首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A specific research and development program has been carried out by BARC in India to develop the technology for large area silicon strip detectors for application in nuclear and high energy physics experiments. These strip detectors will be used as pre-shower detector in the CMS experiment at LHC, CERN for π 0/λ rejection. The fabrication technology to produce silicon strip detectors with very good uniformity over a large area of ∼40 cm2, low leakage currents of the order of 10 nA/cm2 per strip and high breakdown voltage of >500 V has been developed by BARC. The production of detectors is already under way to deliver 1000 detector modules for the CMS and 90% production is completed. In this paper, research and development work carried out to develop the detector fabrication technology is briefly described. The performance of the silicon strip detectors produced in India is presented. The present status of the detector technology is discussed.   相似文献   

2.
Anode floating voltage is predicted and investigated for silicon drift detectors (SDDs) with an active area of 5 mm2 fabricated by a double-side parallel technology. It is demonstrated that the anode floating voltage increases with the increasing inner ring voltage, and is almost unchanged with the external ring voltage. The anode floating voltage will not be affected by the back electrode biased voltage until it reaches the full-depleted voltage (-50 V) of the SDD. Theoretical analysis and experimental results show that the anode floating voltage is equal to the sum of the inner ring voltage and the built-in potential between the p+ inner ring and the n+ anode. A fast checking method before detector encapsulation is proposed by employing the anode floating voltage along with checking the leakage current, potential distribution and drift properties.  相似文献   

3.
We have studied the response of CMOS compatible detectors fabricated in a silicon-on-sapphire (SOS) process, operated under short pulse excitation in the blue. These high speed, low capacitance detectors would be suitable for very precise, surface-normal clock injection with silicon CMOS. We characterize the capacitance of the detector structure through a combination of experimental techniques and circuit-level and electromagnetic simulations. The transit-time-limited response of the detectors is validated through pump–probe experiments. Detector response times of ∼35 ps have been measured, and devices have capacitance as low as ∼4 fF.  相似文献   

4.
In this paper we present the first experimental results obtained in the CASTOR tokamak by using a segmented biasing electrode, which is composed of five segments radially separated by 3 mm. The basic idea of choosing such configuration was to allow a spatial distribution of the biasing voltage in the radial direction. In the described experiments, one or more selected segments can be biased up to +300V, while the remaining segments can be either grounded or floating. Two rake probes measure the edge radial profiles of the floating potential and the ion saturation current at the top and low field side of the torus. A Gundestrup probe, located at the top of the torus, measures the parallel and perpendicular Mach numbers together with the local electron temperature and density. A clear and reproducible transition to a regime with improved particle confinement is routinely observed, if the electrode is inserted deep enough into the plasma (r/a ≈ 0.5) and if one or two segments are biased up to +250V (the remaining segments are floating). The steepening of the radial profiles of the plasma density and potential demonstrate the formation of a transport barrier just inside the last closed flux surface. Fast relaxations of the edge profiles, with a frequency of about 10 kHz or higher, are observed when the value of the average radial electric field within the barrier reaches values of about 20 kV/m and the density gradient increases up to a factor 3 with respect to the ohmic phase. A detailed analysis of the spatial-temporal behavior of these relaxations is presented. Presented at the Workshop “Electric Fields, Structures and Relaxation in Edge Plasmas”, Tarragona, Spain, July 3–4, 2005.  相似文献   

5.
The effect of the use of different electrode materials for edge-plasma biasing on plasma density and floating-potential profile modifications has been recently investigated on the CASTOR tokamak. Dependences of biasing current, edge plasma density and floating potential on biasing voltage have been measured. Induced relaxation events and fast (10–50) kHz oscillations are shown and surface changes of the biasing electrodes are discussed in the paper. Presented at the Workshop “Electric Fields, Structures and Relaxation in Edge Plasmas”, Tarragona, Spain, July 3–4, 2005.  相似文献   

6.
The fission track registration efficiency (K wet) of the Garware polyester track (GPF) detector in solution has been determined with respect to the Lexan detector whose K wet is very well known in the literature. The K wet is found to be (1.2 ± 0.1) 10−3 cm. The track registration efficiency of the GPF detector in solution is better than the efficiencies of other nuclear track detectors reported in the literature. This implies that the threshold energies for track registration are different for different detectors and that GPF detector has a lower threshold-energy value. The effects of gamma irradiation in the dose range of 5–51 Mrad on the fission track registration efficiency (K wet) of this track detector from the solution medium are also investigated. The results show that the K wet values for the gamma-irradiated detectors in the above dose range in 2M HNO3 solution medium decreases by ∼7–15%. The changes induced in the gamma-irradiated detectors as a function of gamma dose have also been studied by bulk-etch rate measurements.  相似文献   

7.
P Mukherjee 《Pramana》2001,57(1):5-9
Experimental studies of nuclear excitations have been an important subject from the earliest days when the institute was established. The construction of 4 MeV proton cyclotron was mainly aimed to achieve this goal. Early experiments in nuclear spectroscopy were done with radioactive nuclei with the help of beta and gamma ray spectrometers. Small NaI(Tl) detectors were used for gamma-gamma coincidence, angular correlation and life time measurements. The excited states nuclear magnetic moments were measured in perturbed gamma-gamma angular correlation experiments. A high transmission magnetic beta ray spectrometer was used to measure internal conversion coefficients and beta-gamma coincidence studies. A large number of significant contributions were made during 1950–59 using these facilities. Proton beam in the cyclotron was made available in the late 1950’s and together with 14 MeV neutrons obtained from a C-W generator a large number of short-lived nuclei were investigated during 1960’s and 1970’s. The introduction of high resolution Ge gamma detectors and the improved electronics helped to extend the spectroscopic work which include on-line (p 7 p′γ) and (p 7 ) reaction studies. Nuclear spectroscopic studies entered a new phase in the 1980’s with the availability of 40–80 MeV alpha beam from the variable energy cyclotron at VECC, Calcutta. A number of experimental groups were formed in the institute to study nuclear level schemes with (α 7 xnγ) reactions. Initially only two unsuppressed Ge detectors were used for coincidence studies. Later in 1989 five Ge detectors with a large six segmented NaI(Tl) multiplicitysum detector system were successfully used to select various channels in (α 7 xnγ) reactions. From 1990 to date a variety of medium energy heavy ions were made available from the BARC-TIFR Pelletron and the Nuclear Science Centre Pelletron. The state of the art gamma detector arrays in these centres enabled the Saha Institute groups to undertake more sophisticated experiments. Front line nuclear spectroscopy works are now being done and new informations are obtained for a large number of nuclei over a wide mass range. Currently Saha Institute is building a multi-element gamma heavy ion neutron array detector (MEGHNAD), which will have six high efficiency clover Ge detector together with charged particle ball and other accessories. The system is expected to be usable in 2002 and will be used in experiments using high energy heavy ions from VECC.  相似文献   

8.
为突破传统半导体核探测器耐高温与抗辐照性能不足的瓶颈,采用4H-SiC宽禁带半导体材料研制了4H-SiC探测器,并研究其构成的探测系统对α粒子的能量分辨率和能量线性度。所研制4H-SiC探测器漏电流低,当外加反向偏压为200V时,其漏电流仅14.92nA/cm2。采用具有5种主要能量α粒子的226 Ra源研究其构成的探测系统对α粒子的能量分辨率,获得4H-SiC探测系统对4.8~7.7 MeV能量范围内α粒子的能量分辨率为0.61%~0.90%,与国际上报道的高分辨4H-SiC探测系统能量分辨率一致。同时,实验结果表明:4H-SiC探测系统对该能量范围内α粒子的能量线性度十分优异,线性相关系数为0.999 99。  相似文献   

9.
The time recovery of the spectroscopic capabilities of CdZnTe and CdTe detectors, irradiated with increasing doses of high- and low-energy neutrons, as well as electrons, has been investigated by studying their spectroscopic behavior at different photon energies using leakage current measurements and PICTS (photo-induced current transient spectroscopy) analysis. The detectors were stored at room temperature for up to one year to study the time evolution of their spectroscopic performance and to correlate it with the presence of defective states in the material. We have observed a clear improvement in the material’s detection properties with time, though only in those detectors which have not been severely degraded by the irradiation. The recovery can be associated with a decrease in the concentration of some defective states, thus allowing the assessment of the crucial role these play in determining the charge collection processes in the material and its spectroscopic capabilities. Received: 1 August 2001 / Accepted: 3 August 2001 / Published online: 20 December 2001  相似文献   

10.
The feasibility of a storage element with inherent rectifying or isolation properties for use in passive memory arrays has been demonstrated using a programmable metallization cell structure with a doped (n-type) silicon electrode. The Cu/Cu–SiO2/n-Si cell used in this study switches via the formation of a nanoscale Cu filament in the Cu–SiO2 film which results in the creation of a Cu/n-Si Schottky contact with soft reverse breakdown characteristics. The reverse bias leakage current in the on-state diode is dependent on the programming current employed as this influences the area of the electrodeposit and hence the area of the Cu/n-Si junction. The programming current also controls the on-state resistance of the device, allowing multi-level cell (MLC) operation, in which discrete resistance levels are used to represent multiple logical bits in each physical cell. The Cu/Cu–SiO2/n-Si elements with heavily doped silicon electrodes were readily erasable at voltage less than −5 V which allows them to be re-programmed. Lightly doped silicon electrode devices were not able to be erased due to their very high reverse breakdown voltage but exhibited extremely low leakage current levels potentially allowing them to be used in low energy one-time programmable arrays.  相似文献   

11.
It is shown that the energy resolution of silicon detectors, estimated from α-ray spectra irradiated by a reference α source (i.e., the surface resolution), is not always an indicator of detector quality. The energy resolution found from the spectra of particles that penetrate deeply into the detector material (i.e., the depth resolution) can be quite inferior to the surface resolution. It is proposed that detectors be tested in a quasimochromatic neutron flux.  相似文献   

12.
The PHENIX detector at RHIC has been built with a strong heavy quark particles identification capability. These unique probes of matter are essential to adequately understand in-medium energy loss and to test the basic properties of QCD. The current PHENIX heavy flavor physics program will be significantly enhanced by the addition of the Forward Silicon Vertex upgrade detector (FVTX) in the acceptance of the existing muon arm detectors (1.2<|y|<2.4). The proposed tracker is planned to be put into operation in FY2011. Each arm of the FVTX detector consists of 4 disks of silicon strip sensors combined with FPHX readout chips and provides a precision measurement of the radial coordinate of the track. The current status of the detector design and construction and expectations for the physics signal extraction will be presented.  相似文献   

13.
If string theory is correct, then our observable Universe may be a 3-dimensional “brane” embedded in a higher-dimensional spacetime. This theoretical scenario should be tested via the state-of-the-art in gravitational experiments—the current and upcoming gravity-wave detectors. Indeed, the existence of extra dimensions leads to oscillations that leave a spectroscopic signature in the gravity-wave signal from black holes. The detectors that have been designed to confirm Einstein's prediction of gravity waves, can in principle also provide tests and constraints on string theory. Fourth Award in the 2005 Essay Competition of the Gravity Research Foundation. - Ed.  相似文献   

14.
Thin CdTe detectors (3×5 mm2 electrode area and 0.5 mm thick) mounted in a back-to-back configuration with a common anode, have been characterized. The goal was to determine the dimensions of the detector region offering good spectroscopic performance. The detector size was chosen on the basis of previous studies performed on various detectors which have shown that the width of this “best spectroscopy region” assumes a constant value of about 0.4 mm in the device thickness range 1.0–2.5 mm, while it is largely reduced when using a smaller electrode area (2×2 mm2) and 0.5 mm thick devices. The tests were performed by irradiating the detectors with a well collimated EX=122 keV photon beam. The results show that the edge effects observed in smaller detectors with the same configurations are significantly reduced, giving a better energy resolution, but not a wider region with good spectroscopic performance; at lower energies the effects of larger electrodes (increased electric capacitance and leakage current) result in a higher noise and an increased detection threshold.  相似文献   

15.
The work is dedicated to the discussion of four new types of large-area scintillation counters design intended for detection of EAS and the use in the guard systems of experimental physics setups with low-cost production. The solid counters based on scintillating polystyrene plates are produced by melting clear polystyrene granules with additives in a mirror mold. Other counters are based on lentil-like polystyrene scintillation granules which are a new kind of plastic scintillators produced at IHEP. WLS fibers and SiPM as a photo sensor are used for a light detection. The dimensions of the tested detectors were 500 × 500 and to 1000 × 1000 mm2, their measured light output was up to 180 ph.e.  相似文献   

16.
We have developed a prototype of a survey meter combining a CVD diamond detector and silicon detectors to appropriately take temporal measurements of γ-ray radiations over a wide range of the dose rates and to measure high accumulated doses of γ-ray radiations. In order to carry out this, at first, we have studied the radiation hardness of diamond detectors suitably fabricated with high-quality single-crystalline CVD diamond films to confirm that such CVD diamond detectors have greatly superior radiation hardness, compared with commercially available silicon detectors. It is evidenced that the performance of the CVD diamond detector did not significantly change even after heavy γ-ray irradiation of 0.7 MGy while the silicon detectors have a remarkable increase in the dark current, a detection peak shift to the low energy side, and a decrease in detection counts for 5.486-MeV α particles. Due to a size limitation of the CVD diamond detector, such a CVD diamond detector was combined with six commercially available silicon detectors to fabricate a survey meter which can appropriately work under severe irradiation conditions, or, at accumulated doses larger than at least 0.5 MGy and which can cover a wide range of the dose rates from 1 μGy/h to at least 1 kGy/h. The prototype survey meter had a practically useful linearity in this dose rate range. Thus, we have confirmed that such a diamond-Si combined survey meter can be put into practical use.  相似文献   

17.
At present, uncooled thermal detector focal plane arrays are successfully used in staring thermal imagers. However, the performance of thermal detectors is modest, they suffer from slow response and they are not very useful in applications requiring multispectral detection. Infrared (IR) photon detectors are typically operated at cryogenic temperatures to decrease the noise of the detector arising from various mechanisms associated with the narrow band gap. There are considerable efforts to decrease system cost, size, weight, and power consumption to increase the operating temperature in so-called high-operating-temperature (HOT) detectors. Initial efforts were concentrated on photoconductors and photoelectromagnetic detectors. Next, several ways to achieve HOT detector operation have been elaborated including non-equilibrium detector design with Auger suppression and optical immersion. Recently, a new strategies used to achieve HOT detectors include barrier structures such as nBn, material improvement to lower generation-recombination leakage mechanisms, alternate materials such as superlattices and cascade infrared devices. Another method to reduce detector’s dark current is reducing volume of detector material via a concept of photon trapping detector. In this paper, a number of concepts to improve performance of photon detectors operating at near room temperature are presented. Mostly three types of detector materials are considered — HgCdTe and InAsSb ternary alloys, and type-II InAs/GaSb superlattice. Recently, advanced heterojunction photovoltaic detectors have been developed. Novel HOT detector designs, so called interband cascade infrared detectors, have emerged as competitors of HgCdTe photodetectors.  相似文献   

18.
We fabricated a high-performance polycrystalline silicon (poly-Si) thin film transistor (TFT) by new excimer laser annealing (ELA) method employing floating active structure. The new simple ELA method produces large lateral grains exceeding 4 μm. A novel poly-Si TFT that exhibits very high mobility (μFE=331 cm2/V s) and low leakage current has been successfully fabricated by single laser irradiation on selectively floating a-Si layer. Uniform lateral grains have been obtained with wide ELA process window.  相似文献   

19.
In the detectors currently being developed for experiments on the next-generation lepton colliders, highly granular calorimeters are to be used. In particular, the hadron calorimeter is planned to be assembled from scintillation cells with direct readout of light by silicon photomultipliers. According to the results of experimental measurements of the light collection in a cell developed for the CALICE prototype hadron calorimeter, when detecting minimum ionizing particles, an estimate of the detector effects was obtained. The detector effect on the resolution of the ILD hadron calorimeter was studied by modeling the response of the detector to single neutral kaons. It was shown that the contribution of experimentally measured detector effects to the resolution for single particles is on the order of 0.5–1% in the range of hadron energy of 5–60 GeV.  相似文献   

20.
The work describes multiband photon detectors based on semiconductor micro-and nano-structures. The devices considered include quantum dot, homojunction, and heterojunction structures. In the quantum dot structures, transitions are from one state to another, while free carrier absorption and internal photoemission play the dominant role in homo or heterojunction detectors. Quantum dots-in-a-well (DWELL) detectors can tailor the response wavelength by varying the size of the well. A tunnelling quantum dot infrared photodetector (T-QDIP) could operate at room temperature by blocking the dark current except in the case of resonance. Photoexcited carriers are selectively collected from InGaAs quantum dots by resonant tunnelling, while the dark current is blocked by AlGaAs/InGaAs tunnelling barriers placed in the structure. A two-colour infrared detector with photoresponse peaks at ∼6 and ∼17 μm at room temperature will be discussed. A homojunction or heterojunction interfacial workfunction internal photoemission (HIWIP or HEIWIP) infrared detector, formed by a doped emitter layer, and an intrinsic layer acting as the barrier followed by another highly doped contact layer, can detect near infrared (NIR) photons due to interband transitions and mid/far infrared (MIR/FIR) radiation due to intraband transitions. The threshold wavelength of the interband response depends on the band gap of the barrier material, and the MIR/FIR response due to intraband transitions can be tailored by adjusting the band offset between the emitter and the barrier. GaAs/AlGaAs will provide NIR and MIR/FIR dual band response, and with GaN/AlGaN structures the detection capability can be extended into the ultraviolet region. These detectors are useful in numerous applications such as environmental monitoring, medical diagnosis, battlefield-imaging, space astronomy applications, mine detection, and remote-sensing. The paper presented there appears in Infrared Photoelectronics, edited by Antoni Rogalski, Eustace L. Dereniak, Fiodor F. Sizov, Proc. SPIE Vol. 5957, 59570W (2005).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号