共查询到20条相似文献,搜索用时 0 毫秒
1.
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments. 相似文献
2.
Liquid chromatography/ultraviolet (LC/UV) and mass spectrometry/mass spectrometry (MS/MS) libraries containing 39 phenolic compounds were established by coupling a LC and an ion trap MS with an electrospray ionization (ESI) source, operated in negative ion mode. As a result, the deprotonated [M-H]- molecule was observed for all the analyzed compounds. Using MS/MS hydroxybenzoic acid and hydroxycinnamic acids showed a loss of CO2 and production of a [M-H-44]- fragment and as expected, the UV spectra of these two compounds were affected by their chemical structures. For flavonol and flavonol glycosides, the spectra of their glycosides and aglycones produced deprotonated [M-H]- and [A-H]- species, respectively, and their UV spectra each presented two major absorption peaks. The UV spectra and MS/MS data of flavan-3-ols and stilbenes were also investigated. Using the optimized LC/MS/MS analytical conditions, the phenolic extracts from six representative wine samples were analyzed and 31 phenolic compounds were detected, 26 of which were identified by searching the LC/UV and MS/MS libraries. Finally, the presence of phenolic compounds was confirmed in different wine samples using the LC/UV and LC/MS/MS libraries. 相似文献
3.
Fang L Demee M Cournoyer J Sierra T Young C Yan B 《Rapid communications in mass spectrometry : RCM》2003,17(13):1425-1432
A nine-channel multiplexed electrospray (MUX) liquid chromatography ultraviolet time-of-flight mass spectrometry (LC/UV/TOFMS) system has been used to simultaneously measure accurate masses of eluting components from eight parallel gradient LC columns. Accuracies better than 5 and 10 ppm were achieved for 50 and 80% of samples, respectively, from a single batch analysis of ten plates (960 samples) of a Fmoc-Asp(OtBu)-OH and reserpine mixture. Combinatorial library compounds were analyzed using this parallel high-throughput system in both positive and negative modes to rigorously verify expected products and identify side products. A mass accuracy of 10 ppm root mean square (RMS) is routinely obtained for combinatorial library samples from this high-throughput accurate mass LC/MS system followed by automated data processing. This mass accuracy is critical in revealing combinatorial synthesis problems that would be missed by unit mass measurement. 相似文献
4.
Fang L Cournoyer J Demee M Zhao J Tokushige D Yan B 《Rapid communications in mass spectrometry : RCM》2002,16(15):1440-1447
We report a high-throughput liquid chromatography/mass spectrometry (LC/MS) protocol for analyzing large combinatorial libraries using an eight-channel parallel LC/UV/MS (MUX-LCT) system. System configuration, linear response range in UV absorbance, LC column selection, and flow rate were optimized for 24 h/7 day unattended operations. Combinatorial libraries were analyzed on this system at a rate of 3200 compounds per day for a 3.5 min cycle time per injection. This parallel system is compared with a single-channel system in terms of performance and operation. 相似文献
5.
Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry 总被引:1,自引:0,他引:1
Grant RP Cameron C Mackenzie-McMurter S 《Rapid communications in mass spectrometry : RCM》2002,16(18):1785-1792
The development of turbulent flow chromatography (TFC) has enabled considerable growth in the utility of on-line direct-injection technologies. TFC has now become established in a large number of varied analytical environments, particularly drug discovery/pharmacokinetics, metabolite profiling, combinatorial library purification, pre-clinical and clinical GLP applications. The utility of turbulent flow technology for in-house pre-clinical and clinical quantitative applications has necessitated extensive valve-cleaning procedures, and consequently lengthy cycle-times, to effectively remove the system carry-over. In-house requirements for assay validation require carry-over less than 20% of the lowest level of quantification (LLOQ), corresponding to 0.02% carry-over for a linear calibration range incorporating 3 orders. A generic turbulent flow chromatography protocol has been developed for drug discovery that incorporates polymeric turbulent flow extraction (cyclone) with C18-based reverse-phase chromatography. Further, multiple wash steps are incorporated within the methodology to meet in-house requirements for carry-over. Selection of novel switching-valve materials based on polyarylethyl ketone (PAEK) and Hastelloy/Valcon E autosampler injection hardware has enabled us to significantly impact the cycle-time required to reduce carry-over. Consequently, optimal usage of switching valves has enabled parallel operation for a generic on-line direct-injection methodology to successfully reduce the total cycle-time. Overall reductions from 4 min per sample to 90 s per sample are shown with comparable data quality using a proprietary target molecule from 0.1-100 ng/mL. This paper describes the hardware configuration and methodologies utilized to perform generic serial and parallel on-line direct-injection using a Turboflow HTLC 2300 system. 相似文献
6.
7.
Feng B Patel AH Keller PM Slemmon JR 《Rapid communications in mass spectrometry : RCM》2001,15(10):821-826
The preparation of protein substrates requires that a large number of chromatographic fractions be analyzed for the presence of reactants, products and by-products. Analyses using linear matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) or single column liquid chromatography/mass spectrometry (LC/MS) have been inadequate because of mass resolution or throughput. Therefore, a high-throughput method employing an eight-channel parallel reverse-phase LC/MS system was developed. This system is capable of screening fractions from preparative ion-exchange chromatography with the required mass accuracy and throughput so that the protein purification process can be monitored in a relatively short period of time. As an example, the purification and analysis of an acylated protein with a molecular weight of 8.9 kDa is described and the detection of a contaminating by-product that differs in size by less than 20 Da is demonstrated. Using the current instrumentation and approach, it is practical to analyze 50 protein-containing fractions from column chromatography in less than 1 hour using parallel LC/MS. 相似文献
8.
Optimal liquid chromatography/mass spectrometric [LC/MS(/MS)] analysis depends on both the LC selectivity and the electrospray efficiency. Here, we outline a simple and comprehensive LC/MS/MS strategy for the rapid analysis of a wide range of pharmaceutical compounds. To achieve ultrafast LC separation with little sacrifice in peak capacity, one needs to start with a column that provides a good peak capacity at short gradient run times; secondly, it is important to use high flow rates to achieve a good gradient peak capacity. Following this strategy, it was possible to baseline-resolve a mixture (containing acidic, neutral, and basic pharmaceutical analytes) in seconds. By coupling the selectivity provided by fast LC separation with the specificity of MS/MS detection, it is possible to separate and identify a wide range of analytes in 1-min gradient analyses. Also, the impact of mobile phase pH on both the chromatographic selectivity and the MS/MS sensitivity is demonstrated. 相似文献
9.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. 相似文献
10.
Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented. 相似文献
11.
Measurement of the ratio of testosterone (T) and epitestosterone (E) in urine has been used as an indication of 'natural' steroid supplementation for a decade. The direct measurement of the glucuronide and sulfate conjugates of testosterone and epitestosterone by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) should resolve a number of issues regarding unusual metabolism due to either genetic disposition or attempts to avoid detection of abuse. Determination of nanomoles per liter (0.1 ppb) concentrations of analytes in a complex biological matrix by HPLC/MS/MS is complicated by sample matrix-specific ion suppression during ESI. Deuterated internal standards of all compounds were used to overcome the effects of suppression. Comparison of the HPLC/MS/MS method with a two-part gas chromatographic/mass spectrometric method showed statistical equivalence in urine samples. Analysis of urine samples with elevated T-glucuronide to E-glucuronide ratios did not show that a significant number could be explained by an elevated excretion of epitestosterone sulfate. The HPLC/MS/MS method was also used further to characterize genetic and metabolic factors that give rise to unusual T/E ratios. 相似文献
12.
Siethoff C Feldmann I Jakubowski N Linscheid M 《Journal of mass spectrometry : JMS》1999,34(4):421-426
The quantitative determination of nucleotides from DNA modified by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liquid chromatography (HPLC). LC/ICP-MS (resolution > 1500 to discriminate against 15N16O+ and 14N16OH+) was employed to determine quantitatively the content of modified nucleotides in standard solutions based on the signal of phosphorus; phosphoric acid served as an internal standard. By means of the standard addition technique the sensitivity of the LC/ESI-MS approach was subsequently determined. Since a comparison of UV, ICP and ESI-MS data suggested that in ESI-MS the ionization efficiency of the adducts is identical within the error limits, quantitative determination of all adducts is possible. For LC/ESI-MS with single ion monitoring, the detection limit for styrene oxide adducts of nucleotides was determined to be 20 pg absolute or 14 modified in 10(8) unmodified nucleotides in a 5 micrograms DNA sample, which comes close to the best methods available for the detection of chemical modifications in DNA. 相似文献
13.
A new ultraviolet (UV) signal actuated switching valve for diverting the main matrix compound to waste, preventing it entering the ion source of the mass spectrometer is described. Sensitivity for trace impurities eluting after the drug substance cimetidine or related compounds could be enhanced by a factor of 4-5. The increase in sensitivity was dependent on the type of ion source which interfaced the mass spectrometer. The benefit of the switching valve was greater with a line of sight type source than with an orthogonal one. The detection limit for a trace compound in a matrix compound was improved by up to a factor of 10 with the line of sight type source but only by a factor of 5 with the orthogonal source. 相似文献
14.
Zhou S Zhou H Larson M Miller DL Mao D Jiang X Naidong W 《Rapid communications in mass spectrometry : RCM》2005,19(15):2144-2150
A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed. Experiments for evaluating the resolution, peak shape, sensitivity, speed, and matrix effect were conducted with dextromethorphan and its metabolite dextrorphan as model compounds in human plasma matrix. It was demonstrated that the total run time for this assay with a baseline separation of two analytes is less than 1.5 min. 相似文献
15.
16.
Pérez S Farkas M Barceló D Aga DS 《Rapid communications in mass spectrometry : RCM》2007,21(24):4017-4022
Glutathione S-transferases (GSTs) isolated from maize were used to catalyze the conjugation of glutathione (GSH) with chloroacetanilide herbicides, producing stable conjugates that were structurally characterized using ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/QqToF-MS) and liquid chromatography/ion trap mass spectrometry (LC/IT-MS). Enzyme-mediated dechlorination of alachlor, metolachlor, and propachlor resulted during GSH conjugation as revealed by the mass spectra of the conjugates, which was confirmed by the loss of the chlorine isotopic signature and from high accurate mass measurements. Several fragmentation patterns in the mass spectra of the chloroacetanilide-GSH conjugates can be used to verify the identities of the enzyme reaction products, such as characteristic ions corresponding to the neutral loss of glutamic acid residue (129 Da) and water (18 Da) observed in the product ion spectrum. For the first time, data are presented showing detection of chloroacetanilides that are conjugated with two GSH molecules, in addition to the known single GSH conjugates. 相似文献
17.
Favetta P Dufresne C Désage M Païssé O Perdrix JP Boulieu R Guitton J 《Rapid communications in mass spectrometry : RCM》2000,14(20):1932-1936
Using hyphenated analytical techniques, gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), a study on minor propofol metabolites in human urine was conducted. These techniques allowed identification of two new phase I metabolites (2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol). In addition, their four corresponding conjugates (three glucuronides and one sulphate) were detected. Thus in human urine at least eight conjugate metabolites are produced, derived from four different aglycones (propofol; 2, 6-diisopropyl-1,4-quinol; 2-(omega-propanol)-6-isopropylphenol and 2-(omega-propanol)-6-isopropyl-1,4-quinol). 相似文献
18.
Chen X Lou Z Zhang H Tan G Liu Z Li W Zhu Z Chai Y 《Rapid communications in mass spectrometry : RCM》2011,25(11):1661-1674
An approach for the identification of multiple components in traditional Chinese medicine injections (TCMIs) using a combination of hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) coupled with time-of-flight mass spectrometry (TOFMS) was developed for the quality control of Guanxinning injection (GXNI), a widely used TCMI, composed of Salvia miltiorrhiza and Ligusticum Chuanxiong. A total of 50 compounds from five compound classes, including saccharides, amino acids, organic acids, phenolic acids and phthalides, were identified or tentatively characterized on the basis of accurate mass measurements and subsequent TOFMS product ions. Six groups of isomers of phenolic acids and saccharides were tentatively distinguished. It was observed that the ESI-TOFMS fragmentation behavior of phthalides was different in negative and positive ion mode, and the fragmentation pathways were tentatively elucidated using structurally-relevant product ions. Several highly polar constituents were characterized for the first time from GXNI by HILIC/TOFMS. In addition, all the constituents identified from GXNI were further assigned in the two individual crude drugs. The integrated strategy has provided a powerful approach for the separation and identification of the multiple components in GXNI, and it has also assisted in the establishment of methods for the comprehensive safety and quality evaluation of TCMIs. 相似文献
19.
An approach for screening and identification of multi-component in complex traditional Chinese medicine systems with a combinative LC/MS (MSn) technique was described in this paper. The chemical profile of Qingkailing injection, a well-known traditional Chinese formula in China, was studied using the established method as for an application. Benefit from combining the accurate mass measurement of LC/TOF-MS to generate elemental compositions and the complementary multilevel structural information provided by LC/ion trap MSn, 33 components in Qingkailing injection were identified in all. The three isomers of chlorogenic acid, isochlorogenic acid and neochlorogenic acid which are derived from Flos Lonicerae, one of the medicinal materials in Qingkailing, were differentiated by verifying their MS3 fragmentation data. All the components identified were surveyed and classified according to their medicinal materials derivation. This study is expected to provide an effective and reliable pattern for comprehensive and systematic characterization of the complex traditional Chinese medicine systems. 相似文献
20.
Timothy MacMahon Mark Chace 《Journal of the American Society for Mass Spectrometry》1994,5(4):299-304
A number of polymers were hydrolyzed in NH4OH and studied using gas chromatography/ mass spectrometry (GC/MS) and particle beam liquid chromatography/mass spectrometry (particle beam LC/MS) techniques. The polymers studied in this report were as follows: BPDA-PDA, BPDA-PDA-ODA, BPDA-PDA-GFDA, PMDA-ODA, and BTDA-APB. Some of the polymer samples were hydrolyzed in both their acid and imide forms to see if any mass spectrometric differences could be detected. ln all cases, the acid and imide spectra looked the same. GC/MS was unable to determine either the amine or acid portion of these polymers via a direct injection of the sample, but when the samples were first extracted with diethyl ether and this ether extract was injected into the chromatograph, the amine portion of the polymers was readily detected. The acid portion was, again, not detected in either the sample or the ether extract. The particle beam was able to detect both the amine and acid monomeric units in the nonextracted sample. 相似文献