首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
S. C. Rastogi 《Chromatographia》1993,37(3-4):211-214
Summary A gas chromatographic method for the analysis of organic solvents in chemical products is described. The analysis is performed by the use of a polar column, Supelcowax 10, and a non-polar column CP-Sil-5CB. Samples containing a non-volatile matrix or water were analysed by headspace analysis. The identification of the solvents in a sample, based on GC retention times on one column, is confirmed by GC of the sample on the second column. The method has been found to be suitable for the routine analysis of solvent mixtures.  相似文献   

2.
3.
Relationships in variation of the surface energy of polystyrene coatings on melted quartz at varied polymer concentration in solution were refined by studying the functional chemical composition and surface structure of model coatings of atactic polystyrene on quartz plates and the electromigration properties of capillary columns with polystyrene coatings. The optimum concentration and temperature-kinetic conditions for preparing polystyrene coatings on quartz capillaries with controllable electrokinetic properties were determined.  相似文献   

4.
Preparation of monolithic capillary columns for separations in the CEC mode using UV-initiated polymerization of the plain monolith followed by functionalization of its pore surface by photografting has been studied. The first step enabled the preparation of generic poly(butyl methacrylate-co-ethylene dimethacrylate) monoliths with optimized porous properties, controlled by the percentages of porogens 1-decanol and cyclohexanol in the polymerization mixture, irradiation time, and UV light intensity. Ionizable monomers [2-(methacryloyloxy)ethyl]trimethylammonium chloride or 2-acryloamido-2-methyl-1-propanesulfonic acid were then photografted onto the monolithic matrix, allowing us to control the direction of the EOF in CEC. Different strategies were applied to control the grafting density and, thereby, the magnitude of the EOF. To control the hydrophobic properties, two approaches were tested: (i) cografting of a mixture of the ionizable and hydrophobic monomers and (ii) sequential grafting of the ionizable and hydrophobic monomers. Cografting resulted in similar retention but higher EOF. With sequential grafting, more than 50% increase in retention factors was obtained and a slight decrease in EOF was observed due to shielding of the ionizable moieties.  相似文献   

5.
6.
7.
Fused‐silica capillary columns for high‐performance liquid chromatography with 320 and 250 μm inner diameter were prepared by slurry packing with 5 and 3 μm Nucleosil C18 stationary phase. Different types of mechanical and monolithic outlet frits were used and their influence on the resulting column performance was evaluated. Columns with quartz wool exhibited symmetrical peaks and low theoretical plate height, and the preparation time was short. The performance of monolithic frits varied based on type of monolith, length of the frit, and silanization procedure. The best frit performed similarly to the quartz wool ones, but the preparation took several hours. Their main advantage lies in the possibility of on‐column detection, because the detection window can be burnt immediately behind the frit.  相似文献   

8.
9.
Capillary columns of 0.3-0.5 mm i.d. packed with 3- to 30-μm silica-based stationary phases for liquid chromatography were used for gas chromatographic separation of hydrocarbons. Column efficiencies were evaluated for various commercially available packing material. The best column efficiency was achieved with 5-μm octadecyl group bonded silica gel, the surface of which was coated with a poly (dimethylsiloxane) film. The 30-cm column produced 11,000 theoretical plates.  相似文献   

10.
A comparison of the characteristics and Performance of the flame ionization, electron capture, and flame photometric detectors with capillary columns is described. Factors which may affect the limits of detection, linearity, chromatographic peak shape, and other detector performance characteristics are discussed and compared with the results of a model derived for the behavior of concentration and mass flow-rate dependent chromatographic detectors used with capillary GC systems. Examples are given of highly complex and labile mixtures such as pesticide residues and products from coal hydrogenation.  相似文献   

11.
Apart from extracolumn effects peak dispersion in liquid chromatographic columns is caused by the column inlet, the packed bed, and the column outlet. A strategy applicable for independent evaluation of the individual sources of column band broadening was developed on the basis of the linear extrapolation method (LEM). This method was applied to compare the performance of packed capillary LC columns from various commercial suppliers with conventional-size columns. The columns differed widely in their performance with respect to peak shapes and widths for standard substances. The capillary columns were found well packed, but in some cases overall performance would benefit from improving the design of the area between the packed bed and the connecting capillaries, containing frits as well as dead volumes.  相似文献   

12.
Dynamically modified open tubular capillary columns were evaluated for separations of biological and clinical interest. Small diameter, dynamically modified columns were readily prepared by simple addition of cetyltrimethylammonium salts to the mobile phase. Separations similar to those obtained on conventional reversed-phase columns were observed for neutral solutes, and ion-pair reversed-phase separations were observed for charged solutes. Borosilicate and standard flint glasses were evaluated with respect to common etching procedures. A potential clinical application is presented in the separation of antitumor drugs.  相似文献   

13.
Porous monoliths based on N,N-dimethylacrylamide (DMAA) or methacrylamide (MAA) were prepared inside fused silica capillaries as stationary phases for nano-chromatography. The columns were characterized in terms of flow rate and backpressure and showed, e.g. differences as a function of the salt concentration added to the polymerization mixture. When the columns were investigated for the separation of uncharged (polar hydroxylated aromatic compounds) and charged (amino acids) analytes under pressure driven conditions (pLC), differences to the previously observed behavior under voltage driven conditions (CEC) were observed. Whereas the non-charged analytes showed similar behavior in both cases--thus, corroborating the previous assumption of a mainly chromatographic separation mode driven by hydrophilic interactions in CEC--the charged amino acids did not. Assuming that the separation was governed by chromatographic phenomena in the pLC mode and by both chromatographic and electrophoretic effects in the CEC mode, the experiments allowed deconvoluting the two contributions. In particular, the charged amino acids appeared to interact with the stationary phases mainly by electrostatic interactions modified by some hydrophilic effects.  相似文献   

14.
近年国内外毛细管气相色谱柱的进展和趋向   总被引:3,自引:1,他引:3  
报道了近两年毛细管气相色谱柱的发展和趋向. 气相色谱柱制柱工艺是一个成熟的技术, 所以在制柱工艺方面的研究不够活跃. 近年新研究的固定相集中在常温离子液体和各种环糊精的衍生物. 近几年GC毛细管色谱柱的研究和改进集中在色谱柱厂家进行, 并立即成为商品柱. 本文对近两年一些重要期刊上发表的气相色谱论文进行了总结, 发现气相色谱分析所用的色谱柱大都使用毛细管柱, 并趋向于使用商品GC毛细管柱, 所使用的商品色谱柱中, 使用最多的是以含5%苯基的聚甲基硅氧烷做固定相的色谱柱, 其次是以100%甲基的聚硅氧烷做固定相的色谱柱. 极性毛细管色谱柱主要使用PEG、 OV-17和OV-1701固定相.  相似文献   

15.
In this paper general considerations related to the various approaches and parameters influencing the preparation of highly efficient and stable capillary columns for use in liquid chromatography and related techniques are presented and the column production process is discussed in some detail. The different packing methods available for delivering a packing material into a capillary column are discussed from a practical viewpoint. Packing with a gas (dry packing), packing with a liquid solvent or a mixture of solvents (slurry packing), packing with supercritical carbon dioxide, electrokinetic packing, and sol-gel packing technologies are introduced and discussed throughout the paper. Practical recommendations for obtaining highly efficient (high plate numbers) and stable capillary packed columns are also addressed and discussed.  相似文献   

16.
Sugars were separated gas chromatographically on short apolar glass capillary columns by using cold, on-column injection (OCI) techniques. After silylation, oligomers up to the hexasaccharides could be efficiently separated in resonable retention times. Response factors of silylated sugars were determined as a function of varying sample amounts and concentrations. The optimum injection amount was found to be 1 μl in heptane as solvent.  相似文献   

17.
Enantioseparations of racemic nonsteroidal anti-inflammatory drugs (naproxen, ibuprofen, ketoprofen, flurbiprofen, suprofen, indoprofen, cicloprofen, and carprofen) were performed by nano-liquid chromatography, employing achiral capillary columns and heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin (TM-β-CD) or hydroxylpropyl-β-cyclodextrin (HP-β-CD) as a chiral mobile phase additive (CMPA). Working under the same experimental conditions (in terms of mobile phase and linear velocity), the performance of a RP-C18 monolithic column was compared with that of a RP-C18 packed column of the same dimensions (100 μm i.d. × 10 cm). Utilizing a mobile phase composed of 30% ACN (v/v) buffered with 50 mM sodium acetate at pH 3, and containing 30 mM TM-β-CD, the monolithic column provided faster analysis but lower resolution than the packed column. This behavior was ascribed to the high permeability of the monolithic column, as well as to its minor selectivity. HP-β-CD was chosen as an alternative to TM-β-CD. Employing the monolithic column, the effects of different parameters such as HP-β-CD concentration, mobile phase composition, and pH on the retention factor and the chiral resolution of the analytes were studied. For the most of the analytes, enantioresolution (which ranged from R s = 1.80 for naproxen to R s = 0.86 for flurbiprofen) was obtained with a mobile phase consisting of sodium acetate buffer (25 mM, pH 3), 10% MeOH, and 15 mM HP-β-CD. When the same experimental conditions were used with the packed column, no compound eluted within 1 h. Upon increasing the percentage of organic modifier to favor analyte elution, only suprofen eluted within 30 min, with an R s value of 1.14 (20% MeOH). Replacing MeOH with ACN resulted in a loss of enantioresolution, except for naproxen (R s = 0.89).  相似文献   

18.
In the present study, the composition of the hop strobilus extract by using different extraction methods under different solvent conditions was analysed and compared. Several separation methods were applied to obtaining detailed information about the hop extract: capillary zone electrophoresis (CZE), high-performance liquid chromatography-mass-spectrometry (HPLC-MS/MS) and gas chromatography-mass-spectrometry (GC-MS). The electropherograms of different extracts varied dramatically. The oxidation reaction of the hop strobilus extract was examined.  相似文献   

19.
A study was carried out in which 50 microm I.D. fused-silica capillaries were packed with 3 microm octadecylsilane bonded silica, from the same batch, by four methods; liquid slurry and carbon dioxide supercritical carrier, each with and without the use of an ultrasonic probe. A neutral test mixture was analysed by capillary column in reversed-phase mode, and the reproducibility of the electroosmotic flow and of migration time, column efficiency and retention factors, was determined. Initially results suggested that there was no significant difference between properties of columns packed by different methods, and a more thorough statistical evaluation confirmed this; differences observed in the column performance were attributed to random variations between replicate columns, and not between packing methods. However, the variation was least when applying the ultrasonication during liquid slurry.  相似文献   

20.
Relative polarity values and retention indices for a mixture of normal paraffins C5–C10 and alkylbezenes C6–C9 are determined for four types of monolithic capillary columns based on divinylbenzene, ethylene glycol dimethacrylate, pentaerythritol tetraacrylate, and pentaerythritol triacrylate. It is established that the retention of polar sorbates increases with a rise in stationary phase polarity, while the retention of nonpolar compounds grows with a reduction in stationary phase polarity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏