首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The potential of capillaries noncovalently coated with a bilayer of oppositely charged polymers for the analysis of peptides by CE-MS was investigated. Bilayer coatings were produced by subsequently rinsing fused-silica capillaries with a solution of Polybrene (PB) and poly(vinyl sulfonate) (PVS). The PB-PVS coating showed to be fully compatible with MS detection causing no ionization suppression or background signals. The bilayer coating provided a considerable EOF at low pH, thereby facilitating the fast separation of peptides using a BGE of formic acid (pH 2.5). Under optimized CE-MS conditions, for enkephalin peptides high separation efficiencies were obtained with plate numbers in the range of 300,000-500,000. It is demonstrated that both the cancellation of the hydrodynamic capillary flow induced by the nebulizer gas and a sufficiently high-data acquisition rate are crucial for achieving these efficiencies. The overall performance of the CE-MS system using PB-PVS-coated capillaries was evaluated by the analysis of a tryptic digest of cytochrome c. The system provided an efficient separation of the peptide mixture, which could be effectively monitored by MS/MS detection allowing identification of at least 13 peptides within a time interval of 1.5 min. In addition, the PB-PVS coating proved to be very consistent yielding stable CE-MS patterns with highly favorable migration time reproducibilities (RSDs < 1% over a 3-day period).  相似文献   

2.
The usefulness of a noncovalent capillary coating consisting of two layers of oppositely charged polymers for the separation of peptides with capillary electrophoresis (CE) was studied. Capillaries were coated simply by subsequently flushing with solutions of 1% m/v Polybrene and 1% v/v poly(vinylsulfonate) (PVS) forming a bilayer, which showed to produce a strong and highly reproducible electroosmotic flow (EOF) at low pH. Using this coating in combination with a background electrolyte (BGE) containing sodium phosphate (pH 2.5) and 0.01% v/v PVS, initially broadened and overlapping peaks were obtained for some test peptides. By omitting the PVS from the BGE, the peak width and shape of the peptides improved resulting in baseline separation. A systematic study of the influence of the BGE composition showed that considerable further enhancement of the separation efficiency was achieved by increasing the ionic strength of the BGE. Using a BGE of 200 mM tris(hydroxymethyl)aminomethane (Tris)-phosphate (pH 2.5) plate numbers for the peptides were in the 300 000-600 000 range and the relative standard deviation of the peptide migration times was less then 0.3% (n = 5). The use of Tris-phosphate instead of sodium phosphate allowed the current to stay within acceptable limits when 30 kV was used as separation voltage. Overall, the bilayer coating showed a remarkable EOF repeatability, as well as long-term stability. Compared to bare fused-silica capillaries the intraday and interday repeatability of migration times was very favorable and coated capillaries could be used for over a month performing analyses with low and high ionic strength BGEs without any performance deterioration. The usefulness of the bilayer-coated capillaries for the analysis of positively charged peptides was demonstrated by the fast and efficient separation of various closely related enkephalins and the baseline separation of an isomeric peptide/peptoid couple exhibiting efficiencies of over 550 000 plates.  相似文献   

3.
A novel positively charged polymer of quaternary ammonium substituted agarose (Q-agarose) has been synthesized and explored for use as a coating in capillary electrophoresis. The fast and simple coating procedure is based on a multi-site electrostatic interaction between the polycationic agarose polymer and the negatively charged fused-silica surface. By simply flushing fused-silica capillaries with hot polymer solution a positively charged, hydrophilic deactivation layer is achieved. The polymer surface provides an intermediate electroosmotic flow of reversed direction, over a range of pH 2-11, compared to unmodified fused-silica. The coating procedure was highly reproducible with an RSD of 4%, evaluated as the electroosmotic flow mobility for 30 capillaries prepared at 10 different occasions. The application of Q-agarose coated capillaries in separation science was investigated using a set of basic drugs and model proteins and peptides. Due to the intermediate electroosmotic flow generated, the resolution of basic drugs could be increased, compared to using bare fused-silica capillaries. Moreover, the coating enabled separation of proteins and peptides with efficiencies up to 300.000 plates m(-1).  相似文献   

4.
Mora MF  García CD 《Electrophoresis》2007,28(8):1197-1203
This paper reports a simple procedure for coating fused-silica capillaries with poly(diallyldimethyl ammonium chloride) and montmorillonite. The coated capillaries were characterized by performing EOF measurements as a function of buffer pH, number of layers of coating, and number of runs (stability). The coated capillaries showed a highly stable mu(EOF) (run-to-run RSD less than 1.5%, n = 20), allowing continuous use for several days without conditioning. The coated capillaries were then used for the effective separation of nine environmentally important phenolic compounds showing a significant improvement in the resolution, when compared to bare fused-silica capillaries. The EOF of the coated capillaries was constant in alkaline solutions (pH > or = 7), allowing the optimization of the separation conditions of phenolic compounds without significantly affecting the mu(EOF).  相似文献   

5.
A capillary electrophoresis-time of flight-mass spectrometry (CE-TOF-MS) method for the analysis of amino acids in human urine was developed. Capillaries noncovalently coated with a bilayer of Polybrene (PB) and poly(vinyl sulfonate) (PVS) provided a considerable EOF at low pH, thus facilitating the fast separation of amino acids using a BGE of 1 M formic acid (pH 1.8). The PB-PVS coating proved to be very consistent yielding stable CE-MS patterns of amino acids in urine with favorable migration time repeatability (RSDs <2%). The relatively low sample loading capacity of CE was circumvented by an in-capillary preconcentration step based on pH-mediated stacking allowing 100-nL sample injection (i.e. ca. 4% of capillary volume). As a result, LODs for amino acids were down to 20 nM while achieving satisfactory separation efficiencies. Preliminary validation of the method with urine samples showed good linear responses for the amino acids (R(2) >0.99), and RSDs for peak areas were <10%. Special attention was paid to the influence of matrix effects on the quantification of amino acids. The magnitude of ion suppression by the matrix was similar for different urine samples. The CE-TOF-MS method was used for the analysis of urine samples of patients with urinary tract infection (UTI). Concentrations of a subset of amino acids were determined and compared with concentrations in urine of healthy controls. Furthermore, partial least squares-discriminant analysis (PLS-DA) of the CE-TOF-MS dataset in the 50-450 m/z region showed a distinctive grouping of the UTI samples and the control samples. Examination of score and loadings plot revealed a number of compounds, including phenylalanine, to be responsible for grouping of the samples. Thus, the CE-TOF-MS method shows good potential for the screening of body fluids based on the analysis of endogenous low-molecular weight metabolites such as amino acids and related compounds.  相似文献   

6.
Shou CQ  Zhou CL  Zhao CB  Zhang ZL  Li GB  Chen LR 《Talanta》2004,63(4):887-891
A series of hyperbranched poly(amine-ester)s based on 1,1,1-trimethylolpropane, methyl acrylate and diethanolamine were synthesized and coated on the inner surface of the fused-silica capillaries by physical adsorption. The most effective coating was the seventh generation hyperbranched poly(amine-ester) coating, which reduced the electroosmotic flow (EOF) greatly and suppressed protein adsorption effectively. The high separation efficiencies for basic proteins were obtained and the coating had a good stability.  相似文献   

7.
To simplify capillary electrophoresis-mass spectrometry (CE-MS) operation, a background electrolyte (BGE) containing a polymer additive is introduced that allows the analysis of peptides and protein mixtures in underivatized fused-silica capillaries without any pretreatment, thereby increasing throughput. The most important characteristic of these polymer additives is that they do not significantly suppress the signals of the proteins and peptides under electrospray ionization, thereby allowing them to be used as an additive to common BGEs that are used for CE-MS analysis of peptide and protein mixtures. In addition, because the fused-silica capillary inner wall is continuously coated with the polymer additive, migration irreproducibility, due to the degradation of the capillary inner wall coating, under CE-MS is minimized. High sensitivity of detection, migration reproducibility, and ease of fabrication allow CE-MS analyses that require long analysis time, such as (CE-MS/MS)n, to be performed with ease. The utility of this background electrolyte has been demonstrated for the analysis of complex protein digests and intact proteins.  相似文献   

8.
The paper reports the results of a study carried out to evaluate the use of three 1‐alkyl‐3‐methylimidazolium‐based ionic liquids as non‐covalent coating agents for bare fused‐silica capillaries and additives of the electrolyte solutions (BGE) for CE of basic proteins in the co‐EOF separation mode. The three ionic liquids are differentiated from each other by the length of the alkyl group on the imidazolium cation, consisting of either an ethyl, butyl or octyl substituent, whereas tetrafluoroborate is the common anionic component of the ionic liquids. Coating the capillary with the ionic liquid resulted in improved peak shape and protein separation, while the EOF was maintained cathodic. This indicates that each ionic liquid is effective at masking the protein interaction sites on the inner surface of the capillary, also when its adsorption onto the capillary wall has not completely neutralized all the negative charges arising from the ionization of the silanol groups and the ionic liquid is not incorporated into the BGE employed for separation. Using the coated capillaries with BGE containing the ionic liquid employed for the coating, at concentration low enough to maintaining the EOF cathodic, both peak shape and protein separation varied to different extents, based on the particular ionic liquid used and its concentration. Fast and efficient separation of the model basic protein mixture in co‐electroosmotic CE is obtained with the 1‐butyl‐3‐methylimidazolium tetrafluoroborate coated capillary and 100 mM acetate buffer (pH 4.0) containing 4.4 mM 1‐butyl‐3‐methylimidazolium tetrafluoroborate as the BGE.  相似文献   

9.
10.
The usefulness of a noncovalent, positively charged capillary coating for the efficient analysis of intact basic proteins with CE was studied. Capillaries were coated by subsequent flushing with solutions of 10% w/v Polybrene (PB), 3% w/v dextran sulfate (DS), and again 10% w/v PB. Coating characterization studies showed that stable coatings could be produced which exhibited a pH‐independent and highly reproducible EOF. The PB–DS–PB coating was evaluated with Tris phosphate BGEs of various pH using the four basic model proteins: α‐chymotrypsinogen A, ribonuclease A, cytochrome c, and lysozyme. Typical migration time RSDs for the proteins were less than 0.85%, and apparent plate numbers were above 125 000 using a capillary length of 40 cm. The high separation efficiency allowed detection of several minor impurities in the model proteins. Using a BGE of medium pH, the CE system with triple‐layer coating appeared to be useful for the repeatable profiling of recombinant humanized mouse monoclonal immunoglobulin G1 showing a characteristic pattern of glycoforms. The CE system was also applied to the characterization of two llama antibodies, which were produced in Saccharomyces cerevisiae, revealing the presence of a side product in one of the antibodies. The high migration time stability allowed the reliable determination of antibody–antigen binding by monitoring migration time shifts. Finally, the feasibility of using the PB–DS–PB coated capillaries for CE with mass spectrometric detection was shown by the characterization of the impure llama antibody sample.  相似文献   

11.
Anionic liposomes can be coated on fused-silica capillaries for electrophoresis in the presence of N-(hydroxyethyl)piperazine-N'-(2-ethanesulfonic acid) (HEPES) as background electrolyte (BGE) solution. In this work, the interaction of various compounds with zwitterionic and anionic phospholipid coatings was studied with HEPES at pH 7.4 as BGE solution. The chromatographic and electrophoretic behavior of three test sample solutions (anionic, cationic, and neutral) was investigated for evaluation of the phospholipid coatings. Our results show that hydrophobic interactions between analytes and the phospholipid coating are important for the migration of charged analytes. In addition, the performances of other piperazine-based buffers, i.e., N-(2-hydroxyethyl)piperazine-N'-(2-hydroxypropanesulfonic acid), piperazine-N,N'-bis(2-ethanesulfonic acid), and piperazine-N,N'-bis(hydroxypropane sulfonic acid), at pH 7.4, as liposome solvent and BGE solution were evaluated and compared with the performance of HEPES at pH 7.4. The anionic liposome solution comprised 80/20 mol% phosphatidylcholine/phosphatidylserine. A simple test solution was selected and the chromatographic and electrophoretic migration behavior of the analytes was evaluated. The results show that, in addition to HEPES, other piperazine-based buffers at pH 7.4 are suitable for coating of fused-silica capillaries with anionic liposomes.  相似文献   

12.
分别合成了以三羟甲基丙烷和季戊四醇为核的超支化聚(胺-酯),并对其进行了红外测定、羟值测定、粘度测定等表征。采用化学键合方法将其涂于毛细管内壁,并测定涂层柱的电渗流以及对碱性蛋白质的分离能力,结果表明,涂层柱能有效地抑制碱性蛋白质在毛细管内壁上的吸附,大大降低电渗流;以三羟甲基丙烷为核的超支化聚(胺-酯)涂层柱的塔板数达105/m,而以季戊四醇为核的超支化聚(胺-酯)涂层柱的分离柱效更高,塔板数达107/m。实验结果表明这两类涂层柱都具有较好的分离效果和稳定性。  相似文献   

13.
A new application of the polymeric ionic liquid (PIL) in capillary electrophoresis is reported. Poly(1-vinyl-3-butylimidazolium bromide) was physically adsorbed on silica capillary as the simple and effective coating for capillary electrophoresis (CE) analysis, in which the PIL is not present in the background electrolyte. The electroosmotic flow (EOF) of the PIL-coated capillary as compared with that of the bare fused-silica capillary shows a different dependence on electrolyte pH values. The EOF is reversed over a wide pH range from 3.0 to 9.0 and shows good repeatability. It is also found that the coated capillary has a good tolerance to some organic solvents, 0.1 M NaOH and 0.1 M HCl. The PIL-coated capillary has been employed in different areas. Both the basic proteins and anionic analytes can be well separated by PIL-coated capillaries in a fast and easy way. The PIL-coated capillary is also able to separate organic acid additives in a grape juice. The results showed that this type of coating provides an alternative to the CE separation of anions and basic proteins.  相似文献   

14.
Capillary isoelectric focusing (CIEF) separations are usually performed with neutral coated fused-silica capillaries in aqueous anticonvective media. Glycerol, a very viscous solvent (eta = 945 mPa x s at 25 degrees C), known to help stabilize any kind of proteins and solubilize hydrophobic ones, was tested as an alternative to using commercial gels. Viscosity and electroosmotic mobility were measured as a function of gel or glycerol content in water, and a 30:70 v/v glycerol-water medium appeared as a good compromise for performing CIEF in a bare fused-silica capillary without imposing too high a viscosity. To demonstrate the feasibility of this new CIEF system, a standard mixture of nine model proteins was separated according to their pI with a good agreement between experimental and literature aqueous pIs. Moreover, better resolution was achieved with this system than with the conventional aqueous CIEF system, as two of the model proteins could not be separated in the latter system. Glycerol-water CIEF in bare silica capillary was next applied to the separation of horse radish peroxidase, a complex mixture of protein isoforms. The good concordance with the separation obtained by the conventional CIEF system indicated the adequacy of this new system. Finally, as anticipated from the results obtained for the separation of bacteriorhodopsin, a membrane protein, glycerol-water CIEF performed in bare silica capillary appears to be a promising alternative to conventional aqueous CIEF for hydrophobic protein characterization, under their native form.  相似文献   

15.
The surface chemistry of the inner wall of fused-silica capillaries is one important means to control the magnitude as well as the direction of the electroosmotic flow and the adsorption activity. A method was developed to change the surface characteristics of fused-silica capillaries by binding tentacle-like oligourethane groups onto the inner surface. The electroosmotic flow at a buffer pH of 6-9 was reduced by 15 to 40% compared to that in a bare fused-silica tubing, dependent on the type of coating. Sample adsorption is diminished at the same time resulting in a separation of proteins with higher resolution and good migration time precision. At a pH below 4.5 the electroosmotic flow is reversed into the anodic direction, which offers further possibilities for the separation of positively charged analytes as demonstrated for the separation of aromatic and biogenic amines.  相似文献   

16.
The separation of 17 “common” underivatized amino acids was attempted by open tubular capillary electrochromatography (OT-CEC) in fused-silica capillaries coated with Rh(III) tetrakis(phenoxyphenyl)porphyrinate (Rh(III)TPP(m-OPh)4OAc) using sodium phosphate and Tris–phosphate buffers as background electrolytes (BGEs). The OT-CEC separation of amino acids was compared with that obtained by capillary zone electrophoresis in bare fused-silica capillaries using the same BGEs. The amino acids were not derivatized and the UV-absorption detection was set at 200 nm. Depending on the experimental conditions at least 15 amino acids were separated. The best separations were obtained in a Rh(III)TPP(m-OPh)4OAc-coated capillary in 50 mM Tris–100 mM phosphate buffer at pH 2.25. Separation of the critical triplet Val–Ile–Leu was always at least indicated being better at higher BGE concentrations. Regarding the sensitivity of the method, lower concentration limits of detection (LODs) in the coated capillary were obtained for Thr, Gly, Tyr, and Val; the other amino acids exhibited lower LODs in the uncoated capillary. The separation of acidic amino acids was not achieved.  相似文献   

17.
A capillary electrophoresis-mass spectrometry (CE-MS) method using sheath liquid electrospray ionization interfacing was studied and optimized for the analysis of intact basic proteins. To prevent protein adsorption, capillaries with a noncovalent positively charged coating were utilized. Capillaries were coated by subsequent rinsing with solutions of Polybrene, dextran sulfate and Polybrene. The coating proved to be fully compatible with MS detection, causing no background signals and ionization suppression. The composition of the sheath liquid and BGE was optimized using the model proteins α-chymotrypsinogen A, ribonuclease A, lysozyme and cytochrome c. A sheath liquid of isopropanol-water-acetic acid (75:25:0.1, v/v/v) at 2 μL min−1 resulted in optimal signal intensities for most proteins, but caused dissociation of the heme group of cytochrome c. Optimum protein responses were obtained with a BGE of 50 mM acetic acid (pH 3.0), which allowed a baseline separation of the test protein mixture. Several minor impurities present in the mixture could be detected and provisionally identified using accurate mass and a protein modification database. The selectivity of the CE-MS system was investigated by the analysis of acetylated lysozyme. Eight highly related species, identified as non-acetylated lysozyme and lysozyme acetylated in various degrees, could be distinguished. The CE-MS system showed good reproducibility yielding interday (three weeks period) RSDs for migration time and peak area within 2% and 10%, respectively. With the CE-MS system, determination coefficients (R2) for protein concentration and peak area were higher than 0.996, whereas detection limits were between 11 and 19 nM.  相似文献   

18.
The effect of pH on the formation and stability of phospholipid coatings in fused-silica capillaries in electrophoresis was investigated. A liposome solution consisting of 3 mM of 80:20 mol% phosphatidylcholine/phosphatidylserine (PC/PS) in N-(2-hydroxyethyl)piperazine-N'-(2-ethanesulfonic acid) (HEPES) buffer was used as coating material. The coating was prepared by a method described earlier and five steroids were used as neutral model analytes. First, the effect of pH of the coating solution on the formation and stability of phospholipid coatings was studied at pH 6.5-8.5. The pH of the background electrolyte (BGE) solution (HEPES) was either kept constant at pH 7.4 or made similar to the pH of the liposome coating solution. Results showed that attachment of the coating on the fused-silica wall mostly depends on the protonation of amines of the phospholipids and HEPES. The ability of the phospholipid coating to withstand changes in pH was then investigated by coating at pH 7.5 and separating steroids with acetic acid, 3-(cyclohexylamino)-1-propanesulfonic acid (CAPS), HEPES, or glycine BGE, adjusted to pH between 4.5 and 10.8. The results showed that with use of BGE solution at pH 10.8, the separation of steroids was not successful and the electroosmotic flow was high because of leakage of the phospholipid coating during preconditioning of the capillary with BGE solution. There was no phospholipid leakage with a BGE solution of pH 4.5, indicating that the protonated form of the functional groups of PS and HEPES participating in the attachment of the phospholipid coating to the capillary play an essential role in the success of the coating.  相似文献   

19.
DNA oligonucleotides that form G-quartet structures were used as stationary phase reagents for separation of bovine milk proteins, including alpha-casein, beta-casein, kappa-casein, alpha-lactalbumin and beta-lactoglobulin. Both artificial protein mixtures and a skim milk sample were analyzed. The separations were performed using open-tubular capillary electrochromatography, in which the oligonucleotides were covalently attached to the inner surface of a fused-silica capillary. Better resolution was achieved using the G-quartet-coated capillaries than was achieved using either a bare capillary or a capillary coated with an oligonucleotide that does not form a G-quartet structure. A 4-plane G-quartet-forming stationary phase was able to resolve three peaks for alpha-casein and to detect thermal denaturation of the proteins in the milk sample. The results suggest that G-quartet stationary phases could be used to separate very similar protein structures, such as those arising from genetic variations or post-translational modifications.  相似文献   

20.
Liu H  Shi R  Wan W  Yang R  Wang Y 《Electrophoresis》2008,29(13):2812-2819
A series of well-defined diblock copolymers, poly(ethylene oxide)-block-poly(4-vinylpyridine) (PEO-b-P4VP) used as physical coating of capillaries, were synthesized by atom transfer radical polymerization (ATRP). EOF measurement results showed that all synthesized PEO-b-P4VP diblock copolymer-coated capillaries in this report could suppress EOF effectively compared to the bare fused-silica capillaries, and efficient separations of basic proteins were achieved. The effects of the molecular weight of P4VP block in PEO-b-P4VP and buffer pH on the separation of basic proteins for CE were investigated in detail. Moreover, the relationships between morphologies of PEO-b-P4VP diblock copolymers in buffer, which were studied by transmission electron microscopy, and the separation efficiencies of basic protein with PEO-b-P4VP diblock copolymers coatings were discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号