首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND AND PURPOSE: The purpose of this study was to assess the use of diffusion tensor imaging (DTI) in the evaluation of new contrast-enhancing lesions and perilesional edema in patients previously treated for brain neoplasm in the differentiation of recurrent neoplasm from treatment-related injury. METHODS: Twenty-eight patients with new contrast-enhancing lesions and perilesional edema at the site of previously treated brain neoplasms were retrospectively reviewed. Nine directional echoplanar DTIs with b=1000 s/mm(2) were obtained using a single-shot spin-echo echoplanar imaging. Standardized regions of interest were manually drawn in several regions. Mean apparent diffusion coefficient (ADC), fractional anisotropy (FA) and eigenvalue indices (lambda( parallel) and lambda( perpendicular)) and their ratios relative to the contralateral side were compared in patients with recurrent neoplasm versus patients with radiation injury, as established by histological examination or by clinical course, including long-term imaging studies and magnetic resonance spectroscopy. RESULTS: The ADC values in the contrast-enhancing lesions were significantly higher (P=.01) for the recurrence group (range=1.01 x 10(-3) to 1.66 x 10(-3) mm(2)/s; mean+/-S.D.=1.27+/-0.15) than for the nonrecurrence group (range=0.9 x 10(-3) to 1.31 x 10(-3) mm(2)/s; mean+/-S.D.=1.12+/-0.14). The ADC ratios in the white matter tracts in perilesional edema trended higher (P=.09) in treatment-related injury than in recurrent neoplasm (mean+/-S.D.=1.85+/-0.30 vs. 1.60+/-0.27, respectively). FA ratios were significantly higher in normal-appearing white matter (NAWM) tracts adjacent to the edema in the nonrecurrence group (mean+/-S.D.=0.89+/-0.15) than in those in the recurrence group (mean+/-S.D.=0.74+/-0.14; P=.03). Both eigenvalue indices lambda( parallel) and lambda( perpendicular) were significantly higher in contrast-enhancing lesions in the recurrence group than in those in the nonrecurrence group (P=.02). As well, both eigenvalue indices lambda( parallel) and lambda( perpendicular) were significantly higher in perilesional edema than in normal white matter (P<.01 and P<.001, respectively) in both groups. CONCLUSION: The assessment of diffusion properties, especially ADC values and ADC ratios, in contrast-enhancing lesions, perilesional edema and NAWM adjacent to the edema in the follow-up of new contrast-enhancing lesions at the site of previously treated brain neoplasms may add to the information obtained by other imaging techniques in the differentiation of radiation injury from tumor recurrence.  相似文献   

2.
Quantitative, multislice dynamic susceptibility contrast-enhanced MRI perfusion measurements were used to determine the patterns of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and normalized first moment of the tissue deltaR2-time curve (N) in 11 subjects with carotid artery occlusion or stenosis. MTT correlated with degree of carotid stenosis, whereas a range of alterations in CBF and CBV were found presumably reflecting variables degrees of collateral flow. There was no significant correlation between MRI and SPET flow perfusion measurements, with increasing disparity between the two techniques at higher inter-hemispheric flow ratios. The effect of obtaining the arterial input function (AIF) from the middle cerebral artery (MCA) ipsilateral or contralateral to the stenosis was determined. Despite the use of an AIF from the MCA, which is distal to the circle of Willis, and hence the major sources of collateral supply, there was still some extra dispersion of the contrast agent bolus due to differences in arrival time.  相似文献   

3.
The arterial input function (AIF) is important for quantitative MR imaging perfusion experiments employing Gd contrast agents. This study compared the accuracy of T(2)*-weighted magnitude and phase imaging for noninvasive measurement of the AIF in the rat aorta. Twenty-eight in vivo experiments were performed involving simultaneous arterial blood sampling and MR imaging following Gd injection. In vitro experiments were also performed to confirm the in vivo results. At 1.89 T and TE=3 ms, the relationship between changes in 1/T(2)* in blood (estimated from MR signal magnitude) and Gd concentration ([Gd]) was measured to be approximately 19 s(-1) mM(-1), while that between phase and [Gd] was approximately 0.19 rad mM(-1). Both of these values are consistent with previously published results. The in vivo phase data had approximately half as much scatter with respect to [Gd] than the in vivo magnitude data (r(2)=.34 vs. r(2)=.17, respectively). This is likely due to the fact that the estimated change in 1/T(2)* is more sensitive than the phase to a variety of factors such as partial volume effects and T(1) weighting. Therefore, this study indicates that phase imaging may be a preferred method for measuring the AIF in the rat aorta compared to T(2)*-weighted magnitude imaging.  相似文献   

4.
Conflicting results reported on the effects of hyperoxia on cerebral hemodynamics have been attributed mainly to methodical and species differences. In the present study contrast-enhanced magnetic resonance imaging (MRI) perfusion measurement was used to analyze the influence of hyperoxia (fraction of inspired oxygen (FiO2) = 1.0) on regional cerebral blood flow (rCBF) and regional cerebral blood volume (rCBV) in awake, normoventilating volunteers (n = 19). Furthermore, the experiment was repeated in 20 volunteers for transcranial Doppler sonography (TCD) measurement of cerebral blood flow velocity in the middle cerebral artery (CBFV(MCA)). When compared to normoxia (FiO2 = 0.21), hyperoxia heterogeneously influenced rCBV (4.95 +/- 0.02 to 12.87 +/- 0.08 mL/100g (FiO2 = 0.21) vs. 4.50 +/- 0.02 to 13.09 +/- 0.09 mL/100g (FiO2 = 1.0). In contrast, hyperoxia diminished rCBF in all regions (68.08 +/- 0.38 to 199.58 +/- 1.58 mL/100g/min (FiO2 = 0.21) vs. 58.63 +/- 0.32 to 175.16 +/- 1.51 mL/100g/min (FiO2 = 1.0)) except in parietal and left frontal gray matter. CBFV(MCA) remained unchanged regardless of the inspired oxygen fraction (62 +/- 9 cm/s (FiO2 = 0.21) vs. 64 +/- 8 cm/s (FiO2 = 1.0)). Finding CBFV(MCA) unchanged during hyperoxia is consistent with the present study's unchanged rCBF in parietal and left frontal gray matter. In these fronto-parietal regions predominantly fed by the middle cerebral artery, the vasoconstrictor effect of oxygen was probably counteracted by increased perfusion of foci of neuronal activity controlling general behavior and arousal.  相似文献   

5.
Histology, including immunohistochemistry, and magnetic resonance imaging microscopy (microMRI) are complementary techniques for the analysis of brain structure. Therefore, microMRI analysis, often of formalin-fixed tissue, precedes histologic evaluation of the same experimental animal in many studies. However, the application of gadopentetate dimeglumine (Gd-DTPA), while of value for MRI studies, has an unknown effect on subsequent histology. We demonstrate here that for the mouse brain, histology with Nissl staining and immunostaining for microtubule-associated protein 2, using standard techniques for tissue preparation, are unaffected by prior perfusion of the tissue with Gd-DTPA. This conclusion was based on qualitative morphologic comparisons of stained sections, as well as quantification of mean immunofluorescence pixel intensities from Gd-treated (mean+/-S.D.=131.2+/-28.4; n=3) as compared to nontreated specimens (116.2+/-34.7; n=3, P=.7). Therefore, Gd-DTPA may be applied as a microMRI contrast agent in formalin-fixed brain tissue prior to histologic studies.  相似文献   

6.
Comparison of multi-echo spiral and echo planar imaging in functional MRI   总被引:2,自引:0,他引:2  
Multi-echo spiral and echo-planar (EPI) imaging sequences were compared in functional imaging experiments at 3 Tesla. Both sequence types allow calculation of the effective transversal relaxation time T(2)* and the initial signal intensity I(0). These parameters can be used in evaluation of the functional signal with respect to inflow effects and other vascular sources. Prior to functional magnetic resonance imaging (fMRI) experiments T(2)* measurements in the human brain were performed with single- and multi-echo FLASH (fast low angle shot) and compared with EPI und spiral imaging sequences. These experiments resulted in T(2)* values ranging from 42.9 to 53.8 ms in a ROI including white and gray matter and CSF in a prefrontal brain region, and allowed validation of the quantitative results of the fast single-shot techniques. In functional experiments with motor stimulation mean absolute T(2)* increases during stimulation of 1.1 +/- 0.6 ms and 1.4 +/- 0.9 ms were found with multi-echo EPI and spiral imaging, respectively, averaged over the activated pixels. In addition, absolute T(2)* values and the size of activated areas obtained with both sequences are comparable. In these investigations spiral imaging allowed higher spatial resolution due to more efficient use of available gradient performance.  相似文献   

7.
This study compared two methods, corrected (separation of T(1) and T(2)* effects) and uncorrected, in order to determine the suitability of the perfusion and permeability measures through Delta R(2)* and Delta R(1) analyses. A dynamic susceptibility contrast dual gradient echo (DSC-DGE) was used to image the fixed phantoms and flow phantoms (Sephadex perfusion phantoms and dialyzer phantom for the permeability measurements). The results confirmed that the corrected relaxation rate was linearly proportional to gadolinium-diethyltriamine pentaacetic acid (Gd-DTPA) concentration, whereas the uncorrected relaxation rate did not in the fixed phantom and simulation experiments. For the perfusion measurements, it was found that the correction process was necessary not only for the Delta R(1) time curve but also for the Delta R(2)* time curve analyses. Perfusion could not be measured without correcting the Delta R(2)* time curve. The water volume, which was expressed as the perfusion amount, was found to be closer to the theoretical value when using the corrected Delta R(1) curve in the calculations. However, this may occur in the low concentration of Gd-DTPA in tissue used in this study. For the permeability measurements based on the two-compartment model, the permeability factor (k(ev); e = extravascular, v = vascular) from the outside to the inside of the hollow fibers was greater in the corrected Delta R(1) method than in the uncorrected Delta R(1) method. The differences between the corrected and the uncorrected Delta R(1) values were confirmed by the simulation experiments. In conclusion, this study proposes that the correction for the relaxation rates, Delta R(2)* and Delta R(1), is indispensable in making accurate perfusion and permeability measurements, and that DSC-DGE is a useful method for obtaining information on perfusion and permeability, simultaneously.  相似文献   

8.
This Letter presents the first strong evidence for the resolution of the excited B mesons B(1) and B(2)* as two separate states in fully reconstructed decays to B(+)(*)pi(-). The mass of B(1) is measured to be 5720.6+/-2.4+/-1.4 MeV/c(2) and the mass difference DeltaM between B(2)* and B(1) is 26.2+/-3.1+/-0.9 MeV/c;{2}, giving the mass of the B(2)* as 5746.8+/-2.4+/-1.7 MeV/c(2). The production rate for B(1) and B(2)* mesons is determined to be a fraction (13.9+/-1.9+/-3.2)% of the production rate of the B+ meson.  相似文献   

9.
To prevent systematic errors in quantitative brain perfusion studies using dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI), a reliable determination of the arterial input function (AIF) is essential. We propose a novel algorithm for correcting distortions of the AIF caused by saturation of the peak amplitude and discuss its relevance for longitudinal studies. The algorithm is based on the assumption that the AIF can be separated into a reliable part at low contrast agent concentrations and an unreliable part at high concentrations. This unreliable part is reconstructed, applying a theoretical framework based on a transport-diffusion theory and using the bolus-shape in the tissue. A validation of the correction scheme is tested by a Monte Carlo simulation. The input of the simulation was a wide range of perfusion, and the main aim was to compare this input to the determined perfusion parameters. Another input of the simulation was an AIF template derived from in vivo measurements. The distortions of this template was modeled via a Rician distribution for image intensities. As for a real DSC-MRI experiment, the simulation returned the AIF and the tracer concentration-dependent signal in the tissue. The novel correction scheme was tested by deriving perfusion parameters from the simulated data for the corrected and the uncorrected case. For this analysis, a common truncated singular value decomposition approach was applied. We find that the saturation effect caused by Rician-distributed noise leads to an overestimation of regional cerebral blood flow and regional cerebral blood volume, as compared to the input parameter. The aberration can be amplified by a decreasing signal-to-noise ratio (SNR) or an increasing tracer concentration. We also find that the overestimation can be successfully eliminated by the proposed saturation-correction scheme. In summary, the correction scheme will allow DSC-MRI to be expanded towards higher tracer concentrations and lower SNR and will help to increase the measurement to measurement reproducibility for longitudinal studies.  相似文献   

10.
OBJECTIVE: The aim of this study was to label human umbilical cord blood mesenchymal stem cells (MSCs) with poly-l-lysine (PLL)-conjugated superparamagnetic iron oxide particles and to obtain magnetic resonance (MR) images of the labeled MSCs' suspension at 1.5 T. MATERIAL AND METHODS: PLL was conjugated with iron oxide to form superparamagnetic particles called Fe(2)O(3)-PLL. Human umbilical cord blood MSCs were isolated, purified, expanded and incubated with Fe(2)O(3)-PLL. Prussian blue stain was performed to show intracellular iron; spectrometry was used to quantify iron uptake within cells. Tetrazolium salt (MTT) assay was applied to evaluate toxicity and proliferation of MSCs labeled with various concentrations of Fe(2)O(3)-PLL. The cell apoptosis rate was determined by annexin V/propichium iodide (PI) double staining method. Vials containing cells underwent MR imaging (MRI) with T(1), T(2) and T(2)* weighted MRI. RESULTS: Iron-containing intracytoplasmatic vesicles could be observed clearly with Prussian blue staining in all samples except the unlabeled control. The iron content per cell determined by spectrometry was 64.51+/-10.32 pg. Among MSCs with and without labeling of various concentrations of Fe(2)O(3)-PLL, MTT values of light absorption had no statistically significant difference (Kruskal-Wallis test, chi(2)=10.35, P=.17). A concentration at 20 mug/ml of iron appeared most suitable for incubating cells. Of labeled and unlabeled MSCs, the early [annexin V-fluorescein isothiocyanate (FITC)-positive/PI-negative] and late (annexin V-FITC-positive/PI-positive) apoptotic cells were 10.34+/-0.43%/11.36+/-1.30% and 4.01+/-1.76%/2.98+/-1.37%, respectively, and there were no significant differences between them (P>.05). T(2) weighted image (WI) and T(2)*WI demonstrated significant decrease of signal intensity (SI) in vials containing 1 x 10(6) (1 day), 1x10(6) (8 days) and 5 x 10(5) labeled cells, in comparison with unlabeled cells (P<.05). The percentage change of SI (DeltaSI) was significantly higher in 10(6) labeled cells after 1-day culture than that in the same number of labeled cells after 8-day culture and that in 5 x 10(5) labeled cells, particularly on T(2)*WI (P<.05). Among pulse sequences, T(2)*WI demonstrated the highest DeltaSI (P<.05). CONCLUSION: The human umbilical cord blood MSCs can be labeled with Fe(2)O(3)-PLL without significant change in viability and apoptosis. The suspension of labeled MSCs can be imaged with standard 1.5-T MR equipment.  相似文献   

11.
In this study we present a novel automated strategy for predicting infarct evolution, based on MR diffusion and perfusion images acquired in the acute stage of stroke. The validity of this methodology was tested on novel patient data including data acquired from an independent stroke clinic. Regions-of-interest (ROIs) defining the initial diffusion lesion and tissue with abnormal hemodynamic function as defined by the mean transit time (MTT) abnormality were automatically extracted from DWI/PI maps. Quantitative measures of cerebral blood flow (CBF) and volume (CBV) along with ratio measures defined relative to the contralateral hemisphere (r(a)CBF and r(a)CBV) were calculated for the MTT ROIs. A parametric normal classifier algorithm incorporating these measures was used to predict infarct growth. The mean r(a)CBF and r(a)CBV values for eventually infarcted MTT tissue were 0.70 +/- 0.19 and 1.20 +/- 0.36. For recovered tissue the mean values were 0.99 +/- 0.25 and 1.87 +/- 0.71, respectively. There was a significant difference between these two regions for both measures (p < 0.003 and p < 0.001, respectively). Mean absolute measures of CBF (ml/100g/min) and CBV (ml/100g) for the total infarcted territory were 33.9 +/- 9.7 and 4.2 +/- 1.9. For recovered MTT tissue, the mean values were 41.5 +/- 7.2 and 5.3 +/- 1.2, respectively. A significant difference was also found for these regions (p < 0.009 and p < 0.036, respectively). The mean measures of sensitivity, specificity, positive and negative predictive values for modeling infarct evolution for the validation patient data were 0.72 +/- 0.05, 0.97 +/- 0.02, 0.68 +/- 0.07 and 0.97 +/- 0.02. We propose that this automated strategy may allow possible guided therapeutic intervention to stroke patients and evaluation of efficacy of novel stroke compounds in clinical drug trials.  相似文献   

12.
The hypercapnia induced by carbogen (95% O(2)/5% CO(2)) breathing, which is being re-evaluated as a clinical radiosensitiser, causes patient discomfort and hence poor compliance. Recent preclinical and clinical studies have indicated that the CO(2) content might be lowered without compromising increased tumour oxygenation and radiosensitisation. This preclinical study was designed to see if lower levels of hypercapnia could evoke similar decreases in the transverse relaxation rate R(2)* of rodent tumours to those seen with carbogen breathing. The response of rat GH3 prolactinomas to 1%, 212% and 5% CO(2) in oxygen, and 100% O(2) breathing, was monitored by non-invasive multi-gradient echo MRI to quantify R(2)*. As the oxygenation of haemoglobin is proportional to the blood p(a)O(2) and therefore in equilibrium with tissue pO(2), R(2)* is a sensitive indicator of tissue oxygenation. Hyperoxia alone decreased R(2)* by 13%, whilst all three hypercapnic hyperoxic gases decreased R(2)* by 29%. Breathing 1% CO(2) in oxygen evoked the same decrease in R(2)* as carbogen. The DeltaR(2)* response is primarily consistent with an increase in blood oxygenation, though localised increases in tumour blood flow were also identified in response to hypercapnia. The data support the concept that levels of hypercapnia can be reduced without loss of enhanced oxygenation and hence potential radiotherapeutic benefit.  相似文献   

13.
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can assess tumor perfusion, microvascular vessel wall permeability and extravascular-extracellular volume fraction. Analysis of DCE-MRI data is usually based on indicator dilution theory that requires knowledge of the concentration of the contrast agent in the blood plasma, the arterial input function (AIF). A method is presented that compares the tissues of interest (TOI) curve shape to that of a reference region (RR), thereby eliminating the need for direct AIF measurement. By assigning literature values for Ktrans (the blood perfusion-vessel permeability product) and v(e) (extravascular-extracellular volume fraction) in a reference tissue, it is possible to extract the Ktrans and v(e) values for a TOI without knowledge of the AIF. The operational RR equation for DCE-MRI analysis is derived, and its sensitivity to noise and incorrect assignment of the RR parameters is tested via simulations. The method is robust at noise levels of 10%, returning accurate (+/-20% in the worst case) and precise (+/-15% in the worst case) values. Errors in the TOI Ktrans and v(e) values scale approximately linearly with the errors in the assigned RR Ktrans and v(e) values. The methodology is then applied to a Lewis Lung Carcinoma mouse tumor model. A slowly enhancing TOI yielded Ktrans=0.039+/-0.002 min-1 and v(e)=0.46+/-0.01, while a rapidly enhancing region yielded Ktrans=0.35+/-0.05 min-1 and v(e)=0.31+/-0.01. Parametric Ktrans and v(e) mappings manifested a tumor periphery with elevated Ktrans (>0.30 min-1) and v(e) (>0.30) values. The main advantage of the RR approach is that it allows for quantitative assessment of tissue properties without having to obtain high temporal resolution images to characterize an AIF. This allows for acquiring images with higher spatial resolution and/or SNR, and therefore, increased ability to probe tissue heterogeneity.  相似文献   

14.
Development of a deterministic algorithm for automated detection of the Arterial Input Function (AIF) in DCE-MRI of colorectal cancer.Using a filter pipeline to determine the AIF region of interest. Comparison to algorithms from literature with mean squared error and quantitative perfusion parameter Ktrans.The AIF found by our algorithm has a lower mean squared error (0.0022 ± 0.0021) in reference to the manual annotation than comparable algorithms. The error of Ktrans (21.52 ± 17.2%) is lower than that of other algorithms.Our algorithm generates reproducible results and thus supports a robust and comparable perfusion analysis.  相似文献   

15.
We use data collected by the CLEO III detector at the Cornell Electron Storage Ring to measure the inclusive yields of D(s) mesons as B(Y(5S) --> D(s)X) = (44-7 +/- 4.2 +/- 9.9)% and B(Y(4S) --> D(s)X) = (18.1 +/- 0.5 +/- 2.8)%. From these measurements, we make a model dependent estimate of the ratio of B(s)*B(s)* to the total bb quark pair production of (16.0 +/- 2.6 +/- 5.8)% at the Y(5S) energy.  相似文献   

16.
We investigated the effects of transcranial magnetic stimulation (TMS) coils and electroencephalographic (EEG) electrodes on T(2)*-weighted echo-planar images (EPI) at 2.0 T (gradient-echo EPI, mean TE = 53 ms, 2x2x4 mm(3)). In comparison with anatomic gradient-echo images (3D FLASH, TE = 4 ms, 1x1x1 mm(3)), T(2)*-weighted EPI acquisitions of a water-filled spherical phantom revealed severe signal losses and geometric distortions in the vicinity of TMS coils. Even remote effects were observed for image orientations perpendicular to the coil plane. EEG electrodes and the fixation gel caused milder localized distortions. In humans, complications were avoided by the large distance between the TMS coil and the cortical surface and when using an EPI orientation parallel to the plane of the coil. It is concluded that T(2)*-weighted EPI studies of human brain function may be performed without distortions caused by TMS coils and EEG electrodes.  相似文献   

17.
Quantitative perfusion imaging of human kidneys was performed using arterial spin labeling MRI with a fast spin echo readout-sequence. Perfusion maps of centrally located single slices were obtained in axial and coronal orientations. In ten healthy volunteers, the mean value of perfusion was 213+/-55 mL/(100g min) with a range from 140 to 319 mL/(100g min). These results are in accordance with literature data, considering the fact that FAIR only measures the perfusion component normal to the imaging plane. Intra-individual reproducibility errors of +/-11% were smaller than the natural interindividual variability of renal perfusion (SD = +/- 25%). Perfusion in the cortex was approximately 3-4 times higher compared to the medulla. Considering the relatively high resolution of 2x2x10 mm3, the ability to quantify perfusion, and the lack of ionizing radiation and contrast media, this technique should prove useful in diagnosing renal pathologies that are associated with reductions in tissue perfusion.  相似文献   

18.
The main objective of this article was (i) to refocus the residual dipolar and quadrupolar interactions in anisotropic tissues employing magic sandwich echo (MSE) imaging and to compare the results with that of conventional spin-echo (SE) imaging, and (ii) to quantify MSE relaxation and dispersion characteristics in bovine Achilles tendon and compare with spin-lattice relaxation time constant in the rotating frame (T(1rho)). Magic sandwich echo weighted images are approximately 75-100% higher in signal-to-noise ratio than the corresponding T(2)-weighted images. Magic sandwich echo relaxation times varied from 13+/-2 to 19+/-3 ms (mean+/-S.D.), depending upon the structural location of tendon. T(2) relaxation times only varied from 4+/-1 to 10+/-3 ms (mean+/-S.D.) on the same corresponding locations. Magic sandwich echo provides approximately 100% enhancement in relaxation times compared to T(2). Preliminary results based on bovine Achilles tendon and cartilage specimens suggest that the MSE technique has potential for refocusing residual dipolar as well as quadrupolar interactions in anisotropic systems and yields higher intensities than conventional SE imaging as well as T(1rho)-encoded imaging, especially at low-burst pulse amplitudes (250 and 500 Hz).  相似文献   

19.
The changes of the regional cerebral blood volume (rCBV) with age were studied using dynamic susceptibility contrast MRI (DSC). We examined an unselected, random sample of 71 consecutive patients referred for work-up of suspected intracranial tumors (35 normal examinations, 36 tumors) with a standard 1.5 T clinical MR system. Determination of the rCBV was performed with a T21-weighted simultaneous dual (SD) FLASH sequence (TR/TE1/TE2/α = 32/25/16/10°, 55 images) after bolus injection of Gd-DTPA. Absolute quantification of the rCBV was achieved by normalizing the measured tissue concentration-time curves with the integrated arterial input function (AIF), which was simultaneously measured in the brain feeding arteries. The rCBV (mean ± SD) was 8.4 ± 2.9 ml/100 g and 4.2 ± 1.7 ml/100 g in gray and white matter, respectively, with a decline of about 3% and 6% per decade for white and gray matter, respectively. We conclude that DSC using a SD FLASH sequence allows the simultaneous measurement of the AIF and the tissue concentration-time curve and thus an absolute quantification of the rCBV, which is the basis for interperson comparisons and follow-up studies.  相似文献   

20.
In vivo diffusion characteristics of rat spinal cord.   总被引:2,自引:0,他引:2  
Complete apparent diffusion tensor (ADTs) of spinal cord was measured in vivo in nine rats at 2.0 T. Two rotationally invariant parameters, the trace, which is a measure of the mean diffusivity, and the lattice index (LI), which reflects the degree of orientation coherence of tissue, have been estimated from the ADT. The mean white matter (WM) trace value (3.05 +/- 0.26 mm2/sec) was found to be substantially higher than the gray matter (GM) trace (2.36 +/- 0.39 mm2/sec), in contrast with the published results on fixed, excised cord. Statistically significant anisotropic diffusion was observed in both WM and GM, with greater anisotropy in the WM (LI = 0.67 +/- 0.06) than in the GM (LI = 0.51 +/- 0.05).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号