首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 921 毫秒
1.
A capillary zone electrophoresis/electrospray ionisation mass spectrometry (CZE/ESI-MS) method has been developed for the separation and detection of 5-aminolaevulinic acid (ALA) and porphobilinogen (PBG). Capillaries were 70 cm long with an inner diameter of 75 micrometer and outer diameter of 375 micrometer. The buffer used was aqueous ammonium acetate (50mM, pH 5.2) with a co-axial 'make-up' flow of methanol/aqueous 0.1% formic acid (1:1 v/v) at a flowrate of 6 microL/min. A voltage of 20 kV was used for CZE and an ESI voltage of 3.5 kV. Full scan data was acquired over the range m/z 100-500 in positive ion mode, from which selected ion electropherograms were extracted; at m/z 132 for the protonated molecular ion of ALA and m/z 210 for the methylenepyrrolenine fragment ion of PBG. The protonated molecular ion of PBG, m/z 227, was found to be too facile to monitor, easily losing ammonia in the electrospray source and better sensitivity was achieved by monitoring the resulting fragment ion. The detection limits were circa 100 attomoles of ALA and 10 attomoles of PBG at a signal-to-noise ratio (S/N) better than 10, providing sufficient sensitivity for clinical use and offering advantages over existing techniques.  相似文献   

2.
A method was developed for the quantitation of pentoxifylline [1-(5-oxohexyl)-3,7-dimethylxanthine] and a primary active metabolite, lisofylline [1-(5-hydroxyhexyl)-3,7-dimethylxanthine], using high-performance liquid chromatography (HPLC)-tandem mass spectrometry. This method was developed in order to overcome problems encountered with HPLC-ultraviolet detection. The operating parameters of the electrospray interface (PE SCIEX, TurboIon Spray) and lens voltages of the triple-quadrupole detector (PE SCIEX 365) were optimized in positive ion mode to obtain the best sensitivity of the analytes. Collision-induced dissociation was used to produce fragment ions, and multiple reaction monitoring was used to quantitate pentoxifylline (m/z 279/181) and lisofylline (m/z 263/181). Dichloromethane was used to extract the drug, metabolite, and the internal standard (3-isobutyl-1-methylxanthine) from plasma. A reverse-phase C8(2) 150 x 1.0 mm HPLC column was used to resolve all three compounds in less than 6 min. Calibration curves were generated using peak area and were linear from 1 to 1000 ng/mL (R(2) > 0.99). The small sample volume, ease of extraction, and sensitivity provide advantages over more conventional methods of quantitation.  相似文献   

3.
Mass spectrometry coupled with a pyrolysis inlet system (Pyr-ms) is compared with high performance liquid chromatography (HPLC) for the determination of vancomycin and its crystal degradation products (CDP-Is) in human serum. Quantitative analysis of Pyr-ms was performed by selected ion monitoring (SIM) method at 108 mass:charge (m/z) of pyrolysis product of vancomycin. 3-Nitroaniline (138 m/z) was used as an internal standard. A mu-Bondapak C(18) column and the gradient mobile phase of triethylamine buffer (pH 6.2), acetonitrile and tetrahydrofuran and a photometric detection at 205 nm are found to be the optimum conditions for the HPLC determination of vancomycin and CDP-Is. The limit of detection (LOD=1 ng ml(-1)), linearity (1 ng ml(-1)-10 mg ml(-1)), relative standard deviation (R.S.D.=1%), time analysis (1/2 h) and sample volume (50 mul) of Pyr-ms are far better than of the HPLC method. However, the HPLC method can individually determine the concentration of vancomycin and its degradation products.  相似文献   

4.
A novel approach for the measurement of (37)Cl, (81)Br and (34)S in organic compounds containing chlorine, bromine, and sulphur is presented to overcome some of the major drawbacks of existing methods. Contemporary methods either require reference materials with the exact molecular compositions of the substances to be tested, or necessitate several laborious offline procedures prior to isotope analysis. In our online setup, organic compounds are separated by gas chromatography (GC) coupled to a high-temperature reactor. Using hydrogen as a makeup gas, the reactor achieves quantitative conversion of chlorinated, brominated and sulphurated organic compounds into gaseous hydrogen chloride (HCl), hydrogen bromide (HBr), and hydrogen sulphide (H(2)S), respectively. In this study, the GC interface was coupled to a quadrupole mass spectrometer operated in single-ion mode. The ion traces of either H(35)Cl (m/z 36) and H(37)Cl (m/z 38), H(79)Br (m/z 80) and H(81)Br (m/z 82), or H(2)(32)S (m/z 34) and H(2)(34)S (m/z 36), were recorded to determine the isotopic ratios of chlorine, bromine, and sulphur isotopes. The conversion interface presented here provides a basis for a novel method for compound-specific isotope analysis of halogenated and sulphur-containing compounds. Rapid online measurements of organic chlorine-, bromine- and sulphur-containing mixtures will facilitate the isotopic analysis of compounds containing these elements, and broaden their usage in fields of environmental forensics employing isotopic concepts.  相似文献   

5.
An HPLC/MS/MS method for the determination of arbidol in human plasma was developed. Arbidol and internal standard (loratadine) were extracted from alkaline plasma with tert-butyl methyl ether and analyzed on a Zorbax SB C18 column (30 x 2.1 mm id, 3.5 microm particle size). The detection was by monitoring arbidol at m/z 479.1 --> 434.1 and the internal standard at m/z 383.2 --> 337.2. The method was validated according to U.S. Food and Drug Administration guidelines. The calibration curve was linear over the range of 0.5-500 ng/mL using a 100 microL sample volume. The intraday and interday precisions were less than 6.5%, and acceptable values were obtained for accuracy, recovery, and sensitivity. The developed method was selective, simple, sensitive, and easily applicable.  相似文献   

6.
A liquid chromatography-electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous quantitation of nicorandil and its denitrated metabolite, N-(2-hydroxyethyl)-nicotinamide, in rat plasma. After a liquid-liquid extraction step, chromatographic separation was performed on a ShinPack C(18) column with an isocratic mobile phase composed of methanol and 2 mM aqueous ammonium acetate containing 0.03% (v/v) formic acid (33:67 v/v). Procainamide was used as an internal standard (IS). Selected reaction monitoring was performed using the transitions m/z 212 → m/z 135, m/z 166 → m/z 106 and m/z 236 → m/z 163 to quantify nicorandil, its denitrated metabolite and IS, respectively. Calibration curves were constructed over the range of 5-15,000 ng.ml(-1) for both nicorandil and its metabolite. The mean relative standard deviation (RSD%) values for the intra-run precision were 5.4% and 7.3% and for the inter-run precision were 8.5% and 7.3% for nicorandil and its metabolite, respectively. The mean accuracy values were 100% and 95% for nicorandil and its metabolite, respectively. No matrix effect was detected in the samples. The validated method was successfully applied to a pharmacokinetic study after per os administration of nicorandil in rats.  相似文献   

7.
A liquid chromatographic/tandem mass spectrometric method is described for the determination of phencyclidine (PCP) in small volumes of rat serum (e.g. 50 microl). Samples were extracted using a mixed-mode strong cation-exchange column and then separated isocratically using a narrow-bore (2.1 mm i.d.) 3 microm Hypersil phenyl column and a mobile phase consisting of an ammonium formate buffer (pH 2.7) with 60% (v/v) methanol. Detection was accomplished using positive ion electrospray ionization in the multiple reaction monitoring mode. Mass spectra were obtained and peaks were observed at an m/z (% abundance) of 244 (100), 159 (25), and 86 (89). Tandem mass spectra were also obtained from the m/z 244 precursor ion with peaks observed at m/z 159 (100), 86 (96), and 91 (11). Optimum serum PCP sensitivity and precision were obtained at a transition of m/z 244 --> 159. Matrix-associated ion suppression did not significantly affect the accuracy (100-112%) or precision (CV < or =8%) of the assay. The lower limit of quantitation was 1 ng ml(-1) in 50 microl of serum. The method was used to study the serum pharmacokinetics of PCP in rats after an intravenous bolus dose of PCP.  相似文献   

8.
The present work was aimed at the development of a capillary electrophoretic analysis of gamma-hydroxybutyric acid (GHB) using electrospray ion trap mass spectrometry to achieve the direct and unequivocal detection of this analyte in human urine. Optimized capillary electrophoretic conditions were: injection, 20 s at 0.5 psi (1 psi = 6894.76 Pa); buffer electrolyte, 12.5 mM ammonium formate adjusted to pH 8.35 with diethylamine; fused silicacapillary: 100 cm x 50 microm i.d.; separation voltage, 25 kV (forward polarity) + 0.5 psi; room temperature. Electrospray and mass spectrometric conditions were: drying gas and nebulizing gas (nitrogen) at flow rate 3 l/min, temperature 250 degrees C, nebulizer pressure: 10 psi; sheath liquid solution: methanol-water (90:10) containing 0.1% ammonia delivered at 3 microl/min; spray voltage 3.5 kV. Mass spetrometric detection was carried out in the selected ion monitoring mode of negative molecular ions at 103 m/z for GHB and 115 m/z for maleic acid (I.S.). Under these conditions the baseline separation of GHB and the I.S. was obtained. The selectivity of the analysis allowed for direct injection of unextracted urine, previously diluted 1:4 with water. Linearity was assessed in the GHB concentration range from 80 to 1280 microg/ml in urine. Analytical sensitivity (as limit of detection) resulted about 5 microg/ml in water and 20 microg/ml in original urine. Analytical precision was fairly acceptable with R.S.D. values lower than 5% for migration times and 18% for quantitation in real samples, in both intra day and day-to-day experiments. On these grounds, the developed method can be adopted for rapid identification of acute intoxications from GHB in humans.  相似文献   

9.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of camboginol in the extract of fruit rinds of Garcinia cambogia has been developed. Separation was achieved isocratically on an RP C(18) column using a solvent system consisting of a mixture of acetonitrile-water (9:1) and methanol-acetic acid (99.5:0.5) in the ratio of 30:70 as mobile phase at a flow rate of 0.4 mL/min. A multiple reaction monitoring (MRM) method was developed for quantification of camboginol in the fruit rinds extract of G. cambogia using MRM transitions of m/z 601.4 --> m/z 176.7 and m/z 601.4 --> m/z 448.9, respectively. The calibration curve based on peak area against concentration was linear up to 50 ng/mL with a detection limit of 0.5 ng/mL. The method showed satisfactory reproducibility with a coefficient of variation of less than 6%. The method was successfully applied for quantification of camboginol in different Garcinia extracts.  相似文献   

10.
The intermediates ISO3- (m/z=207) and IS2O3- (m/z=239) generated in aqueous (NaI/Na2S2O3) microdroplets traversing dilute O3 gas plumes are detected via online electrospray mass spectrometry within approximately 1 ms, and their stabilities gauged by collisionally induced dissociation. The simultaneous detection of anionic reactants and the S2O62-, HSO4-, IO3-, and I3- products as a function of experimental conditions provides evidence of genuinely interfacial reaction kinetics. Although O3(aq) reacts about 3 times faster with I- than with S2O32- in bulk solution, only S2O32- is significantly depleted in the interfacial layers of [I-]/[S2O32-]=10 microdroplets below [O3(g)] approximately 50 ppm.  相似文献   

11.
提出了食用植物油中胆固醇的超高效液相色谱-串联质谱测定方法。食用植物油经皂化后用石油醚-乙醚(1+1)溶液提取,以Waters ACQUITY UPLC BEH C18色谱柱(50mm×2.1mm,5μm)为分离柱,以甲酸-甲醇(0.1+99.9)溶液为流动相,以2,2,3,4,4,6-d6胆固醇为内标,采用大气压化学电离源在多反应监测负离子模式下进行测定,胆固醇和内标的定量离子对分别为m/z369.2/146.9,369.2/160.9和375.2/166.5。胆固醇在0.1~5mg·L-1范围内呈线性,测定下限(10S/N)为0.02ng。在3个浓度水平上对方法做回收试验,测得回收率在102%~110%之间。  相似文献   

12.
Tsai JL  Wu WS  Lee HH 《Electrophoresis》2000,21(8):1580-1586
A rapid, sensitive method for the determination of morphine and amphetamine was developed using capillary zone electrophoresis coupled with electrospray interface (ESI), ion-trap tandem mass spectrometry (CE-ESI-MS2). Morphine and amphetamine were separated in 20 mM ammonium acetate buffer (pH 6.6) and detected by ion-trap mass detector in different analytical time segments (0-6.25 min for amphetamine and 6.25-12.0 min for morphine) in which the tune file for each compound was used separately. Molecular ions of morphine (m/z 286) and amphetamine (m/z 136) were detected at 5.77 and 6.83 min, respectively, while product ions of MS2 for each compound (m/z 229, 201 for morphine and m/z 119 for amphetamine) were detected almost exactly at the same time with their parent compounds. The limits of detection (LOD) for MS2 determination were 30 and 50 ng/mL for amphetamine and morphine, respectively, with an S/N ratio of 3. For more sensitive detection of morphine, the sample was injected for a longer time (i.e., 80 s) and hydrodynamically transported into a CE capillary for MS detection. Morphine and its product ion appear at 0.36 and 0.39 min on the ion chromatogram, respectively, with a five-fold increase of detection sensitivity (LOD, 10 ng/mL). The CE-MS system thus established was further applied for forensic urine samples screened as morphine-positive by fluorescence polarization immunoassay (FPIA). These results indicated the feasibility of CE-ESI-MS2 for confirmative testing of morphine in urine sample.  相似文献   

13.
The sensitive detection of sulphur and phosphorous-containing compounds using HPLC-ICPMS is difficult due to the high background caused by polyatomic interferences. One potential solution to the problem of polyatomic interferences for S and P is to react the latter with oxygen in the collision hexapole to separate them from interferences eg; (O2 on S and NOH on P). This has the effect of moving the detection mass from 31 and 32 to 47 and 48 m/z for P and S respectively. This region is clear from interferences thereby providing an increase in the sensitivity of detection for the analytes of approximately 50–100 fold. For omeprazole, a model S containing compound, a limit of detection (LOD) of 800 pg on column was achieved, an increase of ca. 100 fold in sensitivity. Similarly in the case of ZD6126 a phosphorous-containing pro-drug, an increase in sensitivity of 50 times was observed with an LOD of 1 ng on column.  相似文献   

14.
An optimized high-performance liquid chromatographic method coupled with tandem mass spectrometric detection (LC-MS/MS) was developed for the simultaneous determination of honokiol and magnolol in Magnolia officinalis. Honokiol and magnolol were separated from the extracts using a reversed-phase C(18) column with a mobile phase consisted of acetonitrile and water (75:25, v/v) at a flow-rate of 0.8 mL/min. Selected reaction monitoring (SRM) mode was used for all sample quantification by the precursor-ion/product ion pair m/z 265 --> m/z 224 for honokiol and m/z 265 --> m/z 247 for magnolol. Validation data showed that this method has good linearity (r(2) > 0.995) over the concentration range of 0.0025-0.5 microg/mL for honokiol and magnolol, and both intra- and inter-day variability were acceptable within 15% at the lowest concentrations for this method. This proposed method provides excellent specificity, higher sensitivity and shorter run time than conventional methods and was applied successfully to determine the contents of honokiol and magnolol in M. officinalis.  相似文献   

15.
A rapid, sensitive and selective method has been developed and validated for the analysis of the contaminant ethyl carbamate (EC) in bread products at the part-per-billion level. The new procedure uses positive ion chemical ionisation (PICI) and tandem mass spectrometry (MS/MS), combined with gas chromatography (GC), on a 'bench-top' triple-quadrupole mass spectrometer. Ammonia was the PICI reagent gas of choice because of its ability to produce abundant [M+H]+ and [M+NH4]+ ions from EC and deuterium-labelled EC (LEC) used as an internal standard. For identification and quantification, selected reaction monitoring (SRM) was used to follow the precursor-to-product ion transitions of m/z 107 --> 90, m/z 107 --> 62 and m/z 90 --> 62 for EC, as well as m/z 112 --> 63 for the LEC internal standard. The limits of detection and quantification were 0.6 and 1.2 microg kg(-1), respectively, and the recovery of the method was 101 +/- 10% at 10 microg kg(-1) and 98 +/- 5% at 100 microg kg(-1). The precision of the method, established under conditions of intermediate reproducibility, did not exceed a relative standard deviation of 7%. The quantitative performance of the new GC/PICI-SRM procedure compared favourably with that of a reference method based on GC/MS and selected ion monitoring (correlation coefficient, r = 0.997). However, the new method had the advantages of reduced sample preparation time, improved sensitivity and unambiguous identification of EC at all concentrations. Application of the new method to the analysis of 50 UK breads showed that levels of EC ranged from 0.6 to 2.3 microg kg(-1) in retail products and from 3.1 to 12.2 microg kg(-1) for breads prepared using domestic breadmaking machines (dry weight basis). Toasting bread in a domestic toaster led to increases of between two- and three-fold in mean EC concentrations.  相似文献   

16.
A method based on column switching packed capillary liquid chromatography electrospray mass spectrometry has been developed for the determination of the adduct glyoxal-deoxyguanosine, a biomarker candidate for the assessment of glyoxal exposure, in DNA hydrolysate solutions. Microgram amounts of DNA were isolated and enzymatically hydrolyzed to deoxyribonucleosides, prior to ultrafiltration and subsequent dilution to a sample solution consisting of water-acetonitrile-formic acid (98 : 2 : 0.2, v/v). The sample solution was loaded onto a 1 mm I.D. x 5 mm Hypercarb (5 mum) porous graphitic carbon trap column for analyte enrichment using an injection volume of 200 mul, and was subsequently back-flushed onto a 0.30 mm I.D. x 150 mm Lichrospher diol (5 mum) analytical column. The samples were loaded with a flow rate of 40 mul min(-1) and glyoxal-deoxyguanosine was desorbed from the trap column and eluted with an isocratic mobile phase consisting of water-acetonitrile-formic acid (50 : 50 : 0.2, v/v) at a flow rate of 5 mul min(-1). Mass spectrometric determination of glyoxal-deoxyguanosine was obtained by multiple reaction monitoring of the transition [M + H](+)m/z 326 --> m/z 210. The method was evaluated over the concentration range 0.25-50 ng ml(-1) of glyoxal-deoxyguanosine in the hydrolysate of 5 mug DNA. The method was linear with a correlation coefficient of 0.9998 in this range. The within-day (n = 6) and between-day (n = 6) precisions were determined as 1.2-11% and 1.4-11% RSD, respectively, and the recovery was close to 100%. The mass limit of detection was 15 pg, corresponding to a concentration limit of detection of 75 fg mul(-1) DNA hydrolysate solution, corresponding to 48 adducts per 10(6) normal nucleosides. The method was applied for the determination of glyoxal-deoxyguanosine in DNA hydrolysate solutions of calf thymus DNA and cell cultures after reaction or incubation with glyoxal.  相似文献   

17.
Nicotine and its metabolite, cotinine, were measured in rat plasma and brain by gas chromatography-mass spectrometry. Both agents were extracted from plasma and brain, separated on a capillary column, and quantified by single-ion monitoring. The major fragment ions of nicotine and cotinine at m/z 84 and m/z 98, respectively, were monitored by electron-impact ionization detection and the protonated molecular ions at m/z 163 and m/z 177, respectively, were monitored by chemical ionization detection. Both compounds were quantified using deuterium-labeled nicotine and cotinine, respectively, as internal standards.  相似文献   

18.
Glycoalkaloids are naturally occurring nitrogen-containing compounds present in many species of the family Solanaceae, including cultivated and wild potatoes (Solanum spp.), tomatoes (Lycopersicon spp.), etc. These compounds have pharmacological and toxicological effects on humans due to their significant anticholinesterase activity and disruption of cell membranes. Herein is reported the development of a capillary electrophoresis (CE) method using nonaqueous (NA) separation solutions in combination with ion trap mass spectrometry (MS and MS/MS) detection for the identification and quantification of glycoalkaloids and their relative aglycones. A mixture 90:10 v/v of MeCN-MeOH containing 50 mM ammonium acetate and 1.2 M acetic acid (applied voltage of 25.5 kV) was selected as a good compromise for the separation and detection of these compounds. The electrospray MS measurements were carried out in the positive ionization mode using a coaxial sheath liquid, methanol-water (1:1) with 1% of acetic acid at a flow rate of 2.5 microL/min. Under optimized experimental conditions, the predominant ion was the protonated molecular ion ([M+H](+)) of solanidine (m/z = 398), tomatidine (m/z = 416), chaconine (m/z = 852), solanine (m/z = 868), and tomatine (m/z = 1034). MS/MS experiments were carried out systematically by changing the relative collisional energy and monitoring the intensities of the fragment ions that were not high enough to allow better quantification than with the mother ions. The method was used for analyzing glycoalkaloids in potato extracts.  相似文献   

19.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

20.
A new method for the determination of anti-diabetic drugs metformin and rosiglitazone based on the use of capillary electrophoresis with electrospray mass spectrometry was developed. The proposed method allowed their separation within 11 min by using 50 mM formic acid at +20 kV. Positive electrospray ionization and selected ion monitoring [M+H](+) of metformin (m/z=130) and rosiglitazone (m/z=358) were performed. Several important experimental parameters influencing electrospray ionization of metformin and rosiglitazone were studied. The final composition of sheath liquid was water/methanol/formic acid (50:49.5:0.5, v/v/v), at a flow rate of 2 μL/min. The developed method was applied for the determination of metformin and rosiglitazone simultaneously in human serum after protein precipitation with acetonitrile. The limits of detection of developed method were 4.42 and 2.14 ng/mL for rosiglitazone and for metformin, respectively, which is sufficient for therapeutic serum concentration levels monitoring for both studied drugs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号