首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 46 毫秒
1.
微波消解ICP-OES法测定PM2.5中金属元素   总被引:3,自引:0,他引:3  
重金属具有不可降解性,细颗粒物(PM2.5)中重金属可随呼吸进入体内,对人体构成潜在的威胁。因此,有必要针对颗粒物中重金属元素的测定方法进行研究。用玻璃纤维滤膜采样、密闭微波消解进行前处理,建立了电感耦合等离子体发射光谱仪(ICP-OES)测定PM2.5中铅、锌、铜、镉、铬的分析方法。考察了微波消解体系,通过信噪比选取了铅、锌、铜、镉、铬的最佳分析谱线和最优仪器测试条件,其结果为:(1)HNO3-H2O2消解体系比HNO3-HCl和HNO3-H2SO4消解体系更稳定、更彻底;(2)铅、锌、铜、镉、铬的最佳分析线分别为220.353,213.857,327.393,228.802,267.716 nm;(3)仪器最优测试条件为射频功率1 300 W,蠕动泵流速1.5 mL·min-1,冷却气流量15 L·min-1,载气流速0.8 L·min-1。本方法元素的检出限为2.02×10-3~8.20×10-3μg·mL-1,滤膜样品测定的相对标准偏差(RSD,n=6)为1.86%~2.82%,加标回收率为91.6%~103.7%。对重庆市中科院万州监测点细颗粒物中铅、锌、铜、镉、铬的含量进行了分析,结果表明:万州城区细颗粒物没有受到镉和铬的污染,细颗粒物中铅处于潜在污染水平,锌和铜处于轻度污染水平。  相似文献   

2.
ICP-OES/ICP-MS测定煤中多种元素的微波消解方法研究   总被引:3,自引:0,他引:3  
对比了不同温度以及HNO3,HNO3/H2O2,HNO3/HF和HNO3/HF+H3BO3等四种用酸对煤样微波消解效果和元素检测的影响。以SARM20作为煤标准物质。建立了一套两步微波消解及多元素检测方法。即用9mL的HNO3与1mL的HF分解0.1g煤样,再加入10mL 4%(ρ)的H3BO3中和过量HF及氟化物沉淀。使用ICP-OES检测Al,Ca,Fe,Mg,K,Na,S,Si,Sr和Ti等十种矿物元素,元素回收率在87.5%~98.8%;使用ICP-MS检测Li,Be,Sc,V,Cr,Mn,Co,Ni,Cu,Zn,Ga,As,Se,Zr,Sn,Cs,Ba,Ce,Eu和Pb等20种重金属元素,元素回收率在85%~112.5%。各元素检测的RSD均小于3%。  相似文献   

3.
微波消解ICP-OES快速测定难溶钒钛磁铁矿中铁、钛、钒   总被引:5,自引:0,他引:5  
建立了添加络合剂A进行微波消解难溶钒钛磁铁矿,电感耦合等离子体发射光谱(ICP-OES)测定其中铁、钛、钒的方法。通过正交实验确定的最优消解条件是:0.1g钒钛磁铁矿;12mL浓盐酸;0.04g络合剂A;消解时间10min;微波功率385W。用新建立的方法对攀枝花钢铁研究院的钒钛磁铁矿(GBW07226)进行消解,用ICP-OES法对Fe,Ti,V进行测定,测定的相对误差和相对标准偏差均达到分析化学的要求。新建立的方法中,添加络合剂与溶解出的金属离子络合,使得试样与溶解介质盐酸的接触面不断更新,显著加速了矿物的溶解,用ICP-OES法测定消解液,实现了多种主量、微量元素同时测定。该法试剂用量少、经济;样品消解、测定迅速;对环境友好;适合大批量样品快速测定。建立的方法对国家商检部门、相关分析测试单位等具备实际应用价值。  相似文献   

4.
微波消解-ICP-AES法测定石油焦中硫   总被引:2,自引:0,他引:2  
本方法采用微波消解-ICP-AES法测定石油焦中的硫,具有快速、简便、准确等特点,并有较好的重复性和准确性。该法回收率为97%-99%,检出限为0.008μg/g。适用于石油焦中硫含量的分析。  相似文献   

5.
微波消解-ICP-AES同时测定维吾尔医药中多种元素含量   总被引:3,自引:1,他引:2  
为了解维吾尔医药的药效与微量元素之间的关系,用ICP-AES同时测定了5种维吾尔医药中的10种微量元素,用微波消化法处理样品,进行了方法的准确度和精密度试验,方法简便、快速,准确,结果令人满意。  相似文献   

6.
分别采用HNO3,HNO3/HF和HNO3/HF+H3BO3三种不同消解用酸微波消解石膏样品.用ICP-OES检测石膏中的Al,Ca,Fe,Mg,K,Na,S,Ti,Si和Sr,用ICP-MS检测石膏中的V,Cr,Mn,Zn,Se和Ce.采用GBW03109a,GBW03110和FGD-2作为石膏标准物质.检测值与样品标准值的对比结果表明,使用HNO3/HF+H3BO3样晶消解最完全.建立了用9 mL HNO3和1 mL HF分解0.2 g石膏,再加入10 mL 4%(ρ)的H3BO3中和过量的HF及氟化物沉淀的两步微波加热消解方法.该方法检测3种石膏标准物质时,元素回收率为88%~112%,RSD均小于3%.利用该方法测定了3种实际燃煤电厂脱硫石膏样品中的元素含量.  相似文献   

7.
微波消解-火焰光度法测定叶片中钾和钠含量   总被引:1,自引:0,他引:1  
本文研究了灰化法、常压湿法消解和微波消解3种方法处理植物叶片对火焰光度法测定K、Na含量的影响。结果表明:微波消解法具有消化时间短、样品污染少,测定结果准确,重现性好等特点,加标回收率符合测试要求。  相似文献   

8.
微波消解-ICP-AES测定保鲜水果中硫含量   总被引:1,自引:0,他引:1  
用硝酸-过氧化氢(4+2)混合溶液作为消解剂,微波消解法处理保鲜水果样品,采用电感耦合等离子体-原子发射光谱法(ICP-AES)测定所得样品溶液中硫的含量,选择182.0nm为测定硫的分析线,硫的检出限(3Sd)为0.065mg·L-1,样品测定的相对标准偏差(n=8)为1.90%用本法测定两个国家标准物质茶叶(GBW...  相似文献   

9.
迟明玉 《光谱实验室》2011,28(4):2063-2065
采用电感耦合等离子体-发射光谱法(ICP-OES)测定了铜尾矿中锡的含量.该方法检出限为0.006%,加标回收率为98.3%-102.8%.对国标样品的测定结果令人满意.方法简单快捷,对矿物中锡含量的测定具有参考意义.  相似文献   

10.
邵波  王琦峰  梅瑜 《光谱实验室》2012,29(2):1133-1135
采用微波消解和ICP-OES测定了凤仙花和红花中重金属铜、铅、镍和稀土元素铈、钐、镧的含量。该方法的加标回收率为93.1%—103.8%,相对标准偏差(RSD)值不大于1.83%。实验结果表明,所测样品含量均未超过国家规定标准,适合入药。方法快速简便可靠。  相似文献   

11.
Methyltin mercaptide is widely used as one of the best heat stabilizer in the polyvinylchloride (PVC) thermal processing due to its excellent stability, good transparency, high compatibility and weather resistance. The content of sulfur and tin significantly affects its quality and performance, so it is of great significance to develop an analytical method for the simultaneous determination of sulfur and tin. Inductively coupled plasma atomic emission spectrometry (ICP-OES) has been a powerful analytical tool for a myriad of complex samples owing to its advantages of the low detection limits, rapid and precise determinations over wide dynamic ranges, freedom from chemical inter-element interferences, the high sample throughput and above all, simultaneous multi-elements analysis. Microwave technique as a well-developed method for sample preparation can dramatically reduce the digestion time and the loss of volatile elements compared with the traditional open digestion. Hereby, a microwave-assisted acid digestion (MW-AAD) procedure followed by inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis was developed for the simultaneous determination of Sn and S in methyltin mercaptide. This method has the advantages of simplicity, rapidness, good accuracy, green and less use of samples. Parameters affecting the MW-AAD such as the digestion solution and digestion time were optimized by using a chemical analyzed reference sample (DX-181) to attain tin and sulfur quantitative recoveries. HNO3-HCl-HClO4(v/v/v=9 : 3 : 1) and 10 min were the optimum digestion solution and digestion time, respectively. Under optimum conditions, the standard addition method and the standard calibration curve method were both been used to detect Sn and S in DX-181. There was no significant difference between two methods and the relative deviations to the chemical analysis values were both less than 2%. Additionally, the accuracy of the MW-AAD method was examined by analyzing three methyltin mercaptide samples (DX-181, DX-990, DX-960). The results were satisfactory with the relative deviations (<3%) and the recoveries of standard addition (99%-102%).  相似文献   

12.
微波消解-ICP-OES测定石灰石样品中的多种元素   总被引:2,自引:1,他引:1  
王珲  宋蔷  杨锐明  姚强  陈昌和 《光谱实验室》2010,27(5):1925-1928
采用微波消解预处理石灰石样品,并利用ICP-OES测定石灰石中Si、Ca、Al、Fe、Mg、K、Ti、Sr和Mn等矿物元素含量。以GBW07120和GBW07214a作为石灰石标准物质。对比了HNO3,HNO3/HF和HNO3/HF+H3BO33种不同消解用酸微波消解石灰石样品后对元素回收率的影响。通过检测值与样品标准值的对比,使用HNO3/HF+H3BO3后样品消解最完全。建立了用9mLHNO3和1mLHF分解0.2g石灰石,再加入10mL4%(W/V)的H3BO3中和过量的HF及氟化物沉淀的两步微波加热消解方法。本方法检测2种石灰石标准物质时,元素回收率在88.5%—104.1%之间,RSD均小于3%。  相似文献   

13.
采用微波消解-电感耦合等离子发射光谱法(ICP-OES),测定60日龄和90日龄大鼠股骨中Al、As、B、Ba、Be、Bi、Ca、Cd、Co、Cr、Cu、Fe、Ga、K、Li、Mg、Mn、Na、Ni、P、Pb、S、Sb、Sr、Ti、Tl、V和Zn等28种元素含量;股骨采用HNO3-H2O2酸溶体系进行微波消解.结果显示,该方法检出限在0.001-1.689μg/mL之间;通过添加标准回收实验,回收率在81.51%-106.91%之间;RSD在0.2441%-9.8592%之间;与传统方法相比,该方法具有良好的准确度和精密度,为不同生物样品中元素含量的测定提供了参考.  相似文献   

14.
微波消解-ICP-OES测定滇杨中的矿质元素   总被引:2,自引:0,他引:2  
赵宁  钱璐  孟刚  杨斌  徐娟 《光谱实验室》2011,28(5):2347-2350
采用微波消解法消解样品,利用电感耦合等离子体-发射光谱法(ICP-OES)测定滇杨中的矿质元素.方法的RSD为0.5%-3.8%,加标回收率为96.7%-104.4%,表明该方法有良好的精密度和准确度.用该法对滇杨样品中的钙、镁、铁、锌、钾、锰、磷、硼、铜、钠、硅等11种矿质元素进行测定,发现铜含量明显偏低,不能达到植...  相似文献   

15.
微波消解与ICP-OES/ICP-MS测定飞灰中的多种元素   总被引:1,自引:0,他引:1  
研究了不同温度以及HNO3、HNO3/H2O2、HNO3/HF和HNO3/HF+H3BO34种酸对飞灰微波消解效果和元素分析的影响.以NIST-1633b为飞灰标准物质.建立了用HNO3/HF (9mL+ 1mL)分解0.05g飞灰,再加入10mL 4%(ρ)的H3BO3中和过量HF及氟化物沉淀的两步微波消解方法.并利用ICP-OES检测了Al、Ca、Fe、Mg、K、Na、S、Si和Ti等9种矿物元素,元素回收率在92%-105%之间;利用ICP-MS检测了V、Cr、Mn、Co、Ni、Cu、Zn、As、Se、Sr、Cs、Ba、Eu和Pb等14种重金属元素,元素回收率在83%-109%之间.各元素检测的RSD均小于3%.  相似文献   

16.
微波消解-ICP-OES测定青海野生黄蘑菇中的矿质元素   总被引:2,自引:0,他引:2  
经湿法微波消解制样,利用全谱直读电感耦合等离子体-发射光谱法(ICP-OES)对青海野生黄蘑菇中的矿质元素进行全面详细的分析测定。测定结果表明,野生黄蘑菇中含有K、P、S、Mg、Ca、Fe、Al、Na、Zn、Cu、Mn、Cd、Ti、B、Ba、Cr、Sr 17种矿质元素,常量矿质元素中K、P、S的含量较高,微量元素中,Fe、Zn和Cu含量丰富,同时含有一定量的Cd元素,未检出Se元素。分析方法回收率在92.2%—108.8%之间,RSD为0.79%—9.05%。该方法简单、快速、可靠、灵敏度高,且多元素可同时测定,能满足实际样品分析要求。分析结果可为青海野生黄蘑菇的开发利用研究提供参考。  相似文献   

17.
ICP-OES测定复混肥料中钙、镁和硫   总被引:1,自引:1,他引:0  
宋吉利  刘华  孙科深 《光谱实验室》2006,23(6):1185-1187
本文研究了ICP-OES测定复混肥料中钙、镁和硫等3种元素的方法.此法准确可靠、简便快捷,大大提高了测定复混肥料中中量元素测定的效率.方法回收率在99.0%-102.4%之间,相对标准偏差小于3.0%,方法的检出限(3σ)为0.0004-0.7mg/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号