首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
磷脂的分离纯化及高效毛细管电泳分析   总被引:5,自引:0,他引:5  
肖玉秀  梅洁  何秀峰  程伟 《色谱》2006,24(1):30-34
采用溶剂提取和柱色谱法分离纯化市售大豆粉末磷脂(卵磷脂含量14.05%),得到高纯度的卵磷脂产品(纯度92.80%)。重点建立了磷脂的胶束电动毛细管色谱(MECC)分离分析方法。以分离度和峰面积为优化指标,对表面活性剂及其浓度、电泳缓冲液pH、有机改性剂及其含量、缓冲液浓度、温度等条件进行优化,确定了最优化电泳条件:电泳缓冲液为35 mmol/L脱氧胆酸钠-1 mmol/L 硼砂缓冲液/正丙醇(体积比为57∶43)(pH 8.30),柱温44 ℃,操作电压25 kV,检测波长200 nm;内加法定性磷脂组分;外标法定量卵磷脂。结果表明,MECC法能有效分离5种磷脂组分;0.1~1 g/L的质量浓度范围内卵磷脂的线性关系良好(r=0.9990),平均回收率为98.0%,日内、日间精密度分别为1.36%和3.27%,定性结果与薄层色谱法、红外光谱法的定性结果相符。  相似文献   

2.
The systematic optimization of capillary electrophoretic separations using a dynamic scouting optimum method-controlled weighted centroid variable size simplex algorithm is described. The factors affecting the efficiency of the separation are simultaneously considered during the optimization procedures. The established optimization method is applied to amino acid separation by capillary zone electrophoresis (CZE) with on-column indirect UV detection and to the separation of local anesthetics by micellar electrokinetic chromatography (MECC) with on-column UV detection. The optimization procedures include the pH and the background absorption electrolyte (BGAE) concentrations together with the applied voltage in the CZE separation of amino acids. The pH, the SDS concentrations together with the percentage of methanol are considered in the MECC separation of local anesthetics. Two methods, i.e., the Long Coefficient and Uniform Design Table, are used to define the start vertexes during the optimization procedure and similar final experimental conditions for the separations are achieved. Thirteen native amino acids are baseline separated by CZE and 4 local anesthetics are satisfactorily separated by MECC.  相似文献   

3.
液相色谱-串联质谱法测定动物肝脏中黄曲霉毒素   总被引:2,自引:0,他引:2  
建立了动物肝脏中黄曲霉毒素G2、G1、B2、B1的高效液相色谱-串联质谱检测方法。样品经体积比为84∶16的乙腈-水溶液提取,离心后通过真菌毒素多功能净化柱,净化液氮气吹干,用流动相定容,采用C18柱分离,10mmol/L的甲酸铵溶液和甲醇作为流动相,以50∶50比例等度洗脱,在多重反应监测(MRM)正离子模式下进行分析。各组分在9min内完全分离,方法线性关系良好,黄曲霉毒素G2、G1、B2、B1的检出限分别为0.030、0.026、0.016、0.027μg/kg,三个加标水平下平均回收率在81%~98%之间,相对标准偏差小于2%。该方法简便快速,准确可靠,可用于动物肝脏中黄曲霉毒素的测定。  相似文献   

4.
Williams  R. C.  Edwards  J. F.  Ainsworth  C. R. 《Chromatographia》1994,38(7-8):441-446
Summary Micellar electrokinetic capillary chromatography (MECC) has been applied to the separation and analysis of diastereoisomer impurities in chiral pharmaceutical compounds. Differences in separation mechanism and selectivity make MECC useful as an alternative method to HPLC for analysis of these synthetic inpurities. Advantages of MECC include high efficiency separations and low consumption of sample and solvents. Water soluble and insoluble pharmaceutical compounds are used to illustrate the separation characteristics and quantitative capabilities of this versatile new analytical technique.  相似文献   

5.
李关宾  范春生  邢存章 《色谱》1997,15(1):65-66
以自制毛细管电泳-电化学检测系统对VC,VB1和VB6的毛细管区带电泳和胶束电动色谱的分离与检测情况进行了初探。结果表明,在0.01mol/LNH3-NH4Cl介质中,检测电势定于510~540mV(对SCE)时,三种维生素均有较好的CZE图,对VC的分离效率达468800块理论板。使用十二烷基硫酸钠时,分离效果欠佳。  相似文献   

6.
Micellar electrokinetic chromatography of proteins   总被引:1,自引:0,他引:1  
Micellar electrokinetic capillary chromatography (MECC) of proteins is a high resolution capillary electrophoretic (CE) analysis method that utilizes the hydrophobic and electrostatic interaction of protein analytes with surfactant micelles present in the buffer medium to facilitate separation. Through the manipulation of the protein-micelle interaction by the adjustment of variables such as surfactant concentration, solution pH, ionic strength, the presence of an organic modifier and the use of coated capillaries, MECC analyses of a wide variety of proteins have been optimized. MECC has been demonstrated to provide resolution of mixtures consisting of proteins with minor structural variations and also has provided the successful quantitative analysis of protein present in complex matrices. The adoption of protein MECC as a routine analytical technique may be dependent upon the successful interface of MECC with detection methodology, such as mass spectrometry, which can provide analyte characterization information.  相似文献   

7.
韩凤梅  程智勇  蔡敏  陈勇 《色谱》2000,18(5):456-458
 以甲氧苄氨嘧啶为内标,采用胶束电动毛细管色谱法分离测定了新药消糖灵中的优降糖。电泳条件:以25 mmol/L硼砂-30 mmol/L十二烷基硫酸钠(pH 9.0)为电泳介质,未涂层石英毛细管(50 μm i.d.×39.5 cm,有效分离长度34.8 cm)为分离通道,压力进样(68.95 kPa.s),17 kV恒压电泳(28 ℃),检测波长228 nm。优降糖在14 min内与其他成分得到很好分离,且质量浓度为25 mg/L~275 mg/L时,优降糖可进行定量分析,加标回收率为(100.6±1.4)%。方法简便、快速,结果准确,重现性好,可用于优降糖复方制剂的质量控制。  相似文献   

8.
The systematic optimization of capillary electrophoretic separations using a dynamic scouting optimum method-controlled weighted centroid variable size simplex algorithm is described. The factors affecting the efficiency of the separation are simultaneously considered during the optimization procedures. The established optimization method is applied to amino acid separation by capillary zone electrophoresis (CZE) with on-column indirect UV detection and to the separation of local anesthetics by micellar electrokinetic chromatography (MECC) with on-column UV detection. The optimization procedures include the pH and the background absorption electrolyte (BGAE) concentrations together with the applied voltage in the CZE separation of amino acids. The pH, the SDS concentrations together with the percentage of methanol are considered in the MECC separation of local anesthetics. Two methods, i.e., the Long Coefficient and Uniform Design Table, are used to define the start vertexes during the optimization procedure and similar final experimental conditions for the separations are achieved. Thirteen native amino acids are baseline separated by CZE and 4 local anesthetics are satisfactorily separated by MECC. Received: 10 November 1997 / Revised: 19 January 1998 / Accepted: 24 January 1998  相似文献   

9.
部分水溶性维生素胶束电动毛细管色谱行为研究   总被引:3,自引:0,他引:3  
李小戈  何金兰 《色谱》1997,15(2):156-158
详细探讨了十二烷基硫酸钠浓度、硼砂浓度、溶液PH值、电泳电压对部分水溶性维生素胶束电动毛细管色谱行为的影响,在优化条件下,4min内完成5种水溶性维生素的分离。  相似文献   

10.
Another method has been developed for the separation of amino acids (1 min derivatization plus 22 min separation) by micellar electrokinetic capillary chromatography (MECC) with laser-induced fluorescence detection. Interestingly enough, such work has never been performed on essential amino acids derivatized by 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). Fifteen L-amino acid standards were labelled with NBD-F at 60 degrees C for 1 min, and separated in a buffer system containing 20 mM borate, 25 mM sodium cholate, 10 mM Brij 35 and 2.5% methanol. Methanol was employed to expand the MECC migration time window; whereas Brij 35 was used to improve the fluorescence intensity of amino acid derivatives. This method also indicates that bile salt is effective for MECC separation of ionic analytes. Surprising though, improvements in resolution, sensitivity and speed for amino acids analysis are obtained in this work, which are not initially apparent in just employing another derivatizing reagent. Under optimal conditions, 15 amino acids were separated in a short 22 min analysis time, the shortest ever reported, and detection limits of nanomolar concentration and attomole mass were obtained. Furthermore, RSDs of migration time and peak height are better than 1% and 1.8%, respectively, again the smallest ever reported in the literature.  相似文献   

11.
DNA adducts are thought to be crucial to the initiation of mutational and carcinogenic processes. Polycyclic aromatic hydrocarbons (PAHs) have been identified as one major source of carcinogenic risk since they can bind to DNA thus forming an adduct. Quantification of this adduct is important because it may correlate to the risk for cancer development. In this study, the adduct formed between 2'-deoxyguanosine 5'-monophosphate and benzo[ a]pyrene-7,8-dihydrodiol-9,10-epoxide (BPDE) was analyzed by capillary electrophoresis. Both capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MECC) modes with laser-induced fluorescence detection were used for the separation and analysis of DNA adducts. The exploration of capillary electrophoresis in several modes provided different separation mechanisms in which the stereochemical forms of the adduct could be separated. The best result obtained was using a coated fused-silica capillary in Tris-TAPS buffer, which provided high sensitivity with a detection limit of 2.5x10(-9) mol L(-1). MECC separation of the BPDE adduct, although less sensitive, provided an efficient enantioselective separation option.  相似文献   

12.
Capillary electrophoresis (CE) techniques have been successfully applied to the separation of metallothionein (MT) isoforms and have proved to be rapid, practical and economical. Study of a variety of different electrolytes and capillaries has shown that electrolyte buffer composition and capillary wall surface modifications can have considerable influence on isoform separation and resolution. Ionic surfactants such as sodium dodecyl sulphate (SDS) form micelles at elevated concentrations and the partitioning of molecules between the hydrophobic micelle phase and the aqueous phase and their resulting migration in an electric field is the basis of the technique known as micellar electrokinetic capillary chromatography (MECC). In the present work, we have used sheep and rabbit MT to optimise MECC conditions for analysis of MT isoforms. Capillaries of 57 cm gave much better separations than shorter columns although analysis times were increased to about 12 min. Changing the buffer and SDS concentration or the pH affected the selectivity of isoform separation and up to 5 isoforms in sheep MT and 6 in rabbit MT were completely or partially resolved. Comparing different diameter capillaries we conclude that 25 μm I.D. columns give better separations than 50 or 75 μm I.D. columns although sensitivity is reduced by a factor of about 3 and 5, respectively. Using our MECC conditions, columns coated with C1 or C18 hydrophobic material were not found to be useful in improving MT separation or resolution although further evaluation of these columns is in progress. Analysis of sheep liver extracts using optimised conditions showed the expression of at least 4 MT isoforms in response to Zn injection and 3 of these forms were evident in extracts from untreated sheep. We therefore conclude that MECC is a suitable method for MT isoform analysis.  相似文献   

13.
Although aflatoxins contamination in feedstuff is a well‐known problem, and hence these residues are controlled in poultry products, there is scarce information regarding the presence of these toxic substances in aquaculture fish, facilities that use several feedstuff for fish breeding. A simple, rapid, and sensitive method has been therefore developed for aflatoxins (B1, B2, G1, and G2) assessment in aquaculture products by combining ultrasound probe‐assisted extraction and vortex‐assisted liquid–liquid microextraction as a sample pretreatment, and high‐performance liquid chromatography‐tandem mass spectrometry as a separation/detection system. Aflatoxins were extracted from fish flesh/liver with a 60:40 acetonitrile/aqueous phosphate buffer (pH 7.0) mixture before preconcentration and clean‐up by vortex‐assisted liquid–liquid microextraction under the following optimized conditions: 5.0 mL of fish extract at pH 7.0 and NaCl at 0.5% (w/v), 400 μL of chloroform as extracting solvent, and vortex shaking at 2000 rpm for 1 min. The proposed method is shown to be precise and accurate, and the limit of quantitations (from 0.20 to 1.10 μg kg?1) were lower than the value established by the European Commission Regulation for aflatoxins in foodstuff. Results have shown that fish flesh is free of aflatoxins, but aflatoxins B2 and G1 were quantified in fish liver.  相似文献   

14.
苯胺及其衍生物的毛细管电泳行为研究   总被引:3,自引:1,他引:3  
采用紫外吸收检测,毛细管电泳分离,研究了九种苯胺及其衍生物在毛细管区带电泳(CZE)体系和胶束电动毛细管色谱(MECC)体系中的行为特征。讨论了缓冲溶液的浓度与pH、胶束浓度及混合胶束等在不同体系中对分离组分的影响,发现在CZE体系中,控制分离的主要因素是pKb值;在MECC体系中,控制分离的主要因素是溶质分子中碳原子数。建立了一种分离测定九种苯胺及其衍生物的高效毛细管电泳方法。  相似文献   

15.
A capillary zone electrophoresis (CZE) method was developed for the rapid analysis of charge heterogeneity of immunoglobulin G (IgG) monoclonal antibodies (mAbs). The separation was carried out in a short, dynamically coated fused-silica capillary. A number of separation parameters were investigated and optimized, including pH, concentration of the separation buffer (ε-amino caproic acid), concentration of the triethylenetetramine (TETA) dynamic coating, the capillary internal diameter and the field strength used for the separation. The effects of between-run flushing of the capillary and the data acquisition rate were also evaluated. Under the optimized conditions, a fast (<5 min), selective and reproducible separation of mAb charge variants was achieved under a very high electric field strength (1000 V/cm). This method also requires only a short conditioning of the capillary, with between-run conditioning completed within 2 min. The method was evaluated for specificity, sensitivity, linearity, accuracy and precision. The same separation conditions were applied to the rapid separation (2-5 min) of charge variants of multiple monoclonal antibodies with pI in the range of 7.0-9.5. Compared with other existing methods for charge variants analysis, this method has several advantages including a short run time, rapid capillary conditioning and simple sample preparation.  相似文献   

16.
寡糖的毛细管电泳分析   总被引:10,自引:0,他引:10  
常理文  腰锐锋 《分析化学》1994,22(10):975-979
多种寡糖经α-萘胺衍生化后,用硼砂作为电泳介质,实现了高效毛细管电泳分离。比较了毛细管区带电泳和胶束毛细管电动色谱分离寡糖α-萘胺衍生物的电泳行为,对影响分离度的诸因素进行了考察,选择了最佳分离条件。  相似文献   

17.
A micellar electrokinetic capillary chromatography (MECC) method has been developed for the determination of the four isoflavones, i.e. biochanin A, formononetin, genstein and daidzein in red clover (Trifolium Pratense L.). The effect of running buffer pH and concentration were investigated. An electrolyte composed of 30 mm borate, 20 mm sodium dodecyl sulfate (SDS) and 4 mg/mL HP-beta-CD containing 5% (v/v) ethanol at pH 10.1 provides a satisfactory separation for all the analytes. The applied voltage was 25 kV, and the capillary temperature was kept constant at 25 degrees C with a UV detection at 254 nm. The relative standard deviations (RSD) of the migration time and peak area were less than 1.73 and 3.94% (intra-day), and 2.29 and 4.38% (inter-day), respectively, under the optimized separation conditions. Regression equations revealed a good linear relationship between the peak area of each compound and its concentration. The contents of the four compounds in red clover were successfully determined with satisfactory repeatability and recovery.  相似文献   

18.
Zhou XM  Liu JW  Zhang ME  Chen SJ 《Talanta》1998,46(4):757-760
The micellar electrokinetic capillary chromatography (MECC) method is reported for the separation of heparin, and for the possibility of direct determination of free heparin in plasma. The conditions for MECC were: pH 8.5, 25 mM sodium dodecyl sulfate (SDS), 25 mM borate buffer, with a 30 cmx50 mum ID fused-silica capillary. The sample was detected with a UV-detector at 270 nm with heparin as external standard. The recovery rate was 95.6-98.7%. This method was linear in the range 80-7000 U l(-1). The within-run and between-run relative standard deviations were lower than 3.1 and 4.5%, respectively. It is suggested that this MECC method may be used to determine blood samples containing high levels of heparin.  相似文献   

19.
The application of dispersive liquid-liquid microextraction (DLLME) technique for the rapid analysis of aflatoxins B(1), B(2), G(1) and G(2) in maize, rice and wheat products has been evaluated. After extraction of aflatoxins from cereal matrices with a mixture of methanol/water 8:2 (v/v), the analytes were rapidly transferred from the extract to another small volume of organic solvent, chloroform, by DLLME. Aflatoxins were determined using high performance liquid chromatography with florescence detection and photochemical post-column derivatization. Parameters affecting both extraction and DLLME procedures, such as extraction solvent, type and volume of DLLME extractant, volume of water and salt effect, were systematically investigated and optimized to achieve the best extraction efficiency. Under the optimal experimental conditions, the whole analytical method provides enrichment factors around 2.5 times and detection limits (0.01-0.17 μg kg(-1)) below the maximum levels imposed by current regulation for aflatoxins in cereals and cereal products intended for direct human consumption. Recoveries (67-92%) and repeatability (RSD<10, n=3), tested in three different cereal matrices, meet the performance criteria required by EC Regulation No. 401/2006 for the determination of the levels of mycotoxins in foodstuffs. The proposed method was successfully applied to the analysis of retail cereal products with quantitative results comparable to the immunoaffinity chromatography (IAC). The main advantages of developed method are the simplicity of operation, the rapidity to achieve a very high sample throughput and low cost.  相似文献   

20.
A simple and sensitive automated method for determination of aflatoxins (B1, B2, G1, and G2) in nuts, cereals, dried fruits, and spices was developed consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–mass spectrometry (LC–MS). Aflatoxins were separated within 8 min by high-performance liquid chromatography using a Zorbax Eclipse XDB-C8 column with methanol/acetonitrile (60/40, v/v): 5 mM ammonium formate (45:55) as the mobile phase. Electrospray ionization conditions in the positive ion mode were optimized for MS detection of aflatoxins. The pseudo-molecular ions [M+H]+ were used to detect aflatoxins in selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample using a Supel-Q PLOT capillary column as an extraction device. The extracted aflatoxins were readily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC–MS with SIM method, good linearity of the calibration curve (r > 0.9994) was obtained in the concentration range of 0.05–2.0 ng/mL using aflatoxin M1 as an internal standard, and the detection limits (S/N = 3) of aflatoxins were 2.1–2.8 pg/mL. The in-tube SPME method showed >23-fold higher sensitivity than the direct injection method (10 μL injection volume). The within-day and between-day precision (relative standard deviations) at the concentration of 1 ng/mL aflatoxin mixture were below 3.3% and 7.7% (n = 5), respectively. This method was applied successfully to analysis of food samples without interference peaks. The recoveries of aflatoxins spiked into nuts and cereals were >80%, and the relative standard deviations were <11.2%. Aflatoxins were detected at <10 ng/g in several commercial food samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号