首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Toral MI  Richter P  Rodríguez C 《Talanta》1997,45(1):147-153
A highly sensitive and selective second derivative spectrophotometric method has been developed for the determination of copper and iron in mixtures. The method is based on the separation of the analytes by liquid-liquid extraction as picrate ion pairs. Iron-picrate, reacts in the organic phase of DCE with 5-phenyl-3-(4-phenyl-2-pyridinyl)-1,2,4-triazine (PPT). Similarly the copper-picrate reacts with 2,9-dimethyl-4,7-diphenyl-1,10-phenantroline (bathocuproine). The extracts were evaluated directly by derivative spectrophotometric measurement, using the zero-crossing approach for determination of copper and graphic method for iron. Iron and copper were thus determined in the ranges 8-120 ng ml(-1) and 8-125 ng ml(-1), respectively, in the presence of one another. The detection limits achieved (3sigma) were 2.9 ng ml(-1) of iron and 2.8 ng ml(-1) of copper. The relative standard deviations were in all instances less than 2.1%. The proposed method was applied to the determination of both analytes in river and tap water and the results were consistent with those provided by the AAS standard method.  相似文献   

2.
The reduction reaction of imidacloprid [1-(6-chloro-3-pyridylmethyl)-N-nitroimidazolidin-2-ylideneamine] at a mercury electrode shows two well-defined waves in the range of pH 2.0–11.0. The characteristics of the electrode processes were examined. The analyte captures four electrons in the first step and two in the second to give the hydroxylamine and amine derivatives, respectively. A differential-pulse polarographic method for the determination of imidacloprid based on the first reduction peak of this compound is presented. Britton-Robinson buffer was used as a supporting electrolyte and optimum pH value was found to be pH 8.O. The applicable concentration range was from 10 to 200 ng/ml, with a relative standard deviation of 1.5% (for a level of 80 ng/ml) and a detection limit of 3 ng/ml. The method has been satisfactorily applied to the determination of imidacloprid in commercial formulations.  相似文献   

3.
Yang J  Ge H  Jie N  Ren X  Zou H 《Talanta》1994,41(12):2055-2060
The study indicated that yttrium(III) could form an ion association compound with a new synthetic reagent, 1,6-bi(1′-phenyl-3′-methyl-5′-pyrazolone-4′-)hexanedione (BPMPHD) and cetyl trimethyl ammonium bromide (CTMAB). The compound could enhance the natural fluorescence of BPMPHD by about 260 times, upon which a new fluorescence method was developed for determining yttrium in rare earth (RE) samples. The determination range was 9–900 ng/ml. The detection limit was 1.8 ng/ml. The composition of the ion association was [Y(BPMHD)2]CTMAB+.  相似文献   

4.
Two flow injection inductively coupled plasma atomic emission spectrometric methods for the preconcentration and determination of trace amounts of cadmium in sea-water and waste-water samples are described based on the adsorption of the metal ion on a micro-column placed in the injection valve of the FI manifold and packed with silica gel funtionalised with 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH-gel) and silica gel functionalised with methylthiosalicylate (TS-gel), respectively. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES are evaluated. The DPTH-gel preconcentration method has a linear calibration range from 5 to at least 100 ng ml(-1) of cadmium, with a R.S.D. of 1.1% for ten independent analyses of 100 ng ml(-1), a detection limit of 1.1 ng ml(-1) and a throughput of 40 samples per hour using a 60 s preconcentration time. The TS-gel preconcentration method shows a linear range between 10 and 100 ng ml(-1), with a R.S.D. of 2.5% for ten independent analyses of 100 ng ml(-1), a detection limit of 4.3 ng ml(-1) and a sample throughput of 24 samples per hour for a preconcentration time of 120 s. Validation was carried out against a certified reference water sample and by determining the analyte content in spiked synthetic sea-water, sea-water and waste-water.  相似文献   

5.
Wu Y  Hu B  Peng T  Liao Z  Jiang Z 《Talanta》2001,55(4):841-845
Based on gaseous compound introduction as 1-phenyl-3-methyl-4-benzoylpyrazolone[5](PMBP) chelate of aluminum by electrothermal vaporization in ICP-AES, a method for determination of trace aluminum was developed. Trace aluminum was vaporized at temperature of 1000 degrees C, and the vaporization behavior of aluminum chelate was detailedly investigated. Under the optimum conditions, the detection limit of aluminum was 0.6 ng ml(-1), and the relative standard deviation for 0.1 mug ml(-1) aluminum was 4.7% (n=8). The proposed method was applied to the determination of trace aluminum in rice flour reference materials, and the results well agreed with the reference values.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) method for the determination of a new H2 receptor antagonist, 3-amino-5-[3-[4-(piperidinoindanyloxy)]propylamino] -1-methyl-1H-1,2,4-triazole (I), in human plasma and urine was developed. The method employs liquid-liquid extraction of the analyte and an internal standard and chromatographic separation using an alkylphenyl-bonded HPLC column. The total time of chromatography was less than 10 min. Sensitivity was 10 ng/ml for the plasma analysis and 1 microgram/ml for the analysis of I from urine. The coefficients of variation, based on interpolated concentrations, were less than 10%. The method was used for more than 5000 samples during clinical pharmacokinetic studies.  相似文献   

7.
Singh HB  Agnihotri NK  Singh VK 《Talanta》1999,48(3):623-631
A sensitive derivative spectrophotometric method using 1-nitroso-2-naphthol has been developed for determination of trace amounts of cobalt in the presence of a neutral surfactant. Photometric parameters, viz., lambda(max), molar absorption coefficient and analytical sensitivity of the complex formed in micellar media are 420 nm, 3.18x10(4) l mol(-1) cm(-1) and 2.05 ng ml(-1), respectively. Beer's law holds from 0.20 to 3.0 mug ml(-1) of the analyte concentration. The method has a high sensitivity with a detection limit of 1.68 ng ml(-1). A selective determination of cobalt in presence of copper(II) or iron(III) using derivative spectral profiles and without any masking or pre-separation is also reported. Samples of drugs and standard alloys analysed by the proposed method yielded results comparable to those obtained using recommended procedures.  相似文献   

8.
A method for the selective determination of trimethylamine (TMA) in aqueous matrices by liquid chromatography is reported. The proposed procedure is based on the derivatization of the analyte with 9-fluorenylmethyl chloroformate (FMOC) in a precolumn (Hypersil C18, 30 microm, 20 mm x 2.1 mm i.d.) connected on-line to the analytical column (LiChrosphere 100 RP18, 5 microm, 125 mm x 4 mm i.d.). Gradient elution was performed with a mixture of acetonitrile-water-0.05 M borate buffer (pH 9.0). The method has been applied to the direct determination of TMA in water within the 0.25-10.0 microg/ml concentration interval, and can also be adapted to the determination of TMA over the range 0.05-1.0 microg/ml by incorporating a preconcentration stage with C18 solid-phase extraction (SPE) cartridges. Good linearity, reproducibility and accuracy was achieved within the tested concentration intervals. The limits of detection at 262 nm were 50 and 5 ng/ml for the direct method and for the method involving preconcentration, respectively. The proposed conditions allowed the selective determination of TMA in the presence of other primary and secondary short-chain aliphatic amines. The utility of the described procedure has been tested by determining TMA in different water samples.  相似文献   

9.
A liquid chromatographic/turbo ionspray tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of L-753,037, a potent endothelin receptor antagonist currently under development for the treatment of cardiovascular diseases, in human plasma. L-753,037 is extracted from 0.5 ml of human plasma using liquid-liquid extraction and analyzed by LC/MS/MS with a turbo ionspray interface. Method validation results showed that this method is very sensitive, reliable, selective and reproducible. L-753,048, an ethoxy analogue of L-753,037, was used as the internal standard. The method has a lower limit of quantitation (LOQ) of 50 pg ml(-1) with a linear calibration range of 0.05-50 ng ml(-1). The intra-day precision and accuracy (n = 5) were measured to be below 10% relative standard deviation (RSD) and between 97.4 and 102.8% of the nominal values, respectively, for all calibration standard concentrations within the calibration curve range. The inter-day precision and accuracy (n = 3 days, 5 replicates per day) were measured to be below 6.5% RSD and between 99.3 and 102.0% of the nominal values, respectively, for all quality control concentrations. The extraction recovery was determined to be approximately 99% on average. The analyte was found to be stable in plasma through three freeze-thaw cycles, for at least 4 h at ambient temperature and for up to 40 days under -20 degrees C freezer storage conditions. The analyte was also shown to be stable for at least 24 h in the reconstitution solution at room temperature and for up to 3 days as a dried extract at 4 degrees C. Additional variations in plasma concentration of the analyte due to the use of different sources of plasma were also evaluated.  相似文献   

10.
A new method for the determination of the hydroxymetabolites of vitamin D(3) (24,25-(OH)(2)-D(3), 1,25-(OH)(2)-D(3) and 25-OH-D(3)) in plasma is reported. The method is based on the integration of three subsystems: continuous cleanup/preconcentration, HPL separation and post-column fluorimetric derivatisation. The derivatising subsystem is based on the dehydration reaction undergone by the secosteriod molecules in a strong-acid medium. The calibration graphs were run between 0.1 pg ml(-1) and 100 ng ml(-1) for each analyte with excellent regression coefficients (>/=0.9933) in all cases. The precision at two concentration levels was established with acceptable RSDs (%) in all instances (values between 2.1 and 5.2%). The method was also checked by applying it to human plasma samples spiked with the target analytes and the recoveries ranged between 86 and 106%.  相似文献   

11.
A highly sensitive and selective high-performance liquid chromatographic method with short-wavelength UV detection is described for the determination of ionic compounds in biological fluids, which was applied to two basic compounds, 2-(3-[4-(4-fluorophenyl)-1-piperazinyl]propyl)-6,7,8,9-tetrahydro-2H-nap htho [2,3-b][1,4]oxazin-3(4H)-one (I) and methyl 2-(4-diphenylmethyl-1-piperazinyl)ethyl (+/-)-1,4-dihydro-2,6-dimethyl-4-(m-nitrophenyl)-3,5-pyridinedicarboxyla te (II), in human serum. The method is based on the combination of the column-switching technique and ion-pair chromatography. In the first ODS column, the analyte is pre-separated from endogenous substances in serum by ion-pair chromatography. After column switching, in the second ODS column the heart-cut fraction containing the analyte is further separated by non-ion-pair chromatography from coeluted endogenous substances from the first ODS column. The proposed method offered high sensitivity and selectivity with UV detection at 215 nm for I and 230 nm for II. The detection limits were 0.2 ng/ml for both I and II using 1 ml of serum. The principle of the proposed method would be applicable to both acidic and basic compounds in biological fluids with a suitable ion-pair reagent.  相似文献   

12.
A method using an on-line solid phase extraction (SPE) and liquid chromatography with electrospray-tandem mass spectrometry (LC-ES-MS/MS) for the determination of flunitrazepam (FM2) and 7-aminoflunitrazepam (7-aminoFM2) in urine was developed. A mixed mode Oasis HLB SPE cartridge column was utilized for on-line extraction. A reversed phase C18 LC column was employed for LC separation and MS/MS was used for detection. Sample extraction, clean-up and elution were performed automatically and controlled by a six-port valve. Recoveries ranging from 94.8 to 101.3% were measured. For both 7-aminoFM2 and FM2, dual linear ranges were determined from 20 to 200 and 200-2000 ng/ml, respectively. The detection limit for each analyte based on a signal-to-noise ratio of 3 ranged from 1 to 3 ng/ml. The intra-day and inter-day precision showed coefficients of variance (CV) ranging from 4.6 to 8.5 and 2.6-9.2%, respectively. The applicability of this newly developed method was examined by analyzing several urine samples.  相似文献   

13.
Cloud point extraction (CPE) was applied as a preconcentration step prior to graphite furnace atomic absorption spectrometry (GFAAS) determination of manganese(II) and iron(III) in water samples. After complexation with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), the analytes could be quantitatively extracted to the phase rich in the surfactant p-octylpolyethyleneglycolphenylether (Triton X-100) and be concentrated, then determined by GFAAS. The parameters affecting the extraction efficiency, such as solution pH, concentration of PMBP and Triton X-100, equilibration temperature and time, were investigated in detail. Under the optimum conditions, preconcentration of 10 ml of sample solution permitted the detection of 0.02 ng ml(-1) of Mn(II) and 0.08 ng ml(-1) of Fe(III) with enrichment factors of 31 and 25 for Mn(II) and Fe(III), respectively. The proposed method was applied to determination of trace manganese(II) and iron(III) in water samples with satisfactory results.  相似文献   

14.
Yao W  Byrne RH 《Talanta》1999,50(2):277-282
A flow-through solid phase spectrophotometric (SPS) sensing device is proposed for the determination of minoxidil. The analyte is concentrated on Sephadex SP-C25 ion-exchanger packed in a flow cell and it is monitored by UV-Vis spectrophotometry at 282 nm, without derivatization reaction. When a HCl (10(-2) mol l(-1))/NaCl (5x10 (-2) mol l (-1)) solution is used as carrier/desorbing solution, the sensor responds linearly in the measuring range of 0.2-7, 0.1-4 and 0.05-2 mug ml(-1) with detection limits of 60, 33 and 6 ng ml(-1) for 600, 1000 and 2000 mul of sample, respectively. The relative standard deviations (%) for these volumes are 0.38, 1.06 and 2.63, respectively. The method was satisfactorily applied to the determination of minoxidil in pharmaceutical preparations and the results were compared with those obtained by high performance liquid chromatography (HPLC).  相似文献   

15.
A sensitive method for the simultaneous determination of loratadine and its major active metabolite descarboethoxyloratadine (DCL) in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted from plasma with toluene followed by back-extraction into formic acid (2%) for DCL after which the toluene containing the loratadine was evaporated, the analyte reconstituted and combined with the DCL back-extract. Chromatography was performed on a Phenomenex Luna C18 (2) 5-microm, 150x2.1-mm column with a mobile phase consisting of acetonitrile-0.1% formic acid using gradient elution (10 to 90% acetonitrile in 2 min) at a flow-rate of 0.3 ml/min. Detection was achieved by a Perkin-Elmer API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode. TurbolonSpray ionisation was used for ion production. The mean recovery for loratadine and descarboethoxyloratadine was 61 and 100%, respectively, with a lower limit of quantification at 0.10 ng/ml for both the analyte and its metabolite. This is the first assay method described for the simultaneous determination of loratadine and descarboethoxyloratadine in plasma using one chromatographic run. The method is sensitive and reproducible enough to be used in pharmacokinetic studies.  相似文献   

16.
Lin S  Zheng C  Yun G 《Talanta》1995,42(7):921-926
The versatility of flow injection as a procedure for enhancing the performance of atomic spectrometry is demonstrated by the on-line separation and preconcentration of analyte ions of interest for methods employing atomic spectrometric measurements. In this paper, a sensitive method for the determination of palladium by flame atomic absorption spectrometry associated on-line with the flow injection technique has been developed. A flow system comprising a micro-column packed with activated carbon fibre was used for the concentration of palladium. In order to further enhance the performance of the analysis a new manifold with an additional column has been designed to increase the sensitivity by doubling the analytical signals. The method is sensitive and easily operating with a sampling rate of 15-20/h. The detection limit of this method is 0.3 ng/ml in standard solution and the precision is 3.9% relative standard deviation at 50 ng/ml. Recoveries of palladium in spiked solutions are 103-107%.  相似文献   

17.
A method is described for the extraction of a phosphonic acid angiotensin-converting enzyme inhibitor from either urine or plasma, and subsequent quantitation using high-performance liquid chromatographic (HPLC) analysis and post-column o-phthalaldehyde reagent derivatization. The compound cannot be quantitatively extracted from the body fluids, but use of a fluorinated internal standard allowed for the computation of accurate results. With the use of an internal standard, excellent precision, linearity, and recovery were obtained for analyte response in both urine and plasma. In urine a working range of 0.2-10 micrograms/ml was found, with a limit of detection of 0.1 micrograms/ml. For plasma the working range was found to be 2-500 ng/ml, and the limit of detection was established as 1 ng/ml. Due to the non-polar character of the analyte at low pH values, it was possible to use novel extraction (solid-phase C8 column) and HPLC [poly(styrenedivinyl benzene) HPLC column] conditions to separate and quantitate the compound from plasma and urine.  相似文献   

18.
The luminescence of the lasalocid-terbium(III) system in the presence of Triton X-100 and trioctylphosphine oxide has been studied by obtaining kinetic and equilibrium measurements and using the stopped-flow mixing technique. The initial rate and luminescence signal of this system are directly proportional to the lasalocid concentration, which allows one to develop very simple, fast, automatic methods for the determination of this analyte. Kinetic and equilibrium data can be obtained in only 0.1 and 10 s, respectively. The calibration graphs were linear over the range 0.004-5.0 mug ml(-1) (kinetic method) and 0.01-5.0 mug ml(-1) (equilibrium method) and the detection limits achieved were 1 and 3 ng ml(-1), respectively, equivalent to 2 and 6 ng g(-1) lasalocid in a chicken liver sample, which are similar to those afforded by the chromatographic methods described for this determination. The relative standard deviation of both methods was close to 2%. The analytical recoveries obtained by applying the kinetic and equilibrium methods to drinking water, poultry feed and chicken liver samples ranged from 95.6 to 102.1% and from 95.9 to 104.9%, respectively.  相似文献   

19.
A manual-injection liquid chromatographic method using fluorescence detection permitted determination of a new antiasthmatic drug, azelastine, and its desmethyl metabolite extracted from human plasma. Reliable quantitation was achieved to at least 0.3 ng/ml for each analyte. No interference was seen in co-chromatography of sixteen other substances, which were potential co-medications (or their metabolites) as used in standard asthma or allergy treatment.  相似文献   

20.
A simple, sensitive, and specific analytical method has been developed for the quantitative determination of 15 reducing carbohydrates in the soil solution of crop rhizosphere. Reducing carbohydrates were derivatized with 1-phenyl-3-methyl-5-pyrazolone, separated by reversed-phase high-performance liquid chromatography and detected by electrospray ionization tandem mass spectrometry. Lower limits of quantitation of 2 ng/mL were achieved for all carbohydrates. Quantitation was performed using peak area ratios (analyte/internal standard) and a calibration curve spiked in water with glucose-d2 as the internal standard. Calibration curves showed excellent linearity over the range 2–100 ng/mL (10–1,000 ng/mL for glucose). The method has been tested with quality control samples spiked in water and soil solution samples obtained from the rhizosphere of wheat and canola and has been found to provide accurate and precise results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号