首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic (HPLC) method and a cyclodextrin-modified micellar electrokinetic chromatographic (CD-MEKC) method were developed to separate and determine oleanolic acid (OA) and ursolic acid (UA) in Prunella vulgaris. HPLC separations were carried out on a Hedera ODS C18 column with methanol -H2O- acetic acid (85:15:0.3, v/v/v) as mobile phase at a flow-rate of 0.8 ml min?1. CD-MEKC analysis was performed on a CL1030 capillary electrophoresis system with a 6% (v/v) methanol solution (pH = 9.0) containing 10 mM disodium tetraborate, 10 mM sodium dihydrogen phosphate, 50 mM sodium dodecylsulfate (SDS), 15 mM 2-hydroxypropyl-β-cyclodextrin (2-HP-β-CD) as background electrolyte. The analytical results of HPLC and CD-MEKC were compared with each other. CD-MEKC has better analytical efficiency for two components, and the analytical time (15 min) was shorter than that of HPLC (35 min).  相似文献   

2.
An effective and accurate method was developed for the extraction of astaxanthin from Laminaria japonica with subsequent separation by ionic liquid-based monolithic cartridge. The optimized extraction conditions including extraction solvent(ethanol), extraction time(90 min) and ultrasonic power(75 W) were obtained by systematical investigation. Chromatographic analysis was performed on a C18 column with ultraviolet(UV) detection at 476 nm, and a solution consisting of methanol/acetonitrile/H2O/dichloromethane(83:6:6:5, volume ratio) was used as the mobile phase at a flow rate of 0.7 mL/min. After ionic liquid-based monolithic solid phase extraction, 17.82 μg/g astaxanthin was obtained from Laminaria japonica. This ionic liquid-based monolithic cartridge exhibits high affinity and selectivity for astaxanthin, and it can be potentially used as the stationary phase of high performance liquid chromatography(HPLC).  相似文献   

3.
HPLC atmospheric pressure chemical ionization (APCI)/MS, GC MS, HPLC diode array detection (DAD), and NMR were used for the identification of astaxanthin and astaxanthin fatty acid esters in krill (Euphausia superba Dana). Matrix solid phase dispersion was applied for the extraction of the carotenoids. This gentle and expeditious extraction technique for solid and viscous samples leads to distinct higher enrichment rates than the conventional liquid-liquid extraction. The chromatographic separation was achieved employing a C30 RP column that allows the separation of shape-constrained geometrical isomers. A methanol/tert-butylmethyl ether/water gradient was applied. (all-E) Astaxanthin and the geometrical isomers were identified by HPLC APCI/MS, by coelution with isomerized authentical standard, by UV spectroscopy (DAD), and three isomers were unambiguously assigned by microcoil NMR spectroscopy. In this method, microcoils are transversally aligned to the magnetic field and have an increased sensitivity compared to the conventional double-saddle Helmholtz coils, thus enabling the measurement on small samples. The carotenol fatty acid esters were saponified enzymatically with Lipase type VII from Candida rugosa. The fatty acids were detected by GC MS after transesterification, but also without previous derivatization by HPLC APCI/MS. C14:0, C16:0, C16:1, C18:1, C20:0, C20:5, and C22:6 were found in astaxanthin monoesters and in astaxanthin diesters. (all-E) Astaxanthin was identified as the main isomer in six fatty acid ester fractions by NMR. Quantitation was carried out by the method of internal standard. (13-cis) Astaxanthin (70 microg/g), 542 microg/g (all-E) astaxanthin, 36 microg/g unidentified astaxanthin isomer, 62 microg/g (9-cis) astaxanthin, and 7842 microg/g astaxanthin fatty acid esters were found.  相似文献   

4.
Three analytical methods have been developed and compared for the quality control of a new formulation (Soymen GN(R) capsules) containing soy extract and melatonin for the treatment of menopausal symptoms. The first method is based on MEKC with diode-array detection, using a mixture of basic carbonate buffer (95%) and methanol (5%), containing 55 mM SDS, as the BGE. The second method is an HPLC method with UV detection at 260 nm. The third method is an HPLC method coupled to amperometric detection which is carried out at an oxidation potential of +0.8 V. In both HPLC systems, the chromatographic separation is obtained on an RP C18 column using a mixture of ACN and an acidic phosphate buffer (25:75 v/v) as the mobile phase. A feasible pretreatment procedure with a methanol/water mixture has been implemented to achieve the quantitative extraction of the main soy isoflavones and of melatonin from the capsules. The results obtained with the three methods are in good agreement with each other and satisfactory in terms of linearity (r(2) >0.9996), precision (RSD <5.4%) and accuracy (recovery >97%). Thus, each of the three analytical methods seems to be suitable for the simultaneous analysis of the main soy isoflavones and melatonin in the new commercial formulation.  相似文献   

5.
A simple and rapid preparative high-performance liquid chromatography (HPLC) method has been developed to isolate and characterize some minor impurities of astaxanthin using a normal-phase Lichrosorb silica column with n-hexane-acetone-tetrahydrofuran (90:2:8, v/v/v) as mobile-phase and detection at 475 nm. The isolated impurities were characterized as astacene, dehydro astacene and apoastaxanthinal by UV-vis, ESI-MS, 1H and 13C NMR spectroscopy and the molecular structures were assigned. The impurities collected using the developed conditions were over 98% pure.  相似文献   

6.
张华  杨鑫  马莺  董爱军  张英春 《色谱》2008,26(3):392-394
建立了一种同时测定饲料中角黄素和虾青素的固相萃取-高效液相色谱法(HPLC)。样品由乙腈提取,经LC-NH2固相萃取小柱净 化,洗脱剂为乙腈-甲苯(体积比为3∶1),洗脱液被浓缩后进行HPLC分析,色谱柱为ZORBAX Eclipse XDB-C18柱(150 mm×4.6 mm,5 μ m),流动相为乙腈-甲醇(体积比为95∶5),流速1.0 mL/min,采用二极管阵列检测器检测,检测波长为474 nm;外标法定量。角黄素和 虾青素的线性范围分别为1.0~30.0 mg/L和1.0~20.0 mg/L,相关系数分别为0.9990和0.9991,回收率为90%~101%,相对标准偏差为 0.62%~3.68%,检出限分别为0.84和0.60 mg/L。该方法简便、快速、准确,可用于饲料中角黄素和虾青素的同时测定。  相似文献   

7.
A simple and specific high-performance liquid chromatography (HPLC) method was developed for the pharmacokinetic study of vitexin-4″-O-glucoside (VOG) in rats after oral administration. The plasma samples were deproteinised with methanol after the addition of an internal standard, hesperidin. HPLC analysis was performed on a Diamonsil C(18) analytical column, using methanol -0.5% aqueous phosphoric acid (45:55, v/v) as the mobile phase with ultraviolet detection at 330?nm. The calibration curve was linear over the range of 5-450?μg?mL(-1) in rat plasma. The average extraction recovery of VOG was 98.74%?±?0.44%, and the relative standard deviations of the intra- and inter-day precisions were not greater than 4.1% and 2.0%, respectively. The validated method was successfully applied during a pharmacokinetic study in rats after oral administration of VOG at different doses, and all the results indicated that the pharmacokinetics of VOG in rats obeyed nonlinear processes.  相似文献   

8.
A reproducible and fast method has been developed for the assay of cyclandelate in bulk and drug forms using packed column supercritical fluid chromatography using dicyclohexyl phthalate (DCHP) as internal standard. The drug and the internal standard were resolved by elution with supercritical fluid carbon dioxide doped with 14.29% (v/v) methanol on an RP-C18 column and detected spectrophotometrically at 228 nm. Chromatographic figures of merit using C8, C18, cyano and phenyl columns have been assessed. Parallel experiments have been performed by HPLC and the data have been compared. Supercritical fluid extraction using CO2 modified with a small amount of methanol was found to give quantitative analytical recoveries of cyclandelate from a dosage form. SFC has been shown to be a viable, faster alternative technique to HPLC generating less disposable waste. Received: 20 June 1997 / Revised: 20 October 1997 / Accepted: 26 October 1997  相似文献   

9.
An analytical method based on high-performance liquid chromatographic (HPLC) with ultraviolet (UV) detection was developed for determination of scopolin in rat plasma using aesculin as internal standard (IS). After protein precipitation of plasma sample with methanol, the supernatant was directly injected and analyzed. Chromatographic separation was achieved on a C18 column using methanol and distilled water (22:78, v/v) containing 0.2% (v/v) glacial acetic acid as mobile phase with a column temperature of 30 degrees C. The UV detector was set at 338 nm. The calibration curve was linear over the range of 0.105-13.125 microg/mL with a correlation coefficient of 0.9998. The retention times of aesculin and scopolin were 10.4 and 12.8 min, respectively. The recoveries for plasma samples of 0.105, 4.725 and 13.125 microg/mL were 91.08, 95.30 and 96.10%, respectively. The RSD of intra- and inter-day assay variations was less than 7.35%. The lower limit of detection was 0.03 microg/mL .This HPLC assay is a simple, sensitive and accurate and was successfully applied to the pharmacokinetic study of scopolin in rats.  相似文献   

10.
A highly selective, convenient, and precise method, first-order derivative spectrophotometry, was applied for the determination of astaxanthin in Haematococcus pluvialis. Ethyl acetate and ethanol (1:1, v/v) were found to be the best extraction solvent tested due to their high efficiency and low toxicity compared with nine other organic solvents. Astaxanthin coexisting with chlorophyll and beta-carotene was analyzed by first-order derivative spectrophotometry in order to optimize the conditions for the determination of astaxanthin. The results show that when detected at 432 nm, the interfering substances could be eliminated. The dynamic linear range was 2.0-8.0 microg/mL, with a correlation coefficient of 0.9916. The detection threshold was 0.41 microg/mL. The RSD for the determination of astaxanthin was in the range of 0.01-0.06%; the results of recovery test were 98.1-108.0%. The statistical analysis between first-order derivative spectrophotometry and HPLC by T-testing did not exceed their critical values, revealing no significant differences between these two methods. It was proved that first-order derivative spectrophotometry is a rapid and convenient method for the determination of astaxanthin in H. pluvialis that can eliminate the negative effect resulting from the coexistence of astaxanthin with chlorophyll and beta-carotene.  相似文献   

11.
A new high-performance liquid chromatographic (HPLC) method with fluorescence detection is described for the direct determination of four serum 17-oxosteroid sulphates. Each serum sample was deproteinated with methanol, the methanol was evaporated and 17-oxosteroid sulphates in the residue were extracted with benzene as ion pairs in the presence of tetrapentylammonium ion. The ion pairs were labelled with dansylhydrazine and the hydrazones were separated by HPLC on a Capcell-Pak C8 (silicone polymer-coated silica gel modified with octyl groups) reversed-phase column using methanol-0.5% (w/v) sodium acetate-50% (v/v) acetic acid (57:42:1, v/v/v) as the mobile phase. The eluent was monitored with a fluorometric detector at an excitation wavelength of 330 nm and an emission wavelength of 540 nm.  相似文献   

12.
In this work an analytical method for the determination of abamectin residues in avocados is developed using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A pre-column derivatization with trifluoroacetic anhydride (TFAA) and N-methylimidazole (NMIM) was carried out. The mobile phase consisted of water, methanol and acetonitrile (5:47.5:47.5 v/v/v) and was pumped at a rate of 1 mL/min (isocratic elution). The fluorescence detector was set at an excitation wavelength of 365 nm and an emission wavelength of 470 nm. Homogenized avocado samples were extracted twice with acetonitrile:water 8:2 (v/v) and cleaned using C(18) solid-phase extraction (SPE) cartridges. Recovery values were in the range 87-98% with RSD values lower than 13%. The limits of detection (LODs) and quantification (LOQs) of the whole method were 0.001 and 0.003 mg/kg, respectively. These values are lower than the maximum residue limit (MRL) established by the European Union (EU) and the Spanish legislation in avocado samples.  相似文献   

13.
A rapid and simple reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of clobazam concentrations in human blood samples is developed and validated. Solid-phase column extraction is performed to clean up blood samples before running the analytical HPLC system. The chromatography is isocratic with a mobile phase consisting of acetonitrile (20%, v/v), methanol (23%, v/v), and 0.1 M potassium hydrogen phosphate buffer (pH 3.6; 57%, v/v) at a constant flow rate of 2 mL/min. Clobazam is detected at 226 nm. Chromatography is completed within less than 25 min. The recovery rate is greater than 95% and linear over a wide range of drug concentrations. The intra-assay coefficient of variation percentage varies between 4.3 and 12. This method is used for therapeutic drug monitoring in patients undergoing antiepileptic therapy with clobazam. Plasma levels of clobazam ranged from 21 to 663 ng/mL. Other antiepileptic compounds, such as clonazepam and phenobarbital, did not interfere with the detection of clobazam.  相似文献   

14.
Atrasentan is an endothelin antagonist selective for the ET(A) receptor in development at Abbott Laboratories for the treatment of cardiovascular disease and cell proliferation disorders. A simple and sensitive chromatographic method for the determination of atrasentan in human plasma has been developed and validated. The analytical method involves acidification of the plasma samples with 0.3 N HCl prior to extraction with 1:1 (v:v) hexane/tert-butylmethylether. The organic extract was evaporated to dryness, reconstituted with 20:80 (v:v) acetonitrile/0.05 M K(2)HPO(4) and washed with 75:25 (v:v) hexane/tert-butylmethylether. The organic layer was discarded and the aqueous layer was injected into the HPLC. Atrasentan and internal standard (ABT-790) were separated from interference using a 250 x 4.6 mm, 5 microm, 120 A Phenomenex Spherisorb C(8) analytical column with a 50 x 4.6 mm, Alltech Absorbosphere 5 microm CN guard cartridge using a mobile phase consisting of 25:15:5:55 (v:v:v:v) acetonitrile/isopropanol/methanol/0.05 M K(2)HPO(4), pH 7.0, at a flow rate of 1.0 mL/min. Fluorescence detection was achieved using lambda(ex) 278 nm and lambda(em) 322 nm. For a 1.0 mL plasma sample volume, the limit of quantitation was approximately 200 pg/mL. The method was linear from 0.2 to 1300 ng/mL (r(2) = 0.9986). Inter- and intra-day assay RSD (n = 6) were less than 10%. Mean accuracy determinations showed the quality control samples to range between 94 and 99% of the theoretical concentration.  相似文献   

15.
Two sensitive and reproducible methods are described for the quantitative determination of itopride hydrochloride (IH) in the presence of its degradation products. The first method is based on HPLC separation on a reversed phase Kromasil column [C18 (5-microm, 25 cm x 4.6 mm, ID)] at ambient temperature using a mobile phase consisting of methanol and water (70:30, v/v) adjusted to pH 4.0 with orthophosphoric acid with UV detection at 258 nm. The flow rate was 1.0 mL per min with an average operating pressure of 180 kg/cm2. The second method is based on HPTLC separation on silica gel 60 F254 using toluene:methanol:chloroform:10% ammonia (5.0:3.0:6.0:0.1, v/v/v/v) as mobile phase at 270 nm. The analysis of variance (ANOVA) and Student's t-test were applied to correlate the results of IH determination in dosage form by means of HPLC and HPTLC methods. The drug was subjected to acid and alkali hydrolysis, oxidation, dry heat, wet heat treatment, UV, and photodegradation. The proposed HPLC method was utilized to investigate the kinetics of the acidic, alkaline, and oxidative degradation processes at different temperatures and the apparent pseudo-first-order rate constant, half-life, and activation energy were calculated. In addition the pH-rate profile of degradation of IH in constant ionic strength buffer solutions in the pH range 2-11 was studied.  相似文献   

16.
高效液相色谱法测定土壤中香豆素类灭鼠药残留   总被引:1,自引:0,他引:1  
建立了测定土壤中杀鼠灵、杀鼠醚、溴敌隆、氟鼠灵、溴鼠隆5种香豆素类灭鼠药残留量的柱后衍生荧光检测高效液相色谱方法。样品在加入内标物氯杀鼠灵后用丙酮-氨水-甲醇(体积比为100:3:100)混合液提取,浓缩的提取液用5 mL正己烷-氯仿(体积比为3:1)混合液溶解,NH2固相萃取小柱净化,用15 mL 50 mmol/L四丁基磷酸二氢铵甲醇溶液洗脱分析物,移除溶剂,用甲醇-0.25%(体积分数)乙酸水溶液(体积比为3:2)混合液溶解,过滤后,经高效液相色谱分离,以甲醇-氨水-水(体积比为1:1:8)混合液为衍生试剂进行柱后衍生,采用荧光检测器检测。杀鼠灵、杀鼠醚、溴敌隆、氟鼠灵、溴鼠隆5种鼠药在0.02~10.00 mg/L范围内线性关系良好,相关系数均大于0.999,定量限(LOQ,S/N=10)为2.2~18.5 μg/L。在0.1~0.3 mg/kg添加水平内,5种灭鼠药的回收率为94.6%~118.0%,相对标准偏差(RSD)为0.8%~10.2% (n=3)。实验结果表明该方法灵敏、准确,重复性好。  相似文献   

17.
A new molecularly imprinted solid-phase extraction(MISPE) monolithic cartridge was synthesized, and MISPE-DLLME(DLLME=dispersive liquid-liquid microextraction) was developed for purification of astaxanthin in shrimp waste. The eluent(methanol) from MISPE was used as the dispersive solvent in subsequent DLLME for further purifying and enriching the analyte prior to high-performance liquid chromatography(HPLC) analysis. The mobile phase was methanol-acetonitrile-water-dichloromethane(85:5:5:5, volume ratio), flow rate was 0.7 mL/min and UV wavelength was 476 nm. Under optimal conditions, good linearity was obtained in a range of 0.2―200.0 μg/mL(r2=0.9998) with a limit of detection(LOD) of 0.08 μg/mL, and the extraction recoveries at three spiked levels ranged from 88.3%―92.5% with a relative standard deviation(RSD) less than 4.3%. Moreover, the mean contents of astaxanthin in the three batches of shrimp waste were 95.9, 85.4 and 77.2 μg/g, respectively. This method combining the advantages of MISPE and DLLME results in high selectivity and low cost, which was applied to determining the astaxanthin level in shrimp waste samples.  相似文献   

18.
Nowadays, there is increasing interest in natural antioxidants from food by‐products. Astaxanthin is a potent antioxidant and one of the major carotenoids in crustaceans and salmonids. An ultra‐high pressure liquid chromatographic method was developed and validated for the determination of astaxanthin in shrimp by‐products, and its migration from new packaging materials to food simulants was also studied. The method uses an UPLC® BEH guard‐column (2.1 × 5 mm, 1.7 µm particle size) and an UPLC® BEH analytical column (2.1 × 50 mm, 1.7 µm particle size). Chromatographic separation was achieved using a programmed gradient mobile phase consisting of (A) acetonitrile–methanol (containing 0.05 m ammonium acetate)–dichloromethane (75:20:5, v/v/v) and (B) ultrapure water. This method was evaluated with respect to validation parameters such as linearity, precision, limit of detection, limit of quantification and recovery. Low‐density polyethylene films were prepared with different amounts of the lipid fraction of fermented shrimp waste by extrusion, and migration was evaluated into food simulants (isooctane and ethanol 95%, v/v). Migration was not detected under the tested conditions. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
4-(2-Pyridylazo) resorcinol (PAR) and citrate were used as pre-column complexing agents for the determination of Nb(V) and Ta(V) as ternary complexes in geological samples. Aliquots of 2 ml of the standard and sample solutions containing the Nb(V) and Ta(V) complexes were loaded onto a concentrator column (C18, 0.4 cm x 4.6 mm) with a carrier mobile phase comprising 20% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 10 mM tetrabutylammonium bromide (TBABr), pH 6.5 at 2 ml/min for 2 min, with the effluent being directed to waste. An automatic switching valve was then switched to flush both complexes from the concentrator column onto a C18 analytical column using a mobile phase comprising 32% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 3 mM TBABr, pH 6.5 for 2.5 min. The switching valve was then switched back to the original position, and cleaned with methanol for 7 min to eliminate unwanted species still adsorbed to the concentrator column. This procedure prevented later eluting compounds from reaching the analytical column, which reduced the overall run time. The detection limits of Nb(V) and Ta(V) (determined at a signal-to-noise ratio of 3, detection wavelength of 540 nm and a 2-ml sample volume) were 0.012 and 0.039 ppb for Nb(V) and Ta(V), respectively. Recoveries of Nb(V) and Ta(V) were 99.4 and 96.2%, respectively. The HPLC results obtained from the reference granite and basalt samples agreed well with inductively coupled plasma MS and certified values, but the HPLC method yielded slightly low values of the Nb/Ta ratio.  相似文献   

20.
A high-performance liquid chromatographic method for the determination of wogonoside in plasma of rats administrated orally with the traditional Chinese medicinal preparation Huang-Lian-Jie-Du decoction was developed. Sample preparation was carried out by protein precipitation with a mixture of acetonitrile and methanol (1:1, v/v). The extracted sample was separated on a Hypersil C(18) (150 x 5 mm i.d., 5 microm) analytical column by linear gradient elution using 0.05% (v/v) phosphoric acid (containing 5 mm sodium dihydrogen phosphate) and acetonitrile as mobile phase at a flow rate of 1.5 mL/min. The eluate was detected using a UV detector at 276 nm. The assay was linear over the range 0.109-7.0 microg/mL (R(2) = 0.9999, n = 5). Mean recovery was determined as 98.39%. Intra- and inter-day precisions (RSD) were < or =7.59%. The limit of quantitation was 0.109 microg/mL. After validation, the HPLC method developed was applied to investigate the preliminary pharmacokinetics of wogonoside in rat after oral administration of Huang-Lian-Jie-Du decoction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号