首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Ocaña JA  Barragán FJ  Callejón M 《The Analyst》2000,125(12):2322-2325
A spectrofluorimetric method to determine the antibiotic moxifloxacin is proposed and was applied to pharmaceuticals, human urine and serum. The fluorimetric method allows the determination of 30-300 ng mL-1 moxifloxacin in aqueous solution containing phosphoric acid-phosphate buffer (pH 8.3) with lambda exc = 287 nm and lambda em = 465 nm. Detection and quantification limits were 10 and 30 ng mL-1, respectively, with a relative standard deviation (n = 10) of 2%. This method was applied to the determination of moxifloxacin in three Spanish commercial pharmaceutical formulations. Another variant of the method in micellar medium allows the direct measurement of moxifloxacin in human serum and urine by standard additions. The enhanced fluorescence of moxifloxacin in 8 mM sodium dodecyl sulfate (SDS) solution at pH 4.0 (acetic acid-acetate buffer) for lambda exc = 294 nm and lambda em = 503 nm shows the same linear range as the aqueous method with a 25% lower slope (with detection and quantification limits of 15 and 60 ng mL-1, respectively, and a relative standard deviation of 1.3%), but permits the background fluorescence for urine and serum blanks to be minimized. Hence, sufficient sensitivity is reached to determine therapeutic concentrations of the drug in urine (average recovery 102 +/- 2%) and serum (average recovery 105 +/- 2%) samples.  相似文献   

2.
Nanosecond (lambda exc = 266, 355 and 532 nm) and picosecond (lambda exc = 355 nm) laser flash photolysis of hematoporphyrin (Hp) was performed in neutral (pH 7.4) and alkaline (pH 12) aqueous solution, as well as in the presence of 0.1% Triton X-100. The dependence of the yield of photoproduced hydrated electrons (e-aq) on laser pulse energy was studied over a wide range of energies (0.2 to greater than 1000 mJ cm-2). The results show that e-aq are predominantly formed in a two-photon process at lambda exc = 266 and 355 nm. One-photon quantum yields are higher at lambda exc = 266 nm than at lambda exc = 355 nm. Both one-photon and two-photon pathways are less efficient at higher Hp concentration, reflecting the influence of Hp self-aggregation. Two-photon e-aq formation is more efficient when 30 ps pulses are used for excitation, as compared to 10 ns pulses. No e-aq could be detected at lambda exc = 532 nm. Nanosecond pulse-induced transient spectra obtained at pH 7.4 are also discussed.  相似文献   

3.
A method for the residue analysis of the veterinary antimicrobial agent enrofloxacin and its active desethyl metabolite ciprofloxacin in chicken muscle tissue has been developed and validated. The detection of the analytes was performed by laser-induced fluorescence (LIF) detection using a HeCd laser (lambda(ex) = 325 nm) providing an enhancement in sensitivity and selectivity compared to conventional UV detection. The assay has been validated with satisfying results. The limits of quantification for enrofloxacin and ciprofloxacin were 5 microg/kg and 20 microg/kg, respectively, with a fivefold preconcentration yielded by a sample clean-up with a simple liquid-liquid extraction procedure. Calibration graphs were linear from 5 to 1000 microg/kg for enrofloxacin and from 20 to 1000 microg/kg for ciprofloxacin. The assay allows the detection of contaminated muscle samples at the required maximum residue limit of the European Union, which is 100 microg/kg for the sum of enrofloxacin and ciprofloxacin.  相似文献   

4.
Pulgarín JA  Molina AA 《Talanta》2002,56(3):557-564
A method for the determination of salicylamide at concentrations between 25 and 350 ng ml(-1) by use of matrix isopotential synchronous fluorescence spectrometry (MISF) in combination with derivative techniques is proposed. The method allows the determination of compounds in samples with unknown background fluorescence without the need for tedious pre-separation. Synchronous scans are performed along a trajectory that connects points of identical intensity in a three-dimensional fluorescence spectrum. The unknown analytical signal of the serum is suppressed from the MISF spectrum, by calculating its first derivative at lambda(exc)=324 nm and lambda(em)=392 nm. In order to ensure maximum sensitivity and adequate selectivity, the experimental variables affecting the fluorescence intensity of the salicylamide band at lambda(exc)=328 nm and lambda(em)=418 nm were studied. Based on the results, the determination was performed in an aqueous medium at pH 12 that was adjusted with a sodium phosphate/hydrogen phosphate buffer. Calibration graphs were subjected to a comprehensive statistical analysis. The error propagation has been considered in order to calculate the detection limit by the criterium of Clayton.  相似文献   

5.
Increasing resistance of many antibiotics has made the design of new drugs necessary. To assist a target-oriented search for new structures and for the elucidation of the mode of action of existing drugs, powerful analytical techniques are required. In this work, vibrational spectroscopy is used to shed more light on the as-yet elusive interaction of gyrase inhibitors of the fluoroquinolone type with their biological target inside the Gram-positive bacterium Staphylococcus epidermidis by investigating whole-cell changes that occur as a result of the presence of the drug moxifloxacin. IR absorption and Raman spectra with excitation off resonance (lambda exc = 532 nm) and in resonance with the biological targets DNA and the aromatic amino acids of gyrase (lambda exc = 244 nm) were recorded for unperturbed bacteria and bacteria in varying drug concentrations (0.08, 0.16, 0.27, and 0.62 microg moxifloxacin/mL bacterial culture). The spectral changes caused by the action of the drug were analyzed with the help of statistical methods, such as hierarchical cluster analysis (HCA), principal component analysis (PCA), and Fisher's linear discriminant analysis (LDA) combined with variable selection. The wavenumbers mostly affected by the action of the drug could be assigned to protein and DNA moieties, supporting the proposed mechanisms of a tertiary complex of the fluoroquinolone, the enzyme gyrase, and DNA.  相似文献   

6.
A rapid, simple, and highly sensitive second derivative synchronous fluorometric method has been developed for the simultaneous determination of metoclopramide (MT) and pyridoxine (PY) in a binary mixture. The method is based on measurement of the native fluorescence of these drugs at delta lambda = 80 nm in methanol. The different experimental parameters affecting the native fluorescence of the drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges of 0.02-0.4 and 0.1-2 microg/mL for MT and PY, respectively. The limits of detection were 0.003 and 0.007 microg/mL and the limits of quantification were 0.008 and 0.02 microg/mL for MT and PY, respectively. The proposed method was successfully applied to the determination of MT and PY in synthetic mixtures and in commercial syrup. The results were in good agreement with those obtained with a reported method. The high sensitivity attained by the proposed method allowed the determination of MT in spiked and real human plasma samples. The mean percent recoveries of MT from spiked and real human plasma (n = 3) were 93.72 +/- 3.15 and 89.72 +/- 2.19 respectively.  相似文献   

7.
Two photon excited (TPE) fluorescence detection was applied to native fluorescence detection of aromatics in microchip electrophoresis (MCE). This technique was evaluated as an alternative to common one photon excitation in the deep UV spectral range. TPE enables fluorescence detection of unlabeled aromatic compounds, even in non-deep UV-transparent microfluidic chips. In this study, we demonstrate the proof of concept of native TPE fluorescence detection of small aromatics in commercial microfluidic glass chips. Label-free TPE fluorescence detection of native proteins and small aromatics in MCE was achieved within the micromolar concentration range, utilising 420 nm excitation light.  相似文献   

8.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection (lambda(ex) = 280 nm; lambda(em) = 410 and 312 nm) in combination with a post-column on-line photochemical derivatization is described for the determination of equilin and equilenin in urine from normal postmenopausal women after therapy with conjugated oestrogens. The column effluents were subjected on-line to UV irradiation (254 nm) and the photo-induced modifications were useful for the identification of the analytes. The conjugated (sulphate and glucuronide) forms were analysed after enzymatic or chemical hydrolysis and extracted with chloroform. Solid-phase extraction using strong anion-exchange sorbent was applied to the analysis of unconjugated oestrogen fraction to obtain a practical and reliable sample clean-up. The HPLC separations were achieved using ODS columns with a mobile phase consisting of 0.05 M triethylamine phosphate buffer (pH 4.0)-acetonitrile (64:36, v/v) at a flow rate of 1.0 mL/min. The method was accurate and reproducible; for the equilin and equilenin separation isocratic conditions were satisfactory, allowing a sensitive detection in urine samples with a detection limit of about 50 fmol for equilin (lambda(ex) = 280 nm; lambda(em) = 312 nm, after photoderivatization) and 10 fmol for equilenin (lambda(ex) = 280 nm; lambda(em) = 410 nm).  相似文献   

9.
Shi B  Huang W  Cheng J 《Electrophoresis》2007,28(10):1595-1600
A sensitive fluorescence detection system with an Hg-lamp as the excitation source and a photon counter as the detector for microchip CE (MCE) has been developed. O-Phthaldialdehyde (OPA, lambda(ex) = 340 nm) was employed to label the catecholamine neurotransmitters such as dopamine (DA), norepinephrine (NE), and amino acid neurotransmitters including alanine (Ala), taurine (Tau), glycine (Gly), glutamic acid (Glu), and aspartic acid (Asp). The separation of seven derivatized neurotransmitters was successfully performed in MCE and the detection limits (S/N = 3) for DA, NE, Ala, Tau, Gly, Glu, and Asp were 0.85, 0.49, 0.23, 0.15, 0.13, 0.18, and 0.29 fmol, respectively. The system was then successfully applied for separation and determination of neurotransmitters in rat pheochromocytoma (PC 12) cells, and the average amounts of analyte per cell from a cell population were 2.5 fmol for DA, 3.3 fmol for Ala, 8.2 fmol for Tau, 4.0 fmol for Gly, and 1.9 fmol for Glu, respectively. By single-cell injection mode, electrophoresis separation and quantitative measurement of Glu in individual PC 12 cells was obtained. The average value of Glu per cell from single PC 12 cells analysis was found to be 3.5 +/- 3.1 fmol.  相似文献   

10.
An enantioselective method for baclofen (4-amino-3-p-chlorophenylbutyric acid) based on capillary electrophoresis (CE) separation and laser-induced fluorescence (LIF) detection has been developed. Naphthalene-2,3-dicarboxaldehyde (NDA) was used for precolumn derivatization of the nonfluorescent drug. alpha-Cyclodextrin (alpha-CD) was included in the buffer as a chiral selector for the separation of NDA-labeled S-(+)- and R-(-)-baclofen. Optimal resolution and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH 9.5) containing 7 mM alpha-CD and a He-Cd laser (lambda ex = 442 nm, lambda em = 500 nm). Combined with a simple cleanup procedure, this method can be applied to the analysis of baclofen enantiomers in human plasma. The relative standard deviation (RSD) values on peak areas of a plasma sample containing 1.0 microM racemic baclofen were 6.4 and 4.9% (n = 8) for the S-(+)- and R-(-)-enantiomer, respectively. The RSD value on migration times of both enantiomers was 0.5% (n = 8). Calibration graphs for S-(+)- and R-(-)-baclofen in plasma showed a good linearity (r > or = 0.999) in the concentration range of 0.1-2.0 microM. The limit of detection of baclofen in plasma was about 10 ng/mL.  相似文献   

11.
A method has been developed for the quantitation of the antiepileptic drug vigabatrin (VGB) in human plasma. It is based on CE with LIF detection. The effect of the pH of the buffer and of N-methylglucamine (GLC) as BGE constituent was investigated. The final BGE consisted of 50 mM borate buffer, pH 9.0, with 100 mM GLC and enabled separation within 12 min at 20 kV voltage. An SPE procedure was used for the pretreatment of biological samples, based on mixed-mode lipophilic-cation exchange cartridges, followed by a derivatization step with 6-carboxyfluorescein-N-succinimidyl ester (CFSE). Fluorescence was excited by an Ar-ion laser (lambda(exc) = 488 nm). Linearity was observed in the 10-120 microg/mL plasma concentration range. Extraction yield was >96%, precision (expressed as RSD) <6.7% and accuracy (recovery) was between 97.0 and 101.6%. The method has been successfully applied to the analysis of VGB in plasma of epileptic patients undergoing therapy with the drug.  相似文献   

12.
A method for the simultaneous determination of codeine and pyridoxine was developed, based on the measurement of their native fluorescence signals, by using first-derivative spectrofluorimetry to resolve the mixture. Codeine was measured at lambda(em) = 309 nm, and pyridoxine was measured at lambda(em) = 450 nm. Instrumental parameters were optimized, and the emission spectra were recorded between 275 and 475 nm, at lambda(ex) = 255 nm and excitation and emission slit widths of 2.5 and 10 nm, respectively. Systematic studies on the influence of species usually present along with the analytes (such as caffeine, ascorbic acid, paracetamol, and thiamine) were also performed. The calibration graphs were linear over the ranges of 0.5-7.0 and 0.1-1.0 microg/mL for codeine and pyridoxine, respectively, and the relative standard deviations (n = 10) were about 3%. The method was successfully applied to the determination of codeine and pyridoxine in solutions of synthetic mixtures and in synthetic and semisynthetic pharmaceutical formulations.  相似文献   

13.
Beale SC  Hsieh YZ  Savage JC  Wiesler D  Novotny M 《Talanta》1989,36(1-2):321-325
3-Benzoyl-2-quinolinecarboxaldehyde has been synthesized and characterized for use as a precolumn fluorogenic reagent for the ultrahigh sensitivity determination of primary amines by micro-column liquid chromatography with laser-induced fluorescence detection. The reaction conditions and the spectral properties of the derivatives were investigated with standard amino-acids. The detection limits, with an HeCd laser operated at 442 nm, are in the low femtogram range. The linear dynamic range is at least three orders of magnitude. The separation of a standard amino-acid mixture and the high-sensitivity analysis of a hydrolysed protein sample are demonstrated.  相似文献   

14.
Resveratrol and its 3-glucoside (piceid), are stilbene-like molecules produced by plants. Both of them are weakly fluorescent, but highly fluorescent compounds are obtained when their hydroethanolic solutions are UV-irradiated, which implies a substantial improvement in the sensitivity of analytical methods. Experimental design (central composite design) together with the response surface methodology have been used to find optimum conditions for the fast, sensitive, and precise chromatographic analysis (with isocratic elution) of resveratrol and piceid in wine samples. These compounds have been UV-transformed into their respective photoproducts, which have been separated in a C18 column (Novapack C(18) 150x3.9 mm, 4 microm) by isocratic elution, using a mobile phase made up of acetonitrile and 4.1 vol% aqueous acetic acid, 19:81 v/v, at a flow rate of 0.8 mL/min, and fluorimetrically detected at 364 nm (lambda(exc) = 260 nm). Detection limits (S/N = 3) are 0.29 and 0.28 microg/L for resveratrol and piceid, respectively. The method has been applied to the analysis of these compounds in wine samples without a clean-up step. The analysis is completed in only 20 min. The standard addition method has been applied to the analysis of a commercial red wine and average recoveries near 100% were obtained for resveratrol and piceid. Three wine pools were satisfactorily analysed by external calibration.  相似文献   

15.
A simple and sensitive HPLC method has been developed for the determination of danofloxacin (DAN) in plasma. Sample preparations were carried out by adding phosphate buffer (pH 7.4, 0.1 M), followed by extraction with trichloromethane. DAN and the internal standard, sarafloxacin (SAR), were separated on a reversed-phase column, and eluted with aqueous solution-acetonitrile (80:20 v/v). The fluorescence of the column effluent was monitored at lambda(ex) = 338 and lambda(em) = 425 nm. The retention times were 2.80 and 4. 40 min for DAN and SAR, respectively. The method was shown to be linear from 1 to 1500 ng/mL (r(2) = 0.999). The detection and quantitation limit were 1 and 5 ng/mL, respectively. Mean recovery was determined as 80% by the analysis of plasma standards containing 150, 750 and 1500 ng/mL. Inter- and intra-assay precisions were 4.0% and 2.4%, respectively.  相似文献   

16.
An original capillary electrophoretic method has been developed and applied for the enantioselective analysis of the antiparkinson drug biperiden in pharmaceutical formulations, using a modified cyclodextrin as the chiral selector. Baseline enantioseparation of the racemic compound was achieved in less than 7 min using an uncoated fused silica capillary (50 μm i.d. and 48.5, 40.0 cm, total and effective length, respectively), filled with a background electrolyte consisting of a 50 mM phosphate buffer at pH 3.5 supplemented with 3% (w/v) β-cyclodextrin sulphate and applying a voltage of 20 kV, reversed polarity. Samples were injected by pressure (50 mbar, 90 s) at the cathodic end of the capillary and detection wavelength was 195 nm (bandwidth: 10 nm). A simple and fast pre-treatment procedure allowed the complete extraction of the drug from commercial formulations (sustained release tablets and ampoules for injections) without any interference from the matrix. Good linearity was found in the 1–50 μg/mL concentration range; the limit of quantitation was 1 μg/mL and the limit of detection was 0.4 μg/mL. Precision and accuracy were good, with R.S.D. values always lower than 2.8% and a mean recovery value of 101.1%. The method was suitable for the quality control of biperiden in commercial formulations.  相似文献   

17.
A general approach, still few exploited so far and never associated with microbore-LC, consisting of detection of various lipid classes (i.e. phospholipids, triglycerides, ceramides and glycosphingolipids) by non-covalent association with 1,6-diphenyl-1,3,5-hexatriene (DPH) fluorescence probe is developed. This mode of detection was coupled with non-aqueous reversed-phase microbore-LC (C18) by using classical post-column fluorescence detection. The classical LC system was first adapted to microbore-chromatography (internal diameter 1 mm) without apparatus miniaturization of the solvent delivery system and the detection cell. For this purpose, the detection parameters (probe concentration, post-column flow rate, post-column reactor length and post-column system temperature) were optimized by a central composite design (CCD) using a mixture of phosphatidylcholine (PC) species as a lipid model and DPH (lambda(ex) = 350 nm, lambda(em) = 430 nm) as a fluorescence probe. The optimal conditions of detection for the various molecular species of PC were determined for a DPH concentration of 3.35 micromol/L, a post-column flow rate of 0.5 mL/min, a reactor length of 1.4 m and a temperature of 35 degrees C. The fluorescence response was linear over a wide range of PC species from 5 microg/mL to 100 microg/mL and the lower limit of detection (signal/noise = 3) was about 1 microg/mL, that is equivalent to evaporative light scattering detection (ELSD). Others molecular species of various classes of lipids, i.e. triglycerides, ceramides and glycosphingolipids were also easily detected. Thus, this study demonstrated the versatility of the proposed system of detection which was shown to be sensitive, easy to perform, non-destructive and allowed, in contrast to ELSD, for a linear response with various polarity lipid classes.  相似文献   

18.
Merás ID  Díaz TG  Rodríguez DA 《Talanta》2008,74(4):675-682
trans-Piceid itself is weakly fluorescent, but the fluorescence signal (lambda(exc/em)=260/361nm) is greatly enhanced by UV-irradiation of its hydroethanolic solutions. Employing the photoinduced emission signal at 361nm or the amplitude of the second-derivative-photoinduced emission spectrum, between 353 and 361nm, a linear relation is found in the assayed range 5.7-31.4ngmL(-1) of trans-piceid and limits of detection of 1.7 and 2.1ngmL(-1), respectively, are obtained. A previous liquid-liquid extraction is necessary for the determination of piceid in wine. Experimental design (Central Composite Design) together with the Response Surface Methodology have been used to find optimum conditions for the extraction procedure. For this purpose, the difference between the photoinduced-fluorescence signal (lambda(exc/em)=260/361nm) of the aqueous phase, before and after being extracted, has been considered as Response Function. A tartrate buffer (pH 5.0) concentration of 0.15molL(-1) and a phase ratio of 1 are determined as optimum conditions. The amplitude of the second-derivative-emission spectrum, corresponding to the evaporated and re-dissolved organic phase, between 353 and 361nm has been employed as analytical signal. Standard addition method has been applied to the analysis of piceid in different wine samples under optimum conditions. Results of wine analysis have been satisfactorily validated by HPLC.  相似文献   

19.
A fast analytical method has been developed for the determination of nine amino acids, together with serotonin, in wine samples of different origin and vintage. The method is based on capillary electrophoresis coupled to laser-induced fluorescence detection. Separation was obtained by using a fused-silica capillary (75?μm id, 74.0?cm total length, 60.0?cm length to detector) and a background electrolyte composed of carbonate buffer (20?mM, pH 9.2), applying a 20?kV voltage. Direct hydrodynamic injection of wine samples was made after an original microwave-assisted derivatisation step with 5-(4,6-dichlorotriazinyl)aminofluorescein. Fluorescence was induced by an Ar-Ion laser, exciting at 488?nm. Good linearity (r(2) >0.9990) was obtained for all considered analytes and sensitivity was also good, with limits of detection in the 7-50?ng/mL range. The method was successfully applied for the analysis of commercial Italian wines and thus seems to be suitable for the determination of the relevant amino acids and serotonin, providing good results in terms of accuracy and precision, together with the advantage of a very fast, microwave-assisted derivatisation procedure. Future applications of the method are planned to check for wine adulterations and commercial frauds.  相似文献   

20.
A rapid, simple and sensitive synchronous specrtofluorimetric method has been developed for the simultaneous analysis of binary mixture of metoprolol (MTP) and felodipine (FDP). The method is based upon measurement of the synchronous fluorescence intensity of the two drugs at Δλ of 70 nm in aqueous solution. The different experimental parameters affecting the synchronous fluorescence intensities of the two drugs were carefully studied and optimized. The fluorescence intensity-concentration plots were rectilinear over the ranges of 0.5-10 μg/mL and 0.2-2 μg/mL for MTP and FDP, respectively. The limits of detection were 0.11 and 0.02 μg/mL and quantification limits were 0.32 and 0.06 μg/mL for MTP and FDP, respectively. The proposed method was successfully applied for the determination of the two compounds in their commercial tablets and the results obtained were favorably compared to those obtained with a comparison method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号