首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Quantification of a mixture of peptides in solution was achieved by disposable patterned hydrophilic chip based matrix-assisted laser desorption/ionization mass spectrometric imaging(MALDI MSI).Compared with other quantitative methods for peptides in solution, this method is label-free and does not require separation of the multiple components of the solution before analysis. Uniform hydrophilic spots and high mass accuracy measurements provided confident identification and quantitative analysis of imaged compounds. The linear correlation between concentration and grayscale of image in the range of 5 fmol/μ L to 1 pmol/μ L was obtained for all four peptides. Good sensitivity and excellent reproducibility were also achieved. The method expands the application of MALDI MSI from tissues to solutions.  相似文献   

2.
In profiling of a specimen by matrix‐assisted laser desorption ionization (MALDI) using a solid matrix, the solvent of the matrix solution extracts an analyte(s). A quantitative profiling cannot be achieved if the solvent evaporates before the complete extraction of the analyte. The extraction can become more quantitative when a liquid matrix dissolved in a solvent is used, which remains a liquid even after the evaporation of the solvent. To check this, radii of an analyte circle (rA), a matrix solution drop (rD) and a liquid matrix (rM) remaining after the solvent evaporation were controlled. Three types of samples were prepared, case A (rA, rD < rM), case B (rD ≤ rM < rA) and case C (rM < rD < rA). In case A, the analyte amount in the matrix layer determined by MALDI was the same as the prepared amount inside the analyte circle. In case B, the analyte amount was the same as the amount inside the matrix circle. Only the analytes in contact with the liquid matrix layer, not more and not less, are transferred to the matrix layer. In case C, the analyte amount was greater than the amount inside the matrix circle, presumably because some of the analyte outside the matrix circle was dissolved by the solvent of the matrix solution. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
4.
Wei LM  Xue Y  Zhou XW  Jin H  Shi Q  Lu HJ  Yang PY 《Talanta》2008,74(5):1363-1370
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a standard analytical tool for protein identification and peptide sequencing. High sensitivity and resolution are two critical parameters for recording good peptide mass fingerprinting (PMF) of low abundance proteins. Here, we report a novel nanodiamond (ND) (normal size 3–10 nm) support for MALDI-MS target, over which -cyano-4-hydrocinnamic acid (CCA) crystallizes evenly. Good reproducibility of relative peak intensity (R.S.D. less than 11.8%) among sample spot (from ring to center) is achieved on ND support. Therefore, the search for “hot spots” during the analysis is not necessary, which is supporting for the automatic acquisition of data. Due to high absorbability of energy from the laser, the ND support improves ionization efficiency of samples. In general, the sensitivity of MS obtained on ND support can be enhanced three to four times compared to the conventional MALDI sample preparation technique. Sensitivity obtained on ND support ranges from 62.5 amol of Arg-vasopressin standard peptide to 1.0 fmol of myoglobin tryptic peptide mixture. Reduced spot size and increased sensitivity in MALDI-MS are also accomplished by ND support. With spot size reduced, the signal intensity of cytochrome c (Cyt c) tryptic peptide obtained on ND support is at least seven times greater than it acquired on stainless steel. And ND support has been found better tolerance for salt (up to 500 mM NaCl) to MALDI-MS analysis. All these properties make ND support a valuable tool for MALDI-MS identification of proteins.  相似文献   

5.
Urine samples from healthy subjects as well as diabetic, nephropathic and diabetic‐nephropathic patients were analyzed by matrix assisted laser desorption/ionization (MALDI) mass spectrometry in order to establish evidence of some possible differences in the peptide profile related to the pathological states. Multivariate analysis suggested the possibility of a distinction among the considered groups of patients. Some differences have been found, in particular, in the relative abundances of three ions at m/z 1912, 1219 and 2049. For these reasons, further investigation was carried out by MALDI/TOF/TOF to determine the sequence of these peptides and, consequently, to individuate their possible origin. By this approach, the peptide at m/z 1912 was found to originate from uromodulin, and its lower expression in the case of nephropathy can be well related to the pathological condition. Ions at m/z 2049 and 1219 originate from the collagen α‐1(I) chain precursor and from the collagen α‐5 (IV) chain precursor, respectively, and, also in this case, their different expressions can be related to the pathologies under investigation. The obtained data seem to indicate that urine is an interesting biological fluid to investigate on the peptide profile and to obtain, consequently, information on the dismetabolism activated by specific pathologies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
We have developed matrix pre‐coated targets for imaging proteins in thin tissue sections by matrix‐assisted laser desorption/ionization mass spectrometry. Gold covered microscope slides were coated with sinapinic acid (SA) in batches in advance and were shown to be stable for over 6 months when kept in the dark. The sample preparation protocol using these SA pre‐coated targets involves treatment with diisopropylethylamine (DIEA)‐H2O vapor, transforming the matrix layer to a viscous ionic liquid. This SA‐DIEA ionic liquid layer extracts proteins and other analytes from tissue sections that are thaw mounted to this target. DIEA is removed by the immersion of the target into diluted acetic acid, allowing SA to co‐crystallize with extracted analytes directly on the target. Ion images (3–70 kDa) of sections of mouse brain and rat kidney at spatial resolution down to 10 µm were obtained. Use of pre‐coated slides greatly reduces sample preparation time for matrix‐assisted laser desorption/ionization imaging while providing high throughput, low cost and high spatial resolution images. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
Overcoming the detrimental effects of sweet spots during crystallization is an important step to improve the quantitative abilities of matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, we introduce MALDI targets, which exhibit a channel design to reduce sweet spot phenomena and improve reproducibility. The size of the channels was 3.0 mm in length, 0.35 mm in depth, and 0.40 mm in width, adjusted to the width of the implemented laser beam. For sample deposition, the matrix/sample mixture was homogenously deposited into the channels using capillary action. To demonstrate the proof‐of‐principle, the novel plates were used for the quantification of acetyl‐L‐carnitine in human blood plasma using a combined standard addition and isotope dilution method. The results showed that the reproducibility of acetyl‐L‐carnitine detection was highly improved over a conventional MALDI‐MS assay, with RSD values of less than 5.9% in comparison with 15.6% using the regular MALDI method. The limits of quantification using the new plates were lowered approximately two‐fold in comparison with a standard rastering approach on a smooth stainless‐steel plate. Matrix effects were also assessed and shown to be negligible. The new assay was subsequently applied to the quantification of acetyl‐L‐carnitine in human plasma samples.  相似文献   

8.
Matrix‐assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a molecular imaging technology uniquely capable of untargeted measurement of proteins, lipids, and metabolites while retaining spatial information about their location in situ. This powerful combination of capabilities has the potential to bring a wealth of knowledge to the field of molecular histology. Translation of this innovative research tool into clinical laboratories requires the development of reliable sample preparation protocols for the analysis of proteins from formalin‐fixed paraffin‐embedded (FFPE) tissues, the standard preservation process in clinical pathology. Although ideal for stained tissue analysis by microscopy, the FFPE process cross‐links, disrupts, or can remove proteins from the tissue, making analysis of the protein content challenging. To date, reported approaches differ widely in process and efficacy. This tutorial presents a strategy derived from systematic testing and optimization of key parameters, for reproducible in situ tryptic digestion of proteins in FFPE tissue and subsequent MALDI IMS analysis. The approach describes a generalized method for FFPE tissues originating from virtually any source.  相似文献   

9.
The application of two-dimensional electrophoresis for the identification of hydrophobic membrane proteins is principally hampered by precipitation of many of these proteins during first-dimension, isoelectric focusing. Therefore new strategies towards the identification and characterization of membrane proteins are being developed. In this work we present a direct and rapid approach from blue-native gels to mass spectrometry, which allows the analyses of complete complexes and prevents protein aggregation of hydrophobic regions during electrophoresis. We combine blue-native gel electrophoresis and liquid chromatography--nanospray-iontrap tandem mass spectrometry to analyze the composition of oxidative phosphorylation complexes I, III, IV and V from bovine-heart mitochondria as a model system containing a number of highly hydrophobic proteins. Bands from blue-native gels were subjected either to in-gel or to in-solution tryptic digestion. The obtained peptide mixtures were further analyzed by liquid chromatography--tandem mass spectrometry and the corresponding proteins were identified by database search. From a total of 86 proteins, 67 protein subunits could be identified including all highly hydrophobic components, except the ND4L and ND6 subunits of complex I. We demonstrate that liquid chromatography--tandem mass spectrometry combined to blue-native electrophoresis is a straightforward tool for proteomic analysis of multiprotein complexes, and especially for the identification of very hydrophobic membrane protein constituents that are not accessible by common isoelectric focusing/sodium dodecyl sulphate gel electrophoresis.  相似文献   

10.
Although the extraction of intact proteins from polyacrylamide gels followed by mass spectrometric molecular mass determination has been shown to be efficient, there is room for alternative approaches. Our study evaluates ethylene glycol diacrylate, a cleavable cross‐linking agent used for a new type of dissolvable gels. It attains an ester linkage that can be hydrolyzed in alkali conditions. The separation performance of the new gel system was tested by 1D and 2D SDS‐PAGE using the outer chloroplast envelope of Pisum sativum as well as a soluble protein fraction of human lymphocytes, respectively. Gel spot staining (CBB), dissolving, and extracting were conducted using a custom‐developed workflow. It includes protein extraction with an ammonia–SDS buffer followed by methanol treatment to remove acrylamide filaments. Necessary purification for MALDI‐TOF analysis was implemented using methanol–chloroform precipitation and perfusion HPLC. Both cleaning procedures were applied to several standard proteins of different molecular weight as well as ‘real’ biological samples (8–75 kDa). The protein amounts, which had to be loaded on the gel to detect a peak in MALDI‐TOF MS, were in the range of 0.1 to 5 μg, and the required amount increased with increasing mass.  相似文献   

11.
A novel method for on-tissue identification of proteins in spatially discrete regions is described using tryptic digestion followed by matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) with MS/MS analysis. IMS is first used to reveal the protein and peptide spatial distribution in a tissue section and then a serial section is robotically spotted with small volumes of trypsin solution to carry out in situ protease digestion. After hydrolysis, 2,5-Dihydroxybenzoic acid (DHB) matrix solution is applied to the digested spots, with subsequent analysis by IMS to reveal the spatial distribution of the various tryptic fragments. Sequence determination of the tryptic fragments is performed using on-tissue MALDI MS/MS analysis directly from the individual digest spots. This protocol enables protein identification directly from tissue while preserving the spatial integrity of the tissue sample. The procedure is demonstrated with the identification of several proteins in the coronal sections of a rat brain.  相似文献   

12.
Although cleavable detergents were first synthesized a number of years ago, they have only recently been successfully applied to problems involving biological molecules. Recent reports have demonstrated that these compounds are useful for applications involving both 2D PAGE and mass spectrometry. However, most cleavable surfactants have utilized acid-labile functional groups to affect cleavage. In applications where extreme pH is required, acid cleavable detergents have limited usefulness. We report the synthesis of fluoride cleavable silane compounds and photolabile cinnamate esters as cleavable detergents having alternative cleavage chemistries than previously reported cleavable detergents. These compounds were applied to whole cell analysis using MALDI mass spectrometry, and it was demonstrated that their use results in an increase in the number of proteins analyzed by increasing protein solubility.  相似文献   

13.
The concentration and size distribution of particles ablated from the infrared matrix‐assisted laser desorption/ionization matrix compounds succinic acid (butanedioic acid), α‐cyano‐4‐hydroxycinnamic acid, and glycerol were measured using an aerodynamic particle sizer combined with a scanning mobility particle sizer. The two sizing instruments together had a sizing range to from 10 nm to 20 µm. Thin layers of the matrix compounds were irradiated with fluences between 6.0 and 9.5 kJ/m2 and wavelengths between 2.8 and 3.0 µm. The distribution of particles was characterized by a large concentration of clusters in the 20‐nm‐diameter range and large component of mass in the range of coarse particle with diameters greater than 1 µm. The wavelength dependence revealed a blue shift for the maximum particle production that is attributed to heating and disruption of the hydrogen bonds in the matrix that shifts the absorption to shorter wavelengths. This blue shift has been observed previously in infrared matrix‐assisted laser desorption/ionization. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
Label-free quantification is a valuable tool for the analysis of differentially expressed proteins identified by mass spectrometry methods.Herein,we used a new strategy:data-dependent acquisition mode identification combined with label-free quantification by SWATH acquisition mode,to study the differentially expressed proteins in mouse liver cancer metastasis cells.A total of 1528 protein groups were identified,among which 1159 protein groups were quantified and 249 protein groups were observed as differentially expressed proteins(86 proteins up-regulated and 163 down-regulated).This method provides a commendable solution for the identification and quantification of differentially expressed proteins in biological samples.  相似文献   

15.
Chromophore effect in the photodissociation of protonated peptides at 266 nm was investigated using synthetic peptides with the sequence RGGXGGGGGR where X was a phenylalanyl(F), tyrosyl(Y), cysteinyl(C), glycyl(G), seryl(S), or histidyl(H) residue. The peptides with an F or Y residue dissociated efficiently. Fragment ions due to cleavages at either end of the chromophore were especially prominent just as for the peptide with a tryptophanyl residue reported previously.1Photodissociation was observed even for the peptides without any noticeable chromophore at 266 nm. Here, dissociation at all the peptide bonds was almost equally prominent. Photodissociation of the protonated angiotensin I was investigated using the spectral correlation rules observed in the model systems. Role of the chromophores and the plausible mechanisms involved are discussed.  相似文献   

16.
17.
Matrix‐assisted laser desorption/ionization (MALDI) ion formation mechanisms were investigated by comparison of isomers of dihydroxybenzoic acid (DHB). These exhibit substantially different MALDI performance, the basis for which was not previously understood. Luminescence decay curves are used here to estimate excited electronic state properties relevant for the coupled chemical and physical dynamics (CPCD) model. With these estimates, the CPCD predictions for relative total ion and analyte ion yields are in good agreement with the data for the DHB isomers. Predictions of a thermal equilibrium model were also compared and found to be incompatible with the data. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
The detection and quantification of nut allergens remains a major challenge. The liquid chroma-tography tandem mass spectrometry (LC-MS/MS) is emerging as one of the most widely used methods, but sample preparation prior to the analysis is still a key issue. The objective of this work was to establish optimized protocols for extraction, tryptic digestion and LC-MS analysis of almond, cashew, hazelnut, peanut, pistachio and walnut samples. Ammonium bicar-bonate/urea extraction (Ambi/urea), SDS buffer extraction (SDS), polyvinylpolypyrroli-done (PVPP) extraction, trichloroacetic acid/acetone extraction (TCA/acetone) and chloro-form/methanol/sodium chloride precipitation (CM/NaCl) as well as the performances of con-ventional tryptic digestion and microwave-assisted breakdown were investigated. Overall, the protein extraction yields ranged from 14.9 ± 0.5 (almond extract from CM/NaCl) to 76.5 ± 1.3% (hazelnut extract from Ambi/urea). Electrophoretic profiling showed that the SDS extraction method clearly presented a high amount of extracted proteins in the range of 0–15 kDa, 15–35 kDa, 35–70 kDa and 70–250 kDa compared to the other methods. The linearity of the LC-MS methods in the range of 0 to 0.4 µg equivalent defatted nut flour was assessed and recovery of internal standards GWGG and DPLNV(d8)LKPR ranged from 80 to 120%. The identified bi-omarkers peptides were used to relatively quantifier selected allergenic protein form the inves-tigated nut samples. Considering the overall results, it can be concluded that SDS buffer allows a better protein extraction from almond, peanut and walnut samples while PVPP buffer is more appropriate for cashew, pistachio and hazelnut samples. It was also found that conventional overnight digestion is indicated for cashew, pistachio and hazelnut samples, while microwave assisted tryptic digestion is recommended for almond, hazelnut and peanut extracts.  相似文献   

19.
张菁  王昊阳  郭寅龙 《中国化学》2005,23(2):185-189
Twenty common amino acids have been analyzed successfully by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) using carbon nanotubes as matrix. From the spectra, little or no background interference or fragmentation of the analytes has been observed. This method was also applied to the analysis of amino acid mixture successfully. Carbon nanotubes have some features such as large surface area to disperse the analyte molecules sufficiently and prevent the sample aggregation and strong ultraviolet absorption to transfer energy easily to the analyte molecules. The present method has potential application for the rapid and sensitive analysis of amino acids and their mixture.  相似文献   

20.
MALDI/FTMS质量校准新方法   总被引:2,自引:1,他引:2  
苏越  陈国强  郭寅龙  相秉仁  安登魁 《化学学报》2004,62(16):1551-1556
在MAIDL/FTMS质量校准中采用 mz =Af +Bf2 模型 ,通过基质峰的测定频率对模型中的参数A ,B进行调整 ,使模型参数更加接近测定状态 ,调整后模型的计算结果明显改善 ;并对多元回归和单纯形法两种建模方法以及单纯形法的目标函数进行了考察 ,结果表明以最大相对误差绝对值为目标函数的单纯形法建立的模型在预测离子质量方面具有较好的稳健性 ,质量测定相对误差均小于 5× 10 -6.用此法分析了克拉霉素的IRMPD质谱裂解规律 ,得到了合理的裂解规律  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号