1.
The unique ability of macrocyclic ligands, such as the crown ethers and cryptands, to selectively complex alkali metal cations can be used as the basis for chromatographic separations of anions. Specifically, macrocycles which are adsorbed onto a reversed-phase column, form positively charged anion-exchange sites when they combine with eluent cations. Previously we have demonstrated gradient anion separations based on changing the column capacity during the course of the separation by altering the eluent cation, temperature, or organic modifier content using cryptand-based columns. Herein we report that excellent separations can also be achieved using 18-crown-6 based columns. In this column, anion retention increases with increasing eluent strength and organic modifier content. This observation is in keeping with the relatively moderate affinity of crown ethers for alkali metals when compared to cryptands. The separation of anions achieved by optimizing mobile phase variables shows that isocratic separations of anions on the crown-based column are almost as good as separations achieved only under gradient conditions on cryptand-based columns. Cation gradients provide additional improvements on the separations using the crown-based column.  相似文献   

2.
A 2.2.2 cryptand-based anion exchanger was recently introduced as a commercial product. This new technology relies on a covalently bonded 2.2.2 cryptand, which allows one to selectively control the capacity of the column simply by the choice of eluent. This provides the analyst with more flexibility over conventional anion exchangers to suit the needs of the sample matrix. Since that time, a 2.2.1 version has also been developed and studied. In this paper we will compare the two types of columns and choose the best one for analyzing several environmental samples.  相似文献   

3.
Anions and cations of interest for the post-blast identification of homemade inorganic explosives were separated and detected by ion chromatographic (IC) methods. The ionic analytes used for identification of explosives in this study comprised 18 anions (acetate, benzoate, bromate, carbonate, chlorate, chloride, chlorite, chromate, cyanate, fluoride, formate, nitrate, nitrite, perchlorate, phosphate, sulfate, thiocyanate and thiosulfate) and 12 cations (ammonium, barium(II), calcium(II), chromium(III), ethylammonium, magnesium(II), manganese(II), methylammonium, potassium(I), sodium(I), strontium(II), and zinc(II)). Two IC separations are presented, using suppressed IC on a Dionex AS20 column with potassium hydroxide as eluent for anions, and non-suppressed IC for cations using a Dionex SCS 1 column with oxalic acid/acetonitrile as eluent. Conductivity detection was used in both cases. Detection limits for anions were in the range 2-27.4ppb, and for cations were in the range 13-115ppb. These methods allowed the explosive residue ions to be identified and separated from background ions likely to be present in the environment. Linearity (over a calibration range of 0.05-50ppm) was evaluated for both methods, with r(2) values ranging from 0.9889 to 1.000. Reproducibility over 10 consecutive injections of a 5ppm standard ranged from 0.01 to 0.22% relative standard deviation (RSD) for retention time and 0.29 to 2.16%RSD for peak area. The anion and cation separations were performed simultaneously by using two Dionex ICS-2000 chromatographs served by a single autoinjector. The efficacy of the developed methods was demonstrated by analysis of residue samples taken from witness plates and soils collected following the controlled detonation of a series of different inorganic homemade explosives. The results obtained were also confirmed by parallel analysis of the same samples by capillary electrophoresis (CE) with excellent agreement being obtained.  相似文献   

4.
离子色谱-抑制电导法分别测定海水中阴离子和阳离子   总被引:1,自引:0,他引:1  
采用离子交换-抑制电导法测定海水中阴、阳离子。采用抑制电导可以降低淋洗液的背景电导,又可以增加被测离子的电导值,改善信噪比。采用的电化学自身再生抑制器,由连续电解水产生抑制淋洗液所需要的H^+或者OH^-,加上电场引力,能用于高客量分离柱所用的淋洗液浓度和梯度淋洗。在试验条件下,利用阴离子和阳离子分离柱,配合抑制电导检测,可以同时分离和测定海水中7种阴离子和6种阳离子。且都可以得到很好的线性和较低的检出限。  相似文献   

5.
建立了整体柱离子对色谱-紫外检测法梯度淋洗快速分离测定4种吡啶离子液体阳离子的方法。分离采用C18反相硅胶整体柱,以离子对试剂(用柠檬酸调节pH值)-乙腈为淋洗液,并采用多级梯度洗脱程序。实验考察了色谱柱、离子对试剂、乙腈浓度、色谱柱温度及流速对吡啶阳离子保留的影响,并讨论了其保留规律。咪唑阳离子的保留符合碳数规律。最佳色谱条件是:在流速3.0 mL/min,柱温30℃下,以1.0 mmol/L庚烷磺酸钠(pH 4.0)(A)+乙腈(B)为淋洗液进行梯度洗脱。淋洗梯度为0~2.0 min,10%B;2.0~2.5 min,10%~15%B;2.5~4.0 min,15%B;4.0~4.5 min,15%~20%B;4.5~10.0 min,20%B。在此条件下,4种吡啶阳离子可在7 min内基线分离。所测阳离子的检出限(S/N=3)为0.05~0.17 mg/L;峰面积的相对标准偏差(n=5)小于0.6%。将本方法用于实验室合成的离子液体样品和污水样品的分析,加标回收率在95.7%~99.0%之间。本方法准确、快速,具有较好的实用性。  相似文献   

6.
Liu Y  Mou S 《Talanta》2003,60(6):1205-1213
A method was developed for the quantitative determination of inorganic cations and anions present in liquid crystal materials pretreated with ultraviolet irradiation by ion chromatography. The samples were irradiated at less than 20±2 °C and then pretreated with OnGuard RP and P cartridges to remove the interferential organic compounds prior to ion chromatographic analysis for both cations and anions. With a high capacity and very hydrophilic anion exchange column, four anions (fluoride, chloride, bromide, iodide) were determined in 20 min with gradient of sodium hydroxide. By employing a cation exchange column, five cations (sodium, ammonium, potassium, magnesium, calcium) could be determined in 12 min. The spiked recoveries for the cations and anions were 84.0–108.1% and 86.1–108.2%, respectively.  相似文献   

7.
Yokoyama Y  Sawaguchi N  Sato H 《The Analyst》2001,126(7):989-994
A successive non-suppressed ion chromatography (IC) system for the determination of common cations (Na+, K+, Mg2+, Ca2+) and anions (Cl-, Br-, NO3-, SO4(2-)) was developed, using two separation columns and a single eluent. 5-Sulfoisophthalic acid eluent was very suitable for such separations with a commercially available cation-exchange column for the mono- and di-valent cations and with an ODS column coated with cetyltrimethylammonium for the anions. Both cations and anions were detected with conductimetrically high sensitivity without any suppressor. After injecting an aliquot of sample solution, the solvent front from the cation-exchange column, including most of the anionic species, was firstly accumulated into the additional 2 ml accumulation loop for 60 s, while the cation IC was performed. Subsequently, the accumulated fraction was introduced into the anion-exchange column and chromatographed. Relative standard deviations (RSDs) of retention times and conductimetric area responses for common cations were within 6% and within 4%, respectively. The linear relationships between molar concentration and detector response ranged from 0.01 to 1.00 mM with r2 of 0.9994 for Na+, 0.9992 for K+, 0.9993 for Mg2+, and 0.9988 for Ca2+. The successive anion IC through the accumulating process was also quantitative, with 95% recovery or over for each analyte. The linear ranges were between 0.01 and 1.00 mM with r2 of 0.9996 for Cl-, 0.9997 for Br-, 0.9993 for NO3-, and 0.9984 for SO4(2-). The method was applied to the determination of common cations and anions in several mineral waters and a hot spring water.  相似文献   

8.
Inorganic anions and cations in environmental waters were determined by ion chromatography. Stationary and mobile phases were examined for the simultaneous separation of both anions and cations. Cations detection by UV detection requires a mobile phase with a UV absorbing additive, which indirectly visualizes cations as negative peaks. Simultaneous separation of anions and cations were achieved when using an eluent that consists of inorganic acid with weak basic amino acid as additives. It was convenient to separate both anions and cations by coupling anion-exchange and cation-exchange columns in tandem. The order of the separation columns connected affected the elution profiles. When the eluent comprises of multiple anions and a single cation, the anion-exchange column should be connected in the upper stream, whereas when the eluent comprises multiple cations and a single anion, the cation-exchange column should be connected in the upper stream. Use of switching valves also allowed simultaneous separation of anions and cations in a single chromatographic run. In the present work, operating conditions were optimized for the simultaneous separation of anions and cations.  相似文献   

9.
A 0.46 cm x 10.0 cm silica monolith column was modified through the in situ covalent attachment of lysine (2,6-diaminohexanoic acid) groups. Due to the zwitterionic nature of the resultant stationary phase, the modified monolithic column contained both cation and anion exchange capacity. In the case of cation exchange, the capacity was found to be relatively low at between 5 and 6.5 micromoles Me2+ per column. However, as expected, the lysine monolith exhibited a higher anion exchange capacity at 12-13 micromoles A- per column (at pH 3.0), which was found to be dependent upon column pH, due to the dissociation of the weak acid carboxylic acid groups. High-performance separations of transition metal cations and inorganic anions were achieved using the modified monolith, with the effects of eluent concentration, pH and flow rate evaluated. Using elevated flow rates of up to 5 mL/min the separation of nitrite, bromate, bromide, nitrate, iodide and thiocyanate was possible in approximately 100 s with peak efficiencies of between 50 and 100,000 N/m and retention time %RSD of under 0.3%.  相似文献   

10.
傅厚暾 《色谱》2001,19(6):513-515
 研究了离子色谱弱酸阴离子分析中以氢氧化钠作淋洗液时 ,弱酸阴离子的调整保留时间随淋洗液中氢氧化钠浓度变化的规律 ,建立了二者关系的非线性函数模型。将一元非线性问题转化为多元线性问题求解 ,磷酸根的调整保留值与淋洗液中氢氧化钠浓度关系回归方程的相关系数在 0 99以上。用该数学模型预测磷酸根阴离子的保留值 ,相对误差小于 5 % 。  相似文献   

11.
Complex formation between borate compounds and vicinal diols is well recognized. Generally, in a chemically bonded anion-exchange resin, many hydroxyl groups are introduced on the surface of the resin in order to make the resin hydrophilic. The borate as an eluting reagent also reacts to these hydroxyl groups, and this complex formation decreases the apparent ion-exchange capacity of the column by being dissociated to the anion depending on the eluent pH. In the present work a method is described for the simultaneous determination of anions based on the capacity gradient for suppressed ion chromatography. A Tosoh IC-Anion-PW column and dihydroxyphenylborane–mannitol eluent system were used. To maintain baseline stability, it was helpful to keep the borate concentration constant during a gradient of 16 to 0 mM mannitol as a modifier to prevent the complex formation with the hydroxyl on the resin. The chemical composition of the eluents and gradient profiles are discussed and the application to the analysis of the condensed phosphates with widely varying retention times as food additives in a cheese sample is presented.  相似文献   

12.
The International Agency for Research on Cancer determined that bromate is a potential human carcinogen, even at low micro/l levels in drinking water. Bromate is commonly produced from the ozonation of source water containing naturally occurring bromide. Traditionally, trace concentrations of bromate and other oxyhalides in environmental waters have been determined by anion exchange chromatography with an IonPac AS9-HC column using a carbonate eluent and suppressed conductivity detection, as described in EPA Method 300.1 B. However, a hydroxide eluent has lower suppressed background conductivity and lower noise compared to a carbonate eluent and this can reduce the detection limit and practical quantitation limit for bromate. In this paper, we examine the effect of using an electrolytically generated hydroxide eluent combined with a novel hydroxide-selective anion exchange column for the determination of disinfection byproduct anions and bromide in municipal and bottled drinking water samples. EPA Methods 300.1 B and 317.0 were used as test criteria to evaluate the new anion exchange column. The combination of a hydroxide eluent with a high capacity hydroxide-selective column allowed sub-microg/l detection limits for chlorite, bromate, chlorate, and bromide with a practical quantitation limit of 1 microg/l bromate using suppressed conductivity detection and 0.5 microg/l using postcolumn addition of o-dianisidine followed by visible detection. The linearity, method detection limits, robustness, and accuracy of the methods for spiked municipal and bottled water samples will be discussed.  相似文献   

13.
Some factors influencing the separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection were investigated. These factors include eluent concentration, column temperature, and detection waveform. The selectivity changes in weakly retained amino acids are slight with changing sodium hydroxide eluent concentration. When sodium acetate eluent concentration is changed, the selectivity variations between strongly retained amino acids containing two carboxyl groups and containing only one carboxyl group are obviously different. Significant but slight selectivity changes in weakly retained amino acids can be achieved through changing the column temperature. Sodium hydroxide and sodium acetate eluent concentration affect the detection of amino acids. Detection sensitivity of amino acids can be improved by increasing the concentration of sodium hydroxide and sodium acetate in a certain concentration range. The detections of amino acids at two different detection waveforms were compared. The hydroxyl amino acids can be selectively detected by choosing a modified detection waveform. The optimized gradient elution condition and column temperature for analyzing 19 amino acids were obtained. The time for the gradient elution program was 60 min. The column temperature was 35 degrees C. Under the optimized conditions, detection limits for 19 amino acids were 0.15-4.52 pmol. The calibration graphs of peak area for all the analytes were linear for about three orders of magnitude. The RSDs (n=5) of peak area were 0.6-5.6%. The determination of trace amino acid impurities in valine product is shown as an application example.  相似文献   

14.
A commercially available 4.6 mm id x 50 mm polymethacrylate-based monolithic strong anion exchange column (ProSwift SAX-1S) designed for the separation of proteins has been successfully used to separate small inorganic anions in the presence of a seawater sample matrix. Using a hydroxide eluent with suppressed conductivity detection the ion exchange capacity of this column declined over time; however, using KCl as the eluent, the column performance was stable with a capacity of 530 microequiv. for nitrate. The optimum conditions for the separation of iodate, bromate, nitrite, bromide and nitrate were assessed by constructing van Deemter plots using 1.00 and 0.100 M KCl. Efficiencies of up to 26 700 plates/m were recorded using 1.00 M KCl, at a flow rate of 0.20 mL/min but iodate was not baseline resolved from the void peak. By reducing the concentration of the eluent to 0.100 M, efficiencies of up to 39 900 plates/m could be obtained at 0.35 mL/min. By employing a linear gradient ranging from 0.05 to 1.00 M KCl the ions dissolved in distilled water or a salt water matrix could be baseline separated in less than 3 min at a flow rate of 2.50 mL/min.  相似文献   

15.
A two-dimensional ion chromatography (2D-IC) approach has been developed which provides greater resolution of complex samples than is possible currently using a single column. Two columns containing different stationary phases are connected via a tee-piece, which enables an additional eluent flow and independent control of eluent concentration on each column. The resultant mixed eluent flow at the tee-piece can be varied to produce a different eluent concentration on the second column. This allows analytes strongly retained on the first column to be separated rapidly on the second column, whilst maintaining a highly efficient, well resolved separation of analytes retained weakly on the first column. A group of 18 inorganic anions has been separated to demonstrate the utility of this approach and the proposed 2D-IC method provided separation of this mixture with resolution of all analytes greater than 1.3. Careful optimisation of the eluent profiles on both columns resulted in run times of less than 28 min, including re-equilibration. Separations were performed using isocratic or gradient elution on the first column, with an isocratic separation being used on the second column. Switching of the analytes onto the second column was performed using a gradient pulse of concentrated eluent to quickly elute strongly retained analytes from the first column onto the second column. The separations were highly repeatable (RSD of 0.01–0.12% for retention times and 0.08–2.9% for peak areas) and efficient (typically 8000–260,000 plates). Detection limits were 3–80 ppb.  相似文献   

16.
The retention and separation selectivity of inorganic anions and on-column derivatised negatively charged citrate or oxalate metal complexes on reversed-phase stationary phases dynamically coated with N-(dodecyl-N,N-dimethylammonio)undecanoate (DDMAU) has been investigated. The retention mechanism for the metal-citrate complexes was predominantly anion exchange, although the amphoteric/zwitterionic nature of the stationary phase coating undoubtedly also contributed to the unusual separation selectivity shown. A mixture of 10 inorganic anions and metal cations was achieved using a 20 cm monolithic DDMAU modified column and a 1 mM citrate eluent, pH 4.0, flow rate equal to 0.8 mL/min. Selectivity was found to be strongly pH dependent, allowing additional scope for manipulation of solute retention, and thus application to complex samples. This is illustrated with the analysis of an acidic mine drainage sample with a range of inorganic anions and transition metal cations, varying significantly in their concentrations levels.  相似文献   

17.
Ion-exclusion/anion-exchange chromatography(IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH——form with basic eluent has been developed.The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase.This system is useful for simultaneous separation and determination of ammonium ion(NH+4),nitrite ion(NO-2),and nitrate ion(NO-3) in water samples.The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column.In this study,several separation columns,which consisted of different particle sizes,different functional groups and different anion-exchange capacities,were compared.As the results,the separation column with the smaller anion-exchange capacity(TSKgel Super IC-Anion) showed well-resolved separation of cations and anions.In the optimization of the basic eluent,lithium hydroxide(LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L,considering the resolution of analyte ions and the whole retention times.In the optimal conditions,the relative standard deviations of the peak areas and the retention times of NH+4,NO-2,and NO-3 ranged 1.28%-3.57% and 0.54%-1.55%,respectively.The limits of detection at signal-to-noise of 3 were 4.10 μmol/L for NH+4,1.87 μmol/L for NO-2 and 2.83 μmol/L for NO-3.  相似文献   

18.
A new approach is described for micro-HPLC for generating nearly linear gradients in the 40 to 550 μl volume range. These “linear” gradients have a straight line middle portion with a gentle curved onset of the gradient andd rapid attainment of the final 100% composition. Such “breakthrough-gradients” are produced by the interface between weak and strong eluent when a small (3 × 0.46 cm) packed “gradient-generator” column is switched abruptly from weak to strong eluent. The model system described here, without an analytical column, shows gradients from weak eluent (water) to strong eluent (modele with water plus acetone) using a 12-port high pressure valve to 1) vent the “flush” eluent, and simultaneously 2) begin the gradient and 3) make the sample injection. The volume of the gradient can be changed in two ways. If the breakthrough-generator is packed with very large (300 to 1600 μm nonporous particles, the gradient volume is nearly independent of the flush flow rate. The flush flow is used to quickly move the breakthrough-interface to the head of the micro-HPLC column. However, the gradient volume can be increased by using larger solid particles in the gradient-generator column because of increased eddy diffusion. If the gradient-generator is packed with porous particles (75–150 μm), the gradient volume can be changed over a broad range by simply changing the flush flow rate. This simple control over the gradient volume is due to the increased mass transfer of weak eluent out of the porous particles into the strong eluent at higher flush flows. The breakthrough-interface gradient-generator column approach provides the following advantages for micro-HPLC:
  • – Gradient volumes can be readily varied over the micro-HPLC range 40–550 μl.
  • – Gradient are linear with smooth and rapid onset of intial and final concentrations.
  • – Gradient are produced inexpensively with a single high-pressure precision pump.
  • – Gradient can be automated with a timer and single 12-port valve that provides both column regeneration and sample injection.
  相似文献   

19.
The mixed-mode separation of a selection of anionic and cationic pharmaceutically related compounds is studied using ion-exchange columns and eluents consisting of ionic salts (potassium hydroxide or methanesulfonic acid) and an organic modifier (methanol). All separations were performed using commercially available ion-exchange columns and an ion chromatography instrument modified to allow introduction of methanol into the eluent without introducing compatibility problems with the eluent generation system. Isocratic retention prediction was undertaken over the two-dimensional space defined by the concentration of the competing ion and the percentage of organic modifier in the eluent. Various empirical models describing the observed relationships between analyte retention and both the competing ion concentration and the percentage of methanol were evaluated, with the resultant model being capable of describing the separation, including peak width, over the entire experimental space based on six initial experiments. Average errors in retention time and peak width were less than 6% and 27%, respectively, for runs taken from both inside and outside of the experimental space. Separations performed under methanol gradient conditions (while holding the competing ion concentration constant) were also modelled. The observed effect on retention of varying the methanol composition differed between analytes with several analytes exhibiting increased retention with increased percentage methanol in the eluent. An empirical model was derived based on integration of the observed tR vs. %methanol plot for each analyte. A combination of the isocratic and gradient models allowed for the prediction of retention time using multi-step methanol gradient profiles with average errors in predicted retention times being less than 4% over 30 different 2- and 3-step gradient profiles for anions and less than 6% over 14 different 2- and 3-step gradient profiles for cations. A modified peak compression model was used to estimate peak widths under these conditions. This provided adequate width prediction with the average error between observed and predicted peak widths being less than 15% for 40 1-, 2- and 3-step gradients for anions and less than 13% over 14 1-, 2- and 3-step gradients for cations.  相似文献   

20.
Ion-exclusion/cation-exchange chromatography with an eluent containing the bile salt-type zwitterionic surfactant CHAPS was performed in order to evaluate variations in anion (SO(4)(2-), NO(3)(-), and SCN(-)) and cation (Na(+), K(+), NH(4)(+), Mg(2+), and Ca(2+)) concentrations in human saliva. CHAPS prevents the adsorption of proteins to the stationary phase, i.e., weakly acidic cation-exchange resin, since it aggregates proteins without denaturing them. Addition of 1mM CHAPS to the eluent comprising 6mM tartaric acid and 7 mM 18-crown-6 yielded reproducible separations of anions and cations in protein-containing saliva. The resolutions of anions and cations were not significantly affected by the addition of CHAPS to the eluent. The concentrations of Na(+) and K(+) varied before and after meals; or that of SCN(-), upon smoking. The relative standard deviations of peak areas ranged from 0.3 to 5.1% in 1 day (n=20) and from 1.4 to 5.8% over 6 days (n=6).  相似文献   