首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The atmospheric-pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI-QIT) analysis of tryptic peptides is reported following capillary liquid chromatographic (LC) separation and direct analysis of a protein digest. Peptide fragments were identified by peptide mass fingerprinting from mass spectrometric data and sequence analysis obtained by tandem mass spectrometry of the principal mass spectral peaks using a data-dependent scanning protocol. These data were compared with those from mass spectrometric analysis using capillary LC/MALDI-time-of-flight (TOF) and capillary LC/electrospray ionisation (ESI)-quadrupole TOF. For all three configurations the resulting data were searched against the MSDB database, using MASCOT and the sequence coverage compared for each technique. Complementary data were obtained using the three techniques.  相似文献   

2.
Strains of certain plant pathogenic bacteria, in particular several pathovars of Pseudomonas syringae, are known to produce cyclic lipodepsipeptides (LDPs) endowed with peculiar structural features and noticeable biological activities. In this study, a mass spectrometry procedure is proposed for screening LDP-producing bacterial strains and for identifying and assessing individual LDPs. After matrix-assisted laser desorption/ionisation time-of-flight (MALDI-TOF) screening of thirteen P. syringae strains for LDP production, the extracts from culture filtrates of eight positive strains were subjected to electrospray mass spectrometry for the identification of LDPs. Five strains were found to produce two forms of syringomycins (SR-E and SR-G) and two forms of syringopeptin 25 (SP25A and SP25B); two strains produced SR-E, SR-G and a new form of SP22; one strain produced syringotoxin (ST) and syringostatin A (SS-A) in addition to SP25A and SP25B. The yield in culture of two major LPDs: SR-G (3.2-13.8 mg x L(-1)) and SP25A (41.6-231.5 mg x L(-1)) was assessed by and high-performance liquid chromatography with electrospray mass spectrometry (HPLC/ESI-MS) in both scan and single ion monitoring (SIM) modes. Results of this investigation showed that the mass spectrometry protocol developed here is a precise and reliable method for screening bacterial strains for LDP production and for assessing the amount of each metabolite under various culture conditions. This could be of practical value in view of potential applications, e.g. biocontrol of post-harvest fungal diseases.  相似文献   

3.
Structural studies of the high molecular weight (HMW) glutenin subunits 1Dy10 and 1Dy12 of bread wheat were conducted using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) and reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (RP-HPLC/ESI-MS). For both proteins, MALDI-TOFMS analysis showed that the isolated fractions contained a second component with a mass about 500-540 Da lower than the major component. The testing and correction of the gene-derived amino acid sequences of both proteins were performed by direct MALDI-TOFMS analysis of their tryptic peptide mixture and analysis of the digests was performed by recording several MALDI mass spectra of the mixture at low, medium and high mass ranges, optimising the matrix and the acquisition parameters for each mass range. Complementary data were obtained by RP-HPLC/ESI-MS analysis of the tryptic digest. This resulted in the coverage of the whole protein sequences except for two short fragments (T1 and T8), which are identical in the two homologous subunits, and for an additional dipeptide (T14) in subunit 1Dy12, which were not detected. It also demonstrated that, in contrast to the gene-derived data, the sequence of subunit 1Dy12 does not include the dipeptide Gly-Gln between residues Gln(454) and Pro(455), and that the lower mass components present in both fractions correspond to the same sequences lacking short peptides that are probably lost from the protein N- or C-termini. Finally, the results obtained provide evidence for the lack of a substantial level of glycosylation or other post-translational modifications of the two subunits, and demonstrate that mass spectrometric mapping is the most useful method presently available for the direct verification of the gene-derived sequences of HMW glutenin subunits and similar proteins.  相似文献   

4.
Purified olive pulp glucuronoxylans, with a Xyl/GlcA ratio of 7:1, were subjected to mild acid hydrolysis and the mixture of oligosaccharides obtained was fractionated by size exclusion chromatography. One elution fraction representative of low molecular weight oligosaccharides was analysed by mass spectrometry using matrix-assisted laser desorption/ionisation (MALDI) and electrospray ionisation (ESI) as ionisation methods, in the positive mode. Both types of spectra showed cationised molecules [M + Na](+) of xylo-oligosaccharides in a range below m/z 1,000. The xylo-oligosaccharide structures identified were series of neutral oligosaccharides of xylose (Xyl(n), n = 3-7), of acidic oligosaccharides substituted by one glucuronic acid (Xyl(n)GlcA, n = 3-5) and by two glucuronic acid residues (Xyl(n)GlcA(2), n = 2 and 3), and also of acidic oligosaccharides substituted with one 4-O-methylglucuronic acid residue (Xyl(n)meGlcA, n = 2-4). The proposed structures were confirmed by tandem mass (MS/MS) spectra obtained using collision induced dissociation of the molecular ions. Fragmentation of cationised adducts of neutral Xyl(n) yielded C- and A-type fragments, while ammonium adducts mainly yielded B-type fragments. The fragmentation of the sodium adducts of acidic oligosaccharides (Xyl(n)meGlcA, Xyl(n)GlcA) resulted in the loss of the substituting residue (GlcA or meGlcA) as the predominant fragment, while the corresponding ammonium adducts yielded B-type fragments.  相似文献   

5.
An increase in the use of condoms by sexual offenders has been observed. This is likely to be due both to the risk of sexually transmitted diseases and to prevent the transfer of DNA evidence. In this scenario the detection of condom lubricants at a crime scene could aid in proving corpus delicti. Here we show a novel application of Matrix-Assisted Laser Desorption/Ionisation Mass Spectrometry Imaging (MALDI MSI) for mapping the fingermark ridge pattern simultaneously to the detection of the condom lubricant within the fingermark itself. Two condom brands have been investigated to prove the concept. Condoms were handled producing lubricant-contaminated fingermarks. Images of the ridge pattern were obtained simultaneously to the detection of two lubricants, even several weeks after the fingermark deposition. The results therefore show the potential of MALDI MSI to link the suspect (identification through fingermark ridge pattern) to the crime (detection of condom lubricant) in one analysis. This would enable forensic scientists to provide evidence with stronger support in alleged cases of sexual assault.  相似文献   

6.
The identification, quantification and localisation of steroids in biological fluids and tissues are subjects of considerable importance. Not only do steroids have classical hormonal properties via binding to nuclear receptors, they can also elicit cellular responses via interactions with other proteins. For mass spectrometric analysis, neutral steroids are not readily ionised by either electrospray (ES) or matrix-assisted laser desorption/ionisation (MALDI). In this communication a derivatisation protocol is presented which allows for the rapid analysis of neutral oxosteroids by both ES and MALDI mass spectrometry. Neutral oxosteroids are derivatised to Girard P hydrazones. When analysed by tandem mass spectrometry the derivatised steroids fragment to give structurally informative spectra allowing subsequent steroid identification. The derivatisation method is simple, the reagents are commercially available, and reaction products are easily isolated from the reaction mixture. Analyte identification can be performed at the sub-pg level.  相似文献   

7.
Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) has been investigated as a tool for accurate determination of the molecular mass of synthetic analogues of prazosine, a molecule used for the treatment of hypertension. Samples were dissolved in methanol, mixed with mass calibration standards, and crystallised on the target with alpha-cyano-4-hydroxycinnamic acid as matrix. Acquisition of spectra was rapidly completed in reflectron mode, allowing high resolution (6000-10000) and sensitive (about 1-10 pmol of sample on target) determination of the synthetic products. The results show the effectiveness of MALDI-TOFMS for accurate mass determination of these fairly large molecules, which are otherwise difficult to analyse by other high-resolution mass spectrometric techniques.  相似文献   

8.
Atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI/QIT) mass spectrometry has been investigated for the analysis of polyethylene glycol (PEG 1500) and a hyperbranched polymer (polyglycidol) in the presence of alkali-metal salts. Mass spectra of PEG 1500 obtained at atmospheric pressure showed dimetallated matrix/analyte adducts, in addition to the expected alkali-metal/PEG ions, for all matrix/alkali-metal salt combinations. The relative intensities of the desorbed ions were dependent on the matrix, the alkali-metal salt added to aid cationisation and the ion trap interface conditions [capillary temperature, in-source collisionally-induced dissociation (CID)]. These data indicate that the adducts are rapidly stabilised by collisional cooling enabling them to be transferred into the ion trap. Experiments using identical sample preparation conditions were carried out on a vacuum MALDI time-of-flight (ToF) mass spectrometer. In all cases, vacuum MALDI-ToF spectra showed only alkali-metal/PEG ions and no matrix/analyte adducts. The tandem mass spectrometry (MS/MS) capability of the ion trap has been demonstrated for a lithiated polyglycol yielding a rich fragment-ion spectrum. Analysis of the hyperbranched polymer polyglycidol by AP-MALDI/QIT reveals the characteristic ion series for these polymers as also observed under vacuum MALDI-ToF conditions.  相似文献   

9.
A method earlier developed for the mass spectrometric (MS) identification of tetanus toxin (TTx) was applied to botulinum toxins type A and B (BTxA and BTxB). Botulinum toxins are extremely neurotoxic bacterial toxins, likely to be used as biological warfare agent. Biologically active BTxA and BTxB are comprised of a protein complex of the respective neurotoxins with specific haemagglutinins (HAs) and non-toxic non-haemagglutinins (NTNHs). These protein complexes are also observed in mass spectrometric identification. The particular BTxA complex, from Clostridium botulinum strain 62A, almost completely matched database data derived from genetic sequences known for this strain. Although no such database information was available for BTxB, from C. botulinum strain okra, all protein sequences from the complex except that of HA-70 were found to match proteins known from other type B strains. It was found that matrix-assisted laser desorption ionisation MS provides provisional identification from trypsin digest peptide maps and that liquid chromatography electrospray (tandem) mass spectrometry affords unequivocal identification from amino acid sequence information of digest peptides obtained in trypsin or pepsin digestion.  相似文献   

10.
A two-dimensional capillary array liquid chromatography system coupled with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) was developed for high-throughput comprehensive proteomic analysis, in which one strong cation-exchange (SCX) capillary chromatographic column was used as the first separation dimension and 10 parallel reversed-phase liquid chromatographic (RPLC) capillary columns were used as the second separation dimension. A novel multi-channel interface was designed and fabricated for on-line coupling of the SCX to RPLC column array system. Besides the high resolution based on the combination of SCX and RPLC separation, the developed new system provided the most rapid two-dimensional liquid chromatography (2D-LC) separation. Ten three-way micro-splitter valves used as stop-and-flow switches in transferring SCX fractions onto RPLC columns. In addition, the three-way valves also acted as mixing chambers of RPLC effluent with matrix. The system enables on-line mixing of the LC array effluents with matrix solution during the elution and directly depositing the analyte/matrix mixtures on MALDI plates from the tenplexed channels in parallel through an array of capillary tips. With the novel system, thousands of peptides were well separated and deposited on MALDI plates only in 150min for a complex proteome sample. Compared with common 2D-LC system, the parallel 2D-LC system showed about 10-times faster analytical procedure. In combination with a high throughput tandem time of flight mass spectrometry, the system was proven to be very effective for proteome analysis by analyzing a complicated sample, soluble proteins extracted from a liver cancer tissue, in which over 1202 proteins were identified.  相似文献   

11.
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.  相似文献   

12.
Three new N(1),N(5),N(14)-tris(4- hydroxycinnamoyl)spermines were identified in hydromethanolic root extracts of Microdesmis keayana J. Léonard and Microdesmis puberula Hook f. The electrospray ionisation tandem mass spectrometry (ESI-MS/MS) technique with specific nuclear magnetic resonance analysis of hydrolysed products made it possible to identify N(1),N(5),N(14)-tris(p-coumaroyl)spermine, N(1)-feruloyl,N(5),N(14)-di(p-coumaroyl)spermine and N(1),N(5),N(14)-tris(feruloyl)spermine, named keayanines B, C and D, respectively. ESI-MS/MS analysis most effectively provided structural data although high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry was also used to characterise four other compounds from Microdesmis puberula-keayanidines A, B, C and keayanine A-which had already been identified in M. keayana. This chemical data is the first to be published for M. puberula which is a commonly used plant in Central African traditional medicine.  相似文献   

13.
The results of copolymer characterization by coupling of chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques and subsequent calculation of copolymer composition using a novel software tool 'MassChrom2D' are presented. For high-resolution mass analysis copolymer samples were fractionated by means of liquid adsorption chromatography (LAC). These fractions were investigated off-line by MALDI-TOF MS. Various mono-n-butyl ethers of polyethylene oxide-polypropylene oxide copolymers (PEO-co-PPO) were investigated. As well as the copolymer composition presented in two-dimensional plots, the applied approach can give additional hints on specific structure-dependent separation conditions in chromatography.  相似文献   

14.
15.
Kidneys of clams of the genus Tridacna accumulate metabolic products from symbiotic unicellular algae that grow in the mantles of the clams. These metabolites include organoarsenic compounds that are biosynthesised by algae from arsenate in seawater. The arsenic compounds in aqueous extracts of the kidney of the giant clam T. derasa were investigated by liquid chromatography/electrospray ionisation mass spectrometry. About 50% of the water-soluble arsenic was present as dimethylarsinoylribosides and dimethylarsinate which are common algal metabolites. The major compound in the kidney (50% of water-soluble arsenic) was identified as a 5-dimethylarsinoyl-2,3,4-trihydroxycarboxylic acid, a new natural product.  相似文献   

16.
Isocyanates are an important class of compounds in occupational hygiene monitoring due mainly to their behaviour as respiratory sensitisers. Here, we demonstrate the application of matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) and MALDI tandem mass spectrometry (MS-MS) to the analysis of derivatised isocyanate monomers and prepolymers. The aim of the work has been to gauge the selectivity obtainable from the direct analysis of isocyanate mixtures without prior separation. Monomeric and prepolymeric isocyanate mixtures were analysed as their 1-(2-methoxyphenyl) piperazine derivatives and the potential of MALDI time-of-flight (ToF)-MS for an NCO monitoring program was assessed. The results obtained demonstrated the possibility of direct mixture analysis by this method. MALDI-MS-MS was used for the elucidation of fragment structures in the prepolymer samples. The developed methodology was then applied to the analysis of swabs from an occupational hygiene monitoring scheme and enabled the identification of the isocyanate species detected.  相似文献   

17.
Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.  相似文献   

18.
A refined sample preparation procedure for matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) was developed for the evaluation of the degree of substitution (DS) in partially depolymerised carboxymethyl cellulose (CMC). By adding ammonium sulphate to the sample mixture prior to the analysis, good quality mass spectra could be acquired. The usual time-consuming search for 'sweet-spots' at the crystalline rim of the MALDI target spot was also avoided. This quality improvement made it possible to investigate whether various positions on the target spot generated mass spectra in which the measured DS varied. The accuracy and reproducibility of the sample preparation procedure were tested by applying it on three commercial CMCs. The study shows that the DS values that were calculated from the spectra acquired from the centre region of the MALDI target spot were in better agreement with the DS provided by the supplier than were the values obtained from the large crystals at the target spot rim. This observation could be one reasonable explanation for the higher DS values reported in other publications. By applying our refined MALDI sample preparation procedure DS values that were in good agreement with the values provided by the manufacturer could be obtained. This indicates that MALDI-TOFMS of partially depolymerised CMCs can be used for an estimation of the DS as a complement to the more established methods, e.g. NMR, titrimetry, and chromatographic techniques.  相似文献   

19.
A method has been developed for the determination of acrylamide at the picogram per cubic metre level in particulate-phase outdoor aerosol using high-performance liquid chromatography with triple quadrupole tandem mass spectrometric detection. Acrylamide was identified by positive ion electrospray mass spectrometry using m/z 72.00/54.90 as monitoring ion transition. The limit of detection, defined as three times the standard deviation of the procedural blanks, was 0.4?pg?m?3 (173?pg absolute amount injected); the repeatability was 8% (evaluated as the relative standard deviation of five consecutive measurements on cleaned quartz fibre filters of acrylamide standard spikes) and the recovery was 52?±?4%. The accuracy of the method (evaluated as relative error) has been estimated to be ?2%. This methodology was used to determine acrylamide concentrations in particulate-phase outdoor aerosol in the Venice Lagoon with concentrations ranging between 0.4 and 12.9?pg?m?3 with an average value of 3.1?pg?m?3.  相似文献   

20.
Here we report the first application of a matrix-assisted laser desorption/ionization (MALDI) triple-quadrupole mass spectrometer for targeted proteomics. Employing an amine-specific isotopic labelling approach, the technique was validated using five randomly selected bovine serum albumin peptides differentially labelled at known ratios. An indirect benefit of the isotopic labelling technique is a significant enhancement of the a1 ion in tandem mass (MS/MS) spectra of all peptides studied. Therefore, the a1 ion was selected as the fragment ion for multiple reaction monitoring (MRM) in all cases, eliminating tedious method development and optimization. Accurate quantification was achieved with an average relative standard deviation (RSD) of 5% (n = 5) and a detection limit of 14 amol. The technique was then applied to validate an important virulence biomarker of the fungal pathogen Candida albicans, which was not accurately quantified using global proteomics experiment employing two-dimensional liquid chromatography/electrospray ionization tandem mass spectrometry (2D-LC/ESI)-MS/MS. Using LC/MALDI-MRM analysis of five tryptic peptides, the protein PHR1 was found to be upregulated in the hyphal (pathogenic) form of C. albicans by a factor of 7.7 +/- 0.8.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号