首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The separation of eight antibiotics belonging to 5‐nitroimidazole family was carried out by means of CEC coupled with MS. Preliminary experiments were carried out with ultraviolet detection in order to select the proper stationary and mobile phase. Among the different stationary phases studied (namely Lichrospher C18, 5 μm particle size; CogentTM Bidentate C18, 4.2 μm; Pinnacle II? Phenyl, 3 μm; Pinnacle II? Cyano, 3 μm), Cogent? Bidentate C18 (4.2 μm) gave the best performance. For CEC‐MS coupling, a laboratory assembled liquid‐junction‐nano‐spray interface was used. In order to achieve a good sensitivity, special attention was paid to both optimization of the sheath liquid composition as well as selection of the injection mode. Under optimized CEC‐ESI‐MS conditions, the separation was accomplished within 22 min by using a column packed with a mixture of Bidentate C18:Lichrospher Silica‐60 (5 μm) 3:1 w/w, an inlet pressure of 11 bar, a voltage of 15 kV, and a mobile phase composed by 45:10:45 v/v/v ACN/MeOH/water containing ammonium acetate (5 mM pH 5). A combined hydrodynamic and electrokinetic injection of 8 bar, 15 kV, and 96 s was adopted. The method was validated in terms of repeatability and intermediate precision of retention times and peak areas, linearity, and LODs and LOQs. RSDs values were <2.9% for retention times and <16.1% for peak areas in both intraday and interday experiments. LOQ values were between 0.09 and 0.42 μg/mL for all compounds. Finally, the method was applied to the determination of three most employed 5‐nitroimidazole antibiotics (metronidazole, secnidazole, and ternidazole) in spiked urine samples, subjected to a SPE procedure. Recovery values in the 67–103% range were obtained. Furthermore, for the selected antibiotics, CEC‐MS2 spectra were obtained providing the unambiguous confirmation of these drugs in urine samples.  相似文献   

2.
A proof‐of‐concept related to the redox‐control of the binding/releasing process in a host–guest system is achieved by designing a neutral and robust Pt‐based redox‐active metallacage involving two extended‐tetrathiafulvalene (exTTF) ligands. When neutral, the cage is able to bind a planar polyaromatic guest (coronene). Remarkably, the chemical or electrochemical oxidation of the host–guest complex leads to the reversible expulsion of the guest outside the cavity, which is assigned to a drastic change of the host–guest interaction mode, illustrating the key role of counteranions along the exchange process. The reversible process is supported by various experimental data (1H NMR spectroscopy, ESI‐FTICR, and spectroelectrochemistry) as well as by in‐depth theoretical calculations performed at the density functional theory (DFT) level.  相似文献   

3.
Kok MG  de Jong GJ  Somsen GW 《Electrophoresis》2011,32(21):3016-3024
Analyte responses in CE‐ESI‐MS using negative ionization are frequently relatively low, thereby limiting sensitivity in metabolomics applications. In order to enhance the ionization efficiency of anionic metabolites, BGEs and sheath liquids (SLs) of various compositions were evaluated. Pressure‐induced infusion and CE‐MS experiments showed that addition of triethylamine (TEA) to the BGE and SL enhanced analyte intensities. A BGE consisting of 25 mM TEA (pH 11.7) and an SL of water–methanol (1:1, v/v) containing 5 mM TEA was selected, providing separation and detection of ten representative test metabolites with good reproducibility (migration time RSDs<1%) and linearity (R2>0.99). This BGE yielded lower limits of detection (0.7–9.1 μM) for most test compounds when compared with common CE‐MS methods using a BGE and SL containing ammonium acetate (NH4Ac) (25 and 5 mM, respectively). CE‐MS of human urine revealed an average amount of 231 molecular features in negative ionization mode when TEA was used in the BGE and SL, whereas 115 and 102 molecular features were found with an NH4Ac‐containing BGE and SL, employing a bare fused‐silica (BFS) and Polybrene‐dextran sulfate‐Polybrene (PB‐DS‐PB)‐coated capillary, respectively. With the CE‐MS method using TEA, about 170 molecular features were observed that were not detected with the NH4Ac‐based CE‐MS methods. For more than 82% of the molecular features that were detected with the TEA as well as the NH4Ac‐containg BGEs (i.e. common features), the peak intensities were higher using TEA with gain factors up to 7. Overall, the results demonstrate that BGEs and SLs containing TEA are quite favorable for the analysis of anionic metabolites in CE‐MS.  相似文献   

4.
Mass spectrometry (MS) is used to quantify the relative distribution of glycans attached to particular protein glycosylation sites (micro‐heterogeneity) and evaluate the molar site occupancy (macro‐heterogeneity) in glycoproteomics. However, the accuracy of MS for such quantitative measurements remains to be clarified. As a key step towards this goal, a panel of related tryptic peptides with and without complex, biantennary, disialylated N‐glycans was chemically synthesised by solid‐phase peptide synthesis. Peptides mimicking those resulting from enzymatic deglycosylation using PNGase F/A and endo D/F/H were synthetically produced, carrying aspartic acid and N‐acetylglucosamine‐linked asparagine residues, respectively, at the glycosylation site. The MS ionisation/detection strengths of these pure, well‐defined and quantified compounds were investigated using various MS ionisation techniques and mass analysers (ESI‐IT, ESI‐Q‐TOF, MALDI‐TOF, ESI/MALDI‐FT‐ICR‐MS). Depending on the ion source/mass analyser, glycopeptides carrying complex‐type N‐glycans exhibited clearly lower signal strengths (10–50% of an unglycosylated peptide) when equimolar amounts were analysed. Less ionisation/detection bias was observed when the glycopeptides were analysed by nano‐ESI and medium‐pressure MALDI. The position of the glycosylation site within the tryptic peptides also influenced the signal response, in particular if detected as singly or doubly charged signals. This is the first study to systematically and quantitatively address and determine MS glycopeptide ionisation/detection strengths to evaluate glycoprotein micro‐heterogeneity and macro‐heterogeneity by label‐free approaches. These data form a much needed knowledge base for accurate quantitative glycoproteomics. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A powerful ionic liquid‐based ultrasonic‐assisted extraction (ILUAE) method combined with ultra‐performance liquid chromatography coupled to electrospray ionization quadrupole time‐of‐flight tandem mass spectrometry (UPLC/ESI‐QTOFMSn) was employed in the rapid simultaneous screening of iridoid glycosides, phenylethanoid glycosides, and cucurbitacin glycosides from P. scrophulariiflora. The ILUAE procedure was optimized over several ultrasonic parameters, including the ultrasonic power, concentration of the ionic liquid, and solid–liquid ratio. A comparison with conventional heat‐reflux extraction and regular UAE demonstrated that the optimized approach yielded a high extraction efficiency (Picroside I, 2.84%; Picroside II, 3.57%; 6‐O‐E‐feruloyl catalpol, 2.20%) within a short extraction time of 30 min. Negative ion mode ESI‐QTOFMS2 analysis of the fragmentation reactions of the [M–H] ions was conducted to characterize the diagnostic ions related to the glycosyl moieties, aglycone units, and the type and substituted position of the ester groups. Interestingly, the positional isomers of the iridoid glycosides could be easily discriminated based on the characteristic ions. A total of 15 glycosides, including three groups of iridoid glycoside isomers and two groups of phenylethanoid glycoside isomers, were conveniently identified within 13.5 min. Moreover, 6'‐O‐vanilloyl catalpol was identified in P. scrophulariiflora for the first time. The method developed here was further validated by measuring the recovery, correlation coefficient (R2), and reproducibility (RSD, n = 5) of three iridoid glycosides: 89.60%–109.02%, 0.9991–0.9998, and 0.93%–1.44%, respectively. This study demonstrated the capabilities of ILUAE combined with UPLC/ESI‐QTOFMSn for the rapid screening of glycosides in P. scrophulariiflora. This method offers an approach to similar studies on other natural plants. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
《Electrophoresis》2017,38(6):914-921
CIEF represents an elegant technique especially for the separation of structural similar analytes, whereas MS is a state‐of‐the‐art instrumentation for the identification and characterization of biomolecules. The combination of both techniques can be realized by hyphenating CIEF with CZE‐ESI‐MS applying a mechanical valve. During the CZE step, the remaining ESI‐interfering components of the CIEF electrolyte are separated from the analytes prior to MS detection. In this work, a multiple heart‐cut approach is presented expanding our previous single heart‐cut concept resulting in a dramatical reduction of analysis time. Moreover, different sample transfer loop volumes are systematically compared and discussed in regard to peak width and transfer efficiency. With this major enhancement, model proteins (1.63–9.75 mg/L), covering a wide pI range (5–10), and charge variants from a deglycosylated model antibody were analyzed on intact level. The promising CIEF‐CZE‐MS setup is expected to be applicable in different bioanalytical fields, e.g. for the fast and information rich characterization of therapeutic antibodies.  相似文献   

7.
In this study, a MIL‐53(Al)‐packed column was successfully prepared and firstly applied to separate phthalate acid esters (butyl benzyl phthalate, di‐n‐butyl phthalate, diethyl phthalate, bis(2‐ethylhexyl) phthalate, and dimethyl phthalate). Their baseline separation could be achieved within 12 min with a mobile phase of methanol/H2O ratio at 92:8, and the temperature and flow rate was 40°C and 0.6 mL/min, respectively. The stacking effect and electrostatic force were the key factors in the separation. Moreover, there was a substantial linear relation between the peak height, peak area, and the analyte mass, and the relative standard deviations of retention time, peak height, peak area, and half peak width for five replicate separations of the analytes were within the ranges 0.31–0.88%, 0.72–1.52%, 1.33–1.53%, and 0.46–0.95%, respectively. The results of the calculation of the thermodynamics parameters showed that the separation of phthalate acid esters was controlled by both enthalpy change (ΔH) and entropy change (ΔS).  相似文献   

8.
In this study, different electrospray ionization mass spectrometric (ESI‐MS) methods were utilized to analyze several pairs of taxane stereoisomers including paclitaxel and 7‐epi‐paclitaxel. Both ESI‐MS and tandem mass spectrometry (MS/MS) techniques provided stereochemically dependent mass spectra in negative‐ion mode, and all studied stereoisomers could be easily distinguished based on their characteristic ions or distinct fragmentation patterns. MS/MS experiments for several taxane analogues at various collision energies were performed to elucidate potential dissociation pathways. The gas‐phase deprotonation potentials were also calculated to estimate the most thermodynamically favorable deprotonation site using DFT B3LYP/6‐31G(d). The results of the theoretical studies agreed well with the fragmentation patterns of paclitaxel and 7‐epi‐paclitaxel observed from MS/MS experiments. In addition, it was found that liquid chromatography (LC)/ESI‐MS was a useful and sensitive technique for assignment of C‐7 taxane stereoisomers from realistic samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Soluble extractives in wood function to protect living trees from destructive agents and also contribute to wood color and fragrance. Some extractive components have biological activities with medical applications. They also play important roles in wood processing and related applications. To increase the knowledge of wood chemistry, maple and oak were extracted by water. Ultraviolet/visible (UV/vis) spectroscopy indicated the presence of a phenolic compound, resorcinol, in maple extractives having higher molecular mass and more aromatic components than oak extractives. Negative and positive electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FT‐ICR‐MS) identified thousands of formulas in the two samples in the m/z range of 200 to 800. They mainly fall into the lignin‐like, carbohydrate‐like, and tannin‐like compound categories. The top 25 peaks (ie, formulas) with the highest relative magnitude in negative ESI represented nearly 50% of the summed total spectral magnitude of all formulas assigned in the maple and oak extractives. Furthermore, the base peak (ie, most abundant peak) accounted for about 14% of the total abundance in each wood sample. Literature comparisons identified 17 of 20 formulas in the top five peaks of the four spectra as specific bioactive compounds in trees and other plants, implying the potential to explore utilization of maple and oak extractives for functional and medicinal applications. The various profiling of the top 25 peaks from the two samples also suggested the possible application of FT‐ICR‐MS for detecting chemical markers useful in profiling and identification of wood types and sources.  相似文献   

10.
The consumption of design drugs, frequently known as new psychoactive substances (NPS), has increased considerably worldwide, becoming a severe issue for the responsible governmental agencies. These illicit substances can be defined as synthetic compounds produced in clandestine laboratories in order to act as analogs of schedule drugs mimetizing its chemical structure and improving its pharmacological effects while hampering the control and making regulation more complicated. In this way, the development of new methodologies for chemical analysis of NPS drugs is indispensable to determine a novel class of drugs arising from the underground market. Therefore, this work shows the use of high‐resolution mass spectrometry Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR MS) applying different ionization sources such as paper spray ionization (PSI) and electrospray ionization (ESI) in the evaluation of miscellaneous of seized drugs samples as blotter paper (n = 79) and tablet (n = 100). Also, an elucidative analysis was performed by ESI(+)MS/MS experiments, and fragmentation mechanisms were proposed to confirm the chemical structure of compounds identified. Besides, the results of ESI(+) and PSI(+)‐FT‐ICR MS were compared with those of GC–MS, revealing that ESI(+)MS showed greater detection efficiency among the methodologies employed in this study. Moreover, this study stands out as a guide for the chemical analysis of NPS drugs, highlighting the differences between the techniques of ESI(+)‐FT‐ICR MS, PSI(+)‐FT‐ICR MS, and GC–MS.  相似文献   

11.
Rapid characterization of metabolites and risk compounds such as chemical residues and natural toxins in raw food materials such as vegetables, meats, and edible living plants and animals plays an important part in ensuing food quality and safety. To rapidly characterize the analytes in raw food materials, it is essential to develop in situ method for directly analyzing raw food materials. In this work, raw food materials including biological tissues and living samples were placed between an electrode and mass spectrometric (MS) inlet under a strong electrostatic field; analytes were rapidly induced to generate electrospray ionization (ESI) from the sample tip by adding a drop of solvent onto the sample. Therefore, the electrostatic field–induced tip‐ESI‐MS allows raw samples to avoid contacting high voltage, and thus this method has the advantage for in vivo analysis of food living plants and animals. Metabolite profiling, residues of pesticides and veterinary drugs, and natural toxins from raw food materials have been successfully detected. The analytical performances, including the linear ranges, sensitivity, and reproducibility, were investigated for direct sample analysis. The ionization mechanism of electrostatic field–induced tip‐ESI was also discussed in this work.  相似文献   

12.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
14.
A sample‐type protein monolayer, that can be a stepping stone to practical devices, can behave as an electrically driven switch. This feat is achieved using a redox protein, cytochrome C (CytC), with its heme shielded from direct contact with the solid‐state electrodes. Ab initio DFT calculations, carried out on the CytC–Au structure, show that the coupling of the heme, the origin of the protein frontier orbitals, to the electrodes is sufficiently weak to prevent Fermi level pinning. Thus, external bias can bring these orbitals in and out of resonance with the electrode. Using a cytochrome C mutant for direct S?Au bonding, approximately 80 % of the Au–CytC–Au junctions show at greater than 0.5 V bias a clear conductance peak, consistent with resonant tunneling. The on–off change persists up to room temperature, demonstrating reversible, bias‐controlled switching of a protein ensemble, which, with its built‐in redundancy, provides a realistic path to protein‐based bioelectronics.  相似文献   

15.
The recent worldwide shortage of acetonitrile has prompted interest in alternative solvents for liquid chromatography/mass spectrometry (LC/MS). In this work, acetone was substituted for acetonitrile in the separation of a peptide mixture by reversed‐phase high‐performance liquid chromatography (RP‐HPLC) and in the positive electrospray ionization mass spectrometry (ESI‐MS) of individual peptides. On both C12 and C18 stationary phases, the substitution of acetone for acetonitrile as the organic component of the mobile phase did not alter the gradient elution order of a five‐peptide retention standard, but did increase peak width, shorten retention times, and increase peak tailing. Positive ESI mass spectra were obtained for angiotensin I, bradykinin, [Leu5]‐enkephalin, and somatostatin 14 dissolved in both acetonitrile/water/formic acid (25%/75%/0.1%) and acetone/water/formic acid (25%/75%/0.1%). Under optimized ESI‐MS conditions, the mass spectral response of [Leu5]‐enkephalin was increased two‐fold when the solvent contained acetone. The substitution of acetone for acetonitrile resulted in only slight changes in the responses of the remaining peptides. A higher capillary voltage was required for optimum response when acetone was used. Compared with acetonitrile/water/formic acid (50/50/0.1%), more interfering species below m/z = 140 were found in the ESI‐MS spectra of acetone/water/formic acid (50/50/0.1%). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Ilaprazole is a new proton pump inhibitor designed for the treatment of gastric ulcers, and limited data is available on the metabolism of the drug. In this article, the structural elucidation of urinary metabolites of ilaprazole in human was described by HPLC‐ESI‐MS/MS and stopped‐flow HPLC‐NMR experiments. Urinary samples were precipitated by sodium carbonate solution, and then extracted by liquid–liquid extraction after adding ammonium acetate buffer solution. The enriched sample was separated using a C18 reversed‐phase column with the mobile phase composed of acetonitrile and 0.05 mol/L ammonium acetate buffer solution in a gradient solution, and then directly coupled to ESI‐MS/MS detection in an on‐line mode or 1H‐NMR (500 MHz) spectroscopic detection in a stopped‐flow mode. As a result, four sulfide metabolites, ilaprazole sulfide (M1), 12‐hydroxy‐ilaprazole sulfide (M2), 11,12‐dihydroxy‐ilaprazole sulfide (M3) and ilaprazole sulfide A (M4), were identified by comparing their MS/MS and NMR data with those of the parent drug and available standard compounds. The main biotransformation reactions of ilaprazole were reduction and the aromatic hydroxylation of the parent drug and its relative metabolites. The result testified that HPLC‐ESI‐MS/MS and HPLC‐NMR could be widely applied in detection and identification of novel metabolites. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
Electrospray ionization mass spectrometry (ESI‐MS) is very often employed to study metal/ligand equilibria in aqueous solution. However, the ionization process can introduce perturbations which affect the speciation results in an unpredictable way. It is necessary to identify these perturbations in order to correctly interpret the ESI‐MS speciation results. Aluminium(III)/1,6‐dimethyl‐4‐hydroxy‐3‐pyridinecarboxylate (DQ716) aqueous solutions at various pH were analysed by ESI‐MS, and speciation results were compared with those obtained by equilibrium techniques. Differences observed were both qualitative and quantitative. The ESI‐MS spectral changes due to different settings of the following instrumental parameters were analyzed: the solution flow rate (FS), the nebulizer gas flow rate (FG), the potential applied at the entrance capillary (EC), and the temperature of the drying gas (TG). The effects produced by FS and EC on the spectra strongly suggest the key role of surface activity in determining the relative fraction of the ions reaching the detector. The experimental effects of FS and TG were interpreted considering the presence of at least two reactions in the gas phase and a dimerization occurring in the droplets. These perturbations cannot be generalized because they appear to be chemical system‐related and instrument‐dependent. Therefore, the identification of perturbations is a required task for any metal‐ligand equilibrium study performed by ESI‐MS. Our results indicate that perturbations can be identified by evaluating the effects produced in the spectra by a change of instrumental parameters. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run‐to‐run and batch‐to‐batch reproducibility (RSD of migration time ≤0.5% for run‐to‐run and ≤9.5% for batch‐to‐batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI‐MS for analysing complex samples, such as peptides, whereas the overall performance of the CE‐MALDI‐MS system was investigated by analysing a five‐protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss‐Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS.  相似文献   

19.
《Electrophoresis》2018,39(7):998-1005
In the first part of this publication, the results from an international study evaluating the precision (i.e., repeatability and reproducibility) of N‐glycosylation analysis using capillary electrophoresis of APTS‐labeled N‐glycans were presented. The corresponding results from ultra‐high performance liquid chromatography (UHPLC) with fluorescence detection are presented here from 12 participating sites. All participants used the same lot of samples, reagents, and columns to perform the assays. Elution time, peak area and peak area percent values were determined for all peaks ≥0.1% peak area, and statistical analysis was performed following ISO 5725‐2 guideline principles. The results demonstrated adequate reproducibility, within any given site as well across all sites, indicating that standard UHPLC‐based N‐glycan analysis platforms are appropriate for general use.  相似文献   

20.
Ultra high‐performance liquid chromatography (UHPLC) with evaporative light scattering detection was used for the quantification of steroidal saponins and diosgenin from the rhizomes or tubers of various Dioscorea species and dietary supplements that were purported to contain Dioscorea. The analysis was performed on an Acquity UPLC? system with an UPLC? BEH Shield RP18 column using a gradient elution with water and acetonitrile. Owing to their low UV absorption, the steroidal saponins were observed by evaporative light scattering detection. The 12 compounds could be separated within 15 min using the developed UHPLC method with detection limits of 5–12 µg/mL with 2 μL injection volume. The analytical method was validated for linearity, repeatability, accuracy, limits of detection and limits of quantification. The relative standard deviations for intra‐ and inter‐day experiments were <3.1%, and the recovery efficiency was 97–101%. The total content of standard compounds was found to be in the ranges 0.01–14.5% and 0.9–28.6 mg daily intake for dry plant materials and solid commercial preparations, respectively. UHPLC–mass spectrometry with a quadrupole mass analyzer and ESI source was used only for confirmation of the identity of the various saponins. The developed method is simple, rapid and especially suitable for quality control analysis of commercial products. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号