首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Yoo C  Pal M  Miller FR  Barder TJ  Huber C  Lubman DM 《Electrophoresis》2006,27(11):2126-2138
A method is developed toward high sequence coverage of proteins isolated from human breast cancer MCF10 cell lines using a 2-D liquid separations. Monolithic-capillary columns prepared by copolymerizing styrene with divinylbenzene are used to achieve high-resolution separation of peptides from protein digests. This separation is performed with minimal sample preparation directly from the 2-D liquid fractionation of the cell lysate. The monolithic column separation is directly interfaced to ESI-TOF MS to obtain a peptide map. The protein digests were also analyzed by MALDI-TOF MS and an accurate M(r) of the intact protein was obtained using an HPLC-ESI-TOF MS. The result is that these techniques provide complementary information where nearly complete sequence coverage of the protein is obtained and can be compared to the experimental M(r) value. The high sequence coverage provides information on isoforms and other post-translational modifications that would not be available from methods that result in low sequence coverage. The results from the use of monolithic columns are compared to that obtained by CE-MS. The monolithic column separations provide a rugged and highly reproducible method for separating protein digests prior to MS analysis and is suited to confidently identify biomarkers associated with cancer progression.  相似文献   

2.
A molecular weight map of the protein content of ES2 human clear cell ovarian carcinoma cells has been produced using a two-dimensional (2-D) liquid separations/mass mapping technique. This method uses a 2-D liquid separation of proteins from whole cell lysates coupled on-line to an electrospray ionization-time of flight (ESI-TOF) mass spectrometer to map the accurate intact molecular weight (M(r)) of the protein content of the cells. The two separation dimensions involve the use of liquid isoelectric focusing as the first phase and nonporous silica reversed-phase high-performance liquid chromatography (HPLC) as the second phase of separation. The detection by ESI-TOF-MS provides an image of pI versus M(r) analogous to 2-D gel electrophoresis. Each protein is then identified based upon matrix-assisted laser desorption/ionization (MALDI)-TOF-MS peptide mapping and intact M(r) so that a standard map is produced against which other ovarian carcinoma cell lines can be compared. The accurate intact M(r) together with the pI fraction, and peptide map serve to tag the protein for future interlysate comparisons. An internal standard is also used to provide a means for quantitation for future interlysate studies. In the ES2 cell line under study it is shown that nearly 900 M(r) bands are detected over 17 pI fractions from pH 4 to 12 and a M(r) range up to 85 kDa and that around 290 of these bands can be identified using mass spectrometric based techniques. The protein M(r) is detected within an accuracy of 150 ppm and it is shown that many of the proteins in this human cancer sample are modified compared to the database. The protein M(r) map may serve as a highly reproducible standard Web-based method for comparing proteins from related human cell lines.  相似文献   

3.
Erny GL  Marina ML  Cifuentes A 《Electrophoresis》2007,28(17):2988-2997
Zein proteins are a complex mixture of polypetides that belong to the alcohol-soluble storage proteins group (prolamines) in corn. These proteins constitute about 50-60% of the total endosperm protein and are classified in different groups on the basis of differences in their solubility and sequence. Among them, zein proteins are considered the majority group showing a high tendency to aggregate what makes their analysis by any analytical method very difficult. Thus, CZE of these proteins requires the use of very complex BGEs noncompatible with online ESI-MS analysis. The aim of this work was to find a new BGE for the CZE separation of zein protein fully compatible with ESI-MS while providing further light on the complex CZE separation of aggregatable proteins. Thus, it is demonstrated in this work that efficient and reproducible CZE separations of zein proteins can be achieved by using a BGE composed of water, ACN, formic acid and ammonium hydroxide. Besides, it is shown that zein analysis is significantly improved by including the effect of an ammonium gradient during their separation. It is experimentally verified that the ammonium gradient can easily be achieved in CZE by either working with a sample zone with a low concentration of ammonium and a BGE with a high concentration, or conversely, working with a sample zone with high ammonium concentration and a BGE with low concentration of ammonium, giving rise in both cases to a significant improvement in the CZE separation of these proteins. It is demonstrated that this procedure can give rise to efficiency improvements of up to 20-fold in the CZE separation of zein proteins. Under optimized conditions, 20 proteins could be separated with average efficiencies higher than 400 000 theoretical plates/m. Some possible explanations of this effect are discussed including stacking, protein-capillary wall adsorption, protein solubility and protein-salt interactions.  相似文献   

4.
In this work, two different CE-MS instruments, namely, CE-ESI-IT-MS and CE-ESI-TOF-MS, applied to analyse intact proteins from complex samples are investigated. The aim of this work was to compare both instruments in terms of LOD, number of proteins detected, and precision and repeatability in the determination of the protein relative molecular mass. Results show that although CE-ESI-IT-MS provides cleaner MS spectra of intact proteins, CE-ESI-TOF-MS allows the identification of a higher number of proteins from complex matrices in an easier way. Performance in terms of peak area reproducibility, LOD and precision in the determination of the molecular mass were similar for both instruments. The usefulness of the optimised CE-ESI-IT-MS and CE-ESI-TOF-MS conditions was demonstrated by studying the zein-proteins composition of three natural maize lines and their corresponding transgenic lines, showing no significant differences.  相似文献   

5.
In this work, capillary electrophoresis was applied to protein profiling of fractionated extracts of maize. A comparative study on the application of uncoated fused‐silica capillaries and capillaries modified with hydroxypropylmethylcellulose, ω‐iodoalkylammonium salt and a commercially available neutral capillary covalently coated with polyacrylamide is presented. The coating stability, background electrolyte composition, and separation efficiency were investigated. It was found that for zeins separation, the most stable and efficient was the capillary coated with polyacrylamide. Finally, the usefulness of these methods was studied for the differentiation of zein fraction in transgenic and nontransgenic maize. Zeins extracted from maize standards containing 0 and 5% m/m genetic modification were successfully separated, but slight differences were observed in terms of the zein content. Albumin and globulin fractions were analyzed with the use of unmodified fused‐silica capillary with borate buffer pH 9 and the capillary coated with polyacrylamide with phosphate buffer pH 3. In the albumin fraction, additional peaks were found in genetically modified samples.  相似文献   

6.
Online coupling of capillary electrophoresis (CE) to electrospray ionization mass spectrometry (MS) has shown considerable potential, however, technical challenges have limited its use. In this study, we have developed a simple and sensitive sheathless CE-MS interface based on the novel concept of forming a sub-micrometer fracture directly in the capillary. The simple interface design allowed the generation of a stable ESI spray capable of ionization at low nanoliter flow-rates (45–90 nL/min) for high sensitivity MS analysis of challenging samples like those containing proteins and peptides. By analysis of a model peptide (leucine enkephalin), a limit of detection (LOD) of 0.045 pmol/μL (corresponding to 67 attomol in a sample volume of ∼15 nL) was obtained. The merit of the CE-MS approach was demonstrated by analysis of bovine serum albumin (BSA) tryptic peptides. A well-resolved separation profile was achieved and comparable sequence coverage was obtained by the CE-MS method (73%) compared to a representative UPLC-MS method (77%). The CE-MS interface was subsequently used to analyse a more complex sample of pharmaceutically relevant human proteins including insulin, tissue factor and α-synuclein. Efficient separation and protein ESI mass spectra of adequate quality could be achieved using only a small amount of sample (30 fmol). In addition, analysis of ubiquitin samples under both native and denatured conditions, indicate that the CE-MS setup can facilitate native MS applications to probe the conformational properties of proteins. Thus, the described CE-MS setup should be useful for a wide range of high-sensitivity applications in protein research.  相似文献   

7.
梁玉  张丽华  张玉奎 《色谱》2020,38(10):1117-1124
蛋白质组学研究在生物学、精准医学等方面发挥着重要的作用。然而研究面临的巨大挑战来自生物样品的复杂性,因此在质谱(MS)鉴定技术不断革新的同时,发展分离技术以降低样品复杂度尤为重要。毛细管电泳(CE)技术具有上样体积小、分离效率高、分离速度快等优势,其与质谱的联用在蛋白质组学研究中越来越受到关注。低流速鞘流液和无鞘流液接口的发展及商品化推动了CE-MS技术的发展。目前毛细管区带电泳(CZE)、毛细管等电聚焦(CIEF)、毛细管电色谱(CEC)等分离模式已与质谱联用,其中CZE-MS应用最广泛。目前被广泛采用的蛋白质组学研究策略主要是基于酶解肽段分离鉴定的"自下而上(bottom-up)"策略。首先,CE-MS技术对酶解肽段的检测灵敏度高达1 zmol,已成功应用于单细胞蛋白质组学;其次,毛细管电泳技术与反相液相色谱互补,为疏水性质相近的肽段(尤其是翻译后修饰肽段)的分离鉴定提供了新的途径。基于整体蛋白质分离鉴定的自上而下"top-down"策略可以直接获得更精准、更完整的蛋白质信息。CE技术在蛋白质大分子的分离方面具有分离效率高、回收率高的优势,其与质谱的联用提高了整体蛋白质的鉴定灵敏度和覆盖度。非变性质谱(native MS)是一种在近生理条件下从完整蛋白质复合物水平上进行分析的质谱技术。CE与非变性质谱联用已被尝试用于蛋白质复合体的分离鉴定。该文引用了与CE-MS和蛋白质组学应用相关的93篇文献,综述了以上介绍的CE-MS的研究进展以及在蛋白质组学分析中的应用优势,并总结和展望了其应用前景。  相似文献   

8.
In this work, a new capillary electrophoresis-mass spectrometry (CE-MS) procedure is developed to analyze proteins in Spirulina platensis microalgae. It is demonstrated that a fine optimization of several separation parameters is essential in order to achieve suitable CE-MS analysis of these proteins in natural extracts from microalgae. Namely, optimization of the composition of the separation buffer, electrospray conditions, and washing routine between runs are required in order to obtain reliable and reproducible CE-MS analyses of the main proteins found in this microalga (namely, allophycocyanin-alpha chain, allophycocyanin-beta, c-phycocyanin-alpha, and c-phycocyanin-beta). The relative molecular mass of these biopolymers is determined using two different MS instruments coupled to CE, i.e., CE-ion trap-MS and CE-time of flight-MS (CE-TOF-MS). A comparison between the results obtained with both instruments is carried out. The high resolution of the TOF-MS enables the distinction of small modifications in proteins and, thus, a more accurate mass determination. Interestingly, molecular mass values obtained by both CE-MS procedures agree very well while these experimental values are only in partial agreement with those theoretically expected (i.e., genetically derived masses). Some protein modifications due to amino acids exchange induced by nucleotide codon mutations are proposed to explain this difference.  相似文献   

9.
The proteins of the zein complex from maize endosperm have been studied with the aid of hydrophobic chromatography. Their best separation was achieved on a column with TSK gel HW-65f. By comparing the results of fractionation by hydrophobic chromatography with those of electrophoresis, it was found that electrophoresis in PAAG under denaturing conditions separates the zein protein into groups according to their surface hydrophobicity. The most hydrophobic is the high-molecular-mass group of zein polypeptides.V. R. Vil'yams Kazakh Scientific-Research Agricultural Institute, Alma-Ata Province. Translated from Khimiya Prirodnykh Soedinenii, No. 1, pp. 105–108, January–February, 1991.  相似文献   

10.
Two important limitations still exist for the characterization of protein digests by capillary electrophoresis-mass spectrometry (CE-MS): (i) the buffer choice (i.e., the buffer must provide an adequate CE separation without ruining the MS signal), and (ii) the frequent generation of "unexpected" peptidic fragments during the enzymatic protein hydrolysis. In this work, a new approach is used to solve these difficulties, namely a theoretical model that relates the electrophoretic behavior of peptides to their sequence. The effectiveness of this procedure is demonstrated by the fast attainment of good CE-MS conditions for analyzing the peptides obtained from an enzymatic protein hydrolysate in a single run. This strategy can provide useful information for helping to characterize "unexpected" fragments from protein digests.  相似文献   

11.
In this report, we present the use of CE-MS as complement to RP separation for the identification of novel angiotensin-converting enzyme-inhibitory (ACEI) peptides from a complex milk protein hydrolysate. As preliminary step, fast protein LC (FPLC) was used to isolate the different casein fractions from raw ovine milk. Enzymatic hydrolysis of these fractions was performed by using proteolytic enzymes of gastrointestinal origin. The most active hydrolysate, corresponding to kappa-casein hydrolyzed with pepsin, chymotrypsin, and trypsin, was fractionated by RP-HPLC and the peptides contained in the active fractions were sequenced by CE coupled to IT-MS (CE-MS). The use of CE-MS allowed the identification of short peptides with ACEI activity included in the scarcely retained fraction obtained by semipreparative RP-HPLC. Among the identified peptides, those with hydrophobic or positively charged residues at the C-terminal tripeptide were chemically synthesized to determine their ACEI activity. This procedure allowed us to identify four novel potent ACEI peptides from kappa-casein with sequences IAK, YQQRPVA, WQVLPNAVPAK, and HPHPHLSF. These active sequences could be obtained by enzymatic hydrolysis either of the individual kappa-casein fraction or the total casein fraction from ovine milk.  相似文献   

12.
Catharanthus roseus is an important dicotyledonous medicinal plant that contains various anticancer components, such as vinblastine (VLB) and its monomeric precursors (vindoline and catharanthine). A capillary electrophoresis-mass spectrometry (CE-MS) approach for the simultaneous determination of three components was developed in this work. Baseline separation for three components was achieved by using a running buffer consisting of 20 mM ammonium acetate and 1.5% acetic acid in <20 min. Quantification of three components was assigned in positive-ion mode at a protonated molecular ion [M+H](+). The CE-MS method was validated for linearity, sensitivity, accuracy and precision, and then used to determine the content of the above components. The detection limits of VLB, catharanthine and vindoline are 0.8, 0.1 and 0.1 μg/mL, respectively. The precision was not more than 4.54% and the mean recovery of the analytes was 95.04-97.04%. The CE-MS method was successfully applied to determine VLB and its monomeric precursors in real sample C. roseus.  相似文献   

13.
CE coupled to MS has proven to be a powerful analytical tool for the characterization of intact proteins, as it combines the high separation efficiency of CE with the selectivity of MS. This review provides an overview of the development and application of CE-MS methods within the field of intact protein analysis as published between January 2007 and June 2010. Ongoing technological developments with respect to CE-MS interfacing, capillary coatings for CE-MS, coupling of CIEF with MS and chip-based CE-MS are treated. Furthermore, CE-MS of intact proteins involving ESI, MALDI and ICP ionization is outlined and overviews of the use of the various CE-MS methods are provided by tables. Representative examples illustrate the applicability of CE-MS for the characterization of proteins, including glycoproteins, biopharmaceuticals, protein-ligand complexes, biomarkers and dietary proteins. It is concluded that CE-MS is a valuable technique with high potential for intact protein analysis, providing useful information on protein identity and purity, including modifications and degradation products.  相似文献   

14.
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied. Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source. Using a BGE of 100 mM acetic acid (pH 3.1) and a positively charged capillary coating, a highly reproducible and efficient separation of four model proteins (insulin, carbonic anhydrase II, ribonuclease A and lysozyme) was obtained. The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities. Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses. However, as noise levels increased with sheath-liquid CE-MS, detection limits were improved by a factor 6.5-20 with sheathless CE-MS. The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BGE, leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins. Clearly, the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins.  相似文献   

15.
The potential of capillary electrophoresis (CE) for the separation of peptides has been extensively demonstrated in the last decade. Their correct characterization and sequenciation is a difficult task that can be accomplished using CE-mass spectrometry (CE-MS). An important limitation of CE-MS is the buffer choice since it should provide an adequate CE separation without ruining the MS signal. In this work, a new strategy is used to help to solve this limitation based on the combination of two different methodologies. Namely, an ab initio semiempirical model that relates electrophoretic behavior of peptides to their sequence is first used to obtain in a fast and easy way adequate CE buffers compatible with MS analysis. Next, CE-MS is used to separate and characterize peptides via the determination of their relative molecular masses. The usefulness of this procedure is demonstrated analyzing in a single CE-MS run a group of 10 standard peptides of very different nature (i.e., relative molecular masses ranging from 132 to 1037 and isoelectric points ranging from 5.69 to 10.62). It is concluded that the use of this strategy can help to overcome the buffer limitation in CE-MS.  相似文献   

16.
Moini M  Huang H 《Electrophoresis》2004,25(13):1981-1987
We introduce capillary electrophoresis-mass spectrometry (CE-MS) as an efficient means for the on-line separation and identification of protein mixtures. It was found that while CE/electrospray ionization (ESI)-MS analysis of whole-cell lysate was too complicated for the one-dimensional CE-MS analysis, the technique was useful for the analysis of protein mixtures of moderate complexity (approximately 50 intact proteins). CE/ESI-MS was applied to the subcellular proteomics of ribosomal Escherichia coli. 55 out of the 56 ribosomal proteins were detected with ease by using only approximately 3.4 ng of ribosomal proteins. In addition, it was found that the mass accuracy of the conventional MS (such as quadrupole ion traps) was good enough to identify many post-translational modifications of the intact proteins by simply comparing their measured average molecular weight with the average molecular weight predicted from gene banks.  相似文献   

17.
Proteins with molecular mass (M(r)) <20 kDa are often poorly separated in 2-D sodium dodecyl sulfate polyacrylamide gel electrophoresis. In addition, low-M(r) proteins may not be readily identified using peptide mass fingerprinting (PMF) owing to the small number of peptides generated in tryptic digestion. In this work, we used a 2-D liquid separation method based on chromatofocusing and non-porous silica reversed-phase high-performance liquid chromatography to purify proteins for matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis and protein identification. Several proteins were identified using the PMF method where the result was supported using an accurate M(r) value obtained from electrospray ionization TOFMS. However, many proteins were not identified owing to an insufficient number of peptides observed in the MALDI-TOF experiments. The small number of peptides detected in MALDI-TOFMS can result from internal fragmentation, the few arginines in its sequence and incomplete tryptic digestion. MALDI-QTOFMS/MS can be used to identify many of these proteins. The accurate experimental M(r) and pI confirm identification and aid in identifying post-translational modifications such as truncations and acetylations. In some cases, high-quality MS/MS data obtained from the MALDI-QTOF spectrometer overcome preferential cleavages and result in protein identification.  相似文献   

18.
A new physically adsorbed capillary coating for capillary electrophoresis-mass spectrometry (CE-MS) of basic proteins is presented, which is easily obtained by flushing the capillary with a polymer aqueous solution for two min. This coating significantly reduces the electrostatic adsorption of a group of basic proteins (i.e., cytochrome c, lysozyme, and ribonuclease A) onto the capillary wall allowing their analysis by CE-MS. The coating protocol is compatible with electrospray inonization (ESI)-MS via the reproducible separation of the standard basic proteins (%RSD values (n = 5) < 1% for analysis time reproducibility and < 5% for peak heights, measured from the total ion electropherograms (TIEs) within the same day). The LODs determined using cytochrome c with total ion current and extracted ion current defection were 24.5 and 2.9 fmol, respectively. Using this new coating lysozymes from chicken and turkey egg white could be easily distinguished by CE-MS, demonstrating the usefulness of this method to differentiate animal species. Even after sterilization at 120 degrees C for 30 min, lysozyme could be detected, as well as in wines at concentrations much lower than the limit marked by the EC Commission Regulation. Adulteration of minced meat with 5% of egg-white could also be analysed by our CE-MS protocol.  相似文献   

19.
Taichrib A  Pioch M  Neusüss C 《Electrophoresis》2012,33(9-10):1356-1366
Capillary electrophoresis-mass spectrometry (CE-MS) more and more gains in importance as an analytical technique for the identification and characterization of intact proteins in the biopharmaceutical area. Thus, a CE-ESI-MS method was optimized and validated systematically with respect to the improved screening and characterization of intact proteins. The optimization was accomplished by variation of different CE-MS parameters, such as capillary coating, background electrolyte, sheath liquid, and nebulizer gas pressure, while monitoring both the resolution and signal intensities. Achievable separation is discussed quantitatively in the context of the coating and the resulting EOF, the protein mobilities, and the suction effect of the sprayer. The observed precisions of the optimized method regarding the migration times (mean RSD = 1.4%) and peak areas (mean RSD = 12.3%) and an extensive principal component analysis revealed that the presented method is reliable and useful for the quantitation of intact proteins and protein isoforms. The applicability of this method to various proteins showing different characteristics (pI value, molecular mass, hydrophobicity, etc.) is discussed. The presented method will contribute to the improved characterization of a large variety of intact proteins in the biomedical and pharmaceutical area.  相似文献   

20.
Proteomic approaches including high-resolution 2-DE are providing the tools needed to discover disease-associated biomarkers in complex biological samples. Although 2-DE is an extremely powerful approach to analyze the proteome, the separation of proteins with extreme molecular masses still remains an issue requiring improvement. Because high molecular mass (HMM) proteins larger than 150 kDa have already been observed to be differentially expressed in several pathologies such as cancer, we developed an original strategy to analyze this part of the proteome that is not easily separated by 2-DE in polyacrylamide gels. This strategy is based on the 2-DE separation of cyanogen bromide (CNBr) fragments of purified HMM protein fractions, and combines techniques including SEC fractionation, TCA precipitation, CNBr cleavage, 2-DE and MS analysis. The method was first tested on a model protein, the BSA. Preliminary results obtained using colonic tissues led to the identification of six HMM proteins with M(r) comprised between 163 and 533 kDa in their reduced state. These results demonstrated that our CNBr/2-DE approach should provide a powerful tool for identification of new biomarkers larger than 150 kDa.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号