首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The application of carbon isotope ratio mass spectrometry to doping control   总被引:1,自引:0,他引:1  
The administration of synthetic steroid copies is one of the most important issues facing sports. Doping control laboratories accredited by the World Anti-Doping Agency (WADA) require methods of analysis that allow endogenous steroids to be distinguished from their synthetic analogs in urine. The ability to measure isotope distribution at natural abundance with high accuracy and precision has increased the application of Gas Chromatography-Combustion-Isotope Ratio Mass Spectrometry (GC-C-IRMS) to doping control in recent years. GC-C-IRMS is capable of measuring the carbon isotope ratio (delta(13)C) of urinary steroids and confirm their synthetic origin based on the abnormal (13)C content. This tutorial describes some of the complexities encountered by obtaining valid delta(13)C measurements from GC-C-IRMS and the need for careful interpretation of all relevant information concerning an individual's metabolism in order to make an informed decision with respect to a doping violation.  相似文献   

2.
3.
The interest in compound-specific isotope analysis for product authenticity control and source differentiation in environmental sciences has grown rapidly during the last decade. However, the isotopic analysis of very polar analytes is a challenging task due to the lack of suitable chromatographic separation techniques which can be used coupled to isotope ratio mass spectrometry. In this work, we present the first method to measure carbon isotope compositions of the widely applied herbicide glyphosate and its metabolite aminomethylphosphonic acid (AMPA) by liquid chromatography coupled to isotope ratio mass spectrometry. We demonstrate that this analysis can be carried out either in cation exchange or in reversed-phase separation modes. The reversed-phase separation yields a better performance in terms of resolution compared with the cation exchange method. The measurement of commercial glyphosate herbicide samples show its principal applicability and reveals a wide range of δ13C values between ?24 and ?34 ‰ for different manufacturers. The absolute minimum amounts required to perform a precise and accurate determination of carbon isotope compositions of glyphosate and AMPA were in the sub-microgram range. The method proposed is sensitive enough to further perform the experiments that are necessary to better understand the carbon isotope fractionation associated to the natural degradation of glyphosate into AMPA. Furthermore, it can be used for contaminant source allocation and product authenticity as well.  相似文献   

4.
Honey is frequently subject to adulteration with relatively cheap high fructose corn syrup. Not only is this a serious consumer fraud but it is a major threat to the apicultural industry. Stable isotope ratio analysis using mass spectrometry may be used to detect honey that has been adulterated with high fructose corn syrup due to the fact that honey, usually from C3 plants, has a different 13C:12C ratio than high fructose corn syrup which is a C4 plant product  相似文献   

5.
Isotope-based quantitation is routinely employed in chemical measurements. Whereas most analysts seek for methods with linear theoretical response functions, a unique feature that distinguishes isotope dilution from many other analytical methods is the inherent possibility for a nonlinear theoretical response curve. Most implementations of isotope dilution calibration today either eliminate the nonlinearity by employing internal standards with markedly different molecular weight or they employ empirical polynomial fits. Here we show that the exact curvature of any isotope dilution curve can be obtained from three-parameter rational function, y = f(q) = (a0 + a1q)/(1 + a2q), known as the Padé[1,1] approximant. The use of this function allows eliminating an unnecessary source of error in isotope dilution analysis when faced with nonlinear calibration curves. In addition, fitting with Padé model can be done using linear least squares.  相似文献   

6.
A gas-tight thermal analysis system (Netzsch STA 449C Jupiter) has been connected to an isotope ratio mass spectrometer (PDZ Europa 20-20) via an interface containing an oxidizing furnace, water trap, and gas-sampling valve. Using this system, delta(13)C has been measured for CO(2) derived from the thermal decomposition of carbonate and oxalate minerals and organic materials at temperatures that correspond to different decomposition events. There is close agreement between measured and published delta(13)C values for carbonate and oxalate minerals, which have simple decarbonation reactions on heating. Cellulose and lignin-rich materials show much more complex thermal decomposition, reflecting differences in their purity and structure, and measured delta(13)C values vary with the temperature of gas sampling. Provided that measurements are made at temperatures that correspond to the decomposition of cellulose and lignin (indicated by maximum weight loss), internally consistent data can be obtained. However, measurements for cellulose and lignin are systematically enriched in delta(13)C (by up to 1.4 per thousand) with respect to those reported for reference materials, possibly due to the slower combustion kinetics (compared with EA-IRMS). Thermogravimetric analysis/isotope ratio mass spectrometry (TG-IRMS) is ideal for materials and samples for which it is not possible to use other isotopic measurement techniques, for example because of sample heterogeneity.  相似文献   

7.
A new doping control screening method has been developed, for the analysis of doping agents in human urine, using HPLC/orbitrap with in-source collision-induced dissociation and atmospheric pressure chemical ionization. The developed method allows the detection of 29 compounds, including agents with antiestrogenic activity, beta(2) agonists, exogenous anabolic steroids, and other anabolic agents. The mass accuracy of this method is better at 2 ppm using an external reference. The detection limit for all compounds tested was better than 100 pg/ml. The recoveries of most analytes were above 70%. The measured median repeatability values for doping agents included in the method at concentrations of 1 and 10 ng/ml were 21 and 17%, respectively. The relative standard deviation (RSD) of the intraday precision (n = 6) ranged from RSD = 16-22%, whereas the interday precision (n = 18), ranged from RSD = 17-26%, depending on the solute concentration investigated.  相似文献   

8.
The number of compounds and doping methods in sports is in a state of constant flux. In addition to ‘traditional’ doping agents, such as anabolic androgenic steroids or erythropoietin, new therapeutics and emerging drugs have considerable potential for misuse in elite sport. Such compounds are commonly based on new chemical structures, and the mechanisms underlying their modes of action represent new therapeutic approaches arising from recent advances in medical research; therefore, sports drug testing procedures need to be continuously modified and complementary methods developed, preferably based on mass spectrometry, to enable comprehensive doping controls. This tutorial not only discusses emerging drugs that can be categorized as anabolic agents (selective androgen receptor modulators, SARMs), gene doping [hypoxia‐inducible factor stabilizers, peroxisome‐proliferator‐activated receptor (PPAR)δ‐agonists] and erythropoietin‐mimetics (Hematide) but also compounds with potentially performance‐enhancing properties that are not classified in the current list of the World Anti‐Doping Agency. Compounds such as ryanodine‐calstabin‐complex modulators (benzothiazepines) are included, their mass spectrometric properties discussed, and current approaches in sports drug testing outlined. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
The application of the fundamental equation for isotopic dilution mass spectrometry to real samples often requires using approximations which can lead to significant errors. A new approach relating the composition of isotopic mixtures to the average mass of the mass spectral pattern is presented. The fundamental equations are completely general; they should be applicable to a wide range of problems and may provide improved accuracy and precision in some cases.  相似文献   

10.
Erythropoietin (EPO) and its recombinant analogues are suspected to be illicitly administered to horses for performance enhancing purposes and, consequently, prohibited in equine sports. Recently, a new erythropoiesis-stimulating agent, peginesatide (Omontys, formerly referred to as Hematide), belonging to the upcoming class of EPO-mimetic peptides, received approval for the treatment of anaemia in humans with chronic kidney disease on dialysis. As the pegylated dimeric peptide of approximately 45 kDa without sequence homology to EPO is not detectable by conventional EPO detection assays, specific methods are bound to be established for horse sports drug testing. Thus, by fortifying equine serum with peginesatide, an approach consisting of a proteolytic digestion with subtilisin after protein precipitation was developed, eventually targeting a proteotypic and xenobiotic pentapeptide which is easily accessible to liquid chromatography- tandem mass spectrometry analysis. The method was validated for qualitative purposes and demonstrated to be specific, precise (relative standard deviations below 14%), sensitive (limit of detection 10 ng mL(-1)) and linear. Being simple, cost-effective and readily transferable to other doping control laboratories, a mass spectrometric assay for the detection of therapeutic concentrations of peginesatide in equine serum is, in terms of preventive doping research, applicable to routine analysis shortly after approval of the drug.  相似文献   

11.
Pressure sensitive adhesive tape (brown parcel tape) is employed in a great many criminal activities such as the restraint of individuals during robbery and offences against the person, the enclosure of explosive devices and the packaging and concealment of controlled drugs. Packaging materials are ubiquitous in modern society and are produced in such vast quantities that it is increasingly difficult to distinguish between different products or to link materials to a common source. This study demonstrates the potential of stable isotope ratio mass spectrometry to characterise parcel tapes based on a number of properties. The carbon isotopic signature, derived from the substrate polymer, associated additives and adhesive is highly characteristic of a particular tape and allows samples from different sources to be readily distinguished. Further discrimination may be achieved by the incorporation of deuterium and oxygen isotopic data and by analysis of the isolated backing polymer. Recovery of intact tape from simulated forensic samples proved straightforward and the isotopic signature of the tape did not appear to be affected by adverse storage conditions.  相似文献   

12.
The discovery of the designer steroid tetrahydrogestrinone (THG) in elite athletes' doping control samples in 2003 demonstrated the availability of steroid derivatives prepared solely for doping purposes. Modern mass spectrometers utilizing electrospray ionization and collisionally activated dissociation (CAD) of analytes allow the structural characterization of steroids and their derivatization sites by the elucidation of fragmentation behaviors. A total of 21 steroids comprising either a 4,9,11-triene, a 3-keto-4-ene or a 3-keto-1-ene nucleus were investigated regarding their dissociation pathways, deuterated analogues were synthesized and fragmentation routes were postulated, permitting the identification of steroidal structures and modifications. Compounds based on a 4,9,11-triene steroid with an ethyl residue at C-13 (gestrinone analogues) generate abundant fragment ions at m/z 241 and 199, whereas the substitution of the C-13 ethyl group by a methyl residue (trenbolone analogues) results in a shift of m/z 241 to 227. Substances related to testosterone with a 3-keto-4-ene structure give rise to abundant fragment ions at m/z 109 and 97 whereas steroids with a 3-keto-1-ene nucleus eliminate the A-ring including the carbons C-1-C-4, in addition to C-19 that is proposed to migrate from C-10 to C-1 under CAD conditions.  相似文献   

13.
Since January 2006, the list of prohibited substances established by the World Anti-Doping Agency includes the antidepressant / anti-obesity drug Sibutramine. Due to its rapid degradation to its active metabolites N-desmethyl and N-bisdesmethyl Sibutramine, reference compounds were synthesized and included into an existing screening assay to allow the unambiguous determination of these metabolic products in human urine using liquid-liquid extraction followed by liquid chromatography/tandem mass spectrometry. Characteristic product ions, obtained after electrospray ionization and collision-induced dissociation, were elucidated using high resolution/high accuracy mass measurements with a hybrid linear ion trap/orbitrap mass analyzer. Based on diagnostic product ions, the extended screening procedure was validated for both Sibutramine metabolites using a triple quadrupole mass spectrometer. Items such as lower limits of detection (6-40 ng mL(-1)), recoveries (39-42%), intraday precision (low: 5.5-10.6%, medium: 4.9-5.9%), high: 12.8-16.4%) and interday precision (low: 15.0-22.8%, medium: 17.7-18.6%), high: 16.5-25.6%) were evaluated, and a clinical spot urine sample was analyzed to demonstrate the applicability of the developed assay in sports drug testing.  相似文献   

14.
A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions were optimized for a group of 22 analytes comprising 17 glucocorticosteroids, specific designer steroids such as tetrahydrogestrinone (THG) and specific beta2-agonists such as formoterol. The UPLC/TOFMS separation obtained required 5.5 min only for all the substances tested. Even the critical pair of dexamethasone and betamethasone isomers was almost completely resolved. Thanks to the over 10,000 full-width at half maximum (FWHM) mass resolution and high mass accuracy features of TOFMS 50 mDa window accurate mass chromatograms could be reconstructed for the individual analytes. Sensitive screening in human and calf urine samples fortified at the glucocorticosteroids minimum required performance limit (MRPL) of 30 microg L(-1) (human urine, sports doping) and 2 microg L(-1) (calf urine, veterinary control) could be obtained. The potential of UPLC/TOFMS for confirmatory analysis was shown by determining the accurate mass of all compounds and fragment ions upon in-source collision-induced dissociation (CID) at different energies. The exact mass measurement errors for all glucocorticosteroids were found to be within 6 ppm. Considering veterinary control, limits of detection (LOD) and limits of quantification (LOQ) were determined for most of the analytes in calf urine and found to range from 0.1 to 3.3 and from 0.4 to 4.4 microg L(-1), respectively. The method can be easily extended with other banned substances of interest, as demonstrated by the addition of 21 beta2-agonists to the original analyte mixture in urine, without causing any interferences.  相似文献   

15.
Isotope dilution mass spectrometry currently stands out as the method providing results with unchallenged precision and accuracy in elemental speciation. However, recent history of isotope dilution mass spectrometry has shown that the extent to which this primary ratio measurement method can deliver accurate results is still subject of active research. In this review, we will summarize the fundamental prerequisites behind isotope dilution mass spectrometry and discuss their practical limits of validity and effects on the accuracy of the obtained results. This review is not to be viewed as a critique of isotope dilution; rather its purpose is to highlight the lesser studied aspects that will ensure and elevate current supremacy of the results obtained from this method.  相似文献   

16.
17.
Supercritical fluid chromatography is proving to be a good separation and sample preparation tool for various analytical applications and, as such, has gained the attention of the anti-doping community. Here, the applicability of supercritical fluid chromatography hyphenated to tandem mass spectrometry for routine doping control analysis was tested. A multi-analyte method was developed to cover 197 drugs and metabolites that are prohibited in sport. More than 1000 samples were analyzed by applying a “dilute and inject” approach after hydrolysis of glucuronide metabolites. Additionally, a comparison with routinely used liquid chromatography-mass spectrometry was performed with 250 of the 1000 samples and a number of past positive anti-doping samples. It revealed some features where supercritical fluid chromatography-tandem mass spectrometry was found to be complementary or advantageous to liquid chromatography-mass spectrometry for anti-doping purposes, such as better retention of analytes that are poorly retained in reversed-phase liquid chromatography. Our results suggest that supercritical fluid chromatography-tandem mass spectrometry is sensitive (limit of detection <50% relevant minimum required performance level required by the World Anti-Doping Agency for anti-doping analysis), reproducible, robust, precise (analytes of interest area coefficient of variation <5%; retention time difference coefficient of variation <1%) and complementary to existing techniques currently used for routine analysis in the World Anti-Doping Agency accredited laboratories.  相似文献   

18.
An alternative calibration procedure for the Gas Chromatography–Combustion–Isotope Ratio Mass Spectrometry (GC–C–IRMS) measurements of the World Antidoping Agency (WADA) Accredited Laboratories is presented. To alleviate the need for externally calibrated CO2 gas for GC–C–IRMS analysis of urinary steroid metabolites, calibration using an external standard mixture solution of steroids with certified isotopic composition was investigated. The reference steroids of the calibration mixture and routine samples underwent identical instrumental processes. The calibration standards bracketed the entire range of the relevant δ13C values for the endogenous and exogenous steroids as well as their chromatographic retention times. The certified δ13C values of the reference calibrators were plotted in relation to measured m/z13CO2/12CO2 (i.e. R(45/44)) mass spectrometric signals of each calibrator. δ13C values of the sample steroids were calculated from the least squares fit through the calibration curve. The effect of the external calibration on δ13C values, using the same calibration standards and set of urine samples but different brands of GC–C–IRMS instruments, was assessed by an interlaboratory study in the WADA Accredited Laboratories of Sydney, Australia and Athens, Greece. Relative correspondence between the laboratories for determination of androsterone, etiocholanolone, 5β-androstane-3α,17β-diacetate, and pregnanediacetate means were SD(δ13C) = 0.12‰, 0.58‰, −0.34‰, and −0.40‰, respectively. These data demonstrate that accurate intralaboratory external calibration with certified steroids provided by United States Antidoping Agency (USADA) and without external CO2 calibration is feasible and directly applicable to the WADA Accredited Laboratories for the harmonization of the GC–C–IRMS measurements.  相似文献   

19.
20.
液相色谱-质谱联用在兴奋剂检测中的应用及进展   总被引:1,自引:1,他引:1  
秦旸  徐友宣  杨树民  朱绍棠 《色谱》2008,26(4):431-436
液相色谱-质谱联用技术已越来越广泛地应用在兴奋剂的检测中,其中包括对各类小分子兴奋剂和肽类激素等的检测。本文综述了近年来液相色谱-质谱联用在兴奋剂检测中的筛选、确证和定量方面的应用及进展情况,并讨论了相关的检测标准。  相似文献   