首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Coherent anti‐Stokes Raman scattering (CARS) spectroscopy of gas‐phase CO2 is demonstrated using a single femtosecond (fs) laser beam. A shaped ultrashort laser pulse with a transform‐limited temporal width of ∼7 fs and spectral bandwidth of ∼225 nm (∼3500 cm−1) is employed for simultaneous excitation of the CO2 Fermi dyads at ∼1285 and ∼1388 cm−1. CARS signal intensities for the two Raman transitions and their ratio as a function of pressure are presented. The signal‐to‐noise ratio of the single beam–generated CO2 CARS signal is sufficient to perform concentration measurements at a rate of 1 kHz. The implications of these experiments for measuring CO2 concentrations and rapid pressure fluctuations in hypersonic and detonation‐based chemically reacting flows are also discussed. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
High‐precision measurement of X‐ray spectra is affected by the statistical fluctuation of the X‐ray beam under low‐counting‐rate conditions. It is also limited by counting loss resulting from the dead‐time of the system and pile‐up pulse effects, especially in a high‐counting‐rate environment. In this paper a detection system based on a FAST‐SDD detector and a new kind of unit impulse pulse‐shaping method is presented, for counting‐loss correction in X‐ray spectroscopy. The unit impulse pulse‐shaping method is evolved by inverse deviation of the pulse from a reset‐type preamplifier and a C‐R shaper. It is applied to obtain the true incoming rate of the system based on a general fast–slow channel processing model. The pulses in the fast channel are shaped to unit impulse pulse shape which possesses small width and no undershoot. The counting rate in the fast channel is corrected by evaluating the dead‐time of the fast channel before it is used to correct the counting loss in the slow channel.  相似文献   

3.
张诗按  张晖  王祖赓  孙真荣 《中国物理 B》2010,19(4):43201-043201
Femtosecond coherent anti-Stokes Raman scattering (CARS) suffers from poor selectivity between neighbouring Raman levels due to the large bandwidth of the femtosecond pulses. This paper provides a new method to realize the selective excitation and suppression of femtosecond CARS by manipulating both the probe and pump (or Stokes) spectra. These theoretical results indicate that the CARS signals between neighbouring Raman levels are differentiated from their indistinguishable femtosecond CARS spectra by tailoring the probe spectrum, and then their selective excitation and suppression can be realized by supplementally manipulating the pump (or Stokes) spectrum with the $\pi $ spectral phase step.  相似文献   

4.
Spectral line‐by‐line shaping is a key enabler towards optical arbitrary waveform generation, which promises broad impact both in optical science and technology. In this paper, generation of optical and microwave arbitrary waveforms using the spectral line‐by‐line shaping technique is reviewed. Compared to conventional pulse shaping, significant new physics arises in the line‐by‐line regime, where the shaped pulse fields generated from one laser pulse now overlap with those generated from adjacent pulses. This leads to coherent interference effects related to the properties of optical frequency combs which serve as the source in these experiments. We explore such effects in a series of experiments using several different high‐repetition‐rate optical combs, including harmonically mode‐locked lasers and continuous‐wave lasers that are externally phase modulated either with or without the help of an optical cavity. As an application of line‐by‐line pulse shaping, we describe generation of microwave electrical arbitrary waveforms that can be reprogrammed at rates approaching 10 GHz.  相似文献   

5.
We theoretically present the nonlinear selective reflection spectroscopy of V‐type atomic system at gas‐solid interface in a pump‐probe scheme. The saturation and coherence effects are distinguished by solving Liouville equation in the absence and presence of reduced density matrix element between the two excited levels. When the coherence effect exists, two peaks appear in reflection spectroscopy with asymmetry lineshape. We investigate the dependence of reflection spectroscopy on pump field intensity, frequency detuning and coherent decay rate induced by collision between atoms. The lineshape can be explained based on reflection spectroscopy contributed from atoms with negative (before collision) and positive (after collision) velocities, single‐photon and two‐photon processes. This study is helpful for investigating quantum coherence and dynamic processes of atoms at gas‐solid interface.  相似文献   

6.
Coherent anti‐Stokes Raman scattering (CARS) microspectroscopy has demonstrated significant potential for biological and materials imaging. To date, however, the primary mechanism of disseminating CARS spectroscopic information is through pseudocolor imagery, which explicitly neglects a vast majority of the hyperspectral data. Furthermore, current paradigms in CARS spectral processing do not lend themselves to quantitative sample‐to‐sample comparability. The primary limitation stems from the need to accurately measure the so‐called nonresonant background (NRB) that is used to extract the chemically sensitive Raman information from the raw spectra. Measurement of the NRB on a pixel‐by‐pixel basis is a nontrivial task; thus, surrogate NRB from glass or water is typically utilized, resulting in error between the actual and estimated amplitude and phase. In this paper, we present a new methodology for extracting the Raman spectral features that significantly suppresses these errors through phase detrending and scaling. Classic methods of error correction, such as baseline detrending, are demonstrated to be inaccurate and to simply mask the underlying errors. The theoretical justification is presented by re‐developing the theory of phase retrieval via the Kramers–Kronig relation, and we demonstrate that these results are also applicable to maximum entropy method‐based phase retrieval. This new error‐correction approach is experimentally applied to glycerol spectra and tissue images, demonstrating marked consistency between spectra obtained using different NRB estimates and between spectra obtained on different instruments. Additionally, in order to facilitate implementation of these approaches, we have made many of the tools described herein available free for download. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.  相似文献   

7.
Several processes have to be automated in order to use graphene in future industrial applications. One of these is the detection and characterization of graphene and few‐layer graphite (FLG) flakes on a substrate. Raman spectroscopy is an ideal tool for this purpose, as it allows not only the identification of these graphitic materials on arbitrary substrates but also monitoring the quality of flakes within the sample. In this paper, we report how graphene and FLG crystallites can be automatically detected and characterized by monitoring the evolution of Raman bands. We present an algorithm that achieves this purpose and thus has special potential in industrial applications of graphene. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
The gas‐phase elimination kinetics of 2,2‐diethoxyethyl amine and 2,2‐diethoxy‐N,N‐diethylethanamine (320–380 °C; 40–150 Torr) in a seasoned reaction vessel are homogeneous, unimolecular and obey a first‐order rate law. These elimination processes involve two parallel reactions. The first gives ethanol and the corresponding 2‐ethoxyethenamine. The latter compound further decomposes to ethylene, CO and the corresponding amine. The second parallel reaction produce ethane and the corresponding ethyl ester of an α‐amino acid. The following Arrhenius expressions are given as: For 2,2‐diethoxyethyl amine For 2,2‐diethoxy‐N,N‐diethylethanamine Comparative kinetic and thermodynamic parameters of the overall, the parallel and the consecutive reactions lead to consider two types of mechanisms in terms of a concerted polar cyclic transition state structures. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
The kinetics of the gas‐phase thermal decomposition of the α‐ketoester methyl benzoylformate was carried out in a static system with reaction vessel deactivated with allyl bromide, and in the presence of the free radical inhibitor propene. The rate coefficients were determined over the temperature range of 440–481 °C and pressures from 32 to 80 Torr. The reaction was found to be homogenous, unimolecular and obey a first‐order rate law. The products are methyl benzoate and CO. The temperature dependence of the rate coefficient gives the following Arrhenius parameters: log10 k (s?1) = 13.56 ± 0.31 and Ea (kJ mol?1) = 232.6 ± 4.4. Theoretical calculations of the kinetic and thermodynamic parameters are in good agreement with the experimental values using PBE1PBE/6‐311++g(d,p). A theoretical Arrhenius plot was constructed at this level of theory, and the good agreement with the experimental Arrhenius plot suggests that this model of transition state may describe reasonably the elimination process. These results suggest a concerted non‐synchronous semi‐polar three‐membered cyclic transition state type of mechanism. The most advanced coordinate is the bond breaking Cδ+‐‐‐δ‐OCH3 with an evolution of 66.7%, implying this as the limiting factor of the elimination process. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Theoretical calculation of the kinetics and mechanisms of gas‐phase elimination of 2‐hydroxyphenethyl chloride and 2‐methoxyphenethyl chloride has been carried out at the MP2/6‐31G(d,p), B3LYP/6‐31G(d,p), B3LYP/6‐31 + G(d,p), B3PW91/6‐31G(d,p) and CCSD(T) levels of the theory. The two substrates undergo parallel elimination reactions. The first process of elimination appears to proceed through a three‐membered cyclic transition state by the anchimeric assistance of the aromatic ring to produce the corresponding styrene product and HCl. The second process of elimination occurs through a five‐membered cyclic transition state by participation of the oxygen of o‐OH or the o‐OCH3 to yield in both cases benzohydrofuran. The B3PW91/6‐31G(d,p) method was found to be in good agreement with the experimental kinetic and thermodynamic parameters for both substrates in the two reaction channels. However, some differences in the performance of the different methods are observed. NBO analysis of the pyrolysis of both phenethyl chlorides implies a C? Cl bond polarization, in the sense of Cδ+…Clδ?, which is a rate‐determining step for both parallel reactions. Synchronicity parameters imply polar transition states of these elimination reactions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Fourteen ketone/thione‐stabilized triphenylphosphonium methylides were subjected to conventional gas‐phase and flash vacuum pyrolysis (FVP). The kinetics of the first‐order thermal gas‐phase reactions of all these compounds were investigated over 360–653 K temperature range. The values of the Arrhenius log A and energy of activation of these ylides averaged 11.52 ± 0.34 s?1 and 133.20 ± 3.14 kJ mol?1, respectively. The products of sealed‐tube (static) and FVP were analyzed and compared. A mechanism is proposed to account for the products of reaction. The rate constants [k (s?1)] of the substrates at 500 K were calculated and used to substantiate the proposed mechanism of pyrolysis, and to rationalize the thermal gas‐phase reactivities of the ylides under study. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
The accuracy that can be achieved in single‐pulse pump‐probe Laue experiments is discussed. It is shown that with careful tuning of the experimental conditions a reproducibility of the intensity ratios of equivalent intensities obtained in different measurements of 3–4% can be achieved. The single‐pulse experiments maximize the time resolution that can be achieved and, unlike stroboscopic techniques in which the pump‐probe cycle is rapidly repeated, minimize the temperature increase due to the laser exposure of the sample.  相似文献   

13.
Combined X‐ray photon correlation spectroscopy (XPCS) and diffracted X‐ray tracking (DXT) measurements of carbon‐black nanocrystals embedded in styrene–butadiene rubber were performed. From the intensity fluctuation of speckle patterns in a small‐angle scattering region (XPCS), dynamical information relating to the translational motion can be obtained, and the rotational motion is observed through the changes in the positions of DXT diffraction spots. Graphitized carbon‐black nanocrystals in unvulcanized styrene–butadiene rubber showed an apparent discrepancy between their translational and rotational motions; this result seems to support a stress‐relaxation model for the origin of super‐diffusive particle motion that is widely observed in nanocolloidal systems. Combined measurements using these two techniques will give new insights into nanoscopic dynamics, and will be useful as a microrheology technique.  相似文献   

14.
The time‐correlation function formalism has been used to calculate resonance Raman cross sections, excitation profiles, and electronic absorption spectra of the OClO molecule in the gas‐phase and in different solvents like cyclohexane, chloroform, and water. The multidimensional time domain integrals that arise in these calculations have been evaluated for the case in which an X2B1Ã2A1 electronic transition takes place between displaced‐distorted‐rotated harmonic potential energy surfaces. Ab initio calculations have been performed to provide the spectroscopic constants required for the evaluation of these integrals. The calculated absorption spectra and resonance Raman cross sections have been compared with the experimental results. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
The laser excitation wavelength is an important parameter in obtaining Raman spectra from drugs‐of‐abuse. This article compares the effect of near infrared wavelengths, 785 nm, using both benchtop and portable instrumentation and benchtop 1064 nm on the Raman spectra of seized drugs‐of‐abuse, including cocaine hydrochloride, cocaine freebase (crack), methylenedioxymethamphetamine (‘ecstasy’), amphetamine, diamorphine (heroin) and cannabis. The significant benefit of using 1064 nm for the interrogation of this type of sample is highlighted. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Here, we study a low (less than 0.1 µg/ml) concentration aqueous suspension of single‐wall carbon nanotubes (SWNTs) by Raman‐induced Kerr effect spectroscopy (RIKES) in the spectral bands 0.1–10 and 100–250 cm−1. This method is capable of carrying out direct investigation of SWNT hydration layers. A comparison of RIKES spectra of SWNT aqueous suspension and that of milli‐Q water shows a considerable growth in the intensity of low wavenumber Raman modes. These modes in the 0.1–10 cm−1 range are attributed to the rotational transitions of H2O2 and H2O molecules. We explain the observed intensity increase as due to the production of hydrogen peroxide and the formation of a low‐density depletion layer on the water–nanotube interface. A few SWNT radial breathing modes (RBM)are observed (ωRBM = 118.5, 164.7 and 233.5 cm−1) in aqueous suspension, which allows us to estimate the SWNT diameters (∼2.0, 1.5, and 1 nm, respectively). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
The kinetics of the gas‐phase elimination of α‐methyl‐trans‐cinamaldehyde catalyzed by HCl in the temperature range of 399.0–438.7 °C, and the pressure range of 38–165 Torr is a homogeneous, molecular, pseudo first‐order process and undergoing a parallel reaction to produce via (A) α‐methylstyrene and CO gas and via (B) β‐methylstyrene and CO gas. The decomposition of substrate E‐2‐methyl‐2‐pentenal was performed in the temperature range of 370.0–410.0 °C and the pressure range of 44–150 Torr also undergoing a molecular, pseudo first‐order reaction gives E‐2‐pentene and CO gas. These reactions were carried out in a static system seasoned reactions vessels and in the presence of toluene free radical inhibitor. The rate coefficients are given by the following Arrhenius expressions:
  • Products formation from α‐methyl‐trans‐cinamaldehyde
  • α‐methylstyrene :
  • β‐methylstyrene :
  • Products formation from E‐2‐methyl‐2‐pentenal
  • E‐2‐pentene :
The kinetic and thermodynamic parameters for the thermal decomposition of α‐methyl‐trans‐cinamaldehyde suggest that via (A) proceeds through a bicyclic transition state type of mechanism to yield α‐methylstyrene and carbon monoxide, whereas via (B) through a five‐membered cyclic transition state to give β‐methylstyrene and carbon monoxide. However, the elimination of E‐2‐methyl‐2‐pentenal occurs by way of a concerted cyclic five‐membered transition state mechanism producing E‐2‐pentene and carbon monoxide. The present results support that uncatalyzed α‐β‐unsaturated aldehydes decarbonylate through a three‐membered cyclic transition state type of mechanism. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A homogeneous, molecular, gas‐phase elimination kinetics of 2‐phenyl‐2‐propanol and 3‐methyl‐1‐ buten‐3‐ol catalyzed by hydrogen chloride in the temperature range 325–386 °C and pressure range 34–149 torr are described. The rate coefficients are given by the following Arrhenius equations: for 2‐phenyl‐2‐propanol log k1 (s?1) = (11.01 ± 0.31) ? (109.5 ± 2.8) kJ mol?1 (2.303 RT)?1 and for 3‐methyl‐1‐buten‐3‐ol log k1 (s?1) = (11.50 ± 0.18) ? (116.5 ± 1.4) kJ mol?1 (2.303 RT)?1. Electron delocalization of the CH2?CH and C6H5 appears to be an important effect in the rate enhancement of acid catalyzed tertiary alcohols in the gas phase. A concerted six‐member cyclic transition state type of mechanism appears to be, as described before, a rational interpretation for the dehydration process of these substrates. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

19.
A biochemical characterization of pathologies in biological tissue can be provided by Raman spectroscopy. Often, the raw spectrum is severely affected by fluorescence interference. We report and compare various spectra‐processing approaches required for the purification of Raman spectra from heavily fluorescence‐interfered raw spectra according to the shifted‐excitation Raman difference spectroscopy method. These approaches cover the entire spectra‐processing chain from the raw spectra to the purified Raman spectra. In detail, we compared (1) area normalization versus z‐score normalization, (2) direct reconstruction of the difference spectra versus reconstruction of zero‐centered difference spectra and (3) collective baseline correction of the reconstructed spectra versus piecewise baseline correction of the reconstructed spectra and, finally, (4) analyzed the influence of the shift of the excitation wavelength on the quality of the reconstructed spectra. Statistical analysis of the spectra showed that – in our experiments – the best results were obtained for the z‐score normalization before subtraction of the normalized spectra, followed by zero‐centering of the difference spectra before reconstruction and a piecewise baseline correction of the pure Raman spectra. With our equipment, a wavelength shift from 784 to 785 nm provided reconstructed spectra of best quality. The analyzed specimens were different tissue types of pigs, tissue from the oral cavity of humans and a model solution of dye dissolved in ethanol. © 2015 The Authors. Journal of Raman Spectroscopy published by John Wiley & Sons Ltd.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号