首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Tripamide is a drug widely used in clinical practice for the treatment of hypertension and edema. This work evaluated a screening method for Tripamide and its urinary metabolites in human urine, using high-performance liquid chromatography diode-array detection (HPLC/DAD). Identification of these metabolites was investigated by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) after dosing with 15 mg Tripamide. Acid hydrolysis showed that Tripamide is conjugated in the body. Two suspected metabolites were detected by HPLC/DAD. HPLC/ESI-MS/MS analysis suggested that these metabolites were probably hydroxylated together with loss of the -NH(2) group and dehydrogenation. These results will be useful in confirmation methods for Tripamide in doping control.  相似文献   

2.
High-performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionization (APCI) mass spectrometry was used for the separation and detection of amino acid and peptide enantiomers. With detection limits as low as 250 pg, 25 amino acids enantiomers were baseline resolved on a Chirobiotic T chiral stationary phase. APCI demonstrated an order of magnitude better sensitivity over electrospray ionization (ESI) for free amino acids and low molecular mass peptides at the high LC flow-rates necessary for rapid analysis. As the peptide chain length increased (peptides with M(r) > or = 300 Da), however, ESI proved to be the more ideal atmospheric pressure ionization source. A mobile phase consisting of 1% (w/w) ammonium trifluoroacetate in methanol and 0.1% (w/w) formic acid in water increased the sensitivity of the APCI method significantly. A step gradient was then used to separate simultaneously all 19 native protein amino acid enantiomers in less than 20 min using extracted ion chromatograms.  相似文献   

3.
Five metal complex azo compounds were analyzed using negative-ion electrospray ionization mass spectrometry (ESI-MS). Mass spectra of all compounds yield intense peaks corresponding to [M - H](-) ions without any fragmentation, where M denotes the neutral compound with a proton as the counterion. Under collision induced dissociation (CID) conditions, structurally important fragment ions were studied using the ion trap analyzer with a multistage mass spectrometry (MS(n) facility. Synthesized compounds with (15)N atoms in the azo group facilitated the fragmentation pattern recognition. A reversed-phase high-performance liquid chromatography (HPLC) method using 5 mM ammonium acetate in 70% aqueous acetonitrile as mobile phase was developed making possible the separation of all complex compounds tested. The lower detection limits of the ESI-MS method are in the range 10-20 ng of each compound. The HPLC/ESI-MS method makes possible the monitoring of ligand exchange in aqueous solutions of metal complex azo dyes, and also investigation of the stabilities of the complexes in solution. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

4.
High-performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS) and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) techniques were applied for the detection, purification, monitoring, and sequencing of two novel and biologically active peptides occurring at very low levels in the venom of the wasp Agelaia pallipes pallipes. These peptides were sequenced under LC/ESI-MS/MS conditions and designated as Agelaia-CP (I/L-L-G-T-I-L-G-L-L-K-G-I/L-NH2, MW 1207.8 Da) and Agelaia-MP (I/L-N-W-L-K-L-G-K-A-I-I-D-A-I/L-NH2, MW 1565.0 Da). The peptide Agelaia-CP showed no hemolytic activity, but it behaved as a mast cell degranulator and induced a potent chemotaxis in polymorphonucleated leukocyte (PMNL) cells, typical of a wasp chemotactic peptide. The peptide Agelaia-MP showed both powerful mast cell degranulation and hemolysis of washed rat red blood cells, and is thus assigned as a new member of the mastoparan family of peptides. Both peptides seem to be directly involved in the strong inflammatory reactions associated with wasp stings.  相似文献   

5.
Paeoniflorin standard was first investigated by electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry (ESI-FTICR-MS/MS) using a sustained off-resonance irradiation (SORI) collision-induced dissociation (CID) method at high mass resolution. The experimental results demonstrated that the unambiguous elemental composition of product ions can be obtained at high mass resolution. Comparing MS/MS spectra and the experimental methods of hydrogen and deuterium exchange, the logical fragmentation pathways of paeoniflorin have been proposed. Then, the extracts of the traditional Chinese medicine Paeonia lactiflora Pall. were analyzed by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS). By comparison with the ESI-FTICR-MS/MS data of paeoniflorin, the isomers paeoniflorin and albiflorin in Paeonia lactiflora Pall. have been identified using HPLC/MS with CID in an ion trap and in-source CID. Furthermore, using the characteristic fragmentation pathways, the retention times (t(R)) in HPLC and MS/MS spectra, the structures of three other kinds of monoterpene glycoside compounds have been identified on-line without time-consuming isolation. Thus an HPLC/ESI-MS method for the analysis of constituents in Paeonia lactiflora Pall. has been established.  相似文献   

6.
Mass spectrometry (MS) and tandem mass spectrometry (MS(n)) were used for the identification of beauverolides in the fermentation broth of Beauveria bassiana and for evaluation of the purified fraction obtained by sublimation of beauverolides. Besides being a new efficient route for purification of beauverolides, sublimation provided an enrichment of new minor lipophilic beauverolides of lower molecular weight from the original complex mycelial extract. The product ion collision-induced dissociation (CID) spectra obtained on an ion trap (electrospray ionization), the in-source CID mass spectra on a sector instrument (atmospheric-pressure chemical ionization) and the post-source decay matrix-assisted laser desorption/ionization mass spectra of beauverolides were compared and evaluated. All MS(n) experiments started with singly charged precursor ions. The following two new representatives of this group of compounds were identified by high-performance liquid chromatography and MS (HPLC/MS): cyclo-(3-hydroxy-4-methyloctanoyl-valyl-alanyl-leucyl) and cyclo-(3-hydroxy-4-methyloctanoyl-tyrosyl-alanyl-leucyl). Individual structures were confirmed by preparative isolation and nuclear magnetic resonance spectroscopy. The structure of a third novel and minor beauverolide was tentatively assigned by HPLC/MS only as cyclo-(3-hydroxy-4-methyldecanoyl-valyl-alanyl-Lxx), Lxx = leucyl, isoleucyl, or allo-isoleucyl.  相似文献   

7.
Oxidation of proteins with performic acid is extensively used to cleave disulfide bonds. Due to its efficiency and many other advantages it deserves more attention especially in proteomics as a method for sample treatment. However, some unwanted degradations can occur during performic oxidation. In this work the degradation products during performic oxidation of two peptides and bovine serum albumin as model substrates were explored by coupling high-performance liquid chromatography (HPLC) to matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-TOF/TOFMS). In addition to well-known modifications such as oxidation of tryptophan and oxidation and chlorination of tyrosine, novel degradation products including nonspecific cleavage after asparagine or tryptophan, formylation of lysine, and beta-elimination of cysteine, were observed. Although almost all of these modification/degradation products except oxidation products of tryptophan were formed at sub-stoichiometric levels, they can cause confusion as a result of the sensitivity of mass spectrometry in analysis of the oxidized samples, especially in proteomics research. The results presented here will facilitate the interpretation of analytical data for performate-oxidized samples, and help to select appropriate methods for each unique sample.  相似文献   

8.
The quantitative determination of nucleotides from DNA modified by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liquid chromatography (HPLC). LC/ICP-MS (resolution > 1500 to discriminate against 15N16O+ and 14N16OH+) was employed to determine quantitatively the content of modified nucleotides in standard solutions based on the signal of phosphorus; phosphoric acid served as an internal standard. By means of the standard addition technique the sensitivity of the LC/ESI-MS approach was subsequently determined. Since a comparison of UV, ICP and ESI-MS data suggested that in ESI-MS the ionization efficiency of the adducts is identical within the error limits, quantitative determination of all adducts is possible. For LC/ESI-MS with single ion monitoring, the detection limit for styrene oxide adducts of nucleotides was determined to be 20 pg absolute or 14 modified in 10(8) unmodified nucleotides in a 5 micrograms DNA sample, which comes close to the best methods available for the detection of chemical modifications in DNA.  相似文献   

9.
High-performance liquid chromatography-diode array detection (HPLC-DAD), electrospray ionization time-of-flight mass spectrometry (HPLC-ESI-TOF-MS) and electrospray ionization quadrupole ion trap mass spectrometry (HPLC-ESI-MSn) were used for the isolation, identification and structural analysis of water-soluble phenolic and nonpolar diterpenoid constituents in Dan-shen (Radix Salvia miltiorrhizae) which was prepared by sonication in 70% methanol. Mass spectra were obtained by ESI-TOF-MS and electrospray ionization quadrupole ion trap mass spectrometry (ESI-QIT-MS). A formula database of known constituents in Dan-shen was established and most constituents were rapidly identified by HPLC-DAD/ESI-TOF-MS by matching their accurate molecular masses with the formulae of the compounds in the database. Compounds with the same molecular formula could not be differentiated by TOF-MS; however, QIT-MS could differentiate those compounds and elucidate their structures based on their characteristic fragmentation. HPLC-DAD, HPLC/ESI-TOF-MS and HPLC/ESI-MSn provided complementary information for the identification of the constituents in Dan-shen. Forty constituents were identified in 30 min based on their positive and negative ion ESI mass spectra and liquid chromatographic information. Thus the method described is useful for the rapid analysis of multiple constituents in Dan-shen.  相似文献   

10.
The photostability of guaiazulene (1,4-dimethyl-7-isopropylazulene; GA), a natural azulenic compound used in cosmetic and health-care products, as well as in pharmaceutical preparations, was investigated in solution (methanol, ethanol, acetonitrile), by different techniques: gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry and UV detection (LC/APCI-MS and HPLC/UV). A solar simulator (xenon-arc lamp) was used as UV-A radiation source. The study involved: monitoring compound decomposition, identifying products of photodegradation (PPs), assessing the role of oxygen and evaluating the kinetics of the process. Minor PPs are volatile compounds and were characterized by GC/MS, while oligomeric polyoxygenated compounds, tentatively characterized on the basis of MS and MS/MS spectra, were found to be the main photoproducts. The photodegradation was found to be enhanced by the presence of oxygen; nevertheless, determination of the singlet oxygen quantum yield for GA gave a lower value than that for the reference standard Rose Bengal. The obtained results and the developed stability-indicating methods (GC/MS and LC/MS) are of interest for stability studies and/or quality control purposes of GA as raw material or cosmetic products.  相似文献   

11.
A new method providing enhanced sensitivity for the analysis of oligonucleotides using an on-line coupled system of reversed-phase high-performance liquid chromatography (RP-HPLC) and electrospray ionization ion-trap mass spectrometry (ESI-MS) has been developed. The presented method allows the use of the standard gradient elution of 0.1 M triethylammonium acetate (TEAA) buffer (adjusted to pH 7.0 with acetic acid) and acetonitrile that is typically used for the separation of oligonucleotides in RP-HPLC. An added feature of this method is the ability to combine and mix additional 0.1 M imidazole in acetonitrile after the separation column for improved ESI-MS performance. This is similar to the post-column reaction method in liquid chromatography (LC) and the liquid sheath flow method in LC/ESI-MS, both of which offer the advantage of not compromising the chromatographic separation conditions. The application of this new method is demonstrated to afford improved sensitivity for the analysis of oligonucleotides (20-50 mer) via on-line coupled HPLC/ESI-MS analysis and purification systems.  相似文献   

12.
Summary This study demonstrated the utility of high-performance liquid chromatography/atmospheric pressure ionization mass spectrometry (HPLC/API-MS) in the investigation of 10-methoxy-1,6-dimethylergoline-8-methanol 5-bromonicotinic acid ester (Nicergoline) and its related substances. The analysis was performed by using an ODS column with ammonium acetate and methanol mixture as the mobile phase. Nicergoline and its related compounds could be characterized by HPLC/API-MS in terms of their molecular weight. The use of multiple ion detection techniques for the quantitation of these compounds was also investigated. The detection limits of nicergoline and its related substances were 5 to 10 ng each at a signal-to-noise ratio of 4. The method was also applied to the study of the decomposition products of nicergoline in simulated gastric and intestinal fluids.  相似文献   

13.
A rapid on-line method for the identification of phosphorylated peptides in enzymatic protein digests by specific marker ion signals is described. In our study we investigated the use of alkaline conditions together with a previously described method for selective and sensitive detection of phosphopeptide ions combining high-performance capillary liquid chromatography (LC) and electrospray ionization mass spectrometry (ESI-MS). Phosphorylation-specific marker ions (m/z 79, PO(3)(-), and m/z 97, H(2)PO(4)(-)) were generated by skimmer collision-induced dissociation (sCID) in the negative-ion mode. The method was evaluated and validated for mono-phosphorylated synthetic peptides using different alkaline pH values and CID offsets. Alkaline conditions (pH 10.5) enhance the generation of phosphopeptide-specific fragment ions from serine- and tyrosine-phosphorylated peptides, and enable the use of m/z 79 (PO(3)(-)) and m/z 97 (H(2)PO(4)(-)) as phosphorylation-specific marker traces. Note that HPLC separation in trifluoroacetic acid containing solvents impairs the use of m/z 97 (C(2)F(3)O(-) fragment ion at m/z 97) as a phosphorylation-specific marker. The optimized method was applied for the detection of phosphorylated peptides in a tryptic beta-casein digest. The expected mono- and tetra-phosphorylated peptides were detected and rapidly identified by (mu)LC/ESI-sCID-MS and (mu)LC/ESI-MS analysis.  相似文献   

14.
Here we report the first application of a matrix-assisted laser desorption/ionization (MALDI) triple-quadrupole mass spectrometer for targeted proteomics. Employing an amine-specific isotopic labelling approach, the technique was validated using five randomly selected bovine serum albumin peptides differentially labelled at known ratios. An indirect benefit of the isotopic labelling technique is a significant enhancement of the a1 ion in tandem mass (MS/MS) spectra of all peptides studied. Therefore, the a1 ion was selected as the fragment ion for multiple reaction monitoring (MRM) in all cases, eliminating tedious method development and optimization. Accurate quantification was achieved with an average relative standard deviation (RSD) of 5% (n = 5) and a detection limit of 14 amol. The technique was then applied to validate an important virulence biomarker of the fungal pathogen Candida albicans, which was not accurately quantified using global proteomics experiment employing two-dimensional liquid chromatography/electrospray ionization tandem mass spectrometry (2D-LC/ESI)-MS/MS. Using LC/MALDI-MRM analysis of five tryptic peptides, the protein PHR1 was found to be upregulated in the hyphal (pathogenic) form of C. albicans by a factor of 7.7 +/- 0.8.  相似文献   

15.
The relative reactivities of various naphthoquinone isomers (1,4-, 1,2- and 2-methyl-1,4-naphthoquinone) to two test proteins, apomyoglobin and human hemoglobin, were evaluated via liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS). The structural characterization of the resulting adducts was also obtained by LC/ESI-MS analysis of the intact proteins. The reactive sites of apomyoglobin and human hemoglobin with 1,4-naphthoquinone and 1,2-naphthoquinone were also identified through characterization of adducted tryptic peptides by use of high-pressure liquid chromatography/electrospray ionization with tandem mass spectrometry (HPLC/ESI-MS/MS), TurboSEQUEST, and the scoring algorithm for spectral analysis (SALSA). Four adducted peptides, which were formed by nucleophilic addition of a lysine amino acid residue to 1,4-naphthoquinone, were also identified, as was an adducted peptide from incubation of 1,2-naphthoquinone with apomyoglobin. In the case of incubation of human hemoglobin with the two naphthoquinones, two adducted peptides were identified from the N-terminal valine modification of the alpha and beta chains of human hemoglobin. The adducted protein formation may imply that naphthalene produces its in vivo toxicity through 1,2- and 1,4-naphthoquinone metabolites reacting with biomolecular proteins.  相似文献   

16.
N-(Dicyclohexyl)acetylpiperidine-4-benzylidene-4-carboxylic acid (1) is an excellent in vitro inhibitor of 5 alpha-reductase (5 alpha R). Compound 1 showed, however, much lower inhibition activity of 5 alpha R in vivo than in vitro, which might be caused by poor membrane permeability. The methyl ester of 1 (1a) was therefore tested as a model prodrug to see if it has better permeability properties than the corresponding acid 1. It was also monitored that this methyl ester was cleaved into the active compound 1 within the DU145 cells. Quantitative matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) methods were established with reliable linearity factors (0.996 for MALDI-TOFMS and 0.998 for HPLC/MS/MS) and reproducibility (relative standard deviation = 6.5% for MALDI-TOFMS and 2.8% for HPLC/MS/MS). The samples for MS analysis were effectively prepared from the cell homogenates using solid-phase extraction, with a high recovery of 90% on average. The intracellular amount of 1a (1.7 nmol) was much higher than that of 1 (0.032 nmol) in DU145 cells after 6 h of incubation. After incubation with the ester (1a), the cleaved acid (1) was detected within the cells. The concentration of acid 1 (0.045 nmol) in this experiment was higher than the acid content (0.032 nmol) after direct incubation with 1. Surprisingly, high amounts of the cleaved compound 1 were found outside the cells after 6 h of incubation with 1a.  相似文献   

17.
A biologically active protein fraction was isolated from rabbit intestine, purified by one-dimensional SDS-PAGE and stained with Coomassie Brilliant Blue. A predominant band of approximately 110-130 kDa was excised and digested in-gel with trypsin. The resulting peptides were extracted then separated by microbore reversed-phase high-performance liquid chromatography (HPLC). Mass spectrometric data from one HPLC fraction obtained by two different ionization techniques proved to be complementary. Matrix-assisted laser desorption/ionization (MALDI) showed nine peptide masses, which by post source decay analysis and database searching were attributed to two proteins. Nanoflow electrospray analysis performed on a hybrid tandem mass spectrometer of quadrupole-quadrupole-orthogonal acceleration time-of-flight (QqTOF) geometry detected six additional peptide components. On the basis of the additional peptides and superior quality collision-induced dissociation spectra typical of this instrument type, two further proteins were identified. The resolution afforded by the QqTOF instrument permitted charge state determination for the fragment ions while preserving the high detection sensitivity that was essential in obtaining the composition of this mixture of proteins.  相似文献   

18.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.  相似文献   

19.
The metabolism of limonin 17-beta-D-glucopyranoside (LG) by non-cancerous (RWPE-1) and cancerous (PC-3) human prostate epithelial cells was investigated using high-performance liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) with in-source fragmentation and tandem mass spectrometry (MS/MS). During positive ion LC/ESI-MS, LG formed an abundant sodiated species ([M+Na]+) while the protonated molecule was barely observable. [M+Na]+ further fragmented into the less abundant [LARL+H]+ and a predominantly protonated aglycone molecule (limonin) due to in-source fragmentation. The major metabolite, limonin A-ring lactone (LARL), formed an abundant protonated molecule that was fragmented into a protonated molecule of limonin by loss of one molecule of water. In MS/MS by collisionally activated dissociation (CAD), LG produced the sodiated aglycone, [aglycone+Na]+, while LARL fragmented into [M+H]+ of limonin and fragment ions resulted by further loss of water, carbon monoxide and carbon dioxide, indicating the presence of oxygenated-ring structures. The limits of detection of LG were 0.4 and 20 fmol in selected-ion monitoring (SIM) and selected-reaction monitoring (SRM) detection, respectively.  相似文献   

20.
Measurement of the ratio of testosterone (T) and epitestosterone (E) in urine has been used as an indication of 'natural' steroid supplementation for a decade. The direct measurement of the glucuronide and sulfate conjugates of testosterone and epitestosterone by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) should resolve a number of issues regarding unusual metabolism due to either genetic disposition or attempts to avoid detection of abuse. Determination of nanomoles per liter (0.1 ppb) concentrations of analytes in a complex biological matrix by HPLC/MS/MS is complicated by sample matrix-specific ion suppression during ESI. Deuterated internal standards of all compounds were used to overcome the effects of suppression. Comparison of the HPLC/MS/MS method with a two-part gas chromatographic/mass spectrometric method showed statistical equivalence in urine samples. Analysis of urine samples with elevated T-glucuronide to E-glucuronide ratios did not show that a significant number could be explained by an elevated excretion of epitestosterone sulfate. The HPLC/MS/MS method was also used further to characterize genetic and metabolic factors that give rise to unusual T/E ratios.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号