首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 98 毫秒
1.
A simple, rapid, and sensitive liquid chromatography-mass spectrometry (MS)-MS method for quantitating paclitaxel in rat plasma is developed. Liquid-liquid extraction with tert-butyl methyl ether is used for sample preparation, and docetaxel is used as the internal standard. Paclitaxel and docetaxel are separated on a C18 column and quantitated using a triple-quadrupole MS operating in positive ion electrospray selective reaction monitoring mode with a total run time of 6.0 min. The peak area of the m/z 876.3 --> 307.9 transition of paclitaxel is measured versus that of the m/z 830.3 --> 549.1 transition of docetaxel to generate the standard curve. The standard curve is linear over the concentration range of 0.2008-1004 ng/mL for rat plasma. The method has high extraction recovery (> 90%) and accuracy (> 90%), with the intra- and interday precision < 15%. Frozen stability, freeze-and-thaw stability, extracted stability, and room temperature solution stability are also examined. This assay is used to support a pharmacokinetic study of paclitaxel self-assembled nanoliposome in rats.  相似文献   

2.
《Analytical letters》2012,45(7):1349-1363
Abstract

A liquid chromatography‐tandem triple‐quadrupole mass spectrometry assay to quantify palitaxel in rat tissue homogenates containing paclitaxel nanoliposome (PTX‐NLP) modified by PEO-PPO-PEO triblock copolymers was developed and validated. Liquid–liquid extraction with tert‐butyl methyl ether was used for preparation of tissue samples and docetaxel was used as the internal standard. Paclitaxel and docetaxel were separated on a 200 mm×4.6 mm×5 µm C18 column and quantified using a triple‐quadrupole mass spectrometer operating in positive ion electrospray selective reaction monitoring mode (ESI+‐SRM) with a total run time of 6.0 min. The peak area of the m/z 876.3→307.9 transition of paclitaxel is measured vs. that of the m/z 830.3→549.1 transition of docetaxel to generate the standard curves. The standard curves were linear over the concentration range of 0.2–2000 ng/mL for different tissues. The method had high extraction recovery (>90%) and accuracy (>90%) with the intraday and inter‐day precision <15%. Frozen stability, freeze‐thaw stability, extracted stability, and solution stability under ambient temperature were examined, which indicated the tissue samples should be extracted within 5 days and avoid being frozen and thawed repeatedly over 5 times, extracted samples after evaporation could be stored at ?20°C for 20 days without drug degradation, also, no degradation was observed after solution samples were left out at ambient temperature for 24 h. This assay was used to support an in vivo biodistribution study of paclitaxel nanoliposome modified by PEO-PPO-PEO triblock copolymers in rats.  相似文献   

3.
A quantitative liquid chromatography/ion trap mass spectrometry method for the simultaneous determination of paclitaxel, 6alpha-hydroxypaclitaxel and p-3'-hydroxypaclitaxel in human plasma has been developed and validated. 6alpha-,p-3'-Dihydroxypaclitaxel was also quantified using paclitaxel as a reference and docetaxel as an internal standard. The substances were extracted from 0.500 mL plasma using solid-phase extraction. The elution was performed with acetonitrile and the samples were reconstituted in the mobile phase. Isocratic high-performance liquid chromatography analysis was performed by injecting 50 microL of reconstituted material onto a 100 x 3.00 mm C12 column with a methanol:1% trifluoroacetic acid/ammonium trifluoroacetate in H(2)O 70:30 mobile phase at 350 microL/min. The [M+H](+) ions generated in the sonic spray ionization interface were isolated and fragmented using two serial mass spectrometric methods: one for paclitaxel (transition 854 --> 569 & 551) and the dihydroxymetabolite (transition 886 --> 585 & 567) and one for the hydroxy metabolites (transition 870 --> 585 & 567; transition 870 --> 569 & 551) and docetaxel ([M+Na](+), transition 830 --> 550). Calibration curves were created ranging between 0.5 and 7500 ng/mL for paclitaxel, 0.5 and 750 ng/mL for 6alpha-hydroxypaclitaxel, and 0.5 and 400 ng/mL for p-3'-hydroxypaclitaxel. Adduct ion formation was noted and investigated during method development and controlled by mobile phase optimization. In conclusion, a sensitive method for simultaneous quantification of paclitaxel and its metabolites suitable for analysis in clinical studies was obtained.  相似文献   

4.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of docetaxel and ketoconazole in rat plasma with paclitaxel as internal standard (IS). The analytes were extracted from rat plasma by using a liquid-liquid extraction technique with ethyl acetate and the LC separation was performed on a Cosmosil-C(18) analytical column (150 mm x 2.0 mm i.d., Nacalai Tesque Inc., Japan). The extracted samples were analyzed with LC/MS/MS, operating in selected reaction monitoring (SRM) mode. The SRM transitions of precursor ions to product ions were 830.3-->549.1 (m/z) for docetaxel, 531.2-->489.3 (m/z) for ketoconazole, and 876.7-->307.9 (m/z) for the IS. The calibration curves were linear over the range of 2-500 ng/mL for docetaxel and 50-20 000 ng/mL for ketoconazole, with coefficients of correlation above 0.999. The limits of quantification for docetaxel and ketoconazole were both 2 ng/mL. The limit of detection for each analyte was 1 ng/mL. The intra- and inter-day precision (CV) of analysis were within 7%, and the accuracy ranged from 95 to 110%. The overall recoveries for docetaxel and ketoconazole were about 89.0% and 91.1%, respectively. The total analysis time was only 9.0 min. This quantitation method was successfully applied to the simultaneous determination of docetaxel and ketoconazole in rat plasma and some potential interaction was found in the current coadministration pharmacokinetic study. This established method was also utilized in the in vitro and in vivo drug-drug interaction study of docetaxel and ketoconazole (to be published).  相似文献   

5.
A sensitive, specific and reliable liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed for simultaneous determination of D-amino acids in the central nervous system (CNS) of Aplysia californica. In order to correct for any potential matrix effects on measured signals, deuterium-labeled L-Asp-d3 was used as an internal standard. Pre-column derivatization of the sample with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) allowed both effective in-line pre-concentration and sensitive MS/MS detection of the analytes. An extraction column (50x0.25 mm, 5 microm C18 silica particles) was used to pre-concentrate/stack samples. Enantiomeric separation of amino acid enantiomers was achieved on a chiral column packed with teicoplanin aglycone bonded silica particles (170x0.25 mm, 5 microm) with an MS-friendly mobile phase. The characteristic precursor to product ion transitions, m/z 297-->279 (for NBD-Asp), m/z 269-->223 (For NBD-Ser), m/z 311-->293 (for NBD-Glu) and m/z 300-->282 (for NBD-L-Asp-d3) were monitored for the quantification. Samples from the CNS of A. californica and heart tissues were analyzed. D-Asp was detected at high levels in all the ganglia and nerve tissues, but not in the heart tissue. Further, neither D-Ser nor D-Glu was detected in Aplysia, a widely used neuronal model.  相似文献   

6.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

7.
A method was developed for the quantitation of pentoxifylline [1-(5-oxohexyl)-3,7-dimethylxanthine] and a primary active metabolite, lisofylline [1-(5-hydroxyhexyl)-3,7-dimethylxanthine], using high-performance liquid chromatography (HPLC)-tandem mass spectrometry. This method was developed in order to overcome problems encountered with HPLC-ultraviolet detection. The operating parameters of the electrospray interface (PE SCIEX, TurboIon Spray) and lens voltages of the triple-quadrupole detector (PE SCIEX 365) were optimized in positive ion mode to obtain the best sensitivity of the analytes. Collision-induced dissociation was used to produce fragment ions, and multiple reaction monitoring was used to quantitate pentoxifylline (m/z 279/181) and lisofylline (m/z 263/181). Dichloromethane was used to extract the drug, metabolite, and the internal standard (3-isobutyl-1-methylxanthine) from plasma. A reverse-phase C8(2) 150 x 1.0 mm HPLC column was used to resolve all three compounds in less than 6 min. Calibration curves were generated using peak area and were linear from 1 to 1000 ng/mL (R(2) > 0.99). The small sample volume, ease of extraction, and sensitivity provide advantages over more conventional methods of quantitation.  相似文献   

8.
A method is described for the determination of residues of the illegal antibiotic chloramphenicol (CAP) in milk powders. The analyte is quantified by liquid chromatography coupled to electrospray ionisation tandem mass spectrometry (LC-ESI-MS-MS) operating in negative ion multiple reaction monitoring mode (MRM) after a liquid-liquid extraction followed by a clean-up step on solid phase extraction (SPE) cartridge. Because of the presence of two chlorine atoms in the CAP molecule, four specific transition reactions of CAP were monitored by MS-MS in selecting m/z 321 --> 257, 321 --> 152 (35Cl2) and m/z 323 --> 257, 323 --> 152 (37Cl35Cl). Two calibration curves were constructed by plotting the area ratio of m/z 321 --> 152 versus 326 --> 157 and m/z 321 --> 257 versus 326 --> 262 against their corresponding amount ratio. Indeed, even if m/z 321 --> 152 was found to give a higher MS-MS response (calibration curve used by default), an interfering chemical substance was sometimes observed for some milk extracts and not for the transition m/z 321 --> 257. The quantitation method was validated according to the European Union (EU) criteria for the analysis of veterinary drug residues at 0.1, 0.2 and 0.5 microg/kg concentration levels using d5-CAP as internal standard. The decision limit (CCalpha) and detection capability (CCbeta) of CAP in milk were calculated for m/z 321 --> 152 at 0.02 microg/kg and 0.03 microg/kg, respectively, and for m/z 321 --> 257 at 0.02 microg/kg and 0.04 microg/kg, respectively. At the lowest fortification level (i.e. 0.1 microg/kg), repeatability and within-laboratory reproducibility were calculated for m/z 321 --> 257 both at 0.02 microg/kg and for m/z 321 --> 152 at 0.03 and 0.05 microg/kg, respectively. Moreover, the measurement of uncertainty of the analytical method was calculated at the same spiking levels and falls within the precision values of the within-laboratory reproducibility. This method can be applied to several types of milk powders (e.g. full cream, skim) and can serve as a monitoring tool to avoid that unacceptable levels of residues of CAP enter the food chain.  相似文献   

9.
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of 2-methoxyestradiol (2ME2) in human plasma. Sample pretreatment involved liquid-liquid extraction with ethyl acetate of 0.3-mL aliquots of plasma spiked with the internal standard, deuterated 2ME2 (2ME2-d5). Separation was achieved on a Zorbax Eclipse C18 column (2.1 x 50 mm, i.d., 5 microm) at room temperature using a gradient elution with methanol and water at a flow rate of 0.25 mL/min. Detection was performed using atmospheric pressure chemical ionization MS/MS by monitoring the ion transitions from m/z 303.1 --> 136.8 (2ME2) and m/z 308.1 --> 138.8 (2ME2-d5). Calibration curves were linear in the concentration range of 1-100 ng/mL. The accuracy and precision values, obtained from three different sets of quality control samples analyzed in quintuplicate on four separate occasions, ranged from 105-108% and from 3.62-5.68%, respectively. This assay was subsequently used for the determination of 2ME2 concentration in plasma of a patient with cancer after a single oral administration of 2ME2 at a dose of 2200 mg.  相似文献   

10.
A novel method has been developed for simultaneous analysis of paclitaxel (PTX) and retinoic acid (ATRA) in mice plasma and tissue homogenates. The analyte was isolated by liquid?Cliquid partitioning, to minimize analyte degradation, and fractions were analyzed by liquid chromatography?Cmass spectrometry (LC?CMS). Liquid?Cliquid extraction with tert-butyl methyl ether was used for sample preparation and docetaxel was used as internal standard (IS). Separation of PTX, ATRA, and the IS was performed on a C18 column with gradient elution and detection by use of a single-quadrupole mass spectrometer in selected-ion-monitoring mode. The method had high extraction recovery (>85%) and accuracy (>90%), with intra-day and inter-day precision <15%, and was rugged with good linearity. The limits of quantitation were determined to be 2 and 4 ng mL?1 for PTX and ATRA, respectively. Freeze?Cthaw stability, short-term stability, long-term stability, and sample stability in the autosampler tray were examined; this indicated freezing and thawing during bio-sample preparation should be avoided, but no other stability-related problems occurred during sample storage, extraction, and chromatography of PTX and ATRA in plasma and tissue samples. The assay was successfully used for simultaneous analysis of PTX and ATRA in mice plasma and different tissues to support pharmacokinetic and in-vivo distribution studies of the two drugs.  相似文献   

11.
A simple, sensitive, and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method, using electrospray ionization, was developed and validated to quantify trimetazidine in human plasma using propranolol hydrochloride as an internal standard (IS). Samples were prepared by solid-phase extraction and analyzed without drying and reconstitution. The analyte and IS were chromatographed on a C18 reversed-phase column under isocratic conditions using 2 mM ammonium acetate (pH 3.5)-acetonitrile (40 + 60, v/v) as the mobile phase with a run time of 2.0 min. Quantitation was done on a triple-quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring mode to detect parent --> product ion (m/z 267.2 --> 181.4) transition. The method was validated for sensitivity, accuracy and precision, linearity, recovery, matrix effect, and stability. Linearity in plasma was observed over the concentration range of 1.5-300 ng/mL. Lower limit of quantification achieved was 1.5 ng/mL with precision < 10% using 10 microL injection volume. The mean relative recovery of analyte (97.36%) and IS (99.93%) was consistent and reproducible. Interbatch and intrabatch precision was < 8.0% and the accuracy determined was within +/- 8% in terms of relative error.  相似文献   

12.
A simple, sensitive and rapid high-performance liquid chromatography/negative electrospray ionization tandem mass spectrometry method was developed and validated for the assay of aranidipine (AR) and its active metabolite (AR-M) in human plasma. Following a liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M-H]- ions, m/z 387.0 --> 164.0 for AR, m/z 389.1 --> 208.1 for AR-M and m/z 359.0 --> 121.8 for the internal standard. The assay exhibited a linear dynamic range of 0.02-10 ng x mL(-1) for AR and 0.2-100 ng x mL(-1) for AR-M in human plasma. The limits of quantitation were 0.02 ng x mL(-1) for AR and 0.2 ng x mL(-1) for AR-M. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.8 min for each sample exhibited its high-throughout analysis ability. The validated method can be applied to analyze human plasma samples for pharmacokinetic studies.  相似文献   

13.
A new method for simultaneous determination of amiloride and hydrochlorothiazide by liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) operated in positive and negative ionization switching mode was developed and validated. Protein precipitation with acetonitrile was selected for sample preparation. The analytes were separated on a Phenomenex Curosil-PFP (250x4.6 mm, 5 microm) column by a gradient elution with a mobile phase consisting of 0.15% formic acid solution containing 0.23% ammonium acetate and methanol pumped at a flow rate of 1.0 mL.min(-1). Rizatriptan was used as the internal standard (IS) for quantification. The determination was carried out on a Waters Quattro-micro triple-quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using the following transitions monitored simultaneously: positive m/z 230-->171 for amiloride, m/z 270-->158 for rizatriptan, and negative m/z 296-->205 for hydrochlorothiazide. The lower limits of quantification (LLOQs) were 0.1 and 1.0 ng.mL(-1) for amiloride and hydrochlorothiazide, respectively, which were lower than other published methods by using ultraviolet (UV), fluorimetric or mass spectrometric detection. The intra- and inter-day precision and accuracy were studied at three different concentration levels and were always better than 15% (n=5). This simple and robust LC/MS/MS method was successfully applied to the pharmacokinetic study of compound amiloride and hydrochlorothiazide tablets in healthy male Chinese volunteers.  相似文献   

14.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

15.
A novel, rapid and sensitive isocratic liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for quantification of docetaxel in human plasma with paclitaxel as internal standard. The high sensitivity and specificity of MS/MS detection enabled the use of a small volume of plasma (0.05 mL) and a simple liquid-liquid extraction procedure. Furthermore, a very short run-time (3 min) fulfilled the need for monitoring plasma levels of docetaxel from large-scale clinical studies. The calibration curve for docetaxel was linear over the range 5-1000 ng/mL with coefficients of correlation >0.999 using only 0.05 mL plasma. The intra- and inter-day precisions (CV) of analysis were <7%, and accuracy ranged from 96 to 110%. The applicability of the method was demonstrated in a pharmacokinetic study of a 1-h infusion of docetaxel with dosages of 75 mg/m(2). Possible conjugated metabolites of docetaxel were not detected in patients' samples.  相似文献   

16.
An LC-MS/MS method for the simultaneous determination of a new P-glycoprotein inhibitor 4-oxo-4H-chromene-2-carboxylic acid [2-(2-(4-[2-(6,7-dimethoxy-3,4-dihydro-1H-isoquinolin-2-yl)-ethyl]-phenyl)-2H-tetrazol-5-yl)-4,5-dimethoxy-phenyl]-amide (HM-30181) and a P-glycoprotein substrate paclitaxel in rat plasma was developed to simultaneously evaluate the pharmacokinetics of paclitaxel and HM-30181 in the rats. HM-30181, paclitaxel, HM-30059 (internal standard (I.S.) for HM-30181), and docetaxel (I.S. for paclitaxel) were extracted from rat plasma with methyl-tert-butyl ether and analyzed on an Atlantis C18 column (5 microm, 2.1 x 100 mm) with the mobile phase of ACN/10 mM ammonium formate (75:25 v/v). The analytes were detected using an ESI MS/MS in the multiple reaction monitoring (MRM) mode. The standard curves for HM-30181 and paclitaxel in plasma were linear (r > 0.999) over the concentration range of 2.0-500 ng/mL with a weighting of 1/concentration2. The method showed a satisfactory sensitivity (2 ng/mL using 50 microL plasma), precision (CV: < or = 6.6%), accuracy (relative error: -6.3 to 2.0%), and selectivity. This method was successfully applied to the pharmacokinetic study of HM-30181 and paclitaxel in rat plasma after oral-coadministration of paclitaxel and HM-30181 to male Sprague- Dawley rats.  相似文献   

17.
A sensitive, specific, and reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for detection and identification of zeranol in chicken or rabbit liver. A homogenized liver sample was hydrolyzed with beta-glucuronidase/arylsulfatase, and the hydrolysate was extracted with ethyl ether. The supernatant was evaporated to dryness, and the residue was dissolved in chloroform and re-extracted with sodium hydroxide. After acidification, the extract was cleaned up on a C18 solid-phase extraction cartridge and analyzed by electrospray LC-MS/MS in the negative ion mode. The multiple reaction monitoring transition from both m/z 321 to 277 and m/z 321 to 303 was monitored for confirmation, and the product ion of 277 was used for quantitation. Separation was performed on a Waters XTettra C18 column (50 x 2.1 mm, 3.5 microm) combined with a safeguard column (Symmetry C18, 20 x 3.9 mm, 5 microm), using a gradient elution with acetonitrile and 20 mM ammonium acetate. Calibration curves were prepared and good linearity was achieved over the concentration ranges tested. For all liver samples fortified at 3 different levels of 1, 5, and 50 microg/kg, the overall recoveries and relative standard deviations were in the range of 61-90 and 8-13%, respectively. The limit of quantitation based on the assay validation was 1 microg/kg. The method had been used on a routine basis for detection and identification of zeranol in liver samples.  相似文献   

18.
A rapid and sensitive method for the quantitation of buspirone in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed. Plasma samples were treated by liquid-liquid extraction with methyl tert-butyl ether (MTBE). The chromatographic separation was performed isocratically on a reversed-phase Shiseido C18 column (50 mm x 2.0 mm, 3 microm) with a mobile phase of acetonitrile/0.1% acetic acid (1:1, v/v). The acquisition was performed in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 386 --> 122 for buspirone and m/z 409 --> 238 for amlodipine (the internal standard). The method was validated to determine its specificity, recovery, limit of quantitation, accuracy and precision. The lower limit of quantitation was 0.02 ng/mL with a relative standard deviation of less than 10%. The present method provides an accurate, precise and sensitive tool for buspirone and was successfully applied to a pharmacokinetic study in eight subjects.  相似文献   

19.
A confirmatory method based on isotope dilution liquid chromatography-electrospray ionization tandem mass spectrometry is described for the determination of the antibiotic chloramphenicol (CAP) in foods. The method is quantitative and entails liquid-liquid extraction followed by a clean-up step on a silica gel solid-phase extraction cartridge. Mass spectral acquisition is done in the negative ion mode applying multiple reaction monitoring of two diagnostic transition reactions for CAP (m/z 321 --> 257 and m/z 321--> 152). In addition, the presence of two chlorine atoms in the CAP molecule provides further analyte certainty by assessing the 37Cl/35Cl ratio using the transition reactions m/z 323 --> 257 and m/z 323 --> 152. Validation of the method in chicken meat is conducted according to the latest European Union criteria for the analysis of veterinary drug residues at levels of 0.05, 0.10, and 0.20 microg/kg, employing [2H5]-chloramphenicol as internal standard. The decision limit and the detection capability were calculated at 0.01 microg/kg and 0.02 microg/kg, respectively. At the lowest fortification level (i.e. 0.05 microg/kg), precision values below 14 and 17% were achieved under repeatability and within-laboratory reproducibility conditions, respectively. The accuracy of the method was within 20, 15, and 5% of the target values at the 0.05, 0.10, and 0.20 microg/kg fortification levels, respectively. The applicability of this procedure was demonstrated by the analysis of other meat (turkey, pork, beef) and seafood (fish, shrimps) products. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.  相似文献   

20.
Delta9-tetrahydrocannabinolic acid A (Delta9-THCA-A) is the precursor of Delta9-tetrahydrocannabinol (Delta9-THC) in hemp plants. During smoking, the non-psychoactive Delta9-THCA-A is converted to Delta9-THC, the main psychoactive component of marihuana and hashish. Although the decarboxylation of Delta9-THCA-A to Delta9-THC was assumed to be complete--which means that no Delta9-THCA-A should be detectable in urine and blood serum of cannabis consumers--we found Delta9-THCA-A in the urine and blood serum samples collected from police controls of drivers suspected for driving under the influence of drugs (DUID). For LC-MS/MS analysis, urine and blood serum samples were prepared by solid-phase extraction. Analysis was performed with a phenylhexyl column using gradient elution with acetonitrile. For detection of Delta9-THCA-A, the mass spectrometer (MS) (SCIEX API 365 triple-quadrupole MS with TurboIonSpray source) was operated in the multiple reaction monitoring (MRM) mode using the following transitions: m/z357 --> 313, m/z357 --> 245 and m/z357 --> 191. Delta9-THCA-A could be detected in the urine and blood serum samples of several cannabis consumers in concentrations of up to 10.8 ng/ml in urine and 14.8 ng/ml in serum. The concentration of Delta9-THCA-A was below the Delta9-THC concentration in most serum samples, resulting in molar ratios of Delta9-THCA-A/Delta9-THC of approximately 5.0-18.6%. Only in one case, where a short elapsed time between the last intake and blood sampling is assumed, the molar ratio was 18.6% in the serum. This indicates differences in elimination kinetics, which need to be investigated in detail.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号