首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Boland S  Leech D 《The Analyst》2012,137(1):113-117
Highly ordered macroporous electrodes are prepared by electro-deposition of gold through a polystyrene sphere template. Drop-coating redox polymer and either glucose oxidase, for the anode, or Melanocarpus albomyces laccase, for the cathode on the macroporous gold provides film-coated electrodes for assembly of membrane-less glucose/oxygen enzymatic fuel cells (EFC) in pH 7.4 buffer containing 10 mM glucose and 0.15 M NaCl. Under these conditions the maximum power density of 17 μW cm(-2) for EFCs using films adsorbed to planar gold electrodes increased to 38 μW cm(-2) for films adsorbed to 2? sphere gold macroporous electrodes.  相似文献   

2.
《Electroanalysis》2006,18(24):2397-2404
Interfacial assemblies capable of determining glutamate by redox catalysis are prepared by electrostatic assembly of alternating layers of ferrocene poly(allylamine) polymer and glutamate oxidase on a gold electrode. Deposition of the polymer was confirmed in cyclic voltammetry measurements by the presence of a surface wave corresponding to the oxidation of the ferrocene group. In the presence of glutamate in the adjacent electrolyte solution, the current increases and approaches a pseudosteady state, consistent with redox catalysis. Electrodes modified with glutamate oxidase had a linear response to glutamate up to 0.0045 M with sensitivity of 20 μA/cm2 and a limit of detection of 31.4 μM glutamate. An apparent Michaelis–Menten constant of 0.40(±0.13) mM for the confined glutamate oxidase was determined for this assembly. When used in flow‐injection experiments, glucose oxidase modified electrodes responded to transient zones of glucose; however, the detection limits of the assemblies to the flowing stream were substantially higher than found for measurements on static solutions.  相似文献   

3.
Dawson K  Baudequin M  O'Riordan A 《The Analyst》2011,136(21):4507-4513
The development of glucose diagnostic devices with low detection limits is of key importance in diabetes-related research. New highly sensitive sensors are required for non-invasive detection of glucose in bodily fluids, other than blood, and an electrochemical sensor based on a single gold nanowire for rapid, reliable and quantitative detection of low glucose concentrations (10 μM-1 mM), is presented in this paper. Single gold nanowire devices are fabricated at silicon chip substrates using a hybrid electron beam-photolithography approach. Critical dimensions of the nanowires are characterised using a combination of scanning electron and atomic force microscopies. Fabricated nanowire devices are characterised by direct electrical probing and cyclic voltammetry to explore functionality. The voltammetric detection of glucose was performed using ferrocene monocarboxylic acid as an oxidising mediator in the presence of glucose oxidase. The biosensor can be applied to the quantification of glucose in the range of 10 μM-100 mM, with an extremely high sensitivity of 7.2 mA mM(-1) cm(-2) and a low detection limit of 3 μM (S/N = 3). The sensor demonstrated high selectivity towards glucose with negligible interference from other oxidizable species including uric acid, ascorbic acid, mannose, fructose, salicylic acid (Aspirin) and acetaminophen (Paracetamol).  相似文献   

4.
An amperometric glucose biosensor on layer by layer assembled carbon nanotube and polypyrrole multilayer film has been reported in the present investigation. Homogeneous and stable single wall carbon nanotubes (SWNTs) and polypyrrole (PPy) multilayer films were alternately assembled on platinum coated Polyvinylidene fluoride (PVDF) membrane. Since conducting polypyrrole has excellent anti‐interference ability, protection ability in favor of increasing the amount of the SWNTs on platinum coated PVDF membrane and superior transducing ability, a layer by layer approach of polypyrrole and carbon nanotubes has provided an excellent matrix for the immobilization of enzyme. The layer‐by‐layer assembled SWNTs and PPy‐modified platinum coated PVDF membrane is shown to be an excellent amperometric sensor over a wide range of concentrations of glucose. The glucose oxidase (GOx) was immobilized on layer by layer assembled film by a physical adsorption method by cross linking through Glutaraldehyde. The glucose biosensor exhibited a linear response range from 1 mM to 50 mM of glucose concentration with excellent sensitivity of 7.06 μA/mM.  相似文献   

5.
A glucose oxidase (GOd) bioelectrode exhibiting high performance, direct electron transfer (DET) has been prepared. Unprecedented redox peak current densities of 1 mA cm(-2) were observed alongside a clear electrochemical response to glucose. This system shows potential as a low cost, high performance enzymatic bioelectrode.  相似文献   

6.
A single-step fabrication of a glucose biosensor with simultaneous immobilization of both ferrocene mediator and glucose oxidase in a photocurable methacrylic film consisting of poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) was reported. The entrapped ferrocene showed reversible redox behaviour in the photocured film and no significant leaching of both entrapped ferrocene and enzyme glucose oxidase was observed because of the low water absorption properties of the co-polymer films. From electrochemical studies, ferrocene entrapped in the co-polymer film demonstrated slow diffusion properties. A linear glucose response range of 2-11 mM was obtained at low applied potential of +0.25 V. The glucose biosensor fabricated by this photocuring method yielded sensor reproducibility and repeatability with relative standard deviation of <10% and long-term stability of up to 14 days. The main advantage of the use of photocurable procedure is that biosensor membrane fabrication can be performed in a single step without any lengthy chemical immobilization of enzyme.  相似文献   

7.
A redox hydrogel with an apparent electron diffusion coefficient (D(app)) of (5.8 +/- 0.5) x 10(-)(6) cm(2) s(-)(1) is described. The order of magnitude increase in D(app) relative to previously studied redox hydrogels results from the tethering of redox centers to the backbone of the cross-linked redox polymer backbone through 13 atom spacer arms. The long and flexible tethers allow the redox centers to sweep electrons from large-volume elements and to collect electrons of glucose oxidase efficiently. The spacer arms make the collection of electrons from glucose oxidase so efficient that glucose is electrooxidized already at -0.36 V versus Ag/AgCl, the reversible potential of the redox potential of the FAD/FADH(2) centers of the enzyme at pH 7.2. The limiting current density of 1.15 mA cm(-)(2) is reached at a potential as low as -0.1 V versus Ag/AgCl. The novel redox center of the polymer is a tris-dialkylated N,N'-biimidazole Os(2+/3+) complex. Its redox potential, -0.195 V versus Ag/AgCl, is 0.8 V reducing relative to that of Os(bpy)(2+/3+), its 2,2'-bipyridine analogue.  相似文献   

8.
Ferrocene redox polymers based on the coupling of ferrocenecarboxaldehyde to both linear and branched poly(ethylenimine) (PEI) have been prepared to investigate the effects of pH, electrolyte, and cross-linking on electron charge transport and film swelling. The redox behavior of both ferrocene-modified linear PEI and ferrocene-modified branched PEI was investigated by cyclic voltammetry, while electron diffusion coefficients reported for PEI-based redox polymers were determined by electrochemical impedance spectroscopy. In phosphate solutions at pH>7, cross-linked films of both redox polymers exhibited multiple redox wave behavior and were unstable. In contrast, in non-phosphate solutions, cross-linked films exhibited stable electrochemical behavior and fast electron transfer in solutions with pH<11. Gel swelling experiments suggested that the multiple wave behavior and instability exhibited in either phosphate solutions or at high pH in non-phosphate solutions were related to a combination of film collapse and electrolyte binding within the hydrogel. The electron diffusion coefficients for these polymers are on the order of 10-8 (mol cm(-2) s(-1/2)), which are approximately 40 times greater than other ferrocene-modified polymers. Incorporation of the enzyme, glucose oxidase, into these films demonstrated that these redox polymers were able to electrically communicate with the enzyme's flavin adenine dinucleotide (FAD) redox centers. Glucose sensors based on these films exhibited enzyme saturation current densities that ranged from 240 to 480 microA/cm2 in response to glucose, which were dependent upon the supporting electrolyte and pH. The sensitivity of these sensors at 5 mM glucose ranged from 10 to 48 microA.cm(-2).mM(-1).  相似文献   

9.
含二茂铁离子液体电容器的电化学性能   总被引:1,自引:0,他引:1  
对以含二茂铁(ferrocene, Fc)离子液体1-乙基-3-甲基咪唑四氟硼酸盐(1-ethyl-3-methylimidazolium tetra-fluoroborate, [BMIm]BF4)作为电解液, 高比表面积的多孔炭作为电极材料构成的电容器的电化学行为进行了探讨. 循环伏安和恒流充放电测试结果表明,含二茂铁离子液体在多孔炭中发生氧化还原反应, 并且该氧化还原反应是扩散控制, 高度可逆的过程. 0.01 mol·L-1 [BMIm]BF4/Fc在电流密度为1 mA·cm-2时的平均比电容为163 F·g-1, 比纯[BMIm]BF4的比电容高63%. 平均比电容的增加表明由Fc参与的氧化还原反应生成的法拉第电容对电容器的总电容有很大的贡献. 同时, 以0.01 mol·L-1 [BMIm]BF4/Fc作电解液的电容器的功率密度为400 W·kg-1, 能量密度高达37.5 Wh·kg-1, 达到了电池的水平.  相似文献   

10.
Four different poly(pyridine) complexes of ruthenium, viz. Ru(II)(trpy)(phen)(OH(2))](2+) (1), trans-[Ru(III)(2,2'bpy)(2)(OH(2))(OH)](2+) (2), [(2,2'bpy)(2)(OH)Ru(III)ORu(III)(OH)(2,2'bpy)(2)](4+) (3), and [Ru(II)(4,4'bpy)(NH(3))(5)](2+) (4) (2,2'bpy=2,2'-bipyridine, 4,4'bpy=4,4'-bipyridine, trpy=2,2',2"-terpyridine, phen=1,10-phenanthroline), were tested as non-physiological charge mediators of 'second-generation' glucose biosensors. The membranes for these biosensors were prepared by casting anionic carboxymethylated beta-cyclodextrin polymer films (beta-CDPA) directly onto the Pt or glassy carbon (GC) disk electrodes. Simultaneously, glucose oxidase (GOD) was immobilized in the films by covalent bonding and the Ru complexes were incorporated both by inclusion in the beta-CD molecular cavities and by ion exchange at the fixed carboxymethyl cation-exchange sites. The leakage of the mediator from the polymer has been minimized by adopting a suitable pre-treatment procedure. The biosensors catalytic activities increased in the order 1<2<3<4, as established by linear sweep voltammetry. In case of complexes 2-4, the enzymatic glucose oxidation was mediated by the Ru complexes at their redox potentials. However, this oxidation was mediated by oxygen in case of complex 1 where H(2)O(2) was detected as the reaction product. The effectiveness of the mediators used in the presence of oxygen has been estimated using Pt and GC supports. The redox potential of the mediator does not depend on the support used, while the oxidation of H(2)O(2) proceeds on GC at much higher positive potentials than on Pt. The sensitivity and the linear concentration range of the biosensor studied varied significantly. For complex 4, which forms stable inclusion complex with beta-CD, the biosensor sensitivity was the highest and equal to 7.2 micro A mM(-1) cm(-2), detectability was as low as 1 mM, but the linear concentration range was limited only to 4 mM. In contrast, for complexes 2 and 3 the sensitivity was 0.4 and 3.2 micro A mM(-1) cm(-2), while the linear concentration range extended up to at least 24 and 14 mM glucose, respectively. Even though some common interfering substances, such as ascorbate, paracetamol or urea, are oxidized at potentials close to those of the Ru complex redox couples, their electro-oxidation currents at physiological concentrations are insignificant compared to those due to the biocatalytic oxidation of glucose. The biosensor response to glucose is reversible as demonstrated by the inhibition of GOD activity by Cu(II). That is, the Cu(II) concentration required to inhibit by half the response to glucose of the biosensor containing complex 2 was 1.0 mM. This inhibitory effect was fully reversed by addition of citrate, a ligand forming sufficiently stable complex with Cu(II).  相似文献   

11.
Layer-by-layer (LBL) assembly of alternate osmium redox polymers and glucose oxidase, at anode, and laccase, at cathode, using graphite electrodes form a membrane-less glucose/O(2) enzymatic fuel cell providing a power density of 103 μW cm(-2) at pH 5.5.  相似文献   

12.
利用三明治电池和伏安法测试了不同制备条件的Nafion基氧化还原聚合物膜在空气中的电荷传输性能. 研究结果表明, 混合适量聚乙二醇(PEG)的Nafion基金属联吡啶配合物{Nafion[M(bpy)2+3, PEG](M=Ru, Fe)}膜的表观电荷传递扩散系数(Dct)达到10-6-10-7 cm2·s-1 , 电子或空穴迁移率(μ)达到10-4-10-5 cm2·V-1·s-1. 在导电玻璃(ITO)电极与Nafion基氧化还原聚合物膜界面引入一层导电聚苯胺(PANI)后, 降低了其接触电阻, 使氧化还原聚合物膜的Dct提高至10-5-10-6 cm2·s-1, μ提高至10-3-10-4 cm2·V-1·s-1, 且工作电流提高了近两个数量级. 该固态氧化还原聚合物膜的性能比较稳定, 在空气中放置30天后其Dct和μ降低得很少.  相似文献   

13.
Silicon carbide (SiC) films have been used frequently for high-frequency and powder devices but have seldom been applied as the electrode material. In this paper, we have investigated the electrochemical properties of the nanocrystalline 3C-SiC film in detail. A film with grain sizes of 5 to 20 nm shows a surface roughness of about 30 nm. The resistivity of the film is in the range of 3.5-6.2 kΩ cm. In 0.1 M H(2)SO(4) solution, the film has a double-layer capacitance of 30-35 μF cm(-2) and a potential window of 3.0 V if an absolute current density of 0.1 mA cm(-2) is defined as the threshold. Its electrochemical activity was examined by using redox probes of [Ru(NH(3))(6)](2+/3+) and [Fe(CN)(6)](3-/4-) in aqueous solutions and by using redox probes of quinone and ferrocene in nonaqueous solutions. Diffusion-controlled, quasi-reversible electrode processes were achieved in four cases. The surface chemistry of the nanocrystalline 3C-SiC film was studied by electrochemical grafting with 4-nitrobenzenediazonium salts. The grafting was confirmed by time-of-flight secondary ion mass spectroscopy. All these results confirm that the nanocrystalline 3C-SiC film is promising for use as an electrode material.  相似文献   

14.
Saleh FS  Mao L  Ohsaka T 《The Analyst》2012,137(9):2233-2238
A new type of dehydrogenase-based amperometric glucose biosensor was constructed using glucose dehydrogenase (GDH) which was immobilized on the edge-plane pyrolytic graphite (EPPG) electrode modified with poly(phenosafranin)-functionalized single-walled carbon nanotubes (PPS-SWCNTs). The PPS-SWCNT-modified EPPG electrode was prepared by electropolymerization of phenosafranin on the EPPG electrode which had been previously coated with SWCNTs. The performance of the GDH/PPS-SWCNT/EPPG bioanode was evaluated using cyclic voltammetry and amperometry in the presence of glucose. The GDH/PPS-SWCNT/EPPG electrode possesses promising characteristics as a glucose sensor: a wide linear dynamic range of 50 to 700 μM, low detection limit of 0.3 μM, fast response time (1-2 s), high sensitivity (96.5 μA cm(-2) mM(-1)), and anti-interference and anti-fouling abilities. Moreover, the performance of the GDH/PPS-SWCNT/EPPG bioanode was tested in a glucose/O(2) biofuel cell. The maximum power density delivered by the assembled glucose/O(2) biofuel cell could reach 64.0 μW cm(-2) at a cell voltage of 0.3 V with 40 mM glucose.  相似文献   

15.
The ordered ultrathin films (UTFs) based on CoFe-LDH (layered double hydroxide) nanoplatelets and manganese porphyrin (Mn-TPPS) have been fabricated on ITO substrates via a magnetic-field-assisted (MFA) layer-by-layer (LBL) method and were demonstrated as an electrochemical sensor for glucose. The XRD pattern for the film indicates a long-range stacking order in the normal direction of the substrate. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) images of the MFA LDH/Mn-TPPS UTFs reveal a continuous and uniform surface morphology. Cyclic voltammetry, impedance spectroscopy, and chronoamperometry were used to evaluate the electrochemical performance of the film, and the results show that the MFA-0.5 (0.5 T magnetic field) CoFe-LDH/Mn-TPPS-modified electrode displays the strongest redox current peaks and fastest electron transfer process compared with those of MFA-0 (without magnetic-field) and MFA-0.15 (0.15 T magnetic field). Furthermore, the MFA-0.5 CoFe-LDH/Mn-TPPS exhibits remarkable electrocatalytic activity toward the oxidation of glucose with a linear response range (0.1-15 mM; R(2) = 0.999), low detection limit (0.79 μM) and high sensitivity (66.3 μA mM(-1) cm(-2)). In addition, the glucose sensor prepared by the MFA LBL method also shows good selectivity and reproducibility as well as resistance to poisoning in a chloride ion solution. Therefore, the novel strategy in this work creates new opportunities for the fabrication of nonenzyme sensors with prospective applications in practical detection.  相似文献   

16.
Novel electroanalytical sensing nanobiocomposite materials are reported. These materials are prepared by mixing multiwalled carbon nanotubes (MWNTs), a Nafion cation exchanger, and glucose oxidase (GOD) in appropriate amounts. The MWNTs are cylindrical with a diameter in the range 40-60 nm and with a length of up to several micrometers, and they provide electrical conductivity. Nafion acts as a polymer backbone to give stable and homogeneous cast thin films. Both MWNTs and Nafion provide negative functionalities to bind to positively charged redox enzymes such as glucose oxidase. The resulting biosensing composite material is inexpensive, reliable, and easy to use. The homogeneity of the MWNT-Nafion-GOD nanobiocomposite films was characterized by atomic force microscopy (AFM). Amperometric transducers fabricated with these materials were characterized electrochemically using cyclic voltammetry and amperometry in the presence of hydrogen peroxide and in the presence of glucose. Their linear response to hydrogen peroxide was demonstrated. The glucose biosensor sensitivity was strongly influenced by the glucose oxidase concentration within the nanobiocomposite film. The optimized glucose biosensor (2.5 mg/mL GOD) displayed a sensitivity of 330 nA/mM, a linear range of up to 2 mM, a detection limit of 4 microM, and a response time of <3 s.  相似文献   

17.
An amperometric glucose biosensor is developed that is based on immobilization of glucose oxidase (GOD) in a composite film of poly(o-aminophenol) (POAP) and carbon nanotubes (CNT), which are electrochemically co-polymerized at a gold (Au) electrode. Because of the high surface per volume ratio and excellent electrical conductivity of CNT, the biosensor based on an Au/POAP/CNT/GOD electrode has lower detection limit (0.01 mM), larger maximum response current (0.24 mA cm(-2)) and higher sensitivity (11.4 mA M(-1) cm(-2)) than the values of the biosensor based on an Au/POAP/GOD electrode. Additionally, the biosensor shows fast response time, large response current, and good anti-interferent ability for ascorbic acid, uric acid and acetaminophen. Good reproducibility and stability of the biosensor are also observed.  相似文献   

18.
《Electroanalysis》2006,18(11):1097-1104
Copolymerization of an osmium(II) functionalized pyrrole moiety, osmium‐bis‐N,N'‐(2,2′‐bipyridyl)‐N‐(pyridine‐4‐ylmethyl‐(8‐pyrrole‐1yl–octyl)‐amine)chloride ( I ) with 3‐methylthiophene was carried out. The resulting conducting polymer film exhibited a clear redox couple associated with the Os3+/2+ response and the familiar conducting polymer backbone signature. The effect of film thickness upon the redox properties of the copolymer was investigated in organic electrolyte solutions. Scanning electron micrographs (SEM) along with energy dispersive X‐ray (EDX) spectra of the copolymerized films were undertaken, both after formation and redox cycling in neutral buffer solution. These clearly show that electrolyte is incorporated into the polymer film upon redox cycling through the Os3+/2+ redox system. The Os3+/2+ response associated with the copolymer was seen to be significantly altered in the presence of ascorbic acid both in acidic and neutral pH buffer solutions. This pointed to an electrocatalytic reaction between the ascorbic acid and the Os3+ form of the copolymer. Under acidic conditions the copolymer film exhibited a sensitivity of 1.76 (±0.05) μA/mM with a limit of detection (LOD) of 1.45 μM for ascorbic acid. Under neutral pH conditions the copolymer exhibited a sensitivity of 19.26 (±1.05) μA/mM with a limit of detection (LOD) of 1.28 μM for ascorbic acid.  相似文献   

19.
At present, a highly sensitive hydrogen peroxide (H2O2) sensor is fabricated by ferrocene based naphthaquinone derivatives as 2,3‐Diferrocenyl‐1,4‐naphthoquinone and 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone. These ferrocene based naphthaquinone derivatives are characterized by H‐NMR and C‐NMR. The electrochemical properties of these ferrocene based naphthaquinone are investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) on modified glassy carbon electrode (GCE). The modified electrode with ferrocene based naphthaquinone derivatives exhibits an improved voltammetric response to the H2O2 redox reaction. 2‐bromo‐3‐ferrocenyl‐1,4‐naphthoquinone show excellent non‐enzymatic sensing ability towards H2O2 response with a detection limitation of 2.7 μmol/L a wide detection range from 10 μM to 400 μM in H2O2 detection. The sensor also exhibits short response time (1 s) and good sensitivity of 71.4 μA mM?1 cm?2 and stability. Furthermore, the DPV method exhibited very high sensitivity (18999 μA mM?1 cm?2) and low detection limit (0.66 μM) compared to the CA method. Ferrocene based naphthaquinone derivative based sensors have a lower cost and high stability. Thus, this novel non‐enzyme sensor has potential application in H2O2 detection.  相似文献   

20.
The nitrogen doped carbon (NDCN) have been synthesized by flame synthetic method to prepare ferrocene decorated NDCN. The hydrolysis product (FC-SH) of ferrocene benzyne derivative (FC-SAc) was immobilized onto NDCN modified GCE and used for glucose detection with high sensitivity. Cyclic voltammetric analysis reveal that FC-S-NDCN/GCE exhibit excellent activity for glucose oxidation when compared to FC/GCE. The FC-S-NDCN/GCE with wide linear responses range from 0.001 to 0.01 mM with the regression co-efficient of 0.998. The FC-S-NDCN/GCE show low detection limit (LOD) of 0.08 μM and exhibit sensitivity of 1580 μA mM−1 cm−2. The FC-S-NDCN glucose sensor exhibit wide linear range, high sensitivity and lower detection limit on determination of glucose.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号