首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Mercury-based screen-printed electrodes (SPE) combined with square-wave anodic stripping voltammetry (SWASV) techniques for the analysis of copper, cadmium, lead, and zinc in different water samples have been applied. The detection system has been implemented in a flow cell and different experimental conditions have been tested in view of its application for in-situ monitoring. In particular, an acetate buffer together with a low chloride concentration (0.025?M NaCl) provided best performance and reproducible results. Additionally, the flow system was validated for the first time in terms of limits of detection, linearity, repeatability and recovery. Limits of detection of 2.8?µg?L?1, 4.1?µg?L?1, and 7.5?µg?L?1 for cadmium, lead and copper respectively and repeatabilities lower than 10% (as RSD) were found. Good recoveries have been obtained for the three cations and in particular for copper, even in the presence of zinc. Finally, the method has shown its efficiency for the rapid screening of lead, cadmium and copper contained in both natural waters and wastewater samples.  相似文献   

2.
Cysteamine core polyamidoamine G-4 dendron branched with β-cyclodextrins was chemisorbed on the surface of Au electrodes and further coated with Pt nanoparticles. Adamantane-modified glucose oxidase was subsequently immobilized on the nanostructured electrode surface by supramolecular association. This enzyme electrode was used to construct a reagentless amperometric biosensor for glucose, making use of the electrochemical oxidation of H2O2 generated in the enzyme reaction. The amperometric response of the biosensor was rapid (6 s) and a linear function of glucose concentration between 5 and 705 μmol?L?1. The biosensor had a low detection limit of 2.0 μmol?L?1, sensitivity of 197 mA?mol?1?L?cm?2, and retained 94 % of its initial response after storage for nine days at 4 °C.  相似文献   

3.
A surface plasmon resonance (SPR) based biosensor for glucose is presented in which a thin gold film modified with polypyrrole and glucose oxidase (PPy-GOx) acts as the sensor chip. It is based on SPR response to the change of refractive index of PPy-GOx film by the enzymatic catalytic reaction. The co-electropolymerization of pyrrole and GOx was carried out under cyclic voltammetric conditions, and simultaneously monitored by in-situ SPR. It has been revealed that the enzymatic reaction between GOx and PPy in the presence of glucose can lead to distinct changes in the SPR signal. From the experiments, a linear relationship was obtained in the range 1–100 μmol L?1 between glucose concentration and the rate of redox transformation of PPy. The detection limit was 0.5 μmol L?1 (S/N?=?3) and recoveries were 95.2–102.7%.  相似文献   

4.
A novel inhibition-based glucose oxidase (GOx) biosensor for environmental chromium(VI) detection is described. An electropolymerized aniline membrane has been prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx is cross-linked by glutaraldehyde. The mechanism of the redox reaction on the electrode and the performance of the sensor are studied. The sensor's response to glucose decreases when it is inhibited by chromium(VI), with a lower detection limit of 0.49?µg?L?1, and the linear response range is divided into two parts, one of which is 0.49–95.73?µg?L?1 and the other is 95.73?µg?1 to8.05?mg?L?1. The enzyme membrane is shown to be completely reactivated after inhibition, retaining 90% activity over more than forty days. Interference to chromium(VI) determination from lead(II), copper(II), cadmium(II), chromium(III), cobalt(II), tin(II) and nickel(II) is found to be minimal, while high concentrations of mercury(II) and silver(I) may interfere with the determination of trace chromium(VI). The sensor has been used for chromium(VI) determination in soil samples with good results.  相似文献   

5.
The authors describe a method for the trace determination of copper (II) and lead (II) in water and fish samples using solid-phase extraction via siliceous mesocellular foam functionalised by dithizone. Siliceous mesocellular was functionalised with dithizone, and the resulting sorbent was characterised by scanning electron microscopy, surface area analysis, thermogravimetric/differential thermal analysis and FTIR. Following solid-phase extraction of target ions by the sorbent, copper and lead ions were quantified by flame atomic absorption spectrometry. Factors affecting the sorption and desorption of target ions by the sorbent were evaluated and optimised. The calibration plot is linear in the 1 – 500 μg L?1 copper (II) and 3–700 μg L?1 lead (II) concentration range. The relative recovery efficiency in real sample analysis is in the range from 96 to 102%, and precision varies between 1.7 and 2.8%. It is should be noted that the limits of detection for the copper and lead analysis were 0.8 and 1.6 μg L?1, respectively. Also, the adsorption capacities for copper and lead ions were 120 and 160 mg g?1, respectively. The obtained pre-concentration factor for the lead and copper ions by the proposed solid-phase extraction was 75. The method was successfully applied to the determination of low levels of copper (II) and lead (II) in tap, Caspian sea, Persian gulf and lake water and also their detection in fish samples.  相似文献   

6.
Square wave anodic stripping voltammetry was used in simultaneous determinations of eco-toxic metals (Pb, Cd, Cu and Zn) on bismuth film electrodes. The electrodes were prepared in situ on a glassy-carbon electrode (GCE) from 0.1 M acetate buffer (pH 4.5) containing 200 μg L?1 of bismuth (III), as well ex situ on electrochemically oxidized graphitized polyacrylonitrile carbon fibres from 200 mg L?1 Bi(NO3)3 in 1% HNO3 (aqueous) solution. Preparation of a Bi-modified carbon fibre electrode (CFE) was by cation exchange of Bi+3 ions for H+ of the acidic surface groups of the electro-oxidized carbon fibres, followed by electrochemical reduction to Bi0. For the Bi-GCE the linear range was 20–280 μg L?1 for zinc, 10–100 μg L?1 for lead, 10–80 μg L?1 for copper, and 5–50 μg L?1 for cadmium. For the Bi-CFE it was 20–160 μg L?1 for zinc, 10–100 μg L?1 for lead, 10–100 μg L?1 for copper, and 2–120 μg L?1 for cadmium. For both kinds of bismuth modified carbon electrodes, low limits of detection and satisfactory precision were achieved. The method was successfully applied to certified reference materials of biological (bovine liver) and environmental (mussel tissue) importance.   相似文献   

7.

Silver nanoparticles enhanced glucose oxidase electrodes were prepared on the basis of chitosan matrix. The enzyme electrodes exhibited high sensitivity and excellent response performance to glucose with a linear range from 1×10?6 to 8×10?3 mol · L?1. And the time reaching the steady‐state amperometric response was less than 5 seconds. The inhibition percentage of this enzyme electrode against copper ions concentration was linear ranging from 1.2×10?6 to 5×10?5 mol · L?1. These properties of enzyme electrodes are probably due to the excellent electron transfer of silver nanoparticles and the orientation of glucose oxidase molecule.  相似文献   

8.
《Analytical letters》2012,45(5):761-777
This article reviews the use of square wave anodic stripping voltammetry for the simultaneous determination of ecotoxic metals (Pb, Cd, Cu, and Zn) on a bismuth-film (BiFE) electrode. The BiFE was prepared in situ on a glassy-carbon electrode (GCE) from the 0.1 mol L?1 acetate buffer solution (pH 4.5) containing 200 µg L?1 of bismuth (III). The addition of hydrogen peroxide to the electroanalytical cell proved beneficial for the interference-free determination of Cu (II) together with zinc, lead, and cadmium, using the BiFE. The experimental variables were investigated and optimized with the view to apply this type of voltammetric sensor to real samples containing traces of these metals. The performance characteristics, such as reproducibility, decision limit (CCa), detection capability (CCβ), sensitivity, and accuracy indicated that the method holds promise for trace Cu2+, Pb2+, Cd2+, and Zn2+ levels by employment of Hg-free GCE with SWASV. CCa, and CCβ were calculated according to the Commission Decision of 12 August 2002 (2002/657/EC). Linearity was observed in the range 20–280 µg L?1 for zinc, 10–100 µg L?1 for lead, 10–80 µg L?1 for copper, and 5–50 µg L?1 for cadmium. Using the optimized conditions, the stripping performance of the BiFE was characterized by low limits of detection (LOD). Finally, the method was successfully applied in real as well as in certified reference water samples.  相似文献   

9.
《Analytical letters》2012,45(4):395-407
A screen-printed electrode sensor has been fabricated by modifying the carbon ink surface with different brands of multiwall carbon nanotubes (MWCNTs) and bismuth film (BiF) for the determination of traces of lead, cadmium and zinc ions by square wave anodic stripping voltammetry. The MWCNTs, from three different sources, were functionalized and dispersed in Nafion (MWCNT-Nafion) solution and placed on screen printed electrodes (MWCNT-Nafion/SPE); bismuth films were then prepared by ex-situ plating of bismuth onto the MWCNT-Nafion/SPE electrodes. The electrochemical characteristics of BiF/MWCNT-Nafion/SPE/ were examined by electrochemical impedance spectroscopy and showed differences; the charge transfer resistance tends to decrease with negative applied potentials. After optimizing the experimental conditions, the square-wave peak current signal is linear in the nmol L?1 range. The lowest limit of detection found for the separate determination of lead, cadmium and zinc were 0.7 nmol L?1, 1.5 nmol L?1, and 11.1 nmol L?1, respectively, with a 120 s deposition time.  相似文献   

10.
《Analytical letters》2012,45(7):1139-1149
A novel electrochemical glucose biosensor was prepared by combining platinum nanoparticle doped Santa Barbara Amorphous Material 15 with glucose oxidase. The resulting material demonstrated high stability and reactivity for catalyzing glucose electrolytic oxidation, primarily due to the high surface area of these catalysts. This glucose biosensor was capable of interference-free determination of glucose with a linear dynamic range from 0.03 to 12.0 mmol L?1. In addition, it has the advantages of simple preparation and good stability. The reported method is promising for the determination of glucose in human serum.  相似文献   

11.
A stepwise strategy is reported for the design of a meditor-free amperometric tyrosinase biosensor. It is based on the azide-alkyne click reaction and carbodiimide coupling. Firstly, azide-terminated alkane thiols monolayers were self-assembled on the Au electrode surface. Then, nitrophenyl groups were covalent attached to the self-assembled monolayers (SAMs) via the click reaction of copper(I)-catalyzed 1,3-dipolar cycloadditions of azide-alkyne. Finally, the nitrophenyl group terminated SAMs were converted to aminophenyl-terminated interface by electrochemical reduction, and tyrosinase was covalent immobilized onto the Au electrode via carbodiimide reaction. Based on the stepwise strategy, a meditor-free amperometric tyrosinase biosensor was farbricated, and it showed good electrocatalytic reduction ability toward phenol, pyrocatechol and m-Cresol. Their linear ranges were over the range of 0.2 to 15.0 μmol·L?1, 0.2 to 73.0 μmol·L?1, and 0.2 to 33.0 μmol·L?1, respectively.  相似文献   

12.
《Analytical letters》2012,45(12):1962-1977
A field survey was conducted to investigate the metal contamination in coal gangue, soils, and crops (rice and soybeans), and to evaluate the possible health risks to the local population through food chain transfer near a coal gangue pile in the Guqiao Coal Mine, China. Contamination levels of zinc, lead, cadmium, and copper in coal gangue, soils, and crops were measured, and bio-accumulation factors from soil to crops were determined; the health risks were calculated accordingly. Results showed that both coal gangue and soil contained high levels of cadmium (0.15 mg kg?1and 0.20 mg kg?1) exceeding the background value of the soil. The lead soil concentration was low (9.99 mg kg?1), but lead in rice (0.38 mg kg?1) exceeded the maximal permissible limit of 0.2 mg kg?1. For some tissues of crops studied, there was a significant correlation between the bio-accumulation factor values and the corresponding soil metal concentrations that were best described by a power equation. Oral intake of zinc, cadmium, and copper through crops posed no health risk to local residents, although hazard indices for rice (0.87–2.88) and soybeans (0.06–0.09) suggested that ingestion of rice grains was unsafe for human health. Therefore, rice was inappropriate to be planted in the soil surrounding this coal mine.  相似文献   

13.
《Analytical letters》2012,45(7):1158-1172
Abstract

A disposable glucose biosensor is developed by immobilizing glucose oxidase into silver nanoparticles-doped silica sol-gel and polyvinyl alcohol hybrid film on a Prussian blue-modified screen-printed electrode. The silver nanoparticles-enhanced biosensor shows a linear amperometric response to glucose from 1.25 × 10?5 to 2.56 × 10?3 with a sensitivity of 20.09 mA M?1 cm?2, which is almost double that of the biosensors without silver nanoparticles. The immobilized glucose oxidase retained 91% of its original activity after 30 days of storage in phosphate buffer (pH 6.9; 0.1 M) at 4°C. Blood glucose in a rabbit serum sample was successfully measured with the biosensor.  相似文献   

14.
《Analytical letters》2012,45(9):1430-1441
A new column loaded with modified silica gel-chitosan is proposed as a preconcentration system for adsorption of trace cadmium (II) and copper (II). The optimization steps were performed under dynamic conditions, involving pH, sample flow rate, eluent selection, concentration, volume, and flow rate. Trace Cd(II) and Cu(II) were quantitatively adsorbed by the modified silica gel-chitosan. The metal ions adsorbed on the separation column were eluted with 0.1 M HNO3 and determined by flame atomic absorption spectrometry. Under the optimum conditions, this method allowed the determination of cadmium and copper with limits of detection (LOD) of 20 ng L?1 and 38 ng L?1, respectively. The relative standard deviation values (RSDs) for 1.0 mg L?1 of cadmium and 1.0 mg L?1 of copper were 2.62% and 2.85%, respectively.  相似文献   

15.
Disposable screen-printed carbon arrays modified with gold nanoparticles (AuNPs) are described. The AuNP-modified screen-printed carbon arrays, designated as AuNP-SPCE arrays, were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. The AuNP-SPCE arrays display excellent electrocatalytic activity towards lead and copper. Two well-defined and fully resolved anodic stripping peaks, at 20 mV for Pb(II) and at 370 mV for Cu(II), both vs. Ag/AgCl, can be seen. Square wave anodic stripping voltammetry was used to simultaneously analyze Pb(II) and Cu(II) in their binary mixtures in tap water. The linear working range for Pb(II) extends from 10 μg.L?1 to 100 μg.L?1 with a sensitivity of 5.94 μA.μg?1.L.cm?2. The respective data for Cu(II) are a working range from 10 μg.L?1 to 150 μg.L?1 with a sensitivity of 3.52 μA.μg?1.L.cm?2. The limits of detection (based on 3× the baseline noise) are 2.1 ng.L?1 and 1.4 ng.L?1, respectively. In our perception, this array is particularly attractive because Pb(II) and Cu(II) can be determined at rather low working potentials which makes the method fairly selective in that it is not significantly interfered by other electroactive species that require higher reduction potentials.
Graphical abstract Fabrication, characterization and electrochemical behavior of gold nanoparticles modified screen-printed carbon arrays towards lead and copper in tap water.
  相似文献   

16.
In this study, a novel adsorbent from a mesoporous family (MCM-41) coating with CoFe2O4 and piperazine was synthesized by a simple and easy route. Its application for simultaneous preconcentration of three heavy metals including lead, cadmium and copper in real samples followed by a flame atomic absorption spectroscopy was investigated. The central composite design was employed for investigating the most effective factors of pH, amount of adsorbent, the equilibrium time and their interactions. Under the optimum conditions, the detection limits for lead, cadmium and copper were 0.50, 0.30 and 0.25 μg L?1, respectively, and the preconcentration factor (PF) was 33. The presented method was successfully employed for the simultaneous determination of the three mentioned heavy metals in real samples with recoveries of 90%–105%. The accuracy of the suggested methods was also investigated through spiking samples and a reasonable range for recoveries from 90.3% to 107% was acquired. The isotherm models and thermodynamic parameters have also been studied. The new adsorbent showed fast adsorption kinetics within 10 min and maximum Langmuir monolayer capacities of 238.09, 178.57 and 208.33 mg g?1 for lead, cadmium and copper, respectively.  相似文献   

17.
《Analytical letters》2012,45(11):2285-2295
Abstract

Multi‐walled carbon nanotubes (MWNTs) were used as sorbent for flow injection (FI) on‐line microcolumn preconcentration coupled with flame atomic absorption spectrometry (FAAS) for determination of trace cadmium and copper in environmental and biological samples. Effective preconcentration of trace cadmium and copper was achieved in a pH range of 4.5–6.5 and 5.0–7.5, respectively. The retained cadmium and copper were efficiently eluted with 0.5 mol L?1 HCl for on‐line FAAS determination. The MWNTs packed microcolumn exhibited fairly fast kinetics for the adsorption of cadmium and copper, permitting the use of high sample flow rates up to at least 7.8 mL min?1 for the FI on‐line microcolumn preconcentration system without loss of the retention efficiency. With a preconcentration time of 60 sec at a sample loading flow rate of 4.3 mL min?1, the enhancement factor was 24 for cadmium and 25 for copper at a sample throughput of 45 h?1. The detection limits (3σ) were 0.30 and 0.11 µg L?1 for Cd and Cu, respectively. The precision (RSD) for 11 replicate measurements was 2.1% at the 10‐µg L?1 Cd level and 2.4% at the 10‐µg L?1 Cu level. The developed method was successfully applied to the determination of trace Cd and Cu in a variety of environmental and biological samples.  相似文献   

18.
We present a simplified approach for the trace screening of toxic heavy metals utilizing bismuth oxide screen printed electrodes. The use of bismuth oxide instead of toxic mercury films facilitates the reliable sensing of lead(II), cadmium(II) and zinc(II). A linear range over 5 to 150 μg L?1 with detection limits of 2.5 and 5 μg L?1 are readily observed for cadmium and lead in 0.1 M HCl, respectively. Conducting a simultaneous multi‐elemental voltammetric detection of zinc, cadmium and lead in a higher pH medium (0.1 M sodium acetate solution) exhibited a linear range between 10 and 150 μg L?1 with detection limits of 5, 10 and 30 μg L?1 for cadmium, lead and zinc respectively. The sensor is greatly simplified over those recently reported such as bismuth nanoparticle modified electrodes and bismuth film coated screen printed electrodes. The scope of applications of this sensor with the inherent advances in electroanalysis coupled with the negliable toxicity of bismuth is extensive allowing high throughput electroanalysis.  相似文献   

19.
姚慧  李楠  徐景忠  朱俊杰 《中国化学》2005,23(3):275-279
本文选用生物相容性好的壳聚糖作为基体材料,使其与戊二醛交联成网状结构包埋葡萄糖氧化酶制成电化学传感器。这种壳聚糖膜不仅可以减小葡萄糖氧化酶的流失,而且能为酶提供了适宜的微环境。用红外光谱、紫外光谱及透射电镜对膜的形态和性质进行了表征。实验结果表明该传感器具有很快的响应速度,很好的稳定性和重现性,能选择性地催化葡萄糖并测定其浓度。该传感器的制备方法简单,成本低,于冰箱中放置两周信号保持在90%以上,对葡萄糖测量的线性范围为1×10-5 - 3.4×10-3mol•L-1,当信噪比为3:1时检测限为5×10-6mol•L-1。  相似文献   

20.
The electrochemistry of glucose oxidase (GOx) immobilized on a graphite rod electrode modified by gold nanoparticles (Au-NPs) was studied. Two types of amperometric glucose sensors based on GOx immobilized and Au-NPs modified working electrode (Au-NPs/GOx/graphite and GOx/Au-NPs/graphite) were designed and tested in the presence and the absence of N-methylphenazonium methyl sulphate in different buffers. Results were compared to those obtained with similar electrodes not containing Au-NPs (GOx/graphite). This study shows that the application of Au-NPs increases the rate of mediated electron transfer. Major analytical characteristics of the amperometric biosensor based on GOx and 13 nm diameter Au-NPs were determined. The analytical signal was linearly related to glucose concentration in the range from 0.1 to 10 mmol L?1. The detection limit for glucose was found within 0.1 mmol L?1 and 0.08 mmol L?1 and the relative standard deviation in the range of 0.1–100 mol L?1 was 0.04–0.39%. The τ1/2 of V max characterizes the storage stability of sensors: this parameter for the developed GOx/graphite electrode was 49.3 days and for GOx/Au-NPs/graphite electrode was 19.5 days. The sensor might be suitable for determination of glucose in beverages and/or in food.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号