首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
In the present study, baseline separation of the enantiomers of 16 β-carboline derivatives was successfully achieved using both capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) techniques in short run times (<15?min) and thus permit the determination of enantiomeric excess. In HPLC methodology, cellulose chiral stationary phase (Chiralcel OD-H) was used with a binary mobile phase constituted of n-hexane/ethanol 85/15 leading to a resolution factor of 12.6 in 15?min. Preparative HPLC allowed to obtain pure enantiomers of two compounds. In CE, chiral selectivity was developed with an in-capillary stacking strategy using anionic (highly sulfated-γ) cyclodextrins 5% (w/v) as chiral selectors and a 60?mM phosphate buffer (pH 2.5) resulting in a resolution of 10.26 in 14?min of analysis. The analytical characteristics of the two developed methods were studied in terms of repeatability, limits of detection and limits of quantification showing their suitability to be extended to all the other molecules.  相似文献   

2.
The electrophoretic separation of ribavirin and 5-methylcytidine (internal standard) by capillary electrophoresis was examined. Separation was achieved using reverse polarity in a 100 mM borate electrolyte, pH 9.1, with 5 mM spermine added to reduce the electroosmotic flow. Sample preparation based on acetonitrile protein precipitation was found to be unsuitable for ribavirin analysis in patient samples due to insufficient sensitivity and interferences. Solid-phase extraction employing phenyl boronic acid cartridges provided cleaner separations. Using this approach with 500 microL sample and reconstitution of the dried extract into 100 microL of 33% v/v 100 mM phosphate buffer, pH 6.4 / 67% v/v acetonitrile, the detection and quantitation limits were determined to be 0.05 and 0.10 microg/mL, respectively, a sensitivity that is suitable for therapeutic drug monitoring of ribavirin in human plasma and serum samples. The method was validated and compared to a high-performance liquid chromatography (HPLC) method, showing excellent agreement between the two for a set of samples that stemmed from patients being treated with ribavirin and interferon-alpha-2b for a hepatitis C virus infection.  相似文献   

3.
In this work the suitability of micellar electrokinetic capillary chromatography (MEKC) and nonaqueous capillary electrophoresis (CE) to the analysis of the primary oxidation products of linoleic acid was studied with uncoated fused-silica capillaries. The primary autoxidation products of linoleic acid are the four hydroperoxide isomers 13-hydroperoxy-cis-9, trans-11-octadecadienoic acid, 13-hydroperoxy-trans-9, trans-11-octadecadienoic acid, 9-hydroperoxy-trans-10,cis-12-octadecadienoic acid, 9-hydroperoxy-trans-10, trans-12-octadecadienoic acid. Addition of a surfactant such as sodium dodecyl sulfate (SDS) or sodium cholate (SC) into the running buffer (20-30 mM 3-(cyclohexylamino)-1-propanesulfonic acid (CAPS) or ammonium acetate, pH 9.5-11) was required to enhance the water solubility of the sample and selectivity of the separation. MEKC proved to be a promising new technique for the separation of the primary oxidation products of lipids giving results comparable to high performance liquid chromatography (HPLC). Partial separation of hydroperoxide isomers was also achieved using nonaqueous CE with methanol-acetonitrile-sodium cholate as running buffer.  相似文献   

4.
Available and total niacin content in lentils and faba beans have been analyzed by capillary electrophoresis (CE), and the results compared with those obtained by high performance liquid chromatography (HPLC). Acidic and enzymatic hydrolysis have been carried out for available niacin determination, and an alkaline extraction performed for total niacin. The extracts were subsequently purified using a strong anion exchanger resin. Precise conditions for purification had to be worked out for each one of the two analytical methods (HPLC and CE). The HPLC analysis for available and total niacin was carried out in an ion-pair reverse phase column with UV detection at 261 nm. For the CE separation, the following conditions were employed: a 20 mM sodium tetraborate; 15 mM sodium dodecyl sulfate and 20% isopropyl alcohol solution as separation buffer; 30 kV and 25 or 30°C. Separation was carried out in a 70 cm effective length × 75 μm i.d. fused-silica capillary using on-column UV detection at 254 nm. The results obtained by CE for lentils and faba beans were similar to those obtained by HPLC.  相似文献   

5.
The separation of three selective serotonin reuptake inhibitors (SSRIs) by capillary electrophoresis (CE) with fully integrated solid-phase extraction (SPE) is described. Polymeric monolithic SPE modules were prepared in situ within a fused silica capillary from either butyl methacrylate-co-ethylene dimethacrylate or 3-sulfopropyl methacrylate-co-butyl methacrylate-co-ethylene dimethacrylate. Using a 1 cm SPE module placed at the inlet of the capillary, a mixture of sertraline, fluoxetine and fluvoxamine was extracted from aqueous solution by applying a simple pressure rinse. Under pressure-driven conditions, efficient elution was possible from both SPE materials investigated using 50 mM phosphate buffer, pH 3.5 in acetonitrile (20/80, v/v). Two different strategies were investigated for the efficient elution and subsequent CE separation. Injection of an aqueous sample plug directly into the non-aqueous elution/separation buffer was found to be unsuitable with poor elution profiles observed in the electrodriven mode. Alternatively, a sample plug equivalent to several capillary volumes could be injected by pressure followed by filling the capillary with the non-aqueous elution/separation buffer from the outlet end using a combination of pressure and electrodriven flow. Using a neutral monolith, efficient elution/separation was not possible due to an unstable electroosmotic flow (EOF), however, by adding the ionisable monomer, 3-sulfopropyl methacrylate to the SPE module to increase and stabilise the EOF, it was possible to achieve efficient elution from the SPE module, followed by baseline separation by CE using a 200 mM acetate buffer, pH 3.5 in acetonitrile (10/90, v/v). With enrichment factors of over 500 achieved for each of the analytes this demonstrates the potential of in-line SPE-CE for the sensitive analysis of these drugs.  相似文献   

6.
The separation and determination of twelve anthraquinones, viz. anthraquinone 1, chrysphanol 2, aloe‐emodin 3, alizarin 4, anthraquinone‐2‐carboxylic acid 5, purpurin 6, sennoside B 7, sennoside A 8, emodin 9, quinalizarin 10, rhein 11, and anthraflavic acid 12, were achieved by capillary electrophoresis (CE) and high‐performance liquid chromatography (HPLC). Detection at 260 nm with a buffer solution containing 30 mM sodium borate (adjusted to pH = 10.56 with 0.05N NaOH) and acetonitrile (9 : 1) in CE or with a linear gradient elution containing 20 mM KH2PO4 with 0.05% phosphoric acid (pH = 2.91) and methanol in HPLC was found to be the most suitable approach for this separation. Contents of six components (2, 3, 7, 8, 9, 11) in crude Rhei Rhizoma extract could easily be determined within 39 min by CE or 63 min by HPLC. The effects of buffers on this separation and the validation of the two methods were studied.  相似文献   

7.
Spherical molecularly imprinted polymer particles obtained via precipitation polymerization, were introduced as a pseudostationary phase in capillary electrophoresis (CE) to study molecular recognition. Analyses were performed via a partial filling technique using (+)-ephedrine-imprinted microspheres (100-200 nm) which were polymerized from methacrylic acid and 1,1,1-Tris(hydroxymethyl)propanetrimethacrylate using acetonitrile as the solvent. The influence of pH and the modifier content on the separation was investigated. A 0.1% w/v suspension in an aqueous 10 mM phosphate buffer (pH 2.5 with 40% acetonitrile) was hydrodynamically injected into the CE system (80% of the effective capillary length) and led to full baseline separation of racemic ephedrine within 10 min.  相似文献   

8.
The quantitation of thiopental in human serum and plasma was investigated using high-performance capillary electrophoresis (HPCE) in a micellar configuration and the results were compared with reversed-phase high-performance liquid chromatography (HPLC). Thiopental and an internal standard (carbamazepine for HPCE and thiamylal for HPLC) were extracted from serum or plasma using pentane and a phosphate buffer (pH 6.4). HPCE analysis took place in a phosphate-borate buffer with 50 mM sodium dodecyl sulphate using an automated instrument and HPLC was performed with a C8 column and a mobile phase of phosphate buffer-acetonitrile (65:35, v/v). HPCE and HPLC data from 66 patient samples compared well based on linear regression analysis. However, estimates obtained with the inclusion of the internal standard were lower than those based on the sample peak only. This example allows the elucidation of the advantages of using HPCE as an assay methodology for the therapeutic monitoring of thiopental and other drugs.  相似文献   

9.
Quantitation of nicotine in tobacco products by capillary electrophoresis   总被引:3,自引:0,他引:3  
A simple and rapid capillary electrophoresis (CE) method was developed for the quantitation of nicotine in commercial tobacco products. The method involves a 6 min run at 30 kV, using a 50 mM phosphate buffer (pH 2.5), paraquat as internal standard, and UV detection at 260 nm. Nicotine was extracted from tobacco products in <15 min. Recoveries from spiked extracts were >95%, and the extraction efficiencies of water, 1 M HCI, 1 M acetic acid, 5 mM phosphate buffer (pH 2.5), and 1% triethanol amine were similar. Nicotine concentrations in 67 samples of cigarettes, cigars, and bidis varied between 0.37 and 2.96% (w/w). An established gas chromatography/mass spectrometry method using toluene extraction consistently yielded lower nicotine values than the CE method. Experimental evidence suggests that this is due to insufficient extraction of nicotine by toluene.  相似文献   

10.
Systems for efficient separation of selected alkaloid groups by high performance liquid chromatography (HPLC), capillary electrophoresis (CE) and capillary electrophoresis coupled with electrospray ionisation mass spectrometry (CE-ESI-MS) are described. The optimized HPLC system was applied for the separation of 23 standard indole alkaloids as well as for qualitative and quantitative analyses of crude alkaloid extracts of Rauvolfia serpentina X Rhazya stricta hybrid cell cultures. The developed conditions for CE analysis proved to be efficient for separation of mixtures of standard indole and beta-carboline alkaloids. The described buffer system is also applicable in the combination of CE with electrospray ionisation mass spectrometry. This analytical technique allowed the separation and identification of components of standard indole alkaloid mixture as well as crude extracts of R. serpentina roots, R. serpentina cell suspension cultures and cortex of Aspidosperma quebracho-blanco. The influence of buffer composition and analyte structures on separation is discussed.  相似文献   

11.
《Analytica chimica acta》2004,503(2):271-278
In this work, a capillary electrophoresis (CE) method for the determination of a group of eleven triazine compounds by micellar electrokinetic capillary chromatography (MEKC) with diode array detection was developed. The eleven herbicides studied were: desethylatrazin-2-hydroxy (DEA), simazine, prometon, atrazine, simetryn, ametryn, propazine, prometryn, trietazine, terbutylazine, and terbutryn The separation of these compounds was optimised as a function of buffer concentration and pH, concentration of sodium dodecyl sulphate (SDS) and voltage applied. To increase the selectivity of the separation and the resolution of the solutes, different organic solvents were tested as buffer additives, obtaining the best results when 1-propanol was used. The optimised buffer (24 mM of sodium borate, 18 mM of disodium hydrogen phosphate, 25 mM of SDS, pH 9.5, and 5% of 1-propanol) provides the best separation in terms of resolution and migration time. This method allowed the determination of these compounds at concentrations of 0.05 μg l−1 in ground water samples pretreated using solid-phase extraction (SPE).  相似文献   

12.
A novel chiral selector, clindamycin succinate, was synthesized and first used as a chiral selector in capillary electrophoresis (CE). The chiral resolution ability of this kind of clindamycin derivation was studied by CE using some racemic drugs as model analytes. From the experimental results, it was found that both resolution and selectivity of the selector were dependent on the following parameters: concentration of chiral selectors, pH of the running buffer, temperature of the capillary column, applied voltage and organic modifier used. The results show that the chiral selector possesses high resolution toward some racemic drugs, including ofloxacin, chlorphenamine, tryptophan, propranolol, sotalol and metoprolol. Excellent chiral resolution of these tested drugs was achieved under the optimal conditions of 50 mM clindamycin succinate, 10% MeOH v/v, 50 mM Tris buffer, pH 4.0, at 22 kV and 20 °C within 25 min.  相似文献   

13.
This study demonstrates the separation of cold medicine ingredients (e.g., phenylpropanolamine, dextromethorphan, chlorpheniramine maleate, and paracetamol) by capillary zone electrophoresis and micellar electrokinetic chromatography. Factors affecting their separations were the buffer pH and the concentrations of buffer, surfactant and organic modifiers. Optimum results were obtained with a 10 mM sodium dihydrogen-phosphate-sodium tetraborate buffer containing 50 mM sodium dodecyl sulfate (SDS) and 5% methanol (MeOH), pH 9.0. The carrier electrolyte gave a baseline separation of phenylpropanolamine, dextromethorphan, chlorpheniramine maleate, and paracetamol with a resolution of 1.2, and the total migration time was 11.38 min.  相似文献   

14.
A capillary electrophoresis (CE) and a high performance liquid chromatography (HPLC) method are described for the simultaneous determination of ethylenediaminetetraacetic acid (EDTA), S,S′-ethylenediaminedisuccinic acid (EDDS) and R,S-iminodisuccinic acid (IDS) complexing agents as their Fe(III) complexes in cosmetics like shower cream and foam bath. The non-biodegradable EDTA is used in combination with biodegradable analogues like EDDS and IDS in many commercial products. The HPLC method involves separation by reversed-phase ion pair chromatography on a C18 column using methanol-formate buffer (20 mM tetrabutylammonium hydrogen sulfate, 15 mM sodium formate adjusted to pH 4.0 with formic acid) (10:90, v/v) as mobile solvent at a flow rate of 0.8 mL min−1 at 24 °C using UV detection at 240 nm. The CE separation was performed in a fused silica capillary of 50 μm i.d. with the total length of 50 cm with a 10 mM MES and MOPSO (pH 5.5) at an applied voltage of −25 kV. The samples were introduced by applying a 50 mbar pressure for 2 s. Absorbances at 215 and 225 nm were monitored for the detection of the complexes. The methodology performance of the two methods was evaluated in terms of linearity, limit of detection (LOD), limit of quantitation (LOQ) and reproducibility. The LOD values obtained from HPLC are low when compared with CE. The applicability of both the methods was demonstrated for the analysis of cosmetic products such as shower cream and foam bath. The results obtained by both CE and HPLC were found to be comparable and in good agreement.  相似文献   

15.
A rapid and simple method is presented for the determination of folic acid (FA) by capillary electrophoresis (CE) with chemiluminescence (CL) detection. This method was based on enhance effect of FA on the CL reaction between luminol and BrO(-) in alkaline aqueous solution. Optimal separation and determination was obtained with an electrophoretic buffer of 35 mM sodium borate (pH 9.4) containing 0.8 mM luminol, and an oxidizer solution of 1.6 mM NaBrO in 100 mM NaCO(3) buffer solution (pH 12.0). Under the optimal conditions, the determination of FA was achieved in less than 20 min, and the detection limit was 2.0 x 10(-8) M (S/N=3). The relative standard deviations (RSDs) on peak area and migration time were in the 1.5 and 1.1%, respectively. The present CE-CL method was applied to the determination of FA in commercial pharmaceutical tablets, apple juices and human urine.  相似文献   

16.
Capillary electrophoresis (CE) was applied to analyse the long-chain fatty acid composition of vegetable oils, and their degradation products formed upon ageing when drying oils are used as binding media. The analytes were detected with contactless conductivity detection (CCD) and indirect UV absorption, both detectors positioned on-line at the separation capillary. The long-chain fatty acids were resolved in a background electrolyte (BGE) consisting of phosphate buffer (pH = 6.86, 15 mM) containing 4 mM sodium dodecylbenzensulfonate, 10 mM Brij 35, 2% (v/v) 1-octanol and 45% (v/v) acetonitrile. As in this system dicarboxylic analytes, the products of oxidative degradation of unsaturated fatty acids, cannot be determined, a suitable background electrolyte was developed by the aid of computer simulation program PeakMaster. It makes use of a 10 mM salicylic acid, 20 mM histidine buffer, pH 5.85, which combines buffering ability with the optical properties obligatory for indirect UV detection. This buffer avoids system eigenpeaks, which are often impairing the separation efficiency of the system. Separation of the dicarboxylic analytes was further improved by a counter-directed electroosmotic flow (EOF), obtained by dynamically coating the capillary wall with 0.2 mM cetyltrimethylammonium bromide. Long-chain fatty acids and their decomposition products could be determined in recent and aged samples of drying oils, respectively, and in samples taken from two paintings of the 19th century.  相似文献   

17.
A novel, rapid and continuous on-line concentration approach based on dynamic pH junction for the analysis of trimethoprim (TMP) and sulfamethoxazole (SMZ) by microfluidic capillary electrophoresis (CE) combined with flow injection analysis is developed in this paper. Stacking is due to decreases in the velocity of analytes when migrating from the low-pH sample zone (sample was dissolved in 50 mM HCl) to a relatively high-pH buffer (30 mM phosphate buffer, pH 8.5) filled in the capillary. This results in 2.9-4.7-fold improvement in concentration sensitivity relative to conventional capillary electrophoresis methods. The separation could be achieved within 2 min and sample throughput rate can reach up to 38 h(-1).  相似文献   

18.
Two methods, based on the use of capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC), respectively, were developed for the analysis of the atypical antipsychotic aripiprazole in plasma of schizophrenic patients for therapeutic drug monitoring purposes. Good analytical performances were obtained with the CE method, using uncoated fused silica capillaries and a background electrolyte composed of 50 mM phosphate buffer at pH 2.5. With 20 kV voltage, aripiprazole was detectable at 214 nm within 5 min. The second analytical method, based on HPLC with diode array detection, employed a C8 reversed-phase column and a mixture of a 12.5 mM phosphate buffer, pH 3.5, containing triethylamine and acetonitrile as the mobile phase. Aripiprazole was detected at 254 nm and a complete chromatographic run lasted about 10 min. For both analytical methods loxapine was used as the internal standard and the same plasma sample pre-treatment by means of solid-phase extraction on cyano cartridges was carried out, with extraction yield values always higher than 91.3%. Linear responses for aripiprazole were obtained between 70 and 700 ng mL−1 and precision assays (expressed as relative standard deviation values) were lower than 7.0%. After validation, both methods were successfully applied to human plasma samples drawn from schizophrenic patients undergoing therapy with Abilify® tablets. Accuracy was satisfactory, with recovery value higher than 91.0%.  相似文献   

19.
To probe separation mechanism and determination with capillary zone electrophoresis (CZE) and liquid chromatography (LC), nine compounds with identical flavanone skeleton were studied. Optimum separation of LC was attained with gradient of acetonitrile and 5mM phosphate buffer (pH 6.9). For CE, electrolyte buffer was 4.5mM SDS in 32mM sodium tetraborate buffer (pH 9.2). The distinguishing feature in this work was successful separation of monohydroxyl stereoisomers by CZE. Polarity is generally increased with hydroxyl groups. In a separation mechanism study, polarity would be reduced by intramolecular hydrogen bond between hydroxyl of C5 and carbonyl group of C4. Comparison of the retention results among monohydroxyl flavanones shows polarity with hydroxyl at C6 the least, and that at C4' and C7 nearly equal. Also, elution order of flavones and flavanones would be adverse due to the hydroxyl at C3 in LC. From the numerical value pK(a) of flavanone, the C7-OH is the smallest, and two hydroxyl groups in an adjacent position is always less than the unique one caused by forming a stable 5-membered ring. Investigation of separation mechanism yield only the effect of constituent but also reasonable explanation for contradictory results between Wulf and our laboratory, this due to the hydroxyl at C3.  相似文献   

20.
Zhang YP  Lee KP  Kim SH  Choi SH  Gopalan AI  Yuan ZB 《Electrophoresis》2004,25(16):2711-2719
Structurally related phenyl alcohols were separated by capillary electrophoresis and liquid chromatography. A statistical experimental design was used in order to optimize the main electrophoretic parameters such as pH, concentration of selector and separation voltage in capillary electrophoresis (CE). Response surfaces were derived using the mathematical model and used for a selection of the optimal experimental conditions. Concentration of the chiral selector, the distance between the aromatic group and asymmetric center of the analytes, were identified as the factors influencing the complexation, selectivity and resolution. Experiments were also performed by high-performance liquid chromatography (HPLC) and the results of CE and HPLC were compared.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号