首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 922 毫秒
1.
A fast and highly sensitive electrospray ionization tandem mass spectrometry (ESI-MS/MS) method has been developed for the simultaneous determination of morphine, 6-methylacetylmorphine (6-MAM), codeine, cocaine and benzoylecgonine (BZE) in hair from drug abusers. Pulverized hair samples were subjected to an optimized matrix solid phase dispersion (MSPD) procedure with alumina, followed by diluted hydrochloric acid elution on column solid-phase extraction (SPE) clean-up/pre-concentration. Alternatively, samples were also subjected to an optimized ultrasound assisted enzymatic hydrolysis (USEH) with Pronase E, followed by an off-line SPE clean up/pre-concentration procedure. Positive electrospray ionization and multiple reaction monitoring (MRM) with one precursor ion/product ion transition were used for the identification and quantification (deuterated analogues of each target as internal standards) of each analyte. The chromatographic pump and the autosampler were used for injecting the standards and the hair extracts (20 μL) as a flow injection analysis mode. The highest sensitivity was achieved when delivering the targets with an acetonitrile/water/formic acid (80/19.875/0.125) mixture. The limits of detection of the method were 39.2, 4.4, 6.8, 7.0 and 7.4 ng g(-1) for morphine, 6-MAM, codeine, cocaine and BZE, respectively. Relative standard deviations of intra- and inter-day precision were lower than 9 and 12%, respectively; whereas, analytical recoveries ranged from 96±5 to 106±4%. The developed method (MSPD-ESI-MS/MS) was applied to different hair samples from polydrug abusers, and results were statistically compared to those obtained after a conventional gas chromatography-mass spectrometry (GC-MS) analysis and also after USEH and ESI-MS/MS or GC-MS determinations.  相似文献   

2.
Surface-activated chemical ionization (SACI) was employed for the analysis of cocaine and its metabolite, benzoylecgonine, extracted from hair. Following decontamination and acid hydrolysis procedures on the hair sample, the sample solution was diluted (1:10) and directly analyzed by liquid chromatography/surface-activated chemical ionization multiple collisional stage single reaction monitoring mass spectrometry (LC/SACI-MS(3)-SRM) without solid-phase extraction (SPE) pre-purification and concentration procedures. To increase the selectivity of the method, MS(3) was chosen instead of the less selective MS/MS. This data was compared with that achieved using gas chromatography/mass spectrometry (GC/MS), the reference method used by the Italian Government Institute of Health protocol. The limits of detection (LODs) were 0.003 ng/(mg hair) for cocaine and 0.02 ng/(mg hair) for benzoylecgonine and the limits of quantitation (LOQs) were 0.01 ng/(mg hair) for cocaine and 0.04 ng/(mg hair) for benzoylecgonine. The squared correlation coefficient (R(2)) of the calibration curve was 0.9887-0.9980 for cocaine and 0.9987-0.9997 for benzoylecgonine. The percent accuracy error was 2-5% for both cocaine and benzoylecgonine using the LC/SACI-MS(3)-SRM approach, whereas it was higher for benzoylecgonine (20-25%) using the LC/SACI-MS/MS-SRM approach compared with the GC/MS data due to hair matrix contamination. In both cases, high precision was achieved (1-3% precision error), which confirmed the stability of the developed methods.  相似文献   

3.
The use of capillary column gas chromatography and gas chromatography/mass spectrometry for the analysis of a series of standard solutions (0.1 to 10 μg/ml) of 2,4,6-trinitrotoluene (TNT) and eight other nitroaromatic components was evaluated. The techniques included gas chromatography with electron capture detection (GC/ECD), full scan and selected ion monitoring gas chromatography/mass spectrometry with electron impact ionization (EI/FS and EI/SIM), full scan and selected ion monitoring gas chromatography/mass spectrometry with positive ion chemical ionization using methane reagent gas (PICI/FS and PICI/SIM), and full scan and selected ion monitoring gas chromatography/mass spectrometry with negative ion chemical ionization using methane reagent gas (NICI/FS and NICI/SIM). The performance of the techniques was comapared by determining the linear response range, precision, and detection limits of the analyses.  相似文献   

4.
A new analytical approach, based on derivatization with 2,2,2-trichloroethyl chloroformate and gas chromatography/mass spectrometry (GC/MS), was investigated for qualitative and quantitative analyses of a large range of amphetamine-related drugs and ephedrines in plasma, urine and hair samples. Sample preparation involved alkaline extraction of analytes from biological samples using Extrelut columns, after addition of the internal standard 3,4-methylenedioxypropylamphetamine (MDPA), and subsequent derivatization to produce 2,2,2-trichloroethylcarbamates. GC/MS analyses, in splitless mode using a slightly polar 30-m capillary column, were performed with quadrupole or ion trap instruments. MS acquisition modes were electron ionization (EI) in full-scan or selected ion monitoring (SIM) modes (quadrupole), and full-scan MS or MS/MS modes with chemical ionization (CI) conditions (ion trap). EI spectra of 2,2,2-trichloroethylcarbamates showed variably abundant molecular ions as well as abundant diagnostic fragment ions, both characterized by ion clusters reflecting the isotope distribution of three chlorine atoms in the derivatized molecules. CI spectra showed abundant protonated molecules. Quantitative studies using EI SIM conditions gave recoveries in the range 74-89%, linear response over ranges of 10-2000 ng/mL (plasma and urine) and 0.20-20 ng/mg (hair), with corresponding limits of detection in the ranges 2-5 ng/mL and 0.1-0.2 ng/mg. Potential applications (following full method validation) include clinical and forensic toxicology, as well as doping control.  相似文献   

5.
A simple and sensitive gas chromatography/tandem mass spectrometry (GC/MS/MS) method is described for the detection of anabolic steroids, usually found in keratin matrix at very low concentrations. Hair samples from seven athletes who spontaneously reported their abuse of anabolic steroids, and in a single case cocaine, were analyzed for methyltestosterone, nandrolone, boldenone, fluoxymesterolone, cocaine and its metabolite benzoylecgonine. Anabolic steroids were determinate by digestion of hair samples in 1 m NaOH for 15 min at 95 degrees C. After cooling, samples were purificated by solid-phase and liquid-liquid extraction, then anabolic steroids were converted to their trimethylsilyl derivative and finally analyzed by GC/MS/MS. For detection of cocaine and benzoylecgonine, hair samples were extracted with methanol in an ultrasonic bath for 2 h at 56 degrees C then overnight in a thermostatic bath at the same temperature. After the incubation, methanol was evaporated to dryness, and benzoylecgonine was converted to its trimethylsilyl derivative prior of GC/MS/MS analysis. Results obtained are in agreement with the athletes' reports, confirming that hair is a valid biological matrix to establish long-term intake of drugs.  相似文献   

6.
Two new standard reference materials (SRM) for drugs of abuse in human hair have been developed. SRM 2379 consists of hair spiked with cocaine, benzoylecgonine, cocaethylene, phencyclidine, amphetamine, and methamphetamine. SRM 2380 consists of hair spiked with codeine, morphine, monoacetylmorphine, and tetrahydrocannabinol (THC). The SRMs were prepared by soaking the hair in a solution of the target analytes in water-dimethylsulfoxide. The concentration of each analyte was determined using two methods, one based upon gas chromatography/mass spectrometry (GC/MS) and one based upon liquid chromatography/mass spectrometry (LC/MS). Both methods used 0.1 M HCl for extraction of all the analytes from the hair, except for THC, which was extracted with 1 M NaOH. For isolation of the analytes from the extracts, the GC/MS-based methods used different clean-up procedures from those used for the LC/MS-based methods. The results from the two methods were in good agreement with mean differences for the analytes ranging from 4% to 16%. These materials will enable laboratories performing analyses of hair for drugs of abuse to test the accuracy of their methods.  相似文献   

7.
A technique using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOFMS) is applied to a qualitative analysis of three sample extracts from hair suspected of containing various drug compounds. The samples were also subjected to a quantitative target analysis for codeine, morphine, 6-monoacetylmorphine (6-MAM), amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethylamphetamine (MDMA), methadone, and benzylpiperazine (BZP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). GC × GC/TOFMS provided a non-specific procedure that identified various drugs, metabolites, and impurities not included in the target analysis. They included cocaine, diazepam, and methaqualone (quaalude). Comprehensive GC × GC separation was achieved using twin-stage cryo-modulation to focus eluant from a DB-5ms (5% phenyl) to a BPX50 (50% phenyl) GC column. The TOF mass spectrometer provided unit mass resolution in the mass range m/z 5–1000 and rapid spectral acquisition (≤500 spectra/s). Clean mass spectra of the individual components were obtained using mass spectral deconvolution software. The ‘unknown’ components were identified by comparison with mass spectra stored in a library database.  相似文献   

8.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

9.
A sensitive negative chemical ionization (NCI) gas-chromatography/mass spectrometry (GC/MS) method for the detection of estrogens is described. After hydrosis and clean-up by C18 ODS solid phase extraction (SPE) cartridge, the extracts obtained were derivatized with heptafluorobutyric anhydride and analyzed in the negative ion mode by GC/MS. Stability of derivatives was good. Selected ion monitoring (SIM) mode was applied to increase the sensitivity and, when possible, the higher m/z ions were selected to improve identification. The detection limit of the HFB esters in NCI using SIM was below 10 femtograms.  相似文献   

10.
Analysis of sub-ppb levels of polynuclear aromatic hydrocarbons (PAHs) in drinking water by high performance liquid chromatography (HPLC) fluorescence detection typically requires large water samples and lengthy extraction procedures. The detection itself, although selective, does not give compound identity confirmation. Benchtop gas chromatography/mass spectrometry (GC/MS) systems operating in the more sensitive selected ion monitoring (SIM) acquisition mode discard spectral information and, when operating in scanning mode, are less sensitive and scan too slowly. The selectivity of hyperthermal surface ionisation (HSI), the high column flow rate capacity of the supersonic molecular beam (SMB) GC/MS interface, and the high acquisition rate of time-of-flight (TOF) mass analysis, are combined here to facilitate a rapid, specific and sensitive technique for the analysis of trace levels of PAHs in water. This work reports the advantages gained by using the GC/HSI-TOF system over the HPLC fluorescence method, and discusses in some detail the nature of the instrumentation used.  相似文献   

11.
The application of single-drop microextraction (SDME) followed by gas chromatography/chemical ionization mass spectrometry (GC/CI-MS) was investigated for the determination of anisaldehyde isomers in human urine and blood serum. The effects of extraction solvent, sample agitation rate, salt addition, sampling time and temperature on the extraction efficiency were examined and optimized. Analytical parameters such as linearity, reproducibility, detection limit and relative recovery were evaluated under the optimized experimental conditions. Good reproducibilities of replicate extractions (n = 5) were obtained, with relative standard deviation (RSD) values below 6%. The limits of detection (LOD) using an extraction time of 5 min were found to be in the range 2-5 ng/mL under the selected ion monitoring (SIM) mode of GC/MS. Recoveries of 82-98% were achieved after 5 min extraction.  相似文献   

12.
A fast, simple and inexpensive sample preparation method based on the matrix solid-phase extraction (SPE) technique is proposed for the isolation of cypermethrin and its metabolite residues from soils. Both the extraction and clean-up procedures were carried out in two steps and target compounds were determined by gas chromatography coupled with electron-impact mass spectrometry (GC-EI/MS). The characteristic ions and fragmentation mechanism of cypermethrin were evaluated by electron impact ionization mass spectrometry (EI/MS). After the optimization of different parameters, such as the extraction solvent, the pesticide was extracted from the matrix with methanol/acetone in a Soxhlet extractor, cleaned up on a Florisil column by elution with a mixture of 30% ethyl acetate in n-hexane and analyzed by gas chromatography-electron impact ionization mass spectrometry (GC-EI/MS) in the selected ion-monitoring mode (SIM) with permethrin as internal standard. Recovery was in the range 77–118% with relative standard deviations (RSD) between 2.5% and 10.2%. The limit of detection (LOD) was 6.5?µg/kg for cypermethrin. The developed method was linear in the injection range 6–30?ng, with correlation coefficients greater than 0.9957.  相似文献   

13.
In forensic toxicology, hair analysis has become a well established analytical strategy to investigate retrospectively drug abuse histories. In this field, gas chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry are currently used, often after preliminary screening with immunoassays. However, on the basis of previous applications to pharmaceutical analysis, capillary zone electrophoresis coupled to ion trap mass spectrometry looks also highly promising. The purpose of the present work was the development of a simple and rapid CZE-MS method for sensitive and quantitative determination of the main drugs of abuse and their metabolites (namely, 6-monoacetylmorphine, morphine, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethampthetamine (MDMA), benzoylecgonine, ephedrine and cocaine) in human hair. Hair samples (100 mg) were washed, cut and incubated overnight in 0.1 M HCl at 45 degrees C, then neutralized with NaOH and extracted by a liquid-liquid extraction method. CZE separations were carried out in a 100 cm x 75 microm (I.D.) uncoated fused silica capillary. The separation buffer was composed of 25 mM ammonium formate, pH 9.5; the separation voltage was 15 kV. Electrokinetic injections were performed at 7 kV for 30 s under field amplified sample stacking conditions. ESI-ion trap MS detection was performed in the ESI positive ionization mode using the following conditions: capillary voltage 4 kV, nebulizer gas (nitrogen) pressure 3psi, source temperature 150 degrees C and drying gas (nitrogen) flow rate 8l/min. A sheath liquid, composed of isopropanol-water (50:50, v/v) with 0.5% formic acid, was delivered at a flow rate of 4 microl/min. The ion trap MS operated in a selected ion monitoring mode (SIM) of positive molecular ions for each drug/metabolite. Collision induced fragmentation was also possible. Nalorphine was used as internal standard. Under the described conditions, the separation of all compounds, except amphetamine/methamphetamine, MDA/MDMA and morphine/6-MAM was achieved in 20 min, with limits of detection lower than the most severe cut-offs adopted in hair analysis (i.e. 0.1 ng/mg). Linearity was assessed within drug concentration ranges from 0.025 to 5 ng of each analyte/mg of hair. Analytical precision was fairly acceptable with RSD's < or = 3.06% for migration times and < or = 22.47% for areas in real samples, in both intra-day and day-to-day experiments. On these grounds, the described method can be proposed for rapid, selective and accurate toxicological hair analysis for both clinical and forensic purposes.  相似文献   

14.
The electrospray ionization (ESI) ion trap and quadrupole time-of-flight (QqToF) mass spectra of heroin and seven related alkaloids, i.e., morphine, codeine, O-6-monoacetylmorphine (6-MAM), thebaine, acetylcodeine, papaverine and narcotine, have been extensively investigated in this work. The ESI mass spectrometric fragmentation pathways of protonated 6-MAM, heroin, acetylcodeine, and thebaine were comprehensively elucidated for the first time with the aid of high-resolution mass spectrometry. It was found that cleavage of the piperidine ring was the featured fragmentation route of six of the compounds, although not of papaverine and narcotine. In addition, a simple high-performance liquid chromatography (HPLC)-based separation method gave baseline resolution of all eight components. This study could play an important role in the screening for these alkaloids in different matrices by HPLC coupled to tandem mass spectrometry (MS/MS).  相似文献   

15.
It is of importance to differentiate heroin intake from the absorption of opiate-containing pharmaceuticals or opiates from other sources. A method for the routine determination of O6-monoacetylmorphine (6-MAM), the specific metabolite of heroin in human urine, by gas chromatography and classical detectors without having recourse to gas chromatography/mass spectrometry-selected ion mode (GC/MS-SIM) is described. With dual detection by nitrogen selective and flame ionization detectors, the limits of detection for 6-MAM were determined to be 2 ng/mL and 4 ng/mL urine for a 10 mL sample. When applied to urines preliminarily screened for opiates, the results appeared consistent in comparison with those obtained by GC/MS-SIM. The method was also developed for the simultaneous quantitative analysis of morphine and codeine. The linearity was tested up to 600 ng/mL for the three compounds of interest 6-MAM, morphine and codeine and their absolute recoveries were 76%, 78%, 75% respectively.  相似文献   

16.
Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionization (DESI) mass spectrometry (MS). In this work the feasibility of DESI application for the rapid screening of intact esters of anabolic steroids in bovine hair has been studied. Using a linear ion trap both full scan and data-dependent collision induced dissociation MS(n) spectra were acquired in minutes for testosterone cypionate, testosterone decanoate and estradiol benzoate standard solutions deposited on a glass or PTFE surface. However direct analysis of incurred hair failed due to inefficient desorption ionization and the minute quantities of steroid esters present. Therefore a simplified ultrasonic liquid extraction procedure was developed, allowing rapid DESI analysis of a few microliters of the concentrate and a total analysis time of 2-4h per batch instead of 3 days. The potential of this DESI approach is clearly demonstrated by MS(3) data from hair samples incurred with high levels (300-800 μg kg(-1)) of steroid esters, levels which do occur in samples from controlled- and illegally treated animals. For much lower levels state-of-the-art ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) screening methods remain the method of choice and might benefit from the proposed simplified extraction as well.  相似文献   

17.
A fast and sensitive liquid chromatography/triple quadrupole tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous determination of morphine, codeine, 6‐acetylmorphine (6‐AM), cocaine and benzoylecgonine (BE) in hair. Pulverized hair samples were extracted with methanol, and a 50 µL supernatant aliquot was injected into the LC/MS/MS system. Chromatography was performed with an XBridge? phenyl column (3.5 µm particle size, 4.6 × 150 mm), and the mobile phase was composed of methanol and 10 mM ammonium acetate adjusted to pH 4.00 with 99% formic acid (95:5, v/v). A separation run with isocratic elution was completed in 10 min at a flow rate of 500 µL/min. Positive electrospray ionization and multiple reaction monitoring (MRM) with one precursor ion/product ion transition were used for the identification of each analyte. Deuterated analogues as internal standards were used for quantification and qualification. Linearity was established in the concentration range of 100–3000 pg/mg. The limits of detection were 10 pg/mg for morphine, codeine and 6‐AM; and 1 pg/mg for cocaine and BE. The precision and accuracy were determined by spiking hair samples at six concentration levels. For all analytes, the relative standard deviations of intra‐ and inter‐day precision were 0.1–6.3% and 1.5–10.6%, respectively. The accuracy ranged from 92.7 to 109.7%. The validated LC/MS/MS method was successfully applied to the analysis of 79 authentic hair samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
A sample preparation method based on single solvent phase extraction and solid-phase extraction (SPE-NH2) clean-up is studied in combination with fast capillary gas chromatography (GC) to determine 18 selected pesticides belonging to various chemical classes in apples, the common raw material for baby food production and baby food, at the concentration level < or = 10 microg/kg maximum residual limit (MRL). Possibilities of mass spectrometry (MS) detector and electron capture detector (ECD) in fast gas chromatography (GC) of samples with complex matrice at ultra trace levels of pesticide residues were studied and compared. MS detection in single ion monitoring (SIM) mode provided higher selectivity compared to ECD. Optimisation of extraction as well as the simplifying of the whole process of sample preparation was carried out. Recoveries obtained at concentration level of 5 microg/kg (the required value for limit of quantification (LOQ) in baby food) were >90%, except of dimethoate (77.7%) and captan (46.4%) with MS detection. The obtained LOQs were at least 1 order lower than 5 microg/kg for the majority of compounds. The repeatability of gas chromatography-mass spectrometry (GC-MS) measurements of the matrix matched standards expressed as relative standard deviation was <11% except of captan and cypermethrin.  相似文献   

19.
《Analytical letters》2012,45(2):231-258
Abstract

Interest in hair analysis as an alternativ or complementary approach to urinalysis for drug abuse detection has grown in recent years. Hair analysis can be particularly advantageous for drugs and their enantiomers.

More than hundred pharmaceuticals, drugs of abuse agents are reported to be detectable in human and animal hair. This article reviews the aalysis of drugs and drug metabolites by chromatographic procedures, incuding the pretreatment steps, and the xtraction methods. Tihe eneral tendency in the last years, to highly sophisticated techiques gas chromatography–mass spectrometry (GC–MS–NCI), high pressure liquid chromatography–mass spectrometry (HPLC–MS), gas chromatography–mass spectrometry–mass spectrometry (GC–MS–MS) well illustrates this constant fight for sensitivity.  相似文献   

20.
The new ionization method, called surface-activated chemical ionization (SACI), was employed for the analysis of fives drugs (morphine, codeine, 6-monoacetylmorphine (6-MAM), benzoylecgonine and cocaine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI), no-discharge-APCI and electrospray ionization (ESI) clearly showing that SACI is the most sensible one mainly due to the high ionization efficiency and the lower chemical noise. The performance of SACI in terms of sensitivity and linearity was compared with the sensitivity and linearity obtained using APCI, no-discharge-APCI and ESI, showing that the new SACI approach gives rise to the best results. Then, SACI was used to analyze morphine, codeine, 6-MAM, benzoylecgonine and cocaine in urine samples. After the optimization of the instrumental parameters for a mixture of the standard compounds, eight urine samples were analyzed. They were strongly diluted (1 : 20 and 1 : 100) in order to prevent the chromatographic column damage due to the matrix composition. Furthermore, the diluted urine samples were directly analyzed, without pretreatment, through LC-MS and LC-MS/MS, and the obtained results are reported.  相似文献   