首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Park CI  Cha KW 《Talanta》2000,51(4):769-774
A rapid and sensitive method for the trace level determination of aluminium based on the formation of a 1:1 complex with chromotropic acid (1,8-dihydroxynaphthlene-3,6-disulfonic acid) in an methanol medium is reported. The fluorescence intensity of the system was 50 times greater than that of the system without aluminium. This method is very sensitive and selective for the direct determination of aluminium ion. The fluorescence is excited at 346 nm and measured at 370 nm. The optimum conditions are a chromotropic acid concentration of 5.0 ml (1.0x10(-4) M) and pH 4.0+/-0.5 (acetic acid-sodium acetate buffer). The fluorescence intensity is a linear function of the concentration of Al(III) in the range 2-100 ng ml(-1) and the detection limit is 1.0 ng ml(-1). The method has been applied successfully to the determination of trace amount of Al(III) in tap, river and sea-water samples.  相似文献   

2.
A spectrophotometric method is described for the determination of nitrate in the 0.5 to 50μg range using chromotropic acid as the reagent and masking agents for the elimination of possible critical interferences due to chloride, chlorine, iron(III) and oxidants. The method can be applied directly for the determination of 0.2–20 mg of nitrate/l in 2.5-ml samples of water. Over 4000 mg of chloride/l can be tolerated. The method is simple, rapid and reliable. At the 1 mg/l level for nitrate the coefficient of variation at the 95% confidence limit is 4% There are no interferences.  相似文献   

3.
A new cloud point extraction (CPE) method for ergotamine analysis using fluorimetric detection is described. Ergotamine from an aqueous solution was preconcentrated into a smaller surfactant-rich phase using nonionic surfactant polyoxyethylene(7.5)nonylphenylether (PONPE 7.5). Differently from the conventional CPE procedure in which the resulting surfactant-rich phase is diluted by a fluidificant before its analysis, in this method the fluorescence measurements were carried out directly onto the undiluted surfactant-rich phase. The high viscosity provided by the undiluted surfactant rich phase greatly improved the fluorescence emission of ergotamine, leading to a total enhancement factor of 1325. This spectral advantage plus the preconcentration factor achieved, contributed to the method sensitivity allowing the ergotamine determination at trace level concentration. Under optimal experimental conditions, a linear calibration curve was obtained from 3.81 × 10−7 to 1.10 μg mL−1, with detection and quantification limits of 0.11 and 0.38 pg mL−1, respectively. The accuracy and versatility of the present methodology were proved by analyzing ergotamine in real samples of different natures such as pharmaceuticals, urine and saliva.  相似文献   

4.
Pal BK  Singh KA  Dutta K 《Talanta》1992,39(8):971-975
A very simple, highly-sensitive and selective quenchofluorimetric method for the rapid determination of molybdenum(VI) in aqueous media is described. The method is based on the instantaneous quenching action by the metal-ion upon the native fluorescence of bathophenanthrolinedisulphonate (4,7-diphenyl-1,10-phenanthrolinedisulphonate) solution [lambda(ex) (max) 288 nm; lambda(em) (max) 444.8 nm] in the optimum pH-range of 3.0-3.7 at room temperature (25 +/- 5 degrees ). The fluorescence quenching is co-linear in the range of 0.01-1.0 ppm molybdenum. Large excesses of over 50 cations, anions and some common complexing agents were found to have no interference. Cu, Ni, Co, Fe and V can be tolerated only up to the corresponding amount of molybdenum. Interference from greater amounts can however be removed by a one-step ion-exchange separation process. The developed method was successfully tested over several standard alloys, synthetic mixtures of various compositions, factory effluents and in spiked environmental waters.  相似文献   

5.
Agrawal O  Das JV  Gupta VK 《Talanta》1998,46(4):501-505
A simple and sensitive method for the determination of isoproturon, a widely used herbicide is described here which is based on alkaline hydrolysis of isoproturon to its corresponding primary amine followed by diazotization and coupling with p-aminoacetophenone in alkaline medium. The absorption maxima of the coloured compound formed is measured at 525 nm. Beer's law is obeyed over the concentration range of 0.5-5.0 mug in a final solution volume of 25 ml (0.02-0.2 ppm). The molar absorptivity and Sandell's sensitivity were found to be 8.6x10(5) l mol(-1) cm(-1) and 0.0002 mug cm(-2), respectively. The method has been satisfactorily applied to the determination of isoproturon in environmental and biological samples.  相似文献   

6.
A rapid non-destructive activation analysis method has been developed for the determination of antimony. A high resolution low energy Ge detector is used to measure the 61.6 keV γ-ray from122mSb (T=4.2 min). Sensitivities and detection limits for biological and environmental samples activated with thermal and epithermal neutrons are listed. The time required for the anlaysis is about 12 min per sample using thermal activation and 22 minutes using epithermal activation analysis.  相似文献   

7.
A very simple, ultra-sensitive and fairly selective non-extractive spectrophotometric method for the determination of trace amounts of lead with 2,5-dimercapto-1,3,4-thiadiazole (DMTD) has been developed. DMTD reacts in slightly acidic (0.0015-0.01 M HCl) aquatic media with lead(II) to give a greenish-yellow chelate, which has an absorption maximum at 375 nm. The reaction is instantaneous and absorbance remains stable for 24 h. The average molar absorption coefficient and Sandell's sensitivity were found to be 4.93x10(4) lmol(-1)cm(-1) and 15 ngcm(-2) of Pb, respectively. Linear calibration graphs were obtained for 0.1-40 mugml(-1) of Pb; the stoichiometric composition of the chelate is 1:2 (Pb-DMTD). The interference from over 50 cations, anions and complexing agents has been studied at 1 mugml(-1) of Pb. The method developed was used successfully in the determination of lead in several standard reference materials (alloys and steels), environmental waters (potable and polluted), biological samples (human blood and urine), soil samples, solutions containing both lead(II) and lead(IV) and complex synthetic mixtures. The method has high precision and accuracy (S=+/-0.01 for 0.5 mugml(-1)).  相似文献   

8.
Some parameters affecting the accuracy of various approaches to methylmercury (MeHg) determination in biological and environmental samples were studied. Different isolation techniques (ion-exchange, extraction, volatilization, distillation) and final measurement via cold vapour atomic absorption spectroscopy (CV AA) or gas chromatography (GC) were compared. Results obtained by the various isolation techniques are comparable for almost all biological and environmental samples, except for soils and some sediments, where disagreement between the results obtained by GC and CV AA was found. In order to resolve these problems, a new separation technique based on distillation of MeHg from the sample followed either by CV AA or GC was developed. The new method results in very good recovery and reproducibility (95 ± 2%) for all samples examined (fish, mussel, shrimp, blood, hair, algae, sediment, etc.), is specific for MeHg and provides for its differentiation from other species by an indirect CV AA determination. Gas-chromatographic measurement of the isolated MeHg using different packings and conditioning of the columns is also discussed. The distillation method with GC detection is advantageous in producing cleaner chromatograms and in prolonging the life-time of the packing and the intervals between reconditioning.  相似文献   

9.
This work reports the development of a selective, sensitive and rapid spectrofluorimetric method for the determination of reduced glutathione (GSH) in the presence of relatively high levels of cysteine (Cys) in clinical and biological samples using 1,3,5,7-tetramethyl-8-phenyl-(2-maleimide)-difluoroboradiaza-s-indacene (TMPAB-o-M). The fluorescence from TMPAB-o-M is strongly quenched by its maleimide moiety, but after reaction with thiol, the fluorescence is restored with a 350-fold intensity increase (fluorescence quantum yield from 0.002 to 0.73). In H3Cit-Na2HPO4 buffer (pH 7.40), the derivatization is completed in just 5 min under 37 °C. The linear range is 0.005-0.2 μmol L−1, with detection limit of 1.1 × 10−10 mol L−1 (signal-to-noise ratio = 3). Almost all amino acids, including Cys, impose no interference even if present at relatively high concentrations (amino acids:GSH = 100:1, Cys:GSH = 1:1, molar ratio, CGSH = 3 × 10−7 mol L−1). The sample can be used directly without further treatment after the protein is removed. The developed method is precise with a relative standard deviation (R.S.D.) lower than 5.0% (n = 6) and has been applied to the determination of GSH in human blood and pig’s liver with recoveries between 94.4 and 105.6%.  相似文献   

10.
A new thiol fluorescence probe, 5-maleimidyl-2-(m-methylphenyl)benzoxazole (MMPB) has been developed for the direct determination of reduced glutathione (GSH) in real samples. Compared to the reported N-substituted maleimide type of thiol reagents, the main advantage of MMPB is its rather high selectivity for GSH to cysteine (Cys), which often coexists with GSH in biological samples. Under mild conditions similar to the physiological environment, MMPB reacted with GSH to give a highly fluorescent derivative with the excitation and emission wavelengths of 299.2 and 355.8 nm, respectively. In the presence of 0.40-fold (molar ratio) of Cys, a linear relationship was found in the range of 0-1.62×10−7 mol l−1 with the detection limit (3σ) of 3.23×10−10 mol l−1 for GSH determination. Many other amino acids (100-fold) did not interfere with the determination. Since the molar ratio of Cys to GSH in mammalian tissues and blood does not exceed the value of 0.40:1, the proposed method has been used in the direct determination of GSH in these kinds of biological samples, such as human blood, pig’s liver and heart with the recoveries of 94.3-104.5%  相似文献   

11.
A radiochemical method is given to determine the specific activity of238Pu, and241Am from the global fallout in environmental and biological samples. The radiochemical recovery was for human livers Pu: 60–70%, Am: 40–60%; Bran: Pu: 50–70%, Am: 30–40%; Soil: Pu: 50–80%, Am: 30–50%. The resolution of the alpha-spectrum was for soils 30–40 keV and for livers and brans 40–60 KeV. To facilitate the wet ashing of large amounts of bran (15 kg), which are necessary to determine the presently very small activity concentrations of the transuranic elements in these types of samples, a fermentation process was employed. The procedure was tested by using NBS standard reference material and subsequently applied for the determination of Pu and Am from the global fallout in livers, plant tissues (bran), and soils.  相似文献   

12.
A simple, rapid and accurate spectrophotometric method is described for the determination of trace amounts of vanadium using variamine blue (VB) as a chromogenic reagent. The method is based on the oxidation of variamine blue to form a violetcolored species on reaction with vanadium(V), having an absorption maximum at 570 nm. Beer’s law is obeyed in the range of 0.1–2.0 μg ml?1. The molar absorptivity and Sandell’s sensitivity were found to be 1.65 × 104 l mol?1 cm?1 and 0.003 μg cm?2, respectively. Optimum reaction conditions were evaluated in order to delimit the linear range. The effect of interfering ions on the determination is described. The proposed method has been successfully applied to the determination of vanadium in steel, pharmaceutical, environmental, and biological samples.  相似文献   

13.
14.
This article has been retracted at the request of the Editors-in-Chief. Please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). REASON: Considerable concern was raised about the research purportedly conducted at Sri Venkateswara University, India with the alleged involvement of Professor P. Chiranjeevi. Questions were raised as to the volume of publications, the actual capacity (equipment, orientation and chemicals) of the laboratory in which Professor Chiranjeevi worked, the validity of certain of the research data identified in the articles, the fact that a number of papers appear to have been plagiarized from other previously published papers, and some aspects of authorship. Professor Chiranjeevi was given the opportunity to respond to these allegations. Thereafter, a committee was constituted by the University to look into these allegations. Based on the enquiry committee report, we have been informed by the head of the Department of Chemistry at Sri Venkateswara University that the university authorities have taken disciplinary action against Professor Chiranjeevi, as the university considers that there are grounds for such action. Therefore, based on the results of this investigation, the Editors-in-Chief are retracting this article.  相似文献   

15.
Vilchez J  Blanc R  Navalón A 《Talanta》1997,45(1):105-111
A spectrofluorimetric method for the simultaneous determination of 1-naphthylacetic acid (NAA) and 1-naphthalenacetamide (NAD) was developed. The sample solution containing both analytes was equilibrated with Sephadex QAE A-25 gel by agitation and then only NAA was fixed on gel, while the remaining NAD stayed in the solution. The relative fluorescence intensity of NAA fixed on Sephadex QAE A-25 gel was measured directly after packing the gel beads in a 1-mm silica cell, using a solid-phase attachment. NAD was determined spectrofluorimetrically in the solution. The wavelengths of excitation and emission chosen for the determination of NAA were 280 and 336 nm, respectively, and for NAD determination 222 and 337 nm, respectively. The applicable concentration range was 12-60 ng ml(-1) for NAA and 6-120 ng ml(-1) for NAD. The detection limit was 3 ng ml(-1) for NAA and 2 ng ml(-1) for NAD. The method was applied satisfactorily to the determination of NAA and NAD in commercial formulations of phytohormones and soil samples.  相似文献   

16.
Capabilities of instrumental neutron activation analysis (INAA), photon activation analysis with radiochemical separation (RPAA) and proton induced γ-ray emission (PIGE) for determination of fluorine in biological and environmental materials are compared in terms of detection limits, nuclear and other interferences. The lowest detection limit of 0.5 μg.g-1 was achieved by RPAA, the detection limit of the non destructive and interference-free PIGE method was by one order of magnitude higher, whereas two to three orders of magnitude higher detection limits compared to RPAA were obtained in INAA. A satisfactory agreement was found between the results obtained in this work and reference, mostly information values for several biological and environmental materials. However, higher values of two orders of magnitude were determined by RPAA and PIGE in NIST RM-8414 Bovine Muscle compared to the fluorine information value. The reason for this difference is the contamination of this material with Teflon, which occurred on its preparation and has not been taken into account in establishing the information value. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

17.
The determination of aflatoxin B1 (AFB1) in pistachio has been accomplished by normal and synchronous fluorimetry in combination with some multivariate calibration methods and derivative techniques. Extending the two-dimensional synchronous fluorescence scan to a three-dimensional total synchronous fluorescence scan was used to obtain the optimized Δλ for AFB1 in pistachio sample. The methods are based on the enhanced fluorescence of AFB1 by β-cyclodextrine in 10% (v/v) methanol-water solution. Twenty-six pistachio samples containing AFB1 in the range 0-15 ppb were used as calibration set. Eighteen combinational methods were tested to make best model for prediction of AFB1 and finally best results obtained using a method based on synchronous fluorimetry in combination with multiple linear regressions (MLR). For concentrations ranging from 0 to 15 ppb of AFB1 in 22 pistachio samples as prediction set, the values of root mean square difference (RMSD) and relative error of prediction (REP) using MLR were 0.328 and 4.453%, respectively were observed. Two naturally contaminated pistachio samples were analyzed by synchronous fluorimetry using MLR and compared with HPLC results.  相似文献   

18.
The method is based on the reaction of pyrimethamine with chloroacetaldehyde and measurement of the fluorescence of the resulting pyrimidoimidazole derivative. The limits of detection for pyrimethamine in ethanol, plasman and saliva were 2.7, 8.4 and 6.6 ng ml?1, respectively. Chloroquine and quinine do not interfere.  相似文献   

19.
A method for solid phase extraction of trace metals such as Cd2+, Cr6+, Cu2+, Fe3+, Mn2+, Ni2+, Pb2+ and Zn2+ using nanometer-sized alumina coated with chromotropic acid prior to determination by inductively coupled plasma atomic emission spectrometry (ICP-AES) has been developed. Various influencing parameters on the separation and preconcentration of trace metals, pH, flow rate, sample volume, amount of adsorbent, concentration of eluent and sorption kinetics have been studied. The detection limits for Cd2+, Cr6+, Cu2+, Fe3+, Mn2+, Ni2+, Pb2+ and Zn2+ were found to be 0.14, 0.62, 0.22, 0.54, 0.27, 0.28, 0.53 and 0.38 ng ml− 1, respectively. The adsorption capacity of the solid phase adsorption material is 10.3, 11.3, 14.5, 16.4, 15.1, 11.7, 15.4 and 16.8 mg g− 1 for Cd2+, Cr6+, Cu2+, Fe3+, Mn2+, Ni2+, Pb2+ and Zn2+, respectively. The preconcentration factor was obtained in the range of 50-100 for all studied metal ions. Coexisting ions over a high concentration range have not shown any significant effects on the determination of aforesaid metal ions. The accuracy of the proposed method was tested by standard reference materials (NIST 1643e: water, NIST 1573a: tomato leaves and NIST 1568a rice flour) and natural waters and the results obtained were in good agreement with the certified values.  相似文献   

20.
A fluorimetric method for rapid determination of Ni at trace and ultratrace levels [1 ng/ml- 1 g/ml] has been developed. It is based on the efficient quenching action of Ni (II) on the native fluoresence [ex(max) = 288 nm, em(max) = 444.8 nm] of 4,7-diphenyl 1,10-phenanthrolinedisulfonate (bathophenanthrolinedisulfonate) solution at low acidities. The method is very simple, rapid and accurate with high precision (R.S.D. = 0.66% at 50 ng/ml). The method has been applied directly to mineralised solutions of several real and environmental samples and the results of nickel determinations are in excellent agreement with the certified values. It is a quick single-step method that requires no clean-up.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号