首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
It is reported for the first time that hemoglobin (Hb) was immobilized on the surface of carbon black powders modified at the surface of a glassy carbon electrode. The cyclic voltammetric results showed that the immobilized Hb could undergo a direct quasi-reversible electrochemical reaction. Its formal potential, E(0), is -0.330 V in phosphate buffer solution (pH 6.9) at a scan rate of 100 mV/s and is almost independent of the scan rate in the range of 40-200 mV/s. The dependence of E(0), on the pH of the buffer solution indicated that the conversion of Hb-Fe(III)/Hb-Fe(II) is a one-electron-transfer reaction process coupled with one-proton-transfer. The experimental results also demonstrated that the immobilized Hb retained its bioelectrocatalytic activity for the reduction of H(2)O(2). Furthermore, the immobilized Hb can be stored at 4 degrees C for several weeks without any loss of the enzyme activity. Thus, the immobilized Hb may be used as a biocathodic catalyst in biofuel cells.  相似文献   

2.
Catalase was investigated as a possible catalyst of the electrochemical reduction of oxygen on glassy carbon electrodes. The presence of catalase dissolved in solution only provoked a moderate current increase, which was fully explained by the catalase-catalysed disproportionation of hydrogen peroxide (Scheme I). When catalase was adsorbed from dimethylsulfoxide on the surface of electrodes that did not undergo any electrochemical pre-treatment (EP), catalase efficiently catalysed oxygen reduction via direct electron transfer from the electrode (Scheme II). The results are discussed with respect to the electrode surface properties and the enzyme structure.  相似文献   

3.
4.
We have studied the direct electrochemistry of glucose oxidase (GOx) immobilized on electrochemically fabricated graphite nanosheets (GNs) and zinc oxide nanoparticles (ZnO) that were deposited on a screen printed carbon electrode (SPCE). The GNs/ZnO composite was characterized by using scanning electron microscopy and elemental analysis. The GOx immobilized on the modified electrode shows a well-defined redox couple at a formal potential of ?0.4 V. The enhanced direct electrochemistry of GOx (compared to electrodes without ZnO or without GNs) indicates a fast electron transfer at this kind of electrode, with a heterogeneous electron transfer rate constant (Ks) of 3.75 s?1. The fast electron transfer is attributed to the high conductivity and large edge plane defects of GNs and good conductivity of ZnO-NPs. The modified electrode displays a linear response to glucose in concentrations from 0.3 to 4.5 mM, and the sensitivity is 30.07 μA mM?1 cm?2. The sensor exhibits a high selectivity, good repeatability and reproducibility, and long term stability. Figure
Graphical representation for the fabrication of GNs/ZnO composite modified SPCE and the immobilization of GOx  相似文献   

5.

We have studied the direct electrochemistry of glucose oxidase (GOx) immobilized on electrochemically fabricated graphite nanosheets (GNs) and zinc oxide nanoparticles (ZnO) that were deposited on a screen printed carbon electrode (SPCE). The GNs/ZnO composite was characterized by using scanning electron microscopy and elemental analysis. The GOx immobilized on the modified electrode shows a well-defined redox couple at a formal potential of −0.4 V. The enhanced direct electrochemistry of GOx (compared to electrodes without ZnO or without GNs) indicates a fast electron transfer at this kind of electrode, with a heterogeneous electron transfer rate constant (Ks) of 3.75 s−1. The fast electron transfer is attributed to the high conductivity and large edge plane defects of GNs and good conductivity of ZnO-NPs. The modified electrode displays a linear response to glucose in concentrations from 0.3 to 4.5 mM, and the sensitivity is 30.07 μA mM−1 cm−2. The sensor exhibits a high selectivity, good repeatability and reproducibility, and long term stability.

Graphical representation for the fabrication of GNs/ZnO composite modified SPCE and the immobilization of GOx

  相似文献   

6.
Shengfu Wang  Fen Xie 《Talanta》2009,77(4):1343-58
Direct electrochemistry and electrocatalysis of heme proteins including hemoglobin (Hb), myoglobin (Mb) and horseradish peroxidase (HRP) were studied with the protein incorporated single walled carbon nanotubes (SWCNTs)-cetylramethylammonium bromide (CTAB) nanocomposite film modified glassy carbon electrodes (GCEs). The incorporated heme proteins were characterized with Fourier transform infrared spectroscopy (FTIR), ultraviolet visible (UV) spectroscopy, atomic force microscopy (AFM) and electrochemistry, indicating the heme proteins in SWCNTs-CTAB nanocomposite films keep their secondary structure similar to their native states. The direct electron transfer between the heme proteins in SWCNTs-CTAB films and GCE was investigated. The electrochemical parameters such as formal potentials and apparent heterogeneous electrontransfer rate constants (ks) were estimated by square wave voltammetry with nonlinear regression analysis. The heme protein-SWCNT-CTAB electrodes show excellent electrocatalytic activities for the reduction of H2O2 and NO2, which have been utilized to determine the concentrations of H2O2 and NO2.  相似文献   

7.
Direct electrochemistry of heme multicofactor-containing enzymes, e.g., microbial theophylline oxidase (ThOx) and D-fructose dehydrogenase (FDH) from Gluconobacter industrius was studied on alkanethiol-modified gold electrodes and was compared with that of some previously studied complex heme enzymes, specifically, cellobiose dehydrogenase (CDH) and sulphite oxidase (SOx). The formal redox potentials for enzymes in direct electronic communication varied for ThOx from -112 to -101 mV (vs. Ag|AgCl), at pH 7.0, and for FDH from -158 to -89 mV, at pH 5.0 and pH 4.0, respectively, on differently charged alkanethiol layers. Direct and mediated by cytochrome c electrochemistry of FDH correlated with the existence of two active centres in the protein structure, i.e., the heme and the pyrroloquinoline quinone (PQQ) prosthetic groups. The effect of the alkanethiols of different polarity and charge on the surface properties of the gold electrodes necessary for adsorption and orientation of ThOx, FDH, CDH and SOx, favourable for the efficient electrode-enzyme electron transfer reaction, is discussed.  相似文献   

8.
A new method for the pretreatment of screen-printed carbon electrodes (SPCEs) by two successive steps was proposed. In step one, fresh SPCEs were soaked into NaOH with high concentration (e.g. 3 M) for tens to hundreds of minutes, and the resulted electrodes were called as SPCE-I. In step two, SPCE-I were pre-anodized in low concentration of NaOH, which were designated as SPCE-II. The pretreated electrodes showed remarkable enhancement in heterogeneous electron transfer rate constant (k0) increased from 1.6 × 10−4 cm s−1 at the fresh SPCE to 1.1 × 10−2 cm s−1 at SPCE-I for Fe(CN)63−/4− couple. The peak to peak separation (ΔEp) in cyclic voltammetry was reduced from ca. 480 to 84 mV, indicating that the electrochemical reversibility was greatly promoted, possibly due to the removing of polymers/oil binder from the electrode surfaces. The electroactive area (Aea) of the electrode was increased by a factor of 17 after pretreatment in step one. Further analysis by the electrochemical impedance method showed that the electron transfer resistance (Rct) decreased from ca. 2100 to 1.4 Ω. These pretreated electrodes, especially SPCE-II, exhibited excellent electrocatalytic behavior for the redox of dopamine (DA). Interference from ascorbic acid (AA) in the detection of DA at SPCE-II could be effectively eliminated due to the anodic peak separation (190 mV) between DA and AA, which resulted from the functionalization of the electrode surface in the pretreatment of step two. Under optimum conditions, current responses to DA were linearly changed in two concentration intervals, one was from 3.0 × 10−7 to 9.8 × 10−6 M, and the other was from 9.8 × 10−6 to 3.3 × 10−4 M. The detection limit for DA was down to 1.0 × 10−7 M.  相似文献   

9.
The construction and performance characteristics of different phosphate ion-selective electrodes are described. Three types of electrodes are demonstrated, namely screen-printed, carbon paste and the conventional PVC membrane electrodes. The cited electrodes are based on bisthiourea ionophores and show a considerable selectivity towards hydrogenphosphate with Nernstian slopes depending on the type of the electrode and the ionophore used. Matrix compositions of each electrode are optimised on the basis of effects of type and concentration of the ionophore as well as influence of the selected plasticizers. The screen-printed electrodes work satisfactorily in the concentration range 10−5 to 10−2 mol L−1 with anionic Nernstian compliance (32.8 mV/decade activity) and detection limit 4.0 × 10−6 mol L−1. The screen-printed electrodes show fast response time of about 2.2 s and exhibit adequate shelf-life (4 months). The fabricated electrodes can be also successfully used in the potentiometric titration of HPO42− with Ba2+.  相似文献   

10.
The communication reports the direct oxidation of human haemoglobin at a bare boron-doped diamond electrode under moderately alkaline conditions with detection limit of 0.4 microM.  相似文献   

11.
Direct electrochemistry of hemoglobin (Hb) on natural nano-structural attapulgite clay film-modified glassy carbon (GC) electrode was investigated. The interaction between Hb and attapulgite was examined using UV-vis, FTIR spectroscopy, and electrochemical methods. The immobilized Hb displayed a couple of well-defined and quasi-reversible redox peaks with the formal potential (E(0')) of about -0.366 V (versus SCE) in 0.1 M phosphate buffer solution of pH 7.0. The current was linearly dependent on the scan rate, indicating that the direct electrochemistry of Hb in that case was a surface-controlled electrode process. The formal potential changed linearly from pH 5.0 to 9.0 with a slope value of -48.2 mV/pH, which suggested that a proton transfer was accompanied with each electron transfer in the electrochemical reaction. The immobilized Hb exhibited excellent electrocatalytic activity for the reduction of hydrogen peroxide without the aid of an electron mediator. The electrocatalytic response showed a linear dependence on the H(2)O(2) concentration ranging from 5.4 x 10(-6) to 4.0 x 10(-4) M with the detection of 2.4 x 10(-6) M at a signal-to-noise ratio of 3. The apparent Michaelis-Menten constant K(M)(app) for the H(2)O(2) sensor was estimated to be 490 microM, showing a high affinity.  相似文献   

12.
Cui G  Yoo JH  Lee JS  Yoo J  Uhm JH  Cha GS  Nam H 《The Analyst》2001,126(8):1399-1403
The effect of various electrochemical pre-treatment methods on the surface and electrochemical properties of screen-printed carbon paste electrodes (SPCE) prepared with three different commercial products was examined. It was observed that a positively charged redox couple, e.g., hexaammineruthenium(III), exhibited quasi-reversible behavior at the untreated SPCE. However, the cyclic voltammograms (CVs) of the SPCE prepared with general-purpose carbon inks did not exhibit clear redox peaks to other representative redox couples [e.g., hexacyanoferrate(III), hexachloroiridate(IV), dopamine, and hydroquinone] without activation. Electrochemical pre-treatment methods were sought in four different aqueous solutions, i.e., sulfuric acid, potassium chloride, sodium hydrogencarbonate, and sodium carbonate, applying various activation potentials. It was found that the pre-treatment procedure in saturated Na2CO3 solution at 1.2 V provides a mild and effective condition for activating the SPCE. By measuring the water contact angles at the SPCE surfaces and recording their SEM images, it was confirmed that the electrochemical pre-treatment effectively removes the organic binders from the surface carbon particles. A prolonged period of activation (> 5 min) or the use of high potentials (> 1.2 V) increased the capacitance of the electrode over 20 microF cm(-2). The pre-treated SPCE behaved like a random array microelectrode, exhibiting a sigmoidal-shaped CV at a slow scan rate. The short pre-anodization method in Na2CO3 solution was generally applicable to most SPCE prepared with general-purpose carbon inks.  相似文献   

13.
A new electrochemical method has been described and characterized for the determination of cocaine using screen-printed biosensors. The enzyme cytochrome P450 was covalently attached to screen-printed carbon electrodes. Experimental design methodology has been performed to optimize the pH and the applied potential, both variables that have an influence on the chronoamperometric determination of the drug. This method showed a reproducibility of 3.56% (n = 4) related to the slopes of the calibration curves performed in the range from 19 up to 166 nM. It has been probed the used of this kind of biosensors in the determination of cocaine in street samples, with an average capability of detection of 23.05 ± 3.53 nM (n = 3, α = β = 0.05).  相似文献   

14.
Carbon screen-printed electrodes (CSPE) modified with gold nanoparticles present an interesting alternative in the determination of antimony using differential pulse anodic stripping voltammetry. Metallic gold nanoparticles deposits have been obtained by direct electrochemical deposition. Scanning electron microscopy measurements show that the electrochemically synthesized gold nanoparticles are deposited in aggregated form. Any undue effects caused by the presence of foreign ions in the solution were also analyzed to ensure that common interferents in the determination of antimony by ASV. The detection limit for Sb(III) obtained was 9.44 × 10−10 M. In terms of reproducibility, the precision of the above mentioned method in %R.S.D. values was calculated at 2.69% (n = 10). The method was applied to determine levels of antimony in seawater samples and pharmaceutical preparations.  相似文献   

15.
Carboxylated multiwalled carbon nanotubes (MWCNT-COOH) dissolved in a mixture of DMF:water were used to modify the surfaces of commercially available screen-printed electrodes (SPEs). The morphology of the MWCNT-COOH and the modified SPEs was characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM), respectively. SEM analysis showed a porous structure formed by a film of disordered nanotubes on the surface of the working electrode.The modification procedure with MWCNT-COOH was optimised and it was applied to unify the electrochemical behaviour of different gold and carbon SPEs by using p-aminophenol as the benchmark redox system. The analytical advantages of the MWCNT-COOH-modified SPEs as voltammetric and amperometric detectors as well as their catalytic properties were discussed through the analysis, for instance, of dopamine and hydrogen peroxide. Experimental results show that the electrochemical active area of the nanotube-modified electrode increased around 50%. The repeatability of the modification methodology is around 6% (R.S.D.) and the stability of MWCNT-COOH-modified SPEs is ensured for, at least, 2 months.  相似文献   

16.
Sha Y  Qian L  Ma Y  Bai H  Yang X 《Talanta》2006,70(3):556-560
Multilayer films containing multiwall carbon nanotubes and redox polymer were successfully fabricated on a screen-printed carbon electrode using layer-by-layer (LBL) assembled method. UV-vis spectroscopy, X-ray photoelectron spectroscopy, field-emission scanning electron microscopy and electrochemical method were used to characterize the assembled multilayer films. The multilayer films modified electrodes exhibited good electrocatalytic activity towards the oxidation of ascorbic acid (AA). Compared with the bare electrode, the oxidation peak potential negatively shifted about 350 mV (versus Ag/AgCl). Furthermore, the modified screen-printed carbon electrodes (SPCEs) could be used for the determination of ascorbic acid in real samples.  相似文献   

17.
DNA-sensing platforms were prepared by covalently attaching oligonucleotide capture probes onto p-aminophenyl-functionalized carbon surfaces and applied to the determination of an amplified herpes virus DNA sequence in an electrochemical hybridization assay.  相似文献   

18.
A graphene (GR) and multi-walled carbon nanotubes (MWCNT) hybrid was prepared and modified on a 1-hexylpyridinium hexafluorophosphate based carbon ionic liquid electrode (CILE). Hemoglobin (Hb) was immobilized on GR-MWCNT/CILE surface with Nafion as the film forming material and the modified electrode was denoted as Nafion/Hb-GR-MWCNT/CILE. Spectroscopic results revealed that Hb molecules retained its native structure in the GR-MWCNT hybird. Electrochemical behaviors of Hb were carefully investigated by cyclic voltammetry with a pair of well-defined redox peaks obtained, which indicated that direct electron transfer of Hb was realized in the hybrid modified electrode. The result could be attributed to the synergistic effects of GR-MWCNT hybrid with enlarged surface area and improved conductivity through the formation of a three-dimensional network. Electrochemical parameters of the immobilized Hb on the electrode surface were further calculated with the results of the electron transfer number (n) as 1.03, the charge transfer coefficient (a) as 0.58 and the electron-transfer rate constant (ks) as 0.97 s−1. The Hb modified electrode showed good electrocatalytic ability toward the reduction of different substrates such as trichloroacetic acid in the concentration range from 0.05 to 38.0 mmol L−1 with a detection limit of 0.0153 mmol L−1 (3σ), H2O2 in the concentration range from 0.1 to 516.0 mmol L−1 with a detection limit of 34.9 nmol/L (3σ) and NaNO2 in the concentration range from 0.5 to 650.0 mmol L−1 with a detection limit of 0.282 μmol L−1 (3σ). So the proposed electrode had the potential application in the third-generation electrochemical biosensors without mediator.  相似文献   

19.
The direct electrochemistry of the single heme cytochrome c551 from the bacterium Pseudomonas aeruginosa has been investigated at gold electrodes surface-modified through chemisorption of polyfunctional organic molecules. The results have been compared and contrasted with those obtained under the same conditions for the eukaryotic cytochrome c from horse heart. Both cytochromes give a quasi-reversible electrode reaction at pH 6.0 at a modified interface presenting only 4-pyridyl groups to the solution suggesting the occurrence, in both cases, of a hydrogen bonding interaction from lysine side-chains on the protein to pyridyl-nitrogens on the electrode surface. However, in contrast, gold electrodes modified by Pyridine-n-AldehydeThioSemicarbazones (n = 2, 3, 4) give electrochemistry which is strongly isomer-dependent in the case of horse heart cytochrome c but completely isomer-independent in the case of cytochrome c551. It is suggested that interaction of the eukaryotic protein with surfaces is dominated by its lysine residues only, but that interaction of the bacterial cytochrome is through hydrogen bonding from the surface to both lysines and carboxylate groups of aspartate residues. This is supported by observation of the loss of cytochrome c551 electrochemistry at 4-pyridyl-only modified gold at pH 9.0 compared with the good, quasi-reversible electrochemistry maintained under the same conditions at PATS-4 modified gold. It is concluded that, while the two cytochromes show many similarities with respect to their structures and functions, they have quite different interfacial electron transfer reactions, particularly at PATS-modified electrodes. This may correlate with the known large differences between the two proteins in net electrostatic charge and surface charge distribution.  相似文献   

20.
The direct electrochemistry of glucose oxidase (GOx) immobilized on a composite matrix based on chitosan (CHIT) and NdPO(4) nanoparticles (NPs) underlying on glassy carbon electrode (GCE) was achieved. The cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the modified electrode. In deaerated buffer solutions, the cyclic voltammetry of the composite films of GOx/NdPO(4) NPs/CHIT showed a pair of well-behaved redox peaks that are assigned to the redox reaction of GOx, confirming the effective immobilization of GOx on the composite film. The electron transfer rate constant was estimated to be 5.0 s(-1). The linear dynamic range for the detection of glucose was 0.15-10 mM with a correlation coefficient of 0.999 and the detection limit was estimated at about 0.08 mM (S/N=3). The calculated apparent Michaelis-Menten constant was 2.5 mM, which suggested a high affinity of the enzyme-substrate. The immobilized GOx in the NdPO(4) NPs/CHIT composite film retained its bioactivity. Furthermore, the method presented here can be easily extended to immobilize and obtain the direct electrochemistry of other redox enzymes or proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号