首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A rapid, sensitive and reliable high performance liquid chromatographic method coupled with tandem mass spectrometry via electrospray ionization (ESI) source (HPLC-MS/MS) has been developed and validated for the determination of anethole trithione (ATT) in human plasma. Diazepam was employed as the internal standard (IS). Sample extracts following liquid-liquid extraction were injected into the HPLC-MS/MS system. The analyte and IS were eluted isocratically on a C18 column, with a mobile phase consisting of methanol and aqueous ammonium acetate solution (5 mM) (80:20, v/v) .The ions were detected by a triple quadrupole mass spectrometric detector in the positive mode. Quantification was performed using selected reaction monitoring (SRM) of the transitions m/z 240.88 → 197.91 and m/z 285.01 → 193.02 for ATT and for the IS, respectively. The analysis time for each run was 5.0 min. The calibration curve fitted well over the concentration range of 0.02-5 ng mL−1, with the regression equation y = 1.1014x + 0.0003631, r = 0.9992. The intra-batch and inter-batch R.S.D.% were less than 15% at all concentration levels within the calibration range. The recoveries were more than 80%. The present method provides a modern, rapid and robust procedure for the pharmacokinetic study of ATT. Some important pharmacokinetic parameters of ATT in healthy Chinese volunteers are also given for the first time.  相似文献   

2.
杨波  陈勇川  向荣凤  杨丹  夏培元  刘松青 《色谱》2008,26(3):322-326
建立了测定人血浆中艾芬地尔的液相色谱-串联质谱方法。血浆样品用乙酸乙酯液-液提取后,以甲醇-6 mmol/L乙酸铵溶液(pH 7.40)(体积比为90∶10)为流动相进行分离。在Q TRAPTM串联质谱仪上,以选择性反应离子监测(SRM)方式进行定量分析,用于监测的离子为m/z 326.1→308.2 (艾芬地尔)和m/z 531.0→82.1 (酮康唑,内标)。在6 min内完成了艾芬地尔的检测,工作曲线的线性范围为0.25~50 μg/L,日内、日间精密度分别小于2.7%和6.5%,平均回收率为101.3%~105.0%,检测限为0.08 μg/L。本方法灵敏度高,特异性好,可以用于临床试验的血浆样品的检测。  相似文献   

3.
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5 > 166.1 for itopride and m/z 342.3 > 111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2 = 0.9999) over the studied range (0.5-1000 ng mL−1) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.  相似文献   

4.
饲料样品经1%三氯乙酸-二甲基亚砜提取,Waters Oasis MCX柱净化,超高效液相色谱分离,最终采用电喷雾串联四极杆质谱进行检测。结果表明,三聚氰胺在饲料中的含量范围为10~5000 μg/kg时,线性关系良好(r>0.99)。在10~100 μg/kg 的添加水平范围内的平均回收率为83%~94%,相对标准偏差为4.2%~6.5%。该方法的检出限为10 μg/kg。  相似文献   

5.
采用超高效液相色谱-串联质谱(UPLC-MS/MS)联用技术,建立了对人尿液中12种全氟有机化合物(PFCs)的分析方法。首先在尿液样品中加入相应的同位素内标,以2%(体积分数)甲酸甲醇溶液超声萃取、离心后,将提取液用弱阴离子交换固相萃取柱净化,采用UPLC-MS/MS测定,内标法定量。12种目标化合物在0.05~50 μg/L质量浓度范围内线性良好,相关系数(r)均大于0.992,检出限在0.44~3.47 ng/L之间。在20、100、500 ng/L添加水平下,平均回收率范围为80.3%~116.2%,相对标准偏差(n=6)在5.5%~13.8%之间。该方法灵敏度高、重现性好、回收率高、操作简单,适合人尿液中PFCs的测定。  相似文献   

6.
唐圣芸  王远兴  温平威  辛贞 《色谱》2014,32(2):184-188
建立了高效液相色谱-电喷雾串联质谱(HPLC-ESI-MS/MS)测定饲料中N-氨基甲酰-L-谷氨酸(NCG)含量的方法。饲料样品经甲醇提取、混合型强阴离子交换反相固相萃取(PXA)柱净化、HPLC分离后,采用ESI-MS/MS在正离子多反应监测(MRM)模式下进行检测,以碎片离子m/z 148.0和m/z 84.0进行定性,以碎片离子m/z 130.0进行定量。NCG的检出限(S/N >3)为24 μg/kg,定量限(S/N >10)为80 μg/kg,在20~1000 μg/L的质量浓度范围内峰面积与含量的线性关系良好,相关系数为0.9999。对饲料中NCG在80、200、500 mg/kg等3个添加水平下的回收率进行了测定,分别为104.0%、103.5%、95.3%,相对标准偏差分别为7.5%、6.3%、5.8%。结果表明,该方法操作简单,净化效果好,快速,灵敏度和准确度高,符合对饲料样品中NCG检测分析的要求。  相似文献   

7.
Wang B  Xie L  Lin Y  Yan Z  Wang L 《色谱》2011,29(3):223-227
建立了高效液相色谱-电感耦合等离子体质谱(HPLC-ICP-MS)联用检测硒酸盐(SeVI)、亚硒酸盐(SeIV)、硒代蛋氨酸(SeMet)、硒代胱氨酸(SeCys2)和硒代乙硫氨酸(SeEt)的方法。采用Hamilton PRP X-100色谱柱(250 mm×4.6 mm, 5 μm),使用5 mmol/L的柠檬酸溶液(pH 4.5)作为流动相,电感耦合等离子体质谱(ICP-MS)检测,在21 min内可以完全分离5种硒形态。各形态硒的线性相关系数均大于0.9995, SeVI、SeIV、SeMet、SeCys2、SeEt的检出限分别为0.4、0.4、5.6、0.9、1.2 μg/L。探讨了不同提取方法的提取效果,鲜蘑菇和猪肉样品加标回收实验表明,对水溶性良好的无机硒和硒代蛋氨酸而言,采用柠檬酸溶液提取的效果非常好,SeIV和SeVI的回收率均在100%左右,SeMet的回收率为85.0%~95.3%;用蛋白酶水解提取,SeCys2和SeEt的回收率为79.9%~91.5%。该方法可完全满足食品中这5种硒形态的准确定量分析。  相似文献   

8.
建立了一种贝类组织中原多甲藻酸(azaspiracid, AZA)贝类毒素主要成分AZA1的高效液相色谱-串联质谱检测方法。本方法采用甲醇-水(80:20, v/v)溶液对贝类组织中AZA1进行提取,并用MAX阴离子交换固相萃取(SPE)柱富集净化,使用Atlantis dC18(150 mm×4.6 mm, 5.0 μm)色谱柱分离,以含有50 mmol/L甲酸和2 mmol/L甲酸铵的乙腈-水溶液(80:20, v/v)为流动相进行等度洗脱,质谱采用选择反应监测(SRM)模式。AZA1在5 min内获得完全分离,且在48.85~2 442 ng/L范围内线性良好,相关系数为0.998 1。该方法检出限(S/N=3)为11.00 pg/g,添加水平为36.64、73.27、146.54 pg/g时的平均回收率为75.8%~82.5%(n=6),相对标准偏差小于10%。利用该方法对采自大连、青岛、广州水产品市场上的112个贝类样品进行了分析,发现采自大连和广州的部分贝类样品中含有AZA1。结果表明,该方法具有简单、快速、灵敏度高等特点,能充分满足贝类中AZA1检测的要求。  相似文献   

9.
建立了高效液相色谱-电喷雾串联质谱(HPLC-ESI MS/MS)分析环境水样中22种抗生素类药物的方法。采用HLB固相萃取柱对环境水样中的目标化合物进行富集、净化,然后以6 mL氨水-甲醇(5:95, v/v)溶液洗脱。收集的洗脱液经氮气吹干至1 mL,然后进行HPLC-ESI MS/MS分离分析。色谱流动相A相为甲醇-乙腈(1:1, v/v), B相为0.3%(体积分数)甲酸水溶液(含0.1%(体积分数)甲酸铵,pH 2.9);色谱柱为XTerra MS C18柱。质谱检测采用正离子扫描,多反应监测模式。分别以自来水和污水作为基质,22种抗生素类药物的加标平均回收率分别为54.9%~130%和57.4%~138%,相对标准偏差(n=3)分别为2.85%~28.6%和2.02%~23.2%;方法的检出限为0.05~0.5 ng/L。将建立的方法应用于北京市高碑店湖和小清河水样的分析,结果表明在两个水样中均有部分抗生素类药物检出。  相似文献   

10.
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
Yin F  Ding Z  Cao X  Gao J  Jiang D  Kuang D  Gu Y  He G 《色谱》2011,29(6):554-557
建立了食醋中3种甜味剂的固相萃取-高效液相色谱/串联质谱分析方法。样品经酸性水稀释,弱阴离子固相萃取柱净化,Pursuit C18色谱柱分离,10 mmol/L醋酸铵(含0.1%氨水)和乙腈为流动相梯度洗脱,电喷雾负离子模式下多反应监测(MRM)模式检测。糖精钠、安赛蜜、甜蜜素的定量限分别为10、5、5 μg/kg,回收率为72.1%~96.8%,相对标准偏差小于15%。该方法准确、灵敏度高,可用于食醋中甜味剂的定性定量检验。  相似文献   

12.
A simple method using a one-step liquid-liquid extraction (LLE) followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of bromazepam in human plasma, using lorazepam as internal standard. The acquisition was performed in the multiple reaction monitoring mode, monitoring the transitions: m/z 316 > 182 for bromazepam and m/z 321 > 275 for lorazepam. The method was linear over the studied range (1-100 ng ml(-1)), with r(2) > 0.98, and the run time was 2.5 min. The intra- and inter-assay precisions were 2.7-14.6 and 4.1-17.3%, respectively and the intra- and inter-assay accuracies were 87-111 and 75.8-109.5%, respectively. The mean recovery was 73.7%, ranging from 64.5 to 79.7%. The limit of quantification was 1 ng ml(-1). At this concentration the mean intra- and inter-assay precisions were 14.6 and 7.1%, respectively, and the mean intra- and inter-assay accuracies were 102.5 and 104%, respectively. Bromazepam stability was evaluated and the results showed that the drug is stable in standard solution and in plasma samples under typical storage and processing conditions. The method was applied to a bioequivalence study in which 27 healthy adult volunteers (14 men) received single oral doses (6 mg) of reference and test bromazepam formulations, in an open, two-period, randomized, crossover protocol. The 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak plasma concentration), AUC(0-96) and AUC(0-inf) (area under the plasma concentration versus time curve from time zero to 96 h and to infinity, respectively) were within the range 80-125%, which supports the conclusion that the test formulation is bioequivalent to the reference formulation regarding the rate and extent of bromazepam absorption.  相似文献   

13.
赵珊  张晶  杨奕  邵兵 《色谱》2010,28(4):356-362
建立了以超高效液相色谱-电喷雾串联四极杆质谱(UPLC-MS/MS)检测果汁和葡萄酒中27种工业染料的方法。样品经乙腈振荡提取,在盐析作用下分层,目标化合物转移至乙腈层中。目标化合物在梯度洗脱条件下经C18柱分离后采用多反应监测(MRM)模式进行检测。其中24种工业染料使用正离子模式检测,流动相为乙腈和0.1%的甲酸水溶液;其余3种工业染料则采用负离子模式检测,流动相为乙腈和水。结果表明: 果汁中27种工业染料的定量限(LOQ)为0.1~50 μg/kg,回收率为57.0%~117.7%,相对标准偏差为2.4%~17.7%。葡萄酒中的LOQ为0.2~50 μg/kg,回收率为40.8%~109.4%,相对标准偏差为1.6%~17.9%。该方法操作简单,灵敏度高,实现了不同种类的工业染料的同时提取,适合于软饮料中非法添加工业染料的快速检测。  相似文献   

14.
液相色谱-电喷雾串联质谱法测定生姜中的215种农药残留   总被引:4,自引:1,他引:4  
曹静  庞国芳  王明林  范春林 《色谱》2010,28(6):579-589
建立了生姜中215种农药多残留测定的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)方法。样品用1%醋酸-乙腈溶液均质提取,经Sep-Pak Vac固相萃取柱净化,乙腈-甲苯(3:1, v/v)洗脱,旋转蒸发浓缩至约0.5 mL后,于室温氮气吹干,用乙腈-水(3:2, v/v)溶解,以电喷雾电离串联质谱在正离子多反应监测(MRM)模式下进行测定。在定量限水平进行添加回收率实验,方法的回收率范围为68.1%~132.6%,其中回收率在70%~120%的占94.4%,相对标准偏差(RSD)范围为0.4%~25.0%。方法的检出限(S/N=3)和定量限(S/N=10)范围分别为0.01~70.45 μg/L和0.04~234.84 μg/L。该方法操作简便,灵敏度、准确度和精密度均符合农药多残留检测技术要求,适用于生姜中215种农药多残留的快速测定。  相似文献   

15.
建立了高效液相色谱-二极管阵列检测器(HPLC-DAD)及HPLC-电喷雾串联质谱(ESI-MS/MS)测定植物源性蛋白中残留的三聚氰胺的方法。利用HPLC-DAD进行样品中三聚氰胺的初筛,利用HPLC-MS/MS进行确证。采用三氯乙酸溶液沉淀样品中的蛋白,同时提取目标分析物,质谱检测时样品再经强阳离子固相萃取柱富集净化。HPLC-DAD的检测低限为10 mg/kg,HPLC-MS/MS的检测低限为0.5 mg/kg;HPLC-DA的添加回收率为76%~88%,HPLC-MS/MS的添加回收率为72%~82%(基质匹配曲线校正),两种方法的添加回收率的相对标准偏差(RSD)为3.4%~6.4%。  相似文献   

16.
高效液相色谱-串联质谱法检测牛奶中头孢洛宁残留   总被引:3,自引:0,他引:3  
李帅鹏  郭春娜  孟蕾  黄显会 《色谱》2014,32(5):519-523
建立了牛奶中头孢洛宁残留检测的高效液相色谱-串联质谱方法。1 g牛奶经乙腈沉淀蛋白质后,上清液于37 ℃水浴下氮气吹干,用1 mL甲醇-0.1%甲酸水溶液(3:7,v/v)复溶,正己烷除脂净化后检测。流动相为乙腈和0.1%甲酸水溶液,梯度洗脱,经C18色谱柱分离,采用多反应监测正离子模式对头孢洛宁进行定性定量分析。采用基质匹配法对牛奶中头孢洛宁的含量进行标准校正,在2~200 μg/L范围内,头孢洛宁质量浓度与其对应峰面积的线性关系良好,相关系数>0.999。牛奶中加标样品的检出限(按S/N≥3计)为0.5 μg/kg,定量限(S/N≥10计)为2 μg/kg。在定量限、1/2最高残留限量、最高残留限量、2倍最高残留限量添加水平下,牛奶中头孢洛宁的平均回收率为78.5%~86.2%,日内相对标准偏差为1.5%~6.2%,日间相对标准偏差为2.9%~5.6%。该方法可用于牛奶中头孢洛宁的残留检测。  相似文献   

17.
A novel, specific and rapid ultra performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for determination of teniposide in rat plasma. A one‐step liquid–liquid extraction method was used and the separation was carried out on an Acquity UPLCTM BEH C18 column with gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.20 mL/min. A triple quadrupole tandem mass spectrometer in multiple‐reaction monitoring mode via an electrospray ionization interface was used for the detection of teniposide. The detection was complete within 3.0 min. A linear calibration curve was obtained over the concentration range 10–10,000 ng/mL for teniposide, with a lower limit of quantification of 10 ng/mL. The intra‐day precision and inter‐day precision (relative standard deviation) were less than 10.23 and 13.09%, respectively. The developed method was applied for the first time to the pharmacokinetic study of teniposide in rats following a single intravenous administration of 4.5 mg/kg teniposide. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of pramipexole in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 212/152 for pramipexole and m/z 409/228 for the IS. The method exhibited a linear dynamic range of 200-8000 pg/mL for pramipexole in human plasma. The lower limit of quantification was 200 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 3.5 min for each sample made it possible to analyze more than 200 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

19.
薄海波 《色谱》2011,29(2):180-183
建立了水果、蔬菜、豆类和粮谷中百草枯残留的高效液相色谱-串联质谱(HPLC-MS/MS)分析方法.用水提取样品中的百草枯,弱阳离子交换(WCX)固相萃取柱(SPE)净化.采用CAPCELL PAK ST色谱柱(150 mm×2.0mm).乙腈-10 mmol/L乙酸铵水溶液(用甲酸调至pH 4.0)为流动相,以电喷雾离...  相似文献   

20.
建立正相液相色谱-串联质谱(LC-MS/MS)分离普萘洛尔对映体的方法,并用于盐酸普萘洛尔片对映体含量测定.样品使用甲醇进行简单提取,采用Chiralcel OD-H手性柱,以正己烷-乙醇-氨水(70∶30∶0.4, v/v/v)为流动相,流速为0.4 mL/min.在正离子模式下,通过电喷雾离子化(ESI+),采用多...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号