首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel fingerprinting method, bioactivity fingerprint analysis, based on an ultrafiltration–ultraperformance liquid chromatography–multistage tandem mass spectrometry (UPLC–MS n ) method is proposed for the quality control of herbal medicines from the bioactivity viewpoint concerning the efficacy of herbal medicines. The bioactivity fingerprints reflecting the anti-inflammatory activities of radix Aconiti and radix Aconiti preparata were established. With use of ultrafiltration UPLC–MS n , 11 cyclooxygenase-2 ligands from radix Aconiti preparata and 14 cyclooxygenase-2 ligands from radix Aconiti were found after incubation with cyclooxygenase-2. Twelve of the cyclooxygenase-2 ligands were identified by the ultraperformance UPLC–MS n method. The enrichment factor of each peak in the bioactivity fingerprint was calculated and was demonstrated to be characteristic, which makes bioactivity fingerprint analysis for the quality control of herbal medicines possible from the viewpoint of their bioactivities.
Figure
Bioactivity fingerprint analysis is defined as the chromatograms and spectra of the complex system of effective constituents containing information on their pharmacodynamic activities  相似文献   

2.
We describe a linear ion-trap (LIT) multiple-stage (MSn) mass spectrometric approach towards differentiation of alkylacyl, alk-1-enylacyl- and diacyl-glycerophoscholines (PCs) as the [M – 15] ions desorbed by electrospray ionization (ESI) in the negative-ion mode. The MS4 mass spectra of the [M – 15 – R2′CH = CO] ions originated from the three PC subfamilies are readily distinguishable, resulting in unambiguous distinction of the lipid classes. This method is applied to two alkyl ether rich PC mixtures isolated from murine bone marrow neutrophils and kidney, respectively, to explore its utility in the characterization of complex PC mixture of biological origin, resulting in the realization of the detailed structures of the PC species, including various classes and many minor isobaric isomers.
Graphical abstract
?  相似文献   

3.
An ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC/MS/MS) method was developed and validated for the quantification of serotonin (5-HT) in lamb plasma using [2d4]-serotonin ([2d4]-5-HT) as an internal standard. Charcoal-stripped human plasma was used as the blank matrix during validation, and 5-HT was quantitated using selected reaction monitoring. The UHPLC/MS/MS system consisted of an Agilent 1290 Infinity ultrahigh-performance liquid chromatograph coupled with an AB SCIEX QTRAP® 5500 hybrid linear ion trap triple quadrupole mass spectrometer. The method was validated for accuracy, precision, linearity, lower limit of quantification (LLOQ), selectivity, and other parameters. The LLOQ was 1.0 ng/mL, requiring 100 μL of sample. The method was applied to monitor the 5-HT levels in lamb plasma after the administration of fluoxetine. Tandem mass spectrometry cubed (MS3) experiments were also performed to investigate the fragmentation pattern of 5-HT and [2d4]-5-HT. A liquid chromatography-MS3 (LC/MS3) method was developed, and the UHPLC/MS/MS and the LC/MS3 methods were compared for performance.
Figure
?  相似文献   

4.
A systematic approach is described that can pinpoint the stereo-structures (sugar identity, anomeric configuration, and location) of individual sugar units within linear oligosaccharides. Using a highly modified mass spectrometer, dissociation of linear oligosaccharides in the gas phase was optimized along multiple-stage tandem dissociation pathways (MSn, n = 4 or 5). The instrument was a hybrid triple quadrupole/linear ion trap mass spectrometer capable of high-efficiency bidirectional ion transfer between quadrupole arrays. Different types of collision-induced dissociation (CID), either on-resonance ion trap or beam-type CID could be utilized at any given stage of dissociation, enabling either glycosidic bond cleavages or cross-ring cleavages to be maximized when wanted. The approach first involves optimizing the isolation of disaccharide units as an ordered set of overlapping substructures via glycosidic bond cleavages during early stages of MSn, with explicit intent to minimize cross-ring cleavages. Subsequently, cross-ring cleavages were optimized for individual disaccharides to yield key diagnostic product ions (m/z 221). Finally, fingerprint patterns that establish stereochemistry and anomeric configuration were obtained from the diagnostic ions via CID. Model linear oligosaccharides were derivatized at the reducing end, allowing overlapping ladders of disaccharides to be isolated from MSn. High confidence stereo-structural determination was achieved by matching MSn CID of the diagnostic ions to synthetic standards via a spectral matching algorithm. Using this MSn (n = 4 or 5) approach, the stereo-structures, anomeric configurations, and locations of three individual sugar units within two pentasaccharides were successfully determined.
Fig. a
?  相似文献   

5.
In this preliminary investigation, a low-grade astrocytoma (AcT) is investigated by high-resolution (HR) mass spectrometry (MS) aiming at characterization of gangliosides with potential biomarker value. The research was conducted towards a comparative mapping of ganglioside expression in AcT, its surrounding tissue (ST) and a normal control brain tissue (NT). HR MS was conducted in the negative ion mode nanoelectrospray ionization (nanoESI). Fragmentation analysis was carried out by collision-induced dissociation (CID) MS2–MS4. Due to the high resolving power and mass accuracy, by comparative mapping of the ganglioside extracts from AcT, ST and NT, under identical conditions, 37 different species in AcT, 40 in ST and 56 in NT were identified. AcT and ST were found to contain 18 identical ganglioside components. Among all three specimens, ST extract presented the highest levels of sialylation, fucosylation and acetylation, a feature which might be correlated to the tumor expansion in the adjacent brain area. MS mapping indicated also that AcT, ST and NT share one doubly deprotonated molecule at m/z 1063.31, attributable to GT1(d18:1/18:0) or GT1(d18:0/18:1). CID MS2–MS4 on these particular ions detected in AcT and ST provided data supporting GT1c isomer in the investigated astrocytoma tissue. Our results show that HR MS has a remarkable potential in brain cancer research for the determination of tumor-associated markers and for their structural determination.
Figure
Ganglioside isomer discrimination in human astrocytoma by Orbitrap multistage MS  相似文献   

6.
[M + Ag]+ ions from cyclic and linear polystyrenes and polybutadienes, formed by matrix-assisted laser desorption ionization (MALDI), give rise to significantly different fragmentation patterns in tandem mass spectrometry (MS2) experiments. In both cases, fragmentation starts with homolytic cleavage at the weakest bond, usually a C–C bond, to generate two radicals. From linear structures, the separated radicals depolymerize extensively by monomer losses and backbiting rearrangements, leading to low-mass radical ions and much less abundant medium- and high-mass closed-shell fragments that contain one of the original end groups, along with internal fragments. With cyclic structures, depolymerization is less efficient, as it can readily be terminated by intramolecular H-atom transfer between the still interconnected radical sites (disproportionation). These differences in fragmentation reactivity result in substantially different fragment ion distributions in the MS2 spectra. Simple inspection of the relative intensities of low- versus high-mass fragments permits conclusive determination of the macromolecular architecture, while full spectral interpretation reveals the individual end groups of linear polymers or the identity of the linker used to form the cyclic polymer.
Figure
Macrocyclic and linear polystyrene and polydiene architectures are conclusively distinguished by the MS2 fragmentation patterns of Ag+-cationized oligomers.  相似文献   

7.
Here, we describe a new application of ultra-performance liquid chromatography coupled with an electrospray ionization quadrupole time-of-flight mass spectrometry operating in MSE mode (UPLC-QTOF-MSE) for the sensitive, fast, and effective characterization of alkaloids in goldenseal (Hydrastis canadensis). This approach allowed identification of alkaloids using a cyclic low and high collision energy spectral acquisition mode providing simultaneous accurate precursor and fragment ion mass information. A total of 45 compounds were separated and 40 of them characterized including one new compound and 7 identified for the first time in goldenseal. The spectral data obtained using this method is comparable to those obtained by conventional LC-MSn. However, the UPLC-QTOF-MSE method offers high chromatographic resolution with structural characterization facilitated by accurate mass measurement in both MS and MS/MS modes in a single analytical run; this makes it suitable for the rapid analysis and screening of alkaloids in plant extracts.
Figure
Identification of alkaloids in goldenseal by UPLC-QTOF-MS in MSE mode  相似文献   

8.
Obtaining unambiguous linkage information between sugars in oligosaccharides is an important step in their detailed structural analysis. An approach is described that provides greater confidence in linkage determination for linear oligosaccharides based on multiple-stage tandem mass spectrometry (MSn, n >2) and collision-induced dissociation (CID) of Z1 ions in the negative ion mode. Under low energy CID conditions, disaccharides 18O-labeled on the reducing carbonyl group gave rise to Z1 product ions (m/z 163) derived from the reducing sugar, which could be mass-discriminated from other possible structural isomers having m/z 161. MS3 CID of these m/z 163 ions showed distinct fragmentation fingerprints corresponding to the linkage types and largely unaffected by sugar unit identities or their anomeric configurations. This unique property allowed standard CID spectra of Z1 ions to be generated from a small set of disaccharide samples that were representative of many other possible isomeric structures. With the use of MSn CID (n = 3 – 5), model linear oligosaccharides were dissociated into overlapping disaccharide structures, which were subsequently fragmented to form their corresponding Z1 ions. CID data of these Z1 ions were collected and compared with the standard database of Z1 ion CID using spectra similarity scores for linkage determination. As the proof-of-principle tests demonstrated, we achieved correct determination of individual linkage types along with their locations within two trisaccharides and a pentasaccharide.
Figure
?  相似文献   

9.
Xylazine is used in veterinary medicine for sedation, anesthesia, and analgesia. It has also been reported to be misused as a horse doping agent, a drug of abuse, a drug for attempted sexual assault, and as source of accidental or intended poisonings. So far, no data concerning human metabolism have been described. Such data are necessary for the development of toxicological detection methods for monitoring drug abuse, as in most cases the metabolites are the analytical targets. Therefore, the metabolism of xylazine was investigated in rat and human urine after several sample workup procedures. The metabolites were identified using gas chromatography (GC)–mass spectrometry (MS) and liquid chromatography (LC) coupled with linear ion trap high-resolution multistage MS (MS n ). Xylazine was N-dealkylated and S-dealkylated, oxidized, and/or hydroxylated to 12 phase I metabolites. The phenolic metabolites were partly excreted as glucuronides or sulfates. All phase I and phase II metabolites identified in rat urine were also detected in human urine. In rat urine after a low dose as well as in human urine after an overdose, mainly the hydroxy metabolites were detected using the authors’ standard urine screening approaches by GC–MS and LC–MS n . Thus, it should be possible to monitor application of xylazine assuming similar toxicokinetics in humans.
Figure
Reconstructed high-resolution mass chromatograms indicating xylazine and its phase I metabolites as well as the mass spectra with structures of xylazine and one of its hydroxy metabolites  相似文献   

10.
We have recently developed a multiplex mass spectrometry imaging (MSI) method which incorporates high mass resolution imaging and MS/MS and MS3 imaging of several compounds in a single data acquisition utilizing a hybrid linear ion trap-Orbitrap mass spectrometer (Perdian and Lee, Anal. Chem. 82, 9393–9400, 2010). Here we extend this capability to obtain positive and negative ion MS and MS/MS spectra in a single MS imaging experiment through polarity switching within spiral steps of each raster step. This methodology was demonstrated for the analysis of various lipid class compounds in a section of mouse brain. This allows for simultaneous imaging of compounds that are readily ionized in positive mode (e.g., phosphatidylcholines and sphingomyelins) and those that are readily ionized in negative mode (e.g., sulfatides, phosphatidylinositols and phosphatidylserines). MS/MS imaging was also performed for a few compounds in both positive and negative ion mode within the same experimental set-up. Insufficient stabilization time for the Orbitrap high voltage leads to slight deviations in observed masses, but these deviations are systematic and were easily corrected with a two-point calibration to background ions.
Figure
?  相似文献   

11.
We report the development of a new AP visible-wavelength MALDI-ion trap-MS instrument with significantly improved performance over our previously reported system (Int. J. Mass Spectrom. 315, 66–73 (2012)). A Nd:YAG pulsed laser emitting light at 532 nm was used to desorb and ionize oligosaccharides and peptides in transmission geometry through a glass slide. Limits of detection (LODs) achieved in MS mode correspond to picomole quantities of oligosaccharides and femtomole quantities of peptides. Tandem MS (MS/MS) experiments enabled identification of enzymatically digested proteins and oligosaccharides by comparison of MS/MS spectra with data found in protein and glycan databases. Moreover, the softness of ionization, LODs, and fragmentation spectra of biomolecules by AP visible-wavelength MALDI-MS were compared to those obtained by AP UV MALDI-MS using a Nd:YAG laser emitting light at 355 nm. AP visible-wavelength MALDI appears to be a softer ionization technique then AP UV MALDI for the analysis of sulfated peptides, while visible-wavelength MALDI-MS, MS/MS, and MS/MS/MS spectra of other biomolecules analyzed were mostly similar to those obtained by AP UV MALDI-MS. Therefore, the methodology presented will be useful for MS and MSn analyses of biomolecules at atmospheric pressure. Additionally, the AP visible-wavelength MALDI developed can be readily used for soft ionization of analytes on various mass spectrometers.
Figure
?  相似文献   

12.
Synthetic modified oligonucleotides are of interest for diagnostic and therapeutic applications, as their biological stability, pairing selectivity, and binding strength can be considerably increased by the incorporation of unnatural structural elements. Homo-DNA is an oligonucleotide homologue based on dideoxy-hexopyranosyl sugar moieties, which follows the Watson-Crick A-T and G-C base pairing system, but does not hybridize with complementary natural DNA and RNA. Homo-DNA has found application as a bioorthogonal element in templated chemistry applications. The gas-phase dissociation of homo-DNA has been investigated by ESI-MS/MS and MALDI-MS/MS, and mechanistic aspects of its gas-phase dissociation are discussed. Experiments revealed a charge state dependent preference for the loss of nucleobases, which are released either as neutrals or as anions. In contrast to DNA, nucleobase loss from homo-DNA was found to be decoupled from backbone cleavage, thus resulting in stable products. This renders an additional stage of ion activation necessary in order to generate sequence-defining fragment ions. Upon MS3 of the primary base-loss ion, homo-DNA was found to exhibit unspecific backbone dissociation resulting in a balanced distribution of all fragment ion series.
Figure
?  相似文献   

13.
Multiwalled carbon nanotubes were impregnated with 4-(2-thiazolylazo)resorcinol and used for the separation and preconcentration of Cd(II), Pb(II), Zn(II) and Ni(II) ions from food samples. The analytes were quantitatively recovered at pH 7.0 and eluted with 3?mol?L?1 acetic acid. The effects of pH value, flow rate, eluent type and sample volume on the recoveries, and the effects of alkali, earth alkali and transition metals on the retention of the analytes were studied. The method was validated using the standard certified reference materials SRM 1570A (spinach leaves) and IAEA 336 (lichen), and the results were found to be compatible with the certified values of reference materials. The new enrichment procedure was applied to the determination of these ions in various food samples.
Figure
Multiwalled carbon nanotubes were impregnated with 4-(2-thiazolylazo)resorcinol and used for the separation and preconcentration of Cd(II), Pb(II), Zn(II) and Ni(II) ions from food samples. The analytes were quantitatively recovered at pH 7.0 and eluted with 3 mol L-1 acetic acid. The method was validated using the standard certified reference materials SRM 1570A (spinach leaves) and IAEA 336 (lichen), and the results were found to be compatible with the certified values of reference materials. The new enrichment procedure was applied to the determination of these ions in various food samples.  相似文献   

14.
Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4′-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.
Figure
Comparison of Concentrations of Selected Compounds in Human Serum and Human Milk Standard Reference Materials (SRMs)  相似文献   

15.
A new method for measuring perfluoroalkyl contaminants (PFCs) in biological matrices has been developed. An ultra-high pressure liquid chromatograph equipped with a quadrupole time-of-flight mass spectrometer (UPLC-QToF) was optimized using a continuous precursor/product ion monitoring mode. Unlike traditional targeted studies that isolate precursor/product ion pairs, the current method alternates between two ionization energy channels to continuously capture standard electrospray ionization (low energy) and collision induced dissociation (high energy) spectra. The result is the indiscriminant acquisition of paired low and high energy spectra for all constituents eluting from the chromatographic system. This technique was evaluated for the routine analysis of perfluoroalkyl species. Using this technique, linear perfluoroalkyl carboxylic acids (C4 to C14) and perfluoroalkyl sulfonates (C4, C6, C8 and C10) exhibited a linear range spanning over three orders of magnitude and were detectable at levels less than 1 pg on column with a root mean squared signal to noise ratio of 5 to 20. Lake trout (Salvelinus namaycush) and National Institutes of Standards and Technology Standard Reference Material 1946 were used to evaluate matrix effects and the accuracy of this method when applied to a whole fish extract. The current method was also evaluated as a diagnostic tool to identify unknown PFCs using experimental fragmentation patterns, mass defect filtering and Kendrick plots.
Figure
The future of toxics analysis in biological media: cataloging spectral fingerprints at targeted analysis sensitivity.  相似文献   

16.
We report on a sensitive, reliable and relatively fast method for separation, preconcentration and determination of trace quantities of copper(II) ion. It is making use of nanometer-sized γ-alumina nanoparticles modified with sodium dodecyl sulfate (SDS). The adsorptive potential was assessed via a Langmuir isotherm and the maximal sorption capacity was found to be 138 mg g-1. The effects of pH values, amount of ligand, flow rate, type of eluting agent, volume of eluent, and the volume of sample were examined. The effects of interfering ions on the recovery of the analyte were also investigated. Copper ion was then determined by flame atomic absorption spectrometry. The relative standard deviation for five replicate determinations (at 50 μg L?1 of copper) is 3.3%. The detection limit (at 3 s) is 2.5 μg L?1. This method was validated with a certified reference material of oyster tissue (NIST SRM 1566b) and the results coincided well with the certified values. The procedure was successfully applied to the determination of Cu in water and food samples.
Figure
Alumina nanoparticles modified with SDS have been used as sorbent for separation and preconcentration of copper after complexation with APDC.  相似文献   

17.
Ion pair solid phase extraction was applied to the simultaneous preconcentration of iron and antimony. The ion pairs consisting of FeCl4 ? or SbCl4 ? anions and the benzyldimethyltetradecyl ammonium cation were formed on the surface of multi-walled carbon nanotubes, then eluted with nitric acid, and the elements finally quantified by ETAAS. The adsorption capacities of the impregnated MWCNTs are 9.2 mg g?1 for iron and 27.5 mg g?1 for antimony. The following analytical figures of merit were determined for iron and antimony, respectively: Enrichment factors of 210 and 230, assay precisions of ±5.3 % and ±4.8 %, linear calibration plots from 0.7 to 9.4 and 13.0 to 190 ng L?1, and detection limits of 0.17 and 3.5 ng L?1. The method was applied to the determination of iron and antimony in human hair, synthetic sample, and to the certified reference materials gold ore (MA-1b) and trace elements in water (SRM 1643d).
Figure
?  相似文献   

18.
Analysis of triacylglycerols (TAGs), found as complex mixtures in living organisms, is typically accomplished using liquid chromatography, often coupled to mass spectrometry. TAGs, weak bases not protonated using electrospray ionization, are usually ionized by adduct formation with a cation, including those present in the solvent (e.g., Na+). There are relatively few reports on the binding of TAGs with cations or on the mechanisms by which cationized TAGs fragment. This work examines binding efficiencies, determined by mass spectrometry and computations, for the complexation of TAGs to a range of cations (Na+, Li+, K+, Ag+, NH4 +). While most cations bind to oxygen, Ag+ binding to unsaturation in the acid side chains is significant. The importance of dimer formation, [2TAG + M]+ was demonstrated using several different types of mass spectrometers. From breakdown curves, it became apparent that two or three acid side chains must be attached to glycerol for strong cationization. Possible mechanisms for fragmentation of lithiated TAGs were modeled by computations on tripropionylglycerol. Viable pathways were found for losses of neutral acids and lithium salts of acids from different positions on the glycerol moiety. Novel lactone structures were proposed for the loss of a neutral acid from one position of the glycerol moiety. These were studied further using triple-stage mass spectrometry (MS3). These lactones can account for all the major product ions in the MS3 spectra in both this work and the literature, which should allow for new insights into the challenging analytical methods needed for naturally occurring TAGs.
Figure
?  相似文献   

19.
A carbon paste electrode (CPE) was modified with multi-wall carbon nanotubes and successfully applied to the determination of silver ion by differential pulse anodic stripping voltammetry. Compared to a conventional CPE, a remarkably improved peak current response and sensitivity is observed. The analytical procedure consisted of an open circuit accumulation step for 2?min in ?0.4?V, this followed by an anodic potential scan between +0.2 and?+?0.6?V to obtain the voltammetric peak. The oxidation peak current is proportional to the concentration of silver ion in the range from 1.0?×?10?8 to 1.0?×?10?5?mol?L?1, with a detection limit of 1.8?×?10?9?mol?L?1 after an accumulation time of 120?s. The relative standard deviation for 7 successive determinations of Ag(I) at 0.1???M concentration is 1.99%. The procedure was validated by determining Ag(I) in natural waters.
Figure
Differential pulse voltammogram (DPV) of Ag+ solution at MCPE  相似文献   

20.
The present work describes the development of a robust and sensitive targeted analysis platform for the simultaneous quantification in blood plasma of lipid oxygenated mediators and fatty acids using solid-phase extraction (SPE) and high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). The concurrent analysis of these lipid mediators is challenging because of their instability, differences in solubility, and the frequent occurrence of isobaric forms with similar fragmentation patterns. Results demonstrated that the reduction of SPE temperature to 4 °C is a critical parameter for preserving the hydroperoxy derivatives. Polymeric HLB cartridges increased 40–50 % ARA, EPA, and DHA sensitivity compared to C18 sorbent and also provided higher global performance for most hydroxides and other oxidation products. The proposed method for the two tested mass analyzers yields high sensitivity, good linearity, and reproducibility, with detection limits ranging 0.002–7 ng/mL and global recoveries as high as 85–112 %. However, the additional advantage of the linear ion trap (LIT) mass analyzer working in full scan product ion mode, compared to the triple quadrupole (QqQ) operating in multiple reaction monitoring (MRM), should be noted: the full scan product ion mode provides the full fragmentation spectra of compounds that allowed the discrimination of coeluting isomers and false positive identifications without additional chromatography development. The proposed lipidomic procedure demonstrates a confident, simple, and sensitive method to profile in plasma a wide range of lipid eicosanoid and docosanoid mediators, including innovatively the analysis of hydroperoxy congeners and nonoxidized PUFA precursors.
Figure
?  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号