration curves were generated ranging from 10 to 1000 ng/mL (blood and urine) or 20 to 2000 ng/g (tissue) and correlation coefficients (r(2)) always exceeded 0.995. In addition, the mass spectrum of PMA is given together with a proposed fragmentation pattern for the obtained LC/MS spectrum. This information can be useful for future identification of PMA with LC/MS in biological matrices as well as in confiscated powders or tablets.  相似文献   

9.
A recent trend in the drug discovery and development process is to shift the starting point of drug metabolism and pharmacokinetic (DMPK) studies to a time as early as possible in the development chain to address potential issues in parallel with the optimization of the drug's lead structure. Therefore, it is necessary to develop assay methods to determine early adsorption, distribution, metabolism and excretion (ADME) parameters like metabolic stability and metabolite identification. For metabolite identification it is of crucial importance to work with fast liquid chromatography/mass spectrometry (LC/MS) systems, which provide the necessary high throughput functionalities to handle a large number of samples in combination with high speed and high resolution chromatography as well as mass accuracy. In this study a fast two-column liquid chromatography (LC) method will be used to simultaneously determine metabolic stability and to identify metabolites of buspirone using highly accurate mass measurement by means of an electrospray time-of-flight (ESI-TOF) mass spectrometer. Whereby, the metabolic stability will be determined on a short sub-two micron column, the main metabolites will be identified in the same experiment by the automated use of a long sub-two micron column, which provides the necessary high resolution.  相似文献   

10.
Artemether (ARM), the O-methyl ether prodrug of dihydroartemisinin (DHA), is a first-line antimalarial drug used in areas of multi-drug resistance. Artemisinin drugs can be metabolized extensively in vivo and this seems related to their autoinduction pharmacokinetics. In the present study, the metabolite identification of ARM was performed by the generic data-dependent accurate mass spectrometric analysis, using high-resolution (HR) liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) and tandem mass spectrometry (MS/MS) LTQ-Orbitrap hybrid mass spectrometer in conjunction with online hydrogen (H)/deuterium (D) exchange for rapid structural characterization. The LC separation was improved allowing the separation of ARM parent drugs and their metabolites from their diastereomers. A total of 77 phase I metabolites of ARM were identified in rat liver microsomal incubates and rat urine, including dihydroartemisinin and artemisinin. In rat bile, 12 phase II metabolites were found. Accurate mass data were obtained in both full scan and HR-MS/MS mode to support assignments of metabolite structures. Online H/D exchange LC/HR-ESI-MS experiments provided additional evidence in differentiating dihydroxylated deoxy-ARM from mono-hydroxylated ARM. The results showed the main phase I metabolites of artemether are hydroxylated, dehydro, demethylated and deoxy products, and they will undergo subsequent phase II glucuronidation processes. Most metabolites were reported for the first time. This study also demonstrated the effectiveness of high-resolution mass spectrometry in combination with an online H/D exchange LC/HR-MS(n) technique in rapid identification of drug metabolites.  相似文献   

11.
Today, it is necessary to identify relevant compounds appearing in discovery and development of new drug substances in the pharmaceutical industry. For that purpose, the measurement of accurate molecular mass and empirical formula calculation is very important for structure elucidation in addition to other available analytical methods. In this work, the identification and confirmation of degradation products in a finished dosage form of the antibiotic drug amoxicillin obtained under stress conditions will be demonstrated. Structure elucidation is performed utilizing liquid chromatography (LC) ion trap MS/MS and MS3 together with accurate mass measurement of the molecular ions and of the collision induced dissociation (CID) fragments by liquid chromatography electro spray ionization time-of-flight mass spectrometry (LC/ESI-TOF).  相似文献   

12.
Liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) were applied to characterize drug metabolites. Although these two methods have overcome the identification and structural characterization of metabolites analysis, they remain time‐consuming processes. In this study, a novel multiple‐stage tandem mass spectrometric method (MSn) was evaluated for identification and characterization of new minor metabolism profiling of penicillin G, one of the β‐lactam antibiotics, in human serum. Seven minor metabolites including five phase I metabolites and two phase II metabolites of penicillin G were identified by using data‐dependent LC/MSn screening in one chromatographic run. The accuracy masses of seven identified metabolites of penicillin G were also confirmed by mass spectral calibration software (MassWorks?). The proposed data‐dependent LC/MSn method is a powerful tool to provide large amounts of the necessary structural information to characterize minor metabolite in metabolism profiling. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Methodology is presented for identifying an unknown active (pharmaceutical) ingredient (AI) in a counterfeit drug product. A range of mass spectrometric techniques, i.e., accurate mass mass spectrometry, tandem mass spectrometry (MS/MS) and liquid chromatography/mass spectrometry (LC/MS), has been employed to determine the AI in a counterfeit Halfan suspension, an antimalarial drug. In particular, use of LockSpray accurate mass MS/MS allowed identification of parts of the molecule from fragments, hence limiting the number of possible elemental compositions for the nominal mass of 278 found for the AI in the counterfeit product. The analysis of the isotope pattern observed for the protonated molecule further reduced the number of possible elemental compositions. A literature search for readily commercially available compounds of molecular formula C(12)H(14)N(4)O(2)S suggested that the AI was either sulfamethazine or sulfisomidine. An LC/MS separation of those two compounds and reference MS/MS spectra obtained for sulfamethazine and sulfisomidine led to the conclusion that the AI in the counterfeit Halfan suspension is sulfamethazine, which is an antibacterial agent.  相似文献   

14.
A new approach to obtain fragmentation information in liquid chromatography/mass spectrometry (LC/MS) studies of small molecules in complex mixtures is presented using simultaneous acquisition of exact mass at high and low collision energy, MS(E). LC/MS-TOF and LC/MS/MS-TOF are powerful tools for the analysis of complex mixtures, especially those for biological fluids allowing the elucidation of elemental composition and fragmentation information. In this example the composition of rat urine was studied using this new approach, allowing the structures of several endogenous components to be confirmed in one analytical run by the simultaneous acquisition of exact mass precursor and fragment ion data. The spectral data obtained using this new approach are comparable to those obtained by conventional LC/MS/MS as exemplified by the identification of endogenous metabolites present in rat urine.  相似文献   

15.
Many formulated products contain complex polymeric excipients such as polyethylene glycols (PEGs). Such excipients can be readily ionized by electrospray and may be present at very high concentrations, thus making it very difficult to identify trace level impurities such as degradants in samples, even if hyphenated techniques such as liquid chromatography/mass spectrometry (LC/MS) are used. Ion mobility (IM) spectrometry is a very rapid gas-phase separation technique and offers additional separation capability within the LC timeframe. This work investigates the use of an IM separator in combination with high-pressure liquid chromatography (HPLC) and MS, to improve the separation of drug-related materials from excipients, thus aiding the identification of trace-level impurities in an anti-HIV medication, Combivir.  相似文献   

16.
This paper presents liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) approaches for the rapid characterization of three urinary isomeric metabolites and their two precursor metabolites of SYN-2836, a novel antifungal agent, in dogs administered multiple oral doses of the agent (30 mg kg(-1) day(-1)). A collection of correlative data regarding the SYN-2836 metabolites was obtained by LC/MS and LC/MS/MS performed under complementary conditions such as the columns (C(18) vs cyano type), the mobile phase systems (acetonitrile-water-formic acid vs acetonitrile-water-ammonium acetate) and the electrospray ionization modes (positive vs negative). Metabolite identification was accomplished based on not only the LC/MS/MS data (product ion spectra) but also the LC/MS data indicating chromatographic behaviors of the metabolites. SYN-2836 and SYN-2869, an analog of the former, showed almost the same metabolic pathways following the same multiple-dose administration of the individual agents to the dogs. Therefore, correlation analysis in product ion spectra between corresponding metabolites of SYN-2836 and SYN-2869, and also in metabolic pathways between the two agents, was strategically used to facilitate the identification of the SYN-2836 (and SYN-2869 if necessary) metabolites. For the reason that various elucidation strategies were used complementarily, the chemical structures of the metabolites were unambiguously attained and the isomeric metabolites were explicitly differentiated without the use of other analytical methods. The methodologies used in this study may be applicable to metabolite screening of several structurally related agents simultaneously, promoting lead finding and optimization of drug candidates using a metabolism-based approach.  相似文献   

17.
An emerging trend is recognised in hormone and veterinary drug residue analysis from liquid chromatography tandem mass spectrometry (LC/MS/MS) based screening and confirmation towards accurate mass alternatives such as LC coupled with time-of-flight (TOF), Fourier transform ion cyclotron resonance (FTICR) or Fourier transform orbitrap (FT Orbitrap) MS. In this study, mass resolution and accuracy are discussed for LC/MS screening and confirmation of targeted analytes and for the identification of unknowns using the anabolic steroid stanozolol and the designer beta-agonist "Clenbuterol-R" as model substances. It is shown theoretically and experimentally that mass accuracy criteria without proper mass resolution criteria yield false compliant (false negative) results, both in MS screening and MS/MS confirmation of stanozolol. On the other hand, previous medium resolution accurate mass TOFMS/MS data of the designer beta-agonist were fully confirmed by high resolution FT Orbitrap MS(n) experiments. A discussion is initiated through a proposal for additional criteria for the use of accurate mass LC/MS technologies, to be implemented in Commission Decision 2002/657/EC.  相似文献   

18.
Acceleration of liquid chromatography/mass spectrometric (LC/MS) analysis for metabolite identification critically relies on effective data processing since the rate of data acquisition is much faster than the rate of data mining. The rapid and accurate identification of metabolite peaks from complex LC/MS data is a key component to speeding up the process. Current approaches routinely use selected ion chromatograms that can suffer severely from matrix effects. This paper describes a new method to automatically extract and filter metabolite-related information from LC/MS data obtained at unit mass resolution in the presence of complex biological matrices. This approach is illustrated by LC/MS analysis of the metabolites of verapamil from a rat microsome incubation spiked with biological matrix (bile). MS data were acquired in profile mode on a unit mass resolution triple-quadrupole instrument, externally calibrated using a unique procedure that corrects for both mass axis and mass spectral peak shape to facilitate metabolite identification with high mass accuracy. Through the double-filtering effects of accurate mass and isotope profile, conventional extracted ion chromatograms corresponding to the parent drug (verapamil at m/z 455), demethylated verapamil (m/z 441), and dealkylated verapamil (m/z 291), that contained substantial false-positive peaks, were simplified into chromatograms that are substantially free from matrix interferences. These filtered chromatograms approach what would have been obtained by using a radioactivity detector to detect radio-labeled metabolites of interest.  相似文献   

19.
Hydrophilic interaction chromatography (HILIC) liquid chromatography/mass spectrometry (LC/MS) is appropriate for all native and reductively aminated glycan classes. HILIC carries the advantage that retention times vary predictably according to oligosaccharide composition. Chromatographic conditions are compatible with sensitive and reproducible glycomics analysis of large numbers of samples. The data are extremely useful for quantitative profiling of glycans expressed in biological tissues. With these analytical developments, the rate-limiting factor for widespread use of HILIC LC/MS in glycomics is the analysis of the data. In order to eliminate this problem, a Java-based open source software tool, Manatee, was developed for targeted analysis of HILIC LC/MS glycan datasets. This tool uses user-defined lists of compositions that specify the glycan chemical space in a given biological context. The program accepts high-resolution LC/MS data using the public mzXML format and is capable of processing a large data file in a few minutes on a standard desktop computer. The program allows mining of HILIC LC/MS data with an output compatible with multivariate statistical analysis. It is envisaged that the Manatee tool will complement more computationally intensive LC/MS processing tools based on deconvolution and deisotoping of LC/MS data. The capabilities of the tool were demonstrated using a set of HILIC LC/MS data on organ-specific heparan sulfates.  相似文献   

20.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号