首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
Frank C. Calvosa 《Talanta》2010,80(3):1116-6727
The extraction of polybrominated diphenyl ethers (PBDEs) from SRM 2585 (Organic Contaminants in House Dust) was investigated using supercritical fluid R134a as an extraction solvent. Three methods of dust extraction were studied: (1) extraction of dry dust, (2) extraction of dry dust dispersed on Ottawa sand and (3) extraction of dust wet with dichloromethane. For each of the three sample preparation methods, extracts at three temperatures (110, 150, and 200 °C) above the critical temperature of R134a were performed. Eight PBDE congeners (BDE-28, -47, -99, 100, -153, -154, -183, and -209) in the SFE extracts were analyzed by liquid chromatography negative-ion atmospheric pressure photoionization tandem mass spectrometry (LC/NI-APPI/MS/MS). The optimum extraction of PBDEs from house dust using supercritical R134a is obtained when the dust is pre-wet with dichloromethane prior to extraction to swell the dust. For all sample preparation methods, higher temperatures afforded higher percent recoveries of the eight PBDE congeners. Only a combination of high-temperature (200 °C) and pre-wetting the dust with dichloromethane produced high recovery of the environmentally important, fully brominated PBDE congener, BDE-209.  相似文献   

2.
张晓玲  王炳玲  陆晓梅  张琦  张正东 《色谱》2012,30(12):1241-1245
建立了室内灰尘样品中8种常见多溴联苯醚(PBDEs: BDE-28、BDE-47、BDE-99、BDE-100、BDE-153、BDE-154、BDE-183和BDE-209)的气相色谱-负化学电离源质谱(GC-NCI/MS)分析方法。样品经吸尘器采集、正己烷超声萃取、浓缩后,采用GC-NCI/MS测定。结果表明,方法的加标回收率为53.2%~107.6%,日内测定的相对标准偏差(RSD)为2.8%~16.5%,日间测定的RSD为6.4%~22.6%。除了BDE-209的检出限(信噪比为3)为0.15 ng/g外,其他多溴联苯醚的检出限为0.003~0.015 ng/g。该方法灵敏度高,准确度和精密度好,简便快速,溶剂消耗量少,适用于灰尘中三溴~十溴联苯醚的测定。  相似文献   

3.
We describe the development of a liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometric (LC/NI-APPI/MS/MS) method for the simultaneous determination of tetrabromobisphenol A (TBBP-A) and five polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100, BDE-153 and BDE-154) in water. A mobile phase methanol/acetone/water was used, where acetone acts also as dopant. NI-APPI produced precursor ions corresponding to [M−H] for TBBP-A, [M−Br+O], and [M−2Br+O] for the BDE congeners studied. Each compound was quantified operating in multiple reaction monitoring mode. Linearity was observed in the range 0.025–10 ng injected for all compounds. Coefficients of determination R2 ranged from 0.9934 to 0.9982. BDEs were poorly retained by solid-phase extraction (SPE) from river water and sewage treatment plant effluent, thus liquid–liquid extraction (LLE) by n-hexane should be used for these samples. The recoveries of TBBP-A and PBDEs from tap water (SPE), river water and industrial wastewater (LLE) were in the range of 81–88%, 78–92%, and 43–99%, respectively, with relative standard deviations below 17%. The limits of detection, based on signal-to-noise ratio of 3, ranged from 0.004 to 0.1 ng injected, and method quantification limits were 0.2–3.3 ng L−1 but BDE47 (20.3 ng L−1). Only TBBP-A was found in a treated industrial sewage at 4 ng L−1, while BDE-99 and BDE-100 were detected on suspended solids.  相似文献   

4.
超声辅助萃取气相色谱-质谱法测定松针中的多溴联苯醚   总被引:3,自引:0,他引:3  
陈长二  赵洪霞  谢晴  陈景文 《色谱》2009,27(1):59-62
建立了测定松针样品中多溴联苯醚(PBDEs)的分析方法。松针样品经过正己烷-丙酮(体积比为1∶1)混合溶液超声萃取、浓硫酸和氧化铝柱净化后,采用气相色谱-负化学电离源质谱(GC-NCI-MS)选择离子监测(SIM)模式检测,内标法定量。结果表明,方法的加标回收率为83.8%~107.5%,三溴~七溴代联苯醚的仪器检出限为0.152~ 0.770 pg,十溴代联苯醚(BDE-209)的检出限为11.1 pg;三溴~七溴代联苯醚的方法检出限(湿重)为3~15 pg/g,BDE-209的方法检出限(湿重)为222 pg/g。方法具有良好的重现性、较高的灵敏度和良好的回收率。实际样品分析表明,松针中BDE-209是主要的同类物,约占8种PBDEs总量的82.3%,低溴代联苯醚以2,2′,4,4′-四溴联苯醚(BDE-47)为主。  相似文献   

5.
Two new HPTLC methods for quantification of isopropyl-9H-thioxanthen-9-one (ITX) in milk, yoghurt and fat samples have been developed. Extraction of ITX from milk and yoghurt was performed with a mixture of cyclohexane and ethyl acetate by employment of accelerated solvent extraction (ASE). For soy bean oil and margarine, a simple partitioning of ITX into acetonitrile was used. ITX and 2,4-diethyl-9H-thioxanthen-9-one (DTX) used as internal standard have been separated on silica gel 60 HPTLC plates with a mixture of toluene and n-hexane (4:1, v/v) and on RP18 HPTLC plates with a mixture of acetonitrile and water (9:1, v/v). Development was performed anti-parallel from both plate sides leading to a throughput of 36 separations in 7 min. Fluorescence measurement at 254/>400 nm was used for quantification. Limits of detection (S/N of 3) have been established to be 64 pg for ITX and DTX on both types of HPTLC plates. In fatty matrix (spiked butter) LOD of ITX was determined to be 1 μg kg−1. In the working range monitored (20–200 μg kg−1) polynomial regression of ITX showed a relative standard deviation (sdv) of ±1.51 % (r=0.99981). Starting with the limit of quantification the response was linear (sdv=±2.18 %, r=0.99893). Regarding repeatability (n=9) a coefficient of variation (CV) of 1.1 % was obtained for ITX at 32 ng on silica gel plates and of 2.9 % on reversed-phase plates. Repeatabilities (n=4) of ITX determination at 20, 50 and 100 μg kg−1 in milk, yoghurt, soybean oil and margarine showed CVs between ±1.0 and 6.4 %. The results prove that modern planar chromatography is a rapid and cost-efficient alternative method to quantify ITX in milk-based or fatty matrices. Only positive results are confirmed by online ESI/MS in the SIM mode (LOQ 128 pg) and by DART/MS involving a minimal employment of the MS device, which is a further advantage of HPTLC. Overall mean recovery rates of ITX at 20 or 50 and 100 μg kg−1 (n=8) were 41 % for milk, 70 % for yoghurt, 6 % for margarine and 12 % for soy bean oil. However, with the internal standard correction recoveries were about 130 % for milk and yoghurt and 70 and 97 % for margarine and soy bean oil, respectively.   相似文献   

6.
Qian Luo  Minghung Wong  Zongwei Cai   《Talanta》2007,72(5):1644-1649
Analytical method using mass spectrometric techniques was applied for the determination of polybrominated diphenyl ethers (PBDEs) in freshwater fishes. Fish samples collected from Nanyang River contaminated by the recycling electron-wastes (e-wastes) materials were prepared by using Soxhlet extraction and multiple-step column chromatographic clean-up. PBDEs were determined by gas chromatography (GC) coupled with ion trap mass spectrometry (for mono- to hepta-BDEs) and quadrupole mass spectrometry (for BDE-209). The method performance was evaluated with the recovery of 13C-labeled internal standards and with the analysis of certified reference biota. The obtained recoveries ranged from 75 to 125% with a relative standard deviation of lower than 10% for 16 PBDE congeners. The total PBDE (ΣPBDE) concentrations in fishes showed the following trend: grass carp < mud carp < crucian carp < silver carp < carp. ΣPBDE concentrations in the abdomen, back and tail muscles of carp ranged from 766, 458 and 530 ng/g w.w., and 53, 52, 45 ng/g w.w. in grass carp, respectively. The ΣPBDE concentrations in abdomen muscles were no significantly higher than in back and tail muscles in carp, crucian carp, grass carp and mud carp. PBDE congener concentrations in muscles correlated well with their lipid content. BDE-47 and BDE-28 were the most abundant congeners followed by BDE-17, BDE-15, BDE-66, BDE-154 and BDE-153 in fishes collected from Guiyu.  相似文献   

7.
Gas chromatographic analysis of polybrominated diphenyl ethers (PBDEs) has been evaluated in an attempt to achieve better control of the separation process, especially for highly substituted congeners. Use of a narrow-bore capillary column enabled adequate determination of tetra, penta, hexa, hepta, octa, nona and decaBDE congeners in only one chromatographic run while maintaining resolution power similar to that of conventional columns. A micro electron-capture detector (GC–μECD) was used. Chromatographic conditions were optimized by multifactorial experimental design, with the objective of obtaining not only high sensitivity but also good precision. In this way two different approaches to maximizing response and minimizing variability were tested, and are fully discussed. These optimum chromatographic conditions were then used to determine PBDEs extracted from domestic dust samples by microwave-assisted solvent extraction (MASE). Quantitative recovery (90–108%) was achieved for all the PBDEs and method precision (RSD < 13%) was satisfactory. Accuracy was tested by use of the standard reference material SRM 2585, and sub-ng g−1 limits of detection were obtained for all compounds except BDE-209 (1.44 ng g−1). Finally, several samples of house dust were analysed by use of the proposed method and all the target PBDEs were detected in all the samples. BDE-209 was the predominant congener. Amounts varied from 58 to 1615 ng g−1 and the average contribution to the total PBDE burden of 52%. The main congeners of the octaBDE mixture (BDE-183, BDE-197, BDE-207 and BDE-196) also made an important contribution (29%) to the total. These are the first data about the presence of these compounds in European house-dust samples. Finally, the sum of the main congeners in the pentaBDE commercial mixture (BDE-47, BDE-99, and BDE-100) contributed 14% to the total. Figure Polybrominated diphenyl ethers in House Dust  相似文献   

8.
A rapid and sensitive high‐performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated to quantify tilmicosin in pig plasma. Plasma samples were prepared by liquid–liquid extraction. Chromatographic separation was achieved on a C18 column (2.1 × 30 mm, 3.5 μm) using acetonitrile–water (90:10, v /v; water included 0.1% formic acid) as the mobile phase. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear from 0.5 to 2000 ng/mL (r 2 = 0.9998). The intra‐ and inter‐day accuracy and precision were within the acceptable limits of ±10% for all tilmicosin concentrations. The recoveries ranged from 95 to 99% for the three tested concentrations. The LC–MS/MS method described herein was simple, fast and less laborious than other methods, achieved high sensitivity using a small sample volume, and was successfully applied to pharmacokinetic studies of tilmicosin enteric granules after oral delivery to pigs. In comparison with tilmicosin premix, tilmicosin enteric granules slowed the elimination rate of tilmicosin, prolonged its period of action and significantly improved its bioavailability.  相似文献   

9.
A rapid and reliable analytical method based on pressurised solvent extraction (PSE) and GC-NCI-MS was developed for the determination of 41 different PBDEs in soil. All PBDEs, including mono- to hepta-BDEs (sum of 39 congeners), one nona-BDE and deca-BDE, were efficiently extracted from soil samples using the extraction technology of PSE. The extract was then cleaned up on a florisil column. Satisfactory separation of 41 PBDE congeners was obtained on a 15-m DB-5MS capillary column, saving the use of another 30-m column specific for the separation of mono- to hepta-BDEs. PBDEs were identified and quantified by GC-MS in negative chemical ionisation (NCI) mode, and further confirmed in semi electron impact (SEI) mode when the ion source was also NCI. The method detection limits ranged from 0.01 to 0.03?ng?g?1?dw for mono- to hepta-BDEs, 1.43?ng?g?1?dw for the nona-BDE and 0.20?ng?g?1?dw for deca-BDE. The applicability of the method was tested in soil samples collected from an e-waste recycling site at Guiyu. Twenty-one PBDEs (mono- to deca-) were detected, and eighteen congeners were quantified. The concentration range of PBDEs was 0.78–436?ng?g?1?dw. BDE-47, BDE-99, BDE-153, BDE-183, BDE-206 and BDE-209 were the dominant congeners, and BDE-209 accounted for 62% of the total PBDEs. The congener profiles of PBDEs in soil samples were similar to those in three commercial PBDE products (Penta-, Octa- and Deca-BDE), and Deca-BDE product was the most important contributor.  相似文献   

10.
A robust, specific and fully validated LC‐MS/MS method as per general practices of industry has been developed for estimation of lacidipine (LAC) with 100 μL of human plasma using lacidipine‐13C8 as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode. A simple liquid–liquid extraction process was used to extract LAC and IS from human plasma. The total run time was 3.0 min and the elution of LAC and IS occurred at 1.96 and 1.97 min; this was achieved with a mobile phase consisting of 5 mm ammonium acetate buffer–acetontrile (15:85 v/v) at a flow rate of 0.60 mL/min on a Zorbax SB C18 (50 × 4.6 mm, 5 µm) column. A linear response function was established for the range of concentrations 50–15,000 pg/mL (r > 0.998) for LAC. The current developed method has negligible matrix effect and is free from unwanted adducts and clusters which are formed owing to system such as solvent or mobile phase. The developed assay method was applied to an oral pharmacokinetic study in humans and successfully characterized the pharmacokinetic data up to 72 h. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

12.
将超声辅助碱液分解杂质与溶剂萃取相结合,采用气相色谱-电子捕获检测(GC-ECD)建立了一种快速高效净化、萃取海洋沉积物中8种常见多溴联苯醚(PBDEs)的分析方法。样品在2.00 mol/L NaOH甲醇溶液中超声30 min,经正己烷萃取、单层硅胶净化、正己烷洗脱、旋蒸浓缩后定容至100 μL,采用GC-ECD分析。结果表明,PBDEs各单体的加标回收率为63.6%~110.3%,相对标准偏差(RSD)为1.7%~15.5%(n=5);十溴联苯醚(BDE-209)的检出限为0.097 ng/g,其他7种单体的检出限为0.002~0.011 ng/g(信噪比为3)。该方法的准确度和精密度较高,稳定性和回收率良好,可满足沉积物中PBDEs的分析要求。利用建立的方法测定了渤海表层沉积物中PBDEs的含量,8种PBDEs总含量在1.566~6.760 ng/g之间,其中BDE-209的含量为1.461~6.438 ng/g,总体呈现出由近岸向远岸递减的趋势,表明人为活动、表层冲刷和陆地河流的输入对渤海地区PBDEs的含量有重要影响。  相似文献   

13.
An ultra-sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the analysis of oral contraceptive ethinyl estradiol (EE) was developed and validated over the curve range of 2.5-500 pg/mL using 1 mL of human plasma sample. Ethinyl estradiol and the internal standard, ethinyl estradiol tetra-deuterated (EE-d4), were extracted from the plasma matrix with methyl t-butyl ether, derivatized with dansyl chloride and then back-extracted into hexane. The hexane phase was evaporated to dryness, reconstituted and injected onto the LC/MS/MS system. The chromatographic separation was achieved on a Luna C(18) column (50 x 2 mm, 5 micro m) with an isocratic mobile phase of 20:80 (v/v) water:acetonitrile with 1% formic acid. The offline derivatization procedure introduced the easily ionizable tertiary amine function group to EE. This greatly improved analyte sensitivity in electrospray ionization and enabled us to achieve the desired lower limit of quantitation at 2.5 pg/mL. This high sensitivity method can be used for therapeutic drug monitoring or supporting bio-equivalence and drug-drug interaction studies in human subjects.  相似文献   

14.
Shi Z  Wang Y  Feng J  Huang P  Wu Y 《色谱》2011,29(6):543-548
建立了凝胶渗透色谱(GPC)结合气相色谱-负化学源质谱(GC-NCI/MS)检测鱼肉及鱼油中8种多溴联苯醚(PBDEs)同系物及2种得克隆阻燃剂(DP)的分析方法。试样中加入内标物BDE-77和13C12-BDE-209后进行索氏提取,提取液经自动GPC系统除脂,多层硅胶层析柱净化后,在15 m长的毛细管气相色谱柱上分离,NCI/MS以选择离子监测方式检测目标化合物。以鱼肉样品为基质,当PBDEs的加标水平为0.2 ng/g和2 ng/g、BDE-209和DP的加标水平相应提高10倍时,其平均加标回收率为71.1%~121.4%,相对标准偏差为2.96%~13.31%(n=5);以信噪比(S/N)为3计算方法的检出限(LOD)为2.2~39.8 ng/kg。用该方法检测市售鱼肉及鱼油样品,其中多溴联苯醚总含量为2.18~15.93 ng/g,以BDE-209、BDE-47为主,两种DP均未检出。该方法准确、灵敏度高,能够满足富含脂质的动物性样品中痕量DP和PBDEs残留的分析要求。  相似文献   

15.
建立了凝胶渗透色谱(GPC)结合气相色谱-负化学源质谱(GC-NCI/MS)检测鱼肉及鱼油中8种多溴联苯醚(PBDEs)同系物及2种得克隆阻燃剂(DP)的分析方法。试样中加入内标物BDE-77和13C12-BDE-209后进行索氏提取,提取液经自动GPC系统除脂,多层硅胶层析柱净化后,在15 m长的毛细管气相色谱柱上分离,NCI/MS以选择离子监测方式检测目标化合物。以鱼肉样品为基质,当PBDEs的加标水平为0.2 ng/g和2 ng/g、BDE-209和DP的加标水平相应提高10倍时,其平均加标回收率为71.1%~121.4%,相对标准偏差为2.96%~13.31%(n=5);以信噪比(S/N)为3计算方法的检出限(LOD)为2.2~39.8 ng/kg。用该方法检测市售鱼肉及鱼油样品,其中多溴联苯醚总含量为2.18~15.93 ng/g,以BDE-209、BDE-47为主,两种DP均未检出。该方法准确、灵敏度高,能够满足富含脂质的动物性样品中痕量DP和PBDEs残留的分析要求。  相似文献   

16.
A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol–water–formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H]+ m/z 483.3 for heteroclitin D and [M + H]+ m/z 629.3 for the IS. The standard curve was linear (R2 ≥0.995) over the concentration range 9.98–2080 ng/mL and had good back‐calculated accuracy and precision. The intra‐ and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and –8.9–3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague–Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
An analytical method was developed and tested for four different groups of veterinary antibiotics in both river water and sediment matrices. Solid phase extraction (SPE) was used to enrich and to clean up the aqueous sample. Also, Mcllvaine and ammonium hydroxide buffer solutions were used to extract the compounds from the sediment matrix. High performance liquid chromatography (HPLC) equipped with tandem mass spectrometry (MS/MS) was used to separate and quantify the samples. The range of recoveries (in percent) for tetracyclines (TCs), sulfonamides (SAs), macrolides (MLs), and ionophore polyethers (IPs) in the water matrix were 102.2–124.8, 76.6–124.3, 89.5–114.7, 82.7–117.5 with 1–13 (%) of relative standard deviation respectively with three different concentrations. For sediment, the percent recovery ranges were 32.8–114.8, 62.4–108.9, 53.4–128.4 and 51.3–105.4 for TCs, SAs, MLs and IPs, respectively. The relative standard deviation ranged from 16 – 27 (%) over three different concentrations. The limit of quantification (LOQ) was determined by two different methods and calculated to be in the range of 0.01–0.04 μg/l and 0.3–2.5 μg/kg for TCs, SAs, and MLs in water and sediment, respectively. For IPs, the LOQ was 0.001–0.003 μg/l in river water and 0.4–3.6 μg/kg for sediment. The sediment concentration measured in an agriculture-influenced river was much higher than in the overlying water matrix, indicating a high degree of sediment partitioning for these compounds.  相似文献   

18.
BDE-209 is the predominant constituent of the commercial mixture decabromodiphenyl ether which is used as brominated flame retardant (BFR). Owing to difficulties associated with the high mass (thermal instability and low vapour pressure), short GC columns (≤15?m) have been suggested for its analysis while longer columns (30–50?m) are suggested for other polybrominated diphenyl ether (PBDE) congeners. To overcome this considerable expenditure in the analysis of PBDEs, we aimed at increasing the sensitivity of BDE-209 analysis by gas chromatography coupled with electron-capture negative ion mass spectrometry (GC/ECNI-MS) on a 30?m column. The chromatographic performance of BDE-209 on the 30?m GC column was improved by increasing the carrier gas flow from initially 1.2?mL?min?1 to 5 or 10?mL?min?1 after the last octabromo diphenyl ether (Br8DE) congener was eluted. With this high carrier gas flow, the column residence time of BDE-209 was shortened by ~25%, the peak height was increased and, consequently, the limit of detection by GC/ECNI-MS in selected ion monitoring (SIM) mode was improved. When this high-flow GC/ECNI-MS-SIM method was applied to a sediment sample, we realized that gel permeation chromatography (GPC) – used for the removal of lipids and/or sulphur – provided low recovery rates for BDE-209. The large molecule BDE-209 eluted late and only 50% was recovered by our previous standard protocol for polyhalogenated compounds. Application of a modified GPC procedure with a longer collection time increased the recovery of BDE-209 in the GPC step to ~90%.  相似文献   

19.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
The present investigation describes the development and validation of a sensitive liquid chromatography–mass spectrometry/mass spectrometry (LC‐MS/MS) method for the estimation of dorsomorphin in rat plasma. A sensitive LC‐MS/MS method was developed using multiple reaction monitoring mode, with the transition of m/z (Q1/Q3) 400.2/289.3 for dorsomorphin and m/z (Q1/Q3) 306.2/236.3 for zaleplon. Chromatographic separation was achieved on a reverse phase Agilent XDB C18 column (100 × 4.6 mm, 5 µm). The mobile phase consisted of acetonitrile and 5 mm ammonium acetate buffer (pH 6.0) 90:10 v/v, at a flow rate of 0.8 mL/min. The effluence was ionized in positive ion mode by electrospray ionization (ESI) and quantitated by mass spectrometry. The retention times of dorsomorphin and internal standard were found to be 2.13 and 1.13 min, respectively. Mean extraction recovery of dorsomorphin and internal standard in rat plasma was above 80%. Dorsomorphin calibration curve in rat plasma was linear (r2 ≥ 0.99) ranging from 0.005 to 10 µg/mL. Inter‐day and intra‐day precision and accuracy were found to be within 85–115% (coefficient of variation). This method was successfully applied for evaluation of the oral pharmacokinetic profile of dorsomorphin in male Wistar rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号