首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this research, new electrodes were prepared by incorporating a new calix[4]arene derivative into a plasticized poly(vinyl chloride) matrix. Calibration plots with Nernstian slopes (29.9 ± 1.1 mV/decade) for vanadyl ion were observed over a linear range of about four decades of concentration (1.0 × 10−5 to 1.0 × 10−1 mol dm−3, at 25 °C). This electrode revealed a lower limit of detection of 3.9 × 10−6 mol dm−3. Conductometric data showed the relatively strong interaction between calix[4]arene and vanadyl ions. The results show that this electrode can be used in acetonitril and methanol media until 10% (v/v) concentration without interference. It has a short response time and can be used for more than two months without any considerable divergence in the potentials. The influence of membrane composition, the pH of the test solution, and the interfering ions on the electrode performance was investigated. The effect of temperature on the electrode response showed that the temperature higher than 50 °C deteriorates the electrode performance. The isothermal temperature coefficient of this electrode amounted to 0.0015 V °C−1. The results of application show that the electrode can be used successfully in present Cr3+ and Fe3+.  相似文献   

2.
The construction and performance characteristics of a new potentiometric PVC membrane sensor for the determination of sodium dodecyl sulfate (SDS) are described. The sensor was based on the use of an N-cetyl-N,N,N trimethyl ammonium (CTA) dodecyl sulfate (DS) ion pair as ion exchange sites in PVC matrix in the presence of o-nitrophenyl octylether as plasticiser. The sensor exhibited a fast, stable, and near-Nernstian response for SDS over the concentration range of 1 × 10?3 to 10?6 M at 25°C and the pH range 4–8.5 with anionic slope of 52.5 ± 0.5 mV decade?1. The lower detection limit was 3 × 10?6 M, and the response time was 25 s. Selectivity coefficients of SDS with respect to a number of different species were investigated. There were negligible interferences caused by most of the investigated anions. The determination of 1.0–280.0 µg mL?1 of SDS in aqueous solutions showed an average recovery of 99.1%, and the mean relative standard deviation was 1.4 at 100 µg mL?1. The results obtained in the determination of SDS in liquid soap, water and in some pharmaceutical preparations compared favourably with those obtained by the Methylene Blue active substance method (MBAS). In the present investigation, the DS sensor has been used as an end-point indicator electrode for some precipitation titration reactions, e.g. titration of SDS with CTMABr and cetylpyridinium chloride with SDS.  相似文献   

3.
Hassan SS  Attawiya AM 《Talanta》2006,70(4):883-889
A novel potentiometric uranyl membrane sensor with a divalent anionic response is developed, characterized and used for determination of uranyl ion. The sensor incorporates triethylenetetramine (TETA) as an ionophore in poly(vinyl chloride) matrix membrane (PVC) plasticized with o-nitrophenyloctyl ether (o-NPOE). In strong sulphate test solutions, UO22+ ion forms a highly stable [UO2(SO4)2]2− anion, extractable in TETA as {(2TETAH)2+ [UO2(SO4)2]2−} complex. Formation of the complex is confirmed and characterized by elemental analysis, mass spectrometry and infrared spectrometry. Sensor based on this system displays at pH 2.5-3.8 a linear response over the concentration range of 1.0 × 10−1-3.5 × 10−5 mol l−1 uranium with a near-Nernstian calibration slope of −26.5 ± 0.3 mV decade−1. The lower limit of detection is ∼5 μg ml−1, the lifetime is 12 weeks and negligible interferences are caused by most common cations. Validation of the assay method reveals excellent performance characteristics in terms of sensitivity, selectivity, fast response and potential stability. The sensor is used for the determination of 0.01-7.09 wt% uranium in naturally occurring and certified ore samples. The results show an average recovery of 97.6% and compare fairly well with data obtained using X-ray fluorescence technique.  相似文献   

4.
Four new sulfur-containing compounds based on pyridine, benzene, 1,8-naphthyridine and 1,10-phenanthroline have been synthesized. These molecules have been incorporated into a polymeric matrix as neutral carriers and evaluated as silver sensors. Two of the compounds (pyridine and benzene) show high selectivity for Ag(+). The sensor with the pyridine-based compound, in particular, shows near-Nernstian response and good sensitivity towards Ag(+) with a short response time (<10s), making it ideal for use in flow analysis.  相似文献   

5.
A novel tetrachlorothallate (III) (TCT)-selective membrane sensor consisting of tetrachlorothallate (III)-2,3,5-triphenyl-2-H-tetrazolium ion pair dispersed in a PVC matrix plasticized with dioctylphthalate is described. The electrode shows a stable, near-Nernstian response for 1×10−3-4×10−6 M thallium (III) at 25 °C with an anionic slope of 56.5±0.5 over the pH range 3-6. The lower detection limit and the response time are 2×10−6 M and 30-60 s, respectively. Selectivity coefficients for Tl(III) relative to a number of interfering substances were investigated. There is negligible interference from many cations and anions; however, iodide and bromide are significantly interfere. The determination of 0.5-200 μg ml−1 of Tl(III) in aqueous solutions shows an average recovery of 99.0% and a mean relative standard deviation of 1.4% at 50.0 μg ml−1. The direct determination of Tl(III) in spiked wastewater gave results that compare favorably with those obtained by the atomic absorption spectrometric method. The electrode was successfully applied for the determination of thallium in zinc concentrate. Also the tetrachlorothallate electrode has been utilized as an end point indicator electrode for the determination of thallium using potentiometric titration.  相似文献   

6.
Solution studies showed a selective interaction between the new synthesized ionophore, 2-[(thiophen-2-yl)methyleneamino]isoindoline-1,3-dione (TMID) and Fe(III) ion. Therefore, TMID was used as an iron selective ion-carrier in a plasticized liquid membrane sensor. The linear response range of the proposed electrode was 1.0 × 10?6–1.0 × 10?2 M. The Nernstian slope of 20.1 ± 0.3 mV/decade, and a detection limit of 5 × 10?7 M was obtained. The sensor could be used in the pH range of 2.3–4.8, and the response time was about 10 s. The lifetime of the electrode was at least 7 weeks. The sensor accuracy was investigated in two ways: (i) with the potentiometric titration of a Fe3+ solution with EDTA and (ii) with Fe(III) monitoring in some cationic mixtures. Finally, the newly fabricated electrode was effectively applied as an indicator electrode for the direct Fe3+ determination in real samples.  相似文献   

7.
A novel cetylpyridinium chloride-selective membrane sensor consisting of cetylpyridinium-ferric thiocyanate ion pairs dispersed in a PVC matrix placticized with dioctylphthalate is described. The electrode shows a stable, near-Nernstian response for 1 x 10(-3)-1 x 10(-6) mol l-1 cetylpyridinium chloride (CPC) at 25 degrees C over the pH range 1-6 with a cationic slope of 57.5 +/- 0.4. The lower detection limit is 8 x 10(-7) mol l-1 and the response time is 30-60 s. Selectivity coefficients for CPC relative to a number of interfering substances were investigated. There is negligible interference from many cations, anions and pharmaceutical excipients; however, cetyltrimethylammonim bromide (CTMAB) interfered significantly. The determination of 0.5-350 micrograms/ml of CPC in aqueous solutions shows an average recovery of 98.5% and a mean relative standard deviation of 1.6% at 56.0 micrograms/ml. The direct determination of CPC in Ezafluor mouthwash gave results that compare favorably with those obtained by the British Pharmacopoeia method. Precipitation titrations involving CPC as titrant are monitored with a CP sensor. The CP electrode has been utilized as an end point indicator electrode for the determination of anionic surfactants in some commercial detergents.  相似文献   

8.
A diclofenacselective electrode with a plasticized poly(vinyl chloride) membrane containing an ion associate of diclofenac with Astrafloxin FF as an electrode-active substance was developed. The linearity range of the electrode function varied from 5 × 10?5 to 5 × 10?2 M; the slope of the electrode function was 59.0 ± 1.2 mV/pc, and the working pH range was 9–12. The effectiveness of the use of this electrode for monitoring diclofenac in pharmaceutical preparations was demonstrated.  相似文献   

9.
Preparation, characterization, and applications of a 1,10-phenanthrolinium cation (phenH(+))-sensitive potentiometric sensor are described. The sensor incorporates a liquid polymeric membrane consisting of phenH-tetraphenylborate, nitrophenyloctyl ether, and poly(vinyl chloride) as ion exchanger, plasticizer, and polymeric support, respectively. The sensor exhibits a fast and Nernstian response to phenH(+) over the concentration range of 6 x 10(-6)-2 x 10(-4) M with a monovalent cationic slope of 58.0+/-0.5 mV/log[phenH(+)] in acetate buffer of pH 4.2. The sensor is successfully applied to the monitoring of the potentiometric titration of Hg(II) and Cu(II) ions with phen solution in the presence of citrate and acetate buffers of pH 4.2, respectively. Sharp inflection breaks (90-180 mV) at 1:1 (metal:phen reaction) are obtained in the presence of chloride and thiocyanate background. This stoichiometry is explained by the formation of insoluble [HgCl(2)(phen)], [Hg(SCN)(2)(phen)], and [Cu(SCN)(2)(phen)] complexes. Optimization of each titration and the effect of foreign ions are evaluated. The method offers the advantages of adequate sensitivity, accuracy, and selectivity for the determination of mercury and copper in pharmaceutical, rock, and tea samples. The results are in good agreement with those obtained using the standard atomic absorption spectrometric and United States Pharmacopeial methods.  相似文献   

10.
The construction and performance characteristics of a novel chromate ion-selective membrane sensor are described and used for determining chromium(III) and chromium(VI) ions. The sensor is based on the use of a rhodamine-B chromate ion-associate complex as an electroactive material in a poly(vinyl chloride) membrane plasticized with o-nitrophenyloctyl ether as a solvent mediator. In a phosphate buffer solution of pH 6 - 7, the sensor displays a stable, reproducible and linear potential response over the concentration range of 1 x 10(-1) - 5 x 10(-6) mol l(-1) with an anionic Nernstian slope of 30.8 +/- 0.5 mV decade(-1) and a detection limit of 1 x 10(-6) mol l(-1) Cr(VI). High selectivity for Cr(VI) is offered over many common anions (e.g., I-, Br-, Cl-, IO4-, CN-, acetate, oxalate, citrate, sulfate, phosphate, thiosulfate, selenite, nitrate) and cations (e.g., Ag+, Ca2+, Sr2+, Co2+, Ni2+, Cu2+, Mn2+, Fe2+, Zn2+, Cd2+, Al3+, Cr3+). The sensor is used for determining Cr(VI) and/or Cr(III) ions in separate or mixed solutions after the oxidation of Cr(III) into Cr(VI) with H2O2. As low as 0.2 microg ml(-1) of chromium is determined with a precision of +/-1.2%. The chromium contents of some wastewater samples were accurately assessed, and the results agreed fairly well with data obtained by atomic absorption spectrometry.  相似文献   

11.
Hassan SS  Marzouk SA  Sayour HE 《Talanta》2003,59(6):1237-1244
A novel polymeric membrane sensor sensitive to (4-sulphophenylazo-)1-naphthylamine (SPAN) based on the use of tris(bathophenanthroline) Ni(II)–SPAN ion pair as an ion exchanger in plasticised PVC membrane is described. The sensor exhibits a linear calibration plot with near-Nernstian anionic slope of −55.0±0.3 mV log[SPAN]−1 over the concentration range 10−6–10−2 mol l−1 at pH 7. The sensor shows working range over the pH 6–8, response time of 20 s for 10−5 mol l−1 and operational lifetime of 8 weeks. The sensor is used for quantification of micro quantities of nitrite ion by a prior conversion into the more lipophilic SPAN ion, which is measured with adequate sensitivity, and high selectivity using SPAN sensor. Validation of the method according to the quality assurance standards shows good performance characteristics. The sensor is satisfactory utilised for potentiometric determination of nitrite ion in wastewater samples and meat products. The results are favourably compared with data obtained using the standard spectrophotometric procedure involving the same reaction.  相似文献   

12.
A potentiometric device based on interfacing a solid electrolyte oxygen ion conductor with a thin platinum film acts as a robust, reproducible sensor for the detection of hydrocarbons in high- or ultrahigh-vacuum environments. Sensitivities in the order of approximately 5 x 10(-10) mbar are achievable under open circuit conditions, with good selectivity for discrimination between n-butane on one hand and toluene, n-octane, n-hexane, and 1-butene on the other hand. The sensor's sensitivity may be tuned by operating under constant current (closed circuit) conditions; injection of anodic current is also a very effective means of restoring a clean sensing surface at any desired point. XPS data and potentiometric measurements confirm the proposed mode of sensing action: the steady-state coverage of Oa, which sets the potential of the Pt sensing electrode, is determined by the partial pressure and dissociative sticking probability of the impinging hydrocarbon. The principles established here provide the basis for a viable, inherently flexible, and promising means for the sensitive and selective detection of hydrocarbons under demanding conditions.  相似文献   

13.
Mashhadizadeh MH  Shoaei IS  Monadi N 《Talanta》2004,64(4):1048-1052
A new PVC membrane potentiometric sensor that is highly selective to Fe(III) ions was prepared by using 2-[(2-hydroxy-1-propenyl-buta-1,3-dienylimino)-methyl]-4-p-tolylazo-phenol [HPDTP] as a suitable carrier. The electrode exhibits a linear response for iron(III) ions over a wide concentration range (3.5 × 10−6 to 4.0 × 10−2) with a super Nernstian slope of 28.5 (±0.5) per decade. The electrode can be used in the pH range from 4.5 to 6.5. The proposed sensor shows fairly a good discriminating ability towards Fe3+ ion in comparison to some hard and soft metals such as Fe2+, Cd2+, Cu2+, Al3+ and Ca2+. It has a response time of <15 s and can be used for at least 2 months without any measurable divergence in response characteristics. The electrode was used in the direct determination of Fe3+ in aqueous samples and as an indicator electrode in potentiometric titration of Fe(III) ions.  相似文献   

14.
A visual strip has been developed for sensing iron in different aqueous samples like natural water and fruit juices. The sensor has been synthesized by UV-radiation induced graft polymerization of acrylamide monomer in microporous poly(propylene) base. For physical immobilization of iron selective reagent, the in situ polymerization of acrylamide has been carried out in the presence of 1,10-phenanthroline. The loaded strip on interaction with Fe(II) in aqueous solution turned into orange red color and the intensity of the color was found to be directly proportional to the amount of Fe(II) in the aqueous sample. The minimal sensor response with naked eye was found for 50 ng mL−1 of Fe in 15 min of interaction. However, as low as 20 ng mL−1 Fe could be quantified using a spectrophotometer. The detection limit calculated using the 3s/S criteria, where ‘s’ is the standard deviation of the absorbance of blank reagent loaded strip and ‘S’ is the slope of the linear calibration plot, was 1.0 ng mL−1. The strip was applied to measure Fe in a variety of samples such as ground water and fruit juices.  相似文献   

15.
The construction of PVC matrix type tripelennamine ion selective electrodes and their use for direct potentiometry, potentiometric titration and flow injection analysis of tripelennamine cation are described. The membranes of these electrodes consist of tripelennamine-tetraphenylborate, reineckate and picrylsulfonate ion-association complexes dispersed in PVC matrix with tributyl phosphate (TBP) plasticizer. The electrodes exhibit near-Nernstian response over the concentration range of 10–1-10–4 M tripelennamine over the pH range 4.5–8.0. Selectivity coefficients data obtained for 17 different organic and inorganic ions are presented. The results obtained for the determination of 29 g/ml-29 mg/ml of tripelennamine with the proposed electrodes show average recoveries of 99.5–99.9% and mean standard deviations of 0.6–1.2%. The data agree well with those obtained by the standard methods.  相似文献   

16.
A new polymeric membrane electrode has been constructed for the determination of phenylpropanolamine hydrochloride. The electrode was prepared by solubilizing the phenylpropanolamine-phosphomolybdate ion associate into a polyvinyl chloride matrix plasticized by dibutylphthalate as a solvent mediator. The electrode showed near-Nernstian response over the concentration range of 1 × 10?5–1 × 10?2 M with low detection limit of 6.3 × 10?6 M. The electrode displays a good selectivity for phenylpropanolamine with respect to a number of common inorganic and organic species. The electrode was successfully applied to the potentiometric determination of phenylpropanolamine ion in its pure state and its pharmaceutical preparation in batch and flow injection conditions.  相似文献   

17.
Rao VP  Rao KV  Sarma PV 《Talanta》1969,16(2):277-280
Iron up to 3 ppm can be absorptiometrically determined by extracting the ferroin-thiocyanate complex at pH 1 into isobutyl methyl ketone (IBMK). At this pH thiocyanate itself reduces iron(III) so reductants such as hydroxylamine are not needed. The complex is very stable and has a molar absorptivity of 20.5 x 10(3) in IBMK at 525 nm. Most of the substances associated with iron in minerals and alloys do not interfere and methods are suggested for the elimination of the effect of those which do.  相似文献   

18.
Dimethyl-4,4-dimethoxy-5,6,5′,6′-dimethylene dioxy biphenyl-2,2-dicarboxylate (DDB) liver drug is used as a novel ionophore in plasticized poly (vinyl chloride) (PVC) matrix membrane sensors for barium ions. Optimum performance characteristics are displayed by membrane sensor incorporating DDB ionophore, potassium tetrakis(4-chlorophenyl)borate as lipophilic salt, and o-nitrophenyloctyl ether as plasticizer. The sensor exhibits a linear response over the concentration range 10−1-10−5 mol l−1 BaCl2 with a Nernstian slope of 30 mV per decade and high selectivity towards Ba2+ with respect to Li+, Na+, K+, Rb+, NH4+, Mg2+, Ca2+, Sr2+, Mn2+, Co2+, Ni2+, Cd2+, Al3+, La3+, and Ce3+ ions. The sensor response is stable over a wide pH range (4-9) and the lifetime is about 2 months. The proposed sensor is successfully applied to the determination of Ba2+contents of some rocks.  相似文献   

19.
A metal ion indicator, Alizarin Red S, was tested for its potential use in uranium selective optode membrane. The water-soluble indicator was lipophilized in the form of an ion pair with tetraoctylammonium bromide, and subsequently immobilized on a triacetyl cellulose membrane. The membrane responds to uranium ions, giving a color change from yellow to violet in acetate buffer pH 5. This optode has a linear range of (1.70-18.7) × 10−5 M of UO22+ ions with a limit of detection of 5 × 10−6 M. The response time of optode was within 6 min depending on the concentration of UO22+ ions. The sensor can readily be regenerated with hydrochloric acid solution (0.01 M). The optode is fully reversible.  相似文献   

20.
Hassan SS  Ali MM  Attawiya AM 《Talanta》2001,54(6):1153-1161
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1×10−1–2×10−5 mol l−1 UO22+ with a cationic slope of 25.0±0.2 mV decade−1. The working pH range is 2.8–3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N′,N′-bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1×10−1–5×10−5 mol l−1 UO22+ with near-Nernstian slope of 27.5±0.2 mV decade−1 are obtained. The working pH range is 2.5–3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 μg ml−1 uranium in aqueous solutions shows an average recovery of 97.2±1.3%. Application for the determination of uranium at levels of 0.01–1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence.  相似文献   