首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.  相似文献   

2.
A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for 35Cl+ to more than 6 × 105 cps for 238U+ for 1 μg of trace element per gram of coal sample. Detection limits vary from 450 ng g−1 for chlorine and 18 ng g−1 for sulfur to 9.5 pg g−1 for mercury and 0.3 pg g−1 for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis. Figure LA-ICP-IDMS allows direct multi-element determination in powdered coal samples  相似文献   

3.
A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor of 16.5 with on-line standard addition, and (103)Rh was used as internal standard to compensate for signal fluctuation. The procedure was validated by the analysis of two standard reference materials SRM 2670 (NIST) and Seronormtrade mark Trace Elements in Urine. Recovery experiments were performed by spiking the reference materials as well as artificial urine. The detection limits (mug l(-1)) were 0.12,0.96,0.30,0.09,0.45,0.08,0.09, and the precisions (RSD,%) were 2.6,2.3,3.0,3.7,3.7,4.9,2.8 for Cu, Zn, As, Pb, Se, Ni and Mo, respectively. The procedure was applied to the analysis of 41 human urine samples. No correlations between the concentrations of the elements were observed.  相似文献   

4.
The potential effect of spectral interference on the accurate measurement of the cadmium (Cd) mass fraction in fortified breakfast cereal and a variety of dietary supplement materials using inductively coupled plasma quadrupole mass spectrometry was studied. The materials were two new standard reference materials (SRMs)—SRM 3233 Fortified Breakfast Cereal and SRM 3532 Calcium Dietary Supplement—as well as several existing materials—SRM 3258 Bitter Orange Fruit, SRM 3259 Bitter Orange Extract, SRM 3260 Bitter Orange-containing Solid Oral Dosage Form, and SRM 3280 Multivitamin/Multielement Tablets. Samples were prepared for analysis using the method of isotope dilution and measured using various operating and sample introduction configurations including standard mode, collision cell with kinetic energy discrimination mode, and standard mode with sample introduction via a desolvating nebulizer system. Three isotope pairs, 112Cd/111Cd, 113Cd/111Cd, and 114Cd/111Cd, were measured. Cadmium mass fraction results for the unseparated samples of each material, measured using the three instrument configurations and isotope pairs, were compared to the results obtained after the matrix was removed via chemical separation using anion exchange chromatography. In four of the six materials studied, measurements using the standard mode with sample introduction via the desolvating nebulizer gave results for the unseparated samples quantified with the 112Cd/111Cd isotope pair that showed a positive bias relative to the matrix-separated samples, which indicated a persistent inference at m/z?112 with this configuration. Use of the standard mode, without the desolvating nebulizer, also gave results that showed a positive bias for the unseparated samples quantified with the 112Cd/111Cd isotope pair in three of the materials studied. Collision cell/kinetic energy discrimination mode, however, was very effective for reducing spectral interference for Cd in all of the materials and isotope pairs studied, except in the multivitamin/multielement matrix (SRM 3280) where the large corrections for known isobaric interferences or unidentified interferences compromised the accuracy. For SRM 3280, matrix separation provided the best method to achieve accurate measurement of Cd.  相似文献   

5.
Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) was applied to the certification of Pb in four levels of NIST blood SRM, 955a. This standard reference material (SRM) represents a significant improvement over the previous blood reference material and will greatly aid method development. The lowest level, 47.76 ng/g Pb was determined with analysis uncertainty (95% CI, ID-ICP-MS uncertainties) of less than 1% and the highest level, 517.9 ng/g Pb to 0.3%. Uncertainty in the lowest level was due to sample inhomogeneity and variability in the analytical blank as the RSD on ratio measurements was typically better than 0.2%. Properly applied isotope dilution coupled with careful isotope ratio measurements on the ICP-MS offers precision and accuracy for blood Pb analyses beyond what is currently obtainable with routine methods.  相似文献   

6.
Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USS-ETV-ID-ICP-MS) has been applied to the determination of Cd, Hg and Pb in coal fly ash samples. Thioacetamide (TAC) was used as the modifier. Since the sensitivities of the elements studied in coal fly ash slurry and aqueous solution were quite different, isotope dilution method was used for the determination of Cd, Hg and Pb in these coal fly ash samples. The isotope ratios of each element were calculated from the peak areas of each injection peak. This method has been applied to the determination of Cd, Hg and Pb in NIST SRM 1633a coal fly ash reference material and a coal fly ash sample collected from Kaohsiung area. Analysis results of reference sample NIST SRM 1633a coal fly ash agreed satisfactorily with the certified values. The other sample determined by isotope dilution and method of standard additions was agreed satisfactorily. Precision was better than 6% for most of the determinations and accuracy was better than 4% with the USS-ETV-ID-ICP-MS method. Detection limits estimated from standard addition curves were in the range of 24–58, 6–28 and 108–110 ng g−1 for Cd, Hg and Pb, respectively.  相似文献   

7.
Polybrominated diphenyl ethers (PBDEs) have been measured for the first time in three different indoor dust Standard Reference Materials (SRMs) prepared by the National Institute of Standards and Technology (NIST). Two of these, SRM 2583 (Trace Elements in Indoor Dust) and SRM 2584 (Trace Elements in Indoor Dust), have been certified previously for lead and other inorganic constituents. A third, SRM 2585 (Organics in Indoor Dust), is a new indoor dust reference material prepared by NIST which will be certified for various organic compounds (polycyclic aromatic hydrocarbons, pesticides and polychlorinated biphenyls) in 2005 including certified concentrations for 16 individual PBDE congeners and reference values for an additional three PBDE congeners. Dust SRMs were analyzed for 30 PBDE congeners using high-resolution gas chromatography combined with low-resolution mass spectrometry operated in both negative chemical ionization (GC/ECNI–MS) and electron impact ionization (GC/EI–MS) modes. Sensitivity was an order of magnitude higher using GC/ECNI–MS relative to GC/EI–MS. These SRMs have been characterized and compared to the three PBDE commercial products (pentaBDE, octaBDE and decaBDE). PentaBDE and DecaBDE were present in all three SRMs and were the dominant commercial products, making up approximately 33% and 58%, respectively. Recent studies suggest that house dust may be a leading source of human exposure to PBDEs. These SRMs are the first reference materials with certified concentrations for PBDEs, which will aid in validating future measurements of PBDEs in house dust and other similar matrices. Electronic Supplementary Material Supplementary material is available for this article at http://dx.doi.org/ 10.1007/s00216-005-0227-y  相似文献   

8.
Standard reference material (SRM) 2584 (Trace Elements in Indoor Dust) was developed as a reference standard for evaluating field methods and for validating laboratory and reference methods for the assessment of lead contamination and exposure. In addition to lead, the toxic trace elements As, Cd, Cr, and Hg, at approximately 17, 10, 140, and 5 μg g–1, respectively, have been certified in the SRM. These four analytes were successfully determined by use of high-resolution inductively coupled plasma mass spectrometry (HR-ICP–MS). Isobaric interferences at masses of As and Cr were resolved by using the high resolution mode (nominal 8000) and the medium resolution mode (nominal 3000), respectively, of the instrument. The effects of a significant drift in analyte sensitivity in the course of measurement were rectified by use of internal standardization, single spike standard addition, and an optimized analysis sequence. The results were compared with those obtained by instrumental neutron activation analysis (INAA) and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP–MS). The results for the quality control, SRM 2704 (Buffalo River Sediment), were in good agreement with the certified values, indicated by the uncertainty intervals of the measured values overlapping the certified intervals at 95% confidence level.  相似文献   

9.
Standard reference material (SRM) 2584 (Trace Elements in Indoor Dust) was developed as a reference standard for evaluating field methods and for validating laboratory and reference methods for the assessment of lead contamination and exposure. In addition to lead, the toxic trace elements As, Cd, Cr, and Hg, at approximately 17, 10, 140, and 5 microg g(-1), respectively, have been certified in the SRM. These four analytes were successfully determined by use of high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Isobaric interferences at masses of As and Cr were resolved by using the high resolution mode (nominal 8000) and the medium resolution mode (nominal 3000), respectively, of the instrument. The effects of a significant drift in analyte sensitivity in the course of measurement were rectified by use of internal standardization, single spike standard addition, and an optimized analysis sequence. The results were compared with those obtained by instrumental neutron activation analysis (INAA) and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS). The results for the quality control, SRM 2704 (Buffalo River Sediment), were in good agreement with the certified values, indicated by the uncertainty intervals of the measured values overlapping the certified intervals at 95% confidence level.  相似文献   

10.
A microwave digestion method in a closed vessel was developed for the determination of trace metals in atmospheric aerosols using inductively coupled plasma mass spectrometry (ICP-MS). A recovery study for the elements V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Cd, Sb, and Pb was conducted using multi-elemental standard solutions, NIST 1633b Trace Elements in Coal Fly Ash, and NIST 1648 Urban Particulate Matter. A simple digestion method using only HNO3/H2O2 gave good recoveries (90%-108%) for all elements except Cr in SRM 1648, but yielded low recoveries for SRM 1633b. A more robust method using HNO3/H2O2/HF/H3BO3 yielded higher recoveries (82%-103%) for the lighter elements (V-Zn) in SRM 1633b, and improved the Cr recovery in SRM 1648, but decreased the Se recovery in both SRMs. A comparative analysis of aerosol samples obtained at a remote mountain location Nathiagali, Pakistan (2.5 km above mean sea level), and Mayville, New York, downwind from the highly industrialized Midwestern United States, was carried out using Instrumental Neutron Activation Analysis (INAA) for the elements Cr, Mn, Fe, Co, Zn, As, Se, and Sb. The simple digestion method yielded excellent agreement for Cr, Fe, Zn, As, Se, and Sb, with slopes of the ICP-MS vs. INAA regressions of 0.90-1.00 and R2 values of 0.96-1.00. The regressions for Mn and Co had slopes of 0.82 and 0.84 with R2 values of 0.83 and 0.82, respectively. Addition of HF/H3BO3 did not improve the correlation for any of the elements and degraded the precision somewhat. The technique provides sensitivity and accuracy for trace elements in relatively small aerosol samples used in atmospheric chemistry studies related to SO2 oxidation in cloud droplets. The ability to determine concentrations of a very large number of elements from a single analysis will permit source apportionment of various trace pollutants and hence strategies to control the sources of air pollution. This is particularly important as the health effects of particulate matter are increasingly recognized.  相似文献   

11.
A method for the determination of Cd, Hg, Pb and Se in sediments reference materials by slurry sampling chemical vapor generation (CVG) using isotopic dilution (ID) calibration and detection by inductively coupled plasma mass spectrometry (ICP-MS) is proposed. Two different systems were used for the investigation: an on-line flow injection system (FI-CVG-ICP-MS) and an off-line system with in situ trapping electrothermal vaporization (CVG-ETV-ICP-MS). About 100 mg of the reference material, ground to a particle size ≤50 μm, was mixed with acid solutions (aqua regia, HF and HCl) in an ultrasonic bath. The enriched isotopes 111Cd, 198Hg, 206Pb and 77Se were then added to the slurry in an adequate amount in order to produce an altered isotopic ratio close to 1. For the on-line system, a standing time for the slurry of 12 h before measurement was required, while for the batch system, no standing time is needed to obtain accurate results. The conditions for the formation of the analyte vapor were optimized for the evaluated systems. The following altered isotope ratios were measured: 111Cd/114Cd, 198Hg/199Hg, 206Pb/208Pb e 77Se/82Se. The obtained detection limits in the on-line system, in μg g−1, were: Cd: 0.15; Hg: 0.09; Pb: 6.0 and Se: 0.03. Similar detection limits were obtained with the system that uses the ETV: 0.21 for Hg, 6.0 for Pb and 0.06 μg g−1 for Se. No signal for Cd was obtained in this system. One estuarine, two marine and two river certified sediments were analyzed to check the accuracy. The obtained values by both systems were generally in agreement with the certified concentrations, according to the t-test for a confidence level of 95%, demonstrating that isotope equilibration was attained in the slurries submitted to a chemical vapor generation procedure and detection by ICP-MS. The relative standard deviations were lower than 10%, adequate for slurry analysis. The almost quantitative analytes extractions to the aqueous phase of the slurry must favor equilibration of the added enriched isotope with the isotope in the sample, allowing the use of isotopic dilution calibration for slurry analysis.  相似文献   

12.
Analytical methods used for the isotope dilution inductively coupled plasma mass spectrometric (ID-ICP-MS) measurement of Cd at μg kg−1 and sub-μg kg−1 levels are described and applied to the certification of new dietary supplement, blood, and serum Standard Reference Materials (SRMs). The materials are: SRM 3240 Ephedra sinica Stapf Aerial Parts, SRM 3241 Ephedra sinica Stapf Native Extract, SRM 3243 Ephedra-Containing Solid Oral Dosage Form, SRM 3244 Ephedra-Containing Protein Powder, SRM 966 Toxic Metals in Bovine Blood, Level 1 (L1) and Level 2 (L2), and SRM 1598a Animal Serum. The concentration of Cd in the materials ranges from 120 μg kg−1 down to 0.03 μg kg−1. At these levels, the factors that most influence the accuracy of the ICP-MS data are the procedure blank and spectral and nonspectral interferences. Nonspectral interference, caused by the high concentration of dissolved solids in the matrices investigated, resulted in signal suppression. Matrix separation was used to enhance signal intensity and to reduce spectral interference for the accurate determination of Cd in SRM 1598a and SRM 3244. Chromatographic separation procedures using Chelex for SRM 1598a and anion exchange for SRM 3244 were optimized to achieve the desired separation characteristics without substantially increasing the procedure blank. Sensitivity for the determination of Cd in serum was additionally enhanced through the use of desolvation nebulization. We determined that separations were not required for the accurate ICP-MS determination of Cd in SRM 3240, SRM 3241, SRM 3243, and SRM 966 L2 under optimized analysis conditions. These samples were diluted to a minimum volume and introduced to the ICP-MS via low flow (40–100 μL/min) microconcentric nebulizers. SRM 966 L1 was also analyzed directly, but results were highly variable. The ID-ICP-MS sample preparation and ratio measurement protocols described here resulted in total expanded uncertainties of less than 1% for the determination of 90.85 μg kg−1 Cd in SRM 3240, and less than 10% total expanded uncertainty for the determination of 0.0468 μg kg−1 Cd in SRM 1598a.  相似文献   

13.
电感耦合等离子体质谱法测定硼同位素丰度   总被引:1,自引:0,他引:1  
白鹏  李晓峰  吴军  郭宏杰  李鑫钢 《分析化学》2006,34(9):1338-1340
以硼同位素标准物质NIST SRM 951配制标准溶液,在优化的仪器操作条件下对电感耦合等离子体质谱(ICP-MS)测定的硼同位素质量进行校正,求出校正因子,确定了样品的线性浓度范围,选定样品浓度为1.1 mg/L。在同样的仪器条件下首先测定了硼标准物质的硼同位素丰度比,测量误差为0.2%,然后测定了硼同位素浓缩过程中硼样品的硼同位素丰度比,测定结果的相对标准偏差为1.1%。此外考察了仪器的稳定性。实验结果表明本方法“记忆效应”小,结果可靠,测量精度高。  相似文献   

14.
建立了微波消解电感耦合等离子体质谱同位素稀释(ID/ICP-MS)测定微量汞的方法。考察了仪器参数及测量条件对汞同位素比值RHg(202Hg/200Hg)测量的影响,根据同位素比值测量误差的传递因子优化了富集同位素稀释剂(202Hg98%)的加入量,并以铊同位素比值(205Tl/203Tl)作为RHg(202Hg/200Hg)测量时发生质量歧视效应的校正因子;通过反同位素稀释法标定了富集汞同位素稀释剂的浓度。利用所建立的ID/ICP-MS方法测定了杨树叶(GBW07604)和湖积物(GBW07423)2种标准参考物中汞的含量,回收率分别为112%和100%。该方法具有准确度高、精密度好等优点,且样品前处理简便,适用于土壤及蔬菜等样品中微量及痕量汞的准确测定。  相似文献   

15.
Multielement analyses of environmental reference materials have been performed using existing certified reference materials (CRMs) as calibration standards for inductively coupled plasma–mass spectrometry. The analyses have been performed using a high-performance methodology that results in comparison measurement uncertainties that are significantly less than the uncertainties of the certified values of the calibration CRM. Consequently, the determined values have uncertainties that are very nearly equivalent to the uncertainties of the calibration CRM. Several uses of this calibration transfer are proposed, including, re-certification measurements of replacement CRMs, establishing traceability of one CRM to another, and demonstrating the equivalence of two CRMs. RM 8704, a river sediment, was analyzed using SRM 2704, Buffalo River Sediment, as the calibration standard. SRM 1632c, Trace Elements in Bituminous Coal, which is a replacement for SRM 1632b, was analyzed using SRM 1632b as the standard. SRM 1635, Trace Elements in Subbituminous Coal, was also analyzed using SRM 1632b as the standard.  相似文献   

16.
 The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, have been obtained for these three elements in both of the polyethylene samples of PERM. For each of the certified amount content values an uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations, are described for all three elements. In order to keep the whole certification process as transparent as possible, the preparations of various reagents and materials as well as the sample treatment and blending are described in detail. The mass spectrometry measurements and the data treatment are also explained carefully. The various sources of uncertainty present in the procedure are displayed in the uncertainty budgets. The obtained combined uncertainties for the amount content values were less than 2% relative (k=1) for all investigated elements. The amount contents were in the μmol/kg range, corresponding to mg/kg levels. Received: 21 October 1999 / Accepted: 29 January 2000  相似文献   

17.
Four alternative analytical procedures for the determination of ten important trace impurities (Mg, Cr, Fe, Cu, Zn, Sr, Zr, Cd, Ba, and Pb) in pure alkaline earth fluoride powders were applied using high-resolution inductively coupled plasma mass spectrometry (ICP-MS). Two procedures are based on a wet-chemical microwave digestion with boric acid and quantification by the standard addition technique and isotope dilution mass spectrometry (IDMS), respectively. In addition, analyses are also performed by laser ablation as a direct solid sampling technique applying matrix-matched external calibration as well as isotope dilution of the powdered sample. For most elements good agreement between the different methods is found. Detection limits for laser ablation vary between 0.05 ng g–1 for Zr and 20 ng g–1 for Mg. They are about one to two orders of magnitude lower than those of the wet-chemical procedures, which is mainly due to the high dilution factor during the sample preparation step. Advantages and restrictions of the different analytical procedures are discussed with respect to their routine applicability. Due to its relatively high accuracy, low detection limits, and time-efficiency LA-ICP-IDMS is the preferred choice if no standard reference materials are available.  相似文献   

18.
The National Institute of Standards and Technology (NIST) has developed several Standard Reference Materials (SRMs) based on human serum. NIST SRM 909b, Human Serum, is a lyophilized human serum material with concentrations for seven organic and six inorganic analytes at two levels certified solely by definitive methods (DMs). This material provides the vehicle by which high precision, high accuracy measurements made with DMs at NIST can be transferred through the measurement hierarchy to other laboratories. Isotope dilution gas chromatographic-mass spectrometric (GC-IDMS) methods were applied to measure cholesterol, creatinine, glucose, urea, uric acid, triglycerides, and total glycerides. Thermal ionization isotope dilution mass spectrometry (TI-IDMS) was used for determination of lithium, magnesium, potassium, calcium, and chloride. In addition, chloride was determined by coulometry, providing a comparison between two DMs. Sodium, which lacks a stable isotope that would permit isotope dilution mass spectrometric (IDMS) measurement, was determined by gravimetry. SRM 909b includes certified values for total glycerides and triglycerides, which were not certified in the previous lot of this material (SRM 909a). Improvement in uniformity of vial fill weight in the production of SRM 909b resulted in smaller certified uncertainties over previous freeze-dried serum SRMs. Uncertainties at the 99% level of confidence for relative expanded uncertainty (%) for certification of the organic analytes on a mmol/L/g basis ranged from 0.44% for urea (level II) to 5.04% for glucose (level II). (In-house studies have shown glucose to be a relatively unstable analyte in similar lyophilized serum materials, degrading at about 1% per year.) Relative expanded uncertainties (99% C.I.) for certification of inorganic analytes on a mmol/L/g basis ranged from 0.25% for chloride (level I) to 0.49% for magnesium (level II).  相似文献   

19.
Fang Z  Guo T  Welz B 《Talanta》1991,38(6):613-619
Cadmium, lead and copper were determined in synthetic sea-water, drinking water and the NBS 1643b Trace Elements in Water standard reference material at mug/l. levels by flame atomic-absorption spectrometry after on-line preconcentration by sorbent extraction with a flow-injection system. Bonded silica with octadecyl functional groups packed in a micro column of 100 mul capacity was used to collect diethylammonium diethyldithiocarbamate complexes of the heavy metals in the aqueous samples. The sample loading time was 20 sec at a flow-rate of 3.3 ml/min. Ethanol or methanol was used to elute the adsorbed analytes into the spectrometer. The sample loading rate, elution rate and pH were optimized. Enrichment factors of 19-25 for Cd, Pb and Cu were achieved at sampling frequencies of 120/hr with precisions of 1.4, 1.0 and 1.3% rsd (n = 11), respectively. The detection limits (3sigma) for Cd, Pb and Cu were 0.3, 3 and 0.2 mug/l., respectively. Determination of Cd, Pb and Cu in NBS SRM 1643b showed good agreement with the certified values. Recoveries of Cd and Pb added to sea-water were 95 and 102%, respectively.  相似文献   

20.
The National Institute of Standards and Technology (NIST) has developed several Standard Reference Materials (SRMs) based on human serum. NIST SRM 909b, Human Serum, is a lyophilized human serum material with concentrations for seven organic and six inorganic analytes at two levels certified solely by definitive methods (DMs). This material provides the vehicle by which high precision, high accuracy measurements made with DMs at NIST can be transferred through the measurement hierarchy to other laboratories. Isotope dilution gas chromatographic-mass spectrometric (GC-IDMS) methods were applied to measure cholesterol, creatinine, glucose, urea, uric acid, triglycerides, and total glycerides. Thermal ionization isotope dilution mass spectrometry (TI-IDMS) was used for determination of lithium, magnesium, potassium, calcium, and chloride. In addition, chloride was determined by coulometry, providing a comparison between two DMs. Sodium, which lacks a stable isotope that would permit isotope dilution mass spectrometric (IDMS) measurement, was determined by gravimetry. SRM 909b includes certified values for total glycerides and triglycerides, which were not certified in the previous lot of this material (SRM 909a). Improvement in uniformity of vial fill weight in the production of SRM 909b resulted in smaller certified uncertainties over previous freeze-dried serum SRMs. Uncertainties at the 99% level of confidence for relative expanded uncertainty (%) for certification of the organic analytes on a mmol/L/g basis ranged from 0.44% for urea (level II) to 5.04% for glucose (level II). (In-house studies have shown glucose to be a relatively unstable analyte in similar lyophilized serum materials, degrading at about 1% per year.) Relative expanded uncertainties (99% C.I.) for certification of inorganic analytes on a mmol/L/g basis ranged from 0.25% for chloride (level I) to 0.49% for magnesium (level II). Received: 30 July 1997 / Revised: 24 October 1997 / Accepted: 31 October 1997  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号