首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Nedelcu S  Slater GW 《Electrophoresis》2005,26(21):4003-4015
In the framework of the classical blob theory of end-labeled free-solution electrophoresis of ssDNA, and based on recent experimental data with linear and branched polymeric labels (or drag-tags), the present study puts forward design principles for the optimal type of branching that would give, for a given total number of monomers, the highest effective frictional drag for ssDNA sequencing purposes. The hydrodynamic radii of the linear and branched labels are calculated using standard models like the freely jointed chain model and the Kratky-Porod worm-like chain model. Based on comparisons of the theory with the experimental data, we propose that the design of new branched labels should use either side chains whose length is comparable to the distance between the branching points or two long branches located near the ends of the molecule's backbone.  相似文献   

2.
Won JI  Meagher RJ  Barron AE 《Electrophoresis》2005,26(11):2138-2148
We demonstrate the feasibility of end-labeled free-solution electrophoresis (ELFSE) separation of DNA using genetically engineered protein polymers as drag-tags. Protein polymers are promising candidates for ELFSE drag-tags because their sequences and lengths are controllable not only to generate monodisperse polymers with high frictional drag, but also to meet other drag-tag requirements for high-resolution separations by microchannel electrophoresis. A series of repetitive polypeptides was designed, expressed in Escherichia coli, and purified. By performing an end-on conjugation of the protein polymers to a fluorescently labeled DNA oligomer (22 bases) and analyzing the electrophoretic mobilities of the conjugate molecules by free-solution capillary electrophoresis (CE), effects of the size and charge of the protein polymer drag-tags were investigated. In addition, the electrophoretic behavior of bioconjugates comprising relatively long DNA fragments (108 and 208 bases) and attached to uncharged drag-tags was observed, by conjugating fluorescently labeled polymerase chain reaction (PCR) products to charge-neutral protein polymers, and analyzing via CE. We calculated the amount of friction generated by the various drag-tags, and estimated the potential read-lengths that could be obtained if these drag-tags were used for DNA sequencing in our current system. The results of these studies indicate that larger and uncharged drag-tags will have the best DNA-resolving capability for ELFSE separations, and that theoretically, up to 233 DNA bases could be sequenced using one of the protein polymer drag-tags we produced, which is electrostatically neutral with a chain length of 337 amino acids. We also show that denatured (unfolded) polypeptide chains impose much greater frictional drag per unit molecular weight than folded proteins, such as streptavidin, which has been used as a drag-tag before.  相似文献   

3.
End-labeled free solution electrophoresis (ELFSE) provides a means of separating DNA with free-solution CE, eliminating the need for gels and polymer solutions which increase the run time and can be difficult to load into a capillary. In free-solution electrophoresis, DNA is normally free-draining and all fragments reach the detector at the same time, whereas ELFSE uses an uncharged label molecule attached to each DNA fragment in order to render the electrophoretic mobility size-dependent. With ELFSE, however, the larger molecules are not separated enough (limiting the read length in the case of ssDNA sequencing) while the smaller ones are overseparated; the larger ones are too fast while the shorter ones are too slow, which is the opposite of traditional gel-based methods. In this article, we show how an EOF could be used to overcome these problems and extend the DNA sequencing read length of ELFSE. This counterflow would allow the larger, previously unresolved molecules more time to separate and thereby increase the read length. Through our theoretical investigation, we predict that an EOF mobility of approximately the same magnitude as that of unlabeled DNA would provide the best results for the regime where all molecules move in the same direction. Even better resolution would be possible for smaller values of EOF which allow different directions of migration; however, the migration times then would become too large. The flow would need to be well controlled since the gain in read length decreases as the magnitude of the counterflow increases; an EOF mobility double that of unlabeled DNA would no longer increase the read length, although ELFSE would still benefit from a reduction in migration time.  相似文献   

4.
McCormick LC  Slater GW 《Electrophoresis》2007,28(21):3837-3844
DNA sequencing by electrophoresis can be dramatically sped up by overcoming the need for the sieving medium. Normally it is possible to separate DNA based on size in free solution; however, not end-labeled free-solution electrophoresis (ELFSE) uses a neutral drag-tag molecule to make it possible. In experiments to date, the drag-tag and DNA together form a random coil conformation; while with future generation drag-tags and high fields, deformation of this conformation may occur. In the first paper in this series we investigated the conditions under which the DNA and label become hydrodynamically distinct (or segregated), based on a theoretical approach developed for the electrophoresis of polyampholytes. In this paper we study further deformation wherein either the DNA and/or a polymeric label stretch. We show that deformation may dramatically improve the capabilities of ELFSE, especially when both the DNA and a polymeric drag-tag fully stretch; however, reaching these regimes will require extremely high field intensities, something that only microchip technologies may be able to achieve.  相似文献   

5.
Recently two novel techniques using free-solution electrophoresis to separate charged-uncharged polymer conjugates have proven successful: end-labeled free-solution electrophoresis (ELFSE) for DNA sequencing, and free-solution conjugate electrophoresis (FSCE) for molar mass profiling of uncharged polymers. The approach taken to analyze the experimental data was an extension of the theory of Long and co-workers (Long, D., Dobrynin, A. V., Rubinstein, M., Ajdari, A., J. Chem. Phys. 1998, 108, 1234-1244) for the electrophoresis of molecules with varying charge distributions. This theory also predicts that the ends of the polymers play a large role in determining the polymer's overall mobility; however, this aspect of the theory was neglected in previous work. Until now this "end effect" has, to the knowledge of the authors, not been recognized in experimental data. Through a careful investigation of the predicted end effect and a reanalysis of the experimental data, we demonstrate that indeed this effect critically impacts on the behavior of charged-uncharged polymer conjugates during electrophoresis. This work indicates that not only does the end effect need to be taken into account to avoid significant errors in data analysis, but also it provides novel system optimization approaches.  相似文献   

6.
End-labeled free-solution electrophoresis (ELFSE) is an alternative approach to gel-based methods for size-based electrophoretic separation of DNA. In ELFSE, an electrically neutral "drag-tag" is appended to DNA to add significant hydrodynamic drag, thereby breaking its constant charge-to-friction ratio. Current drag-tag architecture relies on covalent attachment of polymers to each DNA molecule. We have recently proposed the use of micellar drag-tags in conjunction with sequence-specific hybridization of peptide nucleic acid amphiphiles (PNAAs). This work investigates the effect of multiple PNAA attachment on DNA resolution using MEKC. Simultaneous PNAA hybridization allows for the separation of long DNA targets, up to 1012 bases, using micellar drag-tags. Each PNAA handle independently interacts with the micellar phase, reducing the overall mobility of this complex relative to individual PNAA binding. The sequence- and size-based dependence of this separation technique is maintained with multiple PNAA binding over a range of DNA sizes. Results are accurately described by ELFSE theory, yielding alpha=54 for single-micelle tagging and alpha=142 for dual-micelle tagging. This method is the first example of a non-covalent drag-tag used to separate DNA of 1000 bases based on both size and sequence.  相似文献   

7.
We assessed the feasibility of high-speed DNA sequencing by tube-based capillary electrophoresis (TCE) with electrokinetic sample injections. We developed a water-circulated TCE system to control the capillary temperature precisely. Using this system and a ready-made sieving matrix at 50 degrees C, single-stranded DNA size marker fragments were separated at various pairs of the electric field strength, E, of 128-480 V/cm and the capillary effective length, L, of 100-360 mm. Assuming the read length (RL) is the fragment size at which the peak width equals the peak interval per base in obtained electropherograms, we estimated the values of RL (E, L), the RL at the pair (E, L). The points in ELz-space, (E, L, RL(E, L)), form a curved surface expressed by z = RL(E, L). Analyzing the contour lines of this curved surface, we determined the pairs of E and L providing target RLs of 300-500 bases within a minimum time. At a pair optimized for a 500-base RL (330 V/cm, 200 mm), one-color sequencing fragments were successfully separated up to 529 bases within 9.6 min. These results demonstrate that high-speed DNA sequencing comparable with that obtained by microfabricated chip-based capillary electrophoresis (MCE) can be achieved with TCE, which is more suitable in automation than MCE.  相似文献   

8.
We present a nonlinear optimization study of different implementations of the DNA electrophoretic method “End‐labeled Free‐solution Electrophoresis” in commercial capillary electrophoresis systems and microfluidics to improve the time required for readout. Here, the effect of electro‐osmotic counterflows and snap‐shot detection are considered to allow for detection of peaks soon after they are electorphoretically resolved. Using drag tags available in micelle form, we identify a design capable of sequencing 600 bases in 2.8 min.  相似文献   

9.
A numerical model is presented for the accurate and efficient prediction of preconcentration and transport of DNA during sample introduction and injection in microcapillary electrophoresis. The model incorporates conservation laws for the different buffer ions, salt ions, and DNA sample, coupled through a Gaussian electric field to account for the field modifications that cause electromigration. The accuracy and efficiency required to capture the physics associated with such a complex transient problem are realized by the use of the finite element-flux corrected transport (FE-FCT) algorithm in two dimensions. The model has been employed for the prediction of DNA sample preconcentration and transport during electrophoresis in a double-T injector microdevice. To test its validity, the numerical results have been compared with the corresponding experimental data under similar conditions, and excellent agreement has been found. Finally, detailed results from a simulation of DNA sample preconcentration in electrophoretic microdevices are presented using as parameters the electric field strength and the other species concentrations. The effect of the Tris concentration on sample stacking is also investigated. These results demonstrate the great potential offered by the model for future optimization of such microchip devices with respect to significantly enhanced speed and resolution of sample separation.  相似文献   

10.
Ventzki R  Stegemann J 《Electrophoresis》2003,24(24):4153-4160
We report a novel separation method that is applicable to both DNA and protein samples, based on electrophoresis in a three-dimensional (3-D) geometry. In contrast to conventional electrophoresis, samples are applied in a two-dimensional, planar array to one of the surfaces of a 3-D geometry separation medium. Loading onto a plane results in a very high sample capacity. Sample migration and separation occur along the third spatial dimension, which is perpendicular to the loading plane. The key problem of electrophoresis in a 3-D geometry separation setup is that temperature gradients are caused by Joule's heat, affecting the electrical conductivity and viscosity of the separation medium. A means of achieving straight sample migration under these circumstances is to force heat flow through the separation medium parallel to the axis of sample migration. This can be done by dissipating the heat via the electrode sides of the gel and blocking any other heat transfer. The separation of DNA and proteins by this method has been tested using agarose gel electrophoresis, polyacrylamide gel electrophoresis, and sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Data were acquired off-line by conventional staining methods as well as on-line by detection of laser-induced fluorescence. We describe how to excise samples from the separation medium for preparative purposes. Possible unique applications of this 3-D geometry electrophoresis separation method are also discussed.  相似文献   

11.
An aptamer-based label-free approach to hemin recognition and DNA assay using capillary electrophoresis with chemiluminescence detection is introduced here. Two guanine-rich DNA aptamers were used as the recognition element and target DNA, respectively. In the presence of potassium ions, the two aptamers folded into the G-quartet structures, binding hemin with high specificity and affinity. Based on the G-quartet–hemin interactions, the ligand molecule was specifically recognized with a K d ≈ 73 nM, and the target DNA could be detected at 0.1 μM. In phosphate buffer of pH 11.0, hemin catalyzed the H2O2-mediated oxidation of luminol to generate strong chemiluminescence signal; thus the target molecule itself served as an indicator for the molecule–aptamer interaction, which made the labeling and/or modification of aptamers or target molecules unnecessary. This label-free method for molecular recognition and DNA detection is therefore simple, easy, and effective. Figure A label-free approach to aptamer-based hemin recognition and DNA detection is introduced, which gives great potential for using a small molecule itself as the indicator for molecular recognition and DNA detection thereby avoiding any labeling or modification step  相似文献   

12.
We demonstrate here the power and flexibility of free‐solution conjugate electrophoresis (FSCE) as a method of separating DNA fragments by electrophoresis with no sieving polymer network. Previous work introduced the coupling of FSCE with ligase detection reaction (LDR) to detect point mutations, even at low abundance compared to the wild‐type DNA. Here, four large drag‐tags are used to achieve free‐solution electrophoretic separation of 19 LDR products ranging in size from 42 to 66 nt that correspond to mutations in the K‐ras oncogene. LDR‐FSCE enabled electrophoretic resolution of these 19 LDR‐FSCE products by CE in 13.5 min (E = 310 V/cm) and by microchip electrophoresis in 140 s (E = 350 V/cm). The power of FSCE is demonstrated in the unique characteristic of free‐solution separations where the separation resolution is constant no matter the electric field strength. By microchip electrophoresis, the electric field was increased to the maximum of the power supply (E = 700 V/cm), and the 19 LDR‐FSCE products were separated in less than 70 s with almost identical resolution to the separation at E = 350 V/cm. These results will aid the goal of screening K‐ras mutations on integrated “sample‐in/answer‐out” devices with amplification, LDR, and detection all on one platform.  相似文献   

13.
One rapid CE method was established to diagnose Duchenne muscular dystrophy (DMD). DMD is a severe recessive inherited disorder frequently caused by gene deletions. Among them, exons 1–20 account for nearly 30% of occurrences. In this study, the universal multiplex PCR was used to enhance the fluorescently labeling efficiency, which was performed only by one universal fluorescent primer. After PCR, a short‐end injection CE (short‐end CE) speeded up the genotyping of the DMD gene. This method involved no extra purification, and was completed within 9 min. The CE conditions contained a polymer solution of 1.5% hydroxylethylcellulose in 1× TBE buffer at 6 kV for separation. This method was applied to test six DMD patients and one healthy male person. The results showed good agreement with those of multiplex ligation‐dependent probe amplification. This method can be applied for clinical diagnosis of DMD disease. Accurate diagnosis of the DMD gene is the best way to prevent the disease.  相似文献   

14.
The formation of secondary structure in oligonucleotide DNA is known to lead to "compression" artifacts in electropherograms produced through DNA sequencing. Separately, the formation of secondary structure in mRNA is known to suppress translation; in particular, when such structures form in a region covered by the ribosome either during, or shortly after, initiation of translation. Here, we demonstrate how a DNA sequencing compression artifact provides important clues to the location(s) of translation-suppressing secondary structural elements in mRNA. Our study involves an engineered version of a gene sourced from Rhodothermus marinus encoding an enzyme called Cel12A. We introduced this gene into Escherichia coli with the intention of overexpressing it, but found that it expressed extremely poorly. Intriguingly, the gene displayed a remarkable compression artifact during DNA sequencing electrophoresis. Selected "designer" silent mutations destroyed the artifact. They also simultaneously greatly enhanced the expression of the cel12A gene, presumably by destroying stable mRNA structures that otherwise suppress translation. We propose that this method of finding problem mRNA sequences is superior to software-based analyses, especially if combined with low-temperature CE.  相似文献   

15.
Wang Y  Liang D  Ying Q  Chu B 《Electrophoresis》2005,26(1):126-136
Quasi-interpenetrating network (IPN) formed by polyacrylamide and poly(N,N-dimethylacrylamide) was designed, synthesized, and tested as a high-performance DNA separation medium by capillary electrophoresis. The performance of quasi-IPN on DNA sequencing was determined by the acrylamide to dimethylacrylamide molar ratio, polyacrylamide molecular weight, and its size distribution. Under optimal operating conditions, quasi-IPN was able to achieve one-color DNA sequencing up to 1000 bases in 39 min, or 1200 bases in 60 min. Its performance was compared with some of the existing commercialized products, such as POP6 from Applied Biosystems and MegaBACE matrix from Amersham Biosciences. By using the ABI 310 Genetic Analyzer, even without optimized base-calling software, quasi-IPN yielded a read length of up to 700 bases of contiguous sequence (50-750 bases) in 35 min with 99.6% accuracy, or 750 bases of contiguous sequence (50-800 bases) in 37 min with 98.0% accuracy.  相似文献   

16.
A discontinuous Tris-Cl/acetate (OAc) buffer system, unprecedently containing OAc as the trailing constituent, and operative in polyacrylamide gel electrophoresis (PAGE) at low polyacrylamide concentration (T = 4.8%) is described in the paper. The characteristics of the electrophoretic system are illustrated by the resolution of fluorescent 8-aminonaphthalene-1,3,6-trisulfonic acid (ANTS)-labeled malto-oligosaccharides and dextran homopolymers. In this buffer system, the resolving phase is constituted by Tris-OAc behind a moving boundary formed between the leading chloride ion of Tris-HCl gel buffer and the trailing OAc ion provided by a catholyte of NH(4)OAc. In contrast with the results obtained with Tris-CI/glycinate buffer commonly used in electrophoresis, or with Tris-CI/borate, the best resolution of the glucose oligomers containing 1-4 glucose units in Tris-OAc, pH 8.8, ionic strength of 0.08, was obtained at 4.8% polyacrylamide concentration, using 0.5 M NH(4)OAc, pH 9.5 as the catholyte. Under those conditions, the ANTS-glucose oligomers were separated with mobilities decreasing from glucose to maltohexaose. The linear Ferguson plots (log relative mobility, R(f), vs.%T) of the glucose oligomers show that the surface net charge of those oligomers is inversely related to their sizes, given by the slopes, K(R), of the plots. The molecular weight of the oligomers is directly but nonlinearly related to K(R). The novel electrophoretic system illustrated here for separation of short ANTS-saccharides can be potentially applied to the resolution of other biomolecules such as rapidly migrating DNA, peptides or proteins.  相似文献   

17.
Lo RC  Ugaz VM 《Electrophoresis》2006,27(2):373-386
Considerable effort has been directed toward optimizing performance and maximizing throughput in ssDNA electrophoresis because it is a critical analytical step in a variety of genomic assays. Ultimately, it would be desirable to quantitatively determine the achievable level of separation resolution directly from measurements of fundamental physical properties associated with the gel matrix rather than by the trial and error process often employed. Unfortunately, this predictive capability is currently lacking, due in large part to the need for a more detailed understanding of the fundamental parameters governing separation performance (mobility, diffusion, and dispersion). We seek to address this issue by systematically characterizing electrophoretic mobility, diffusion, and dispersion behavior of ssDNA fragments in the 70-1,000 base range in a photopolymerized cross-linked polyacrylamide matrix using a slab gel DNA sequencer. Data are collected for gel concentrations of 6, 9, and 12%T at electric fields ranging from 15 to 40 V/cm, and resolution predictions are compared with corresponding experimentally measured values. The data exhibit a transition from behavior consistent with the Ogston model for small fragments to behavior in agreement with the biased reptation model at larger fragment sizes. Mobility data are also used to estimate the mean gel pore size and compare the predictions of several models.  相似文献   

18.
Analyses of germline and somatic single-nucleotide DNA variations are important in both population genetics research and clinical practice. Reliable and inexpensive methods that are flexible and designed for automation are required for these analyses. Present day DNA sequencing technology is too expensive for testing all 22-25 000 human genes in populations genetics studies or in scanning large numbers of tumors for novel mutations. Denaturant capillary electrophoresis (DCE) has the potential to meet the need for large-scale analysis of DNA variants. Several different analyses can be performed by DCE, including mutation analysis, single-nucleotide polymorphism (SNP) discovery in individual and pooled samples, detection of allelic imbalance, and determination of microhaplotypes. Here we review the theoretical background of the method, its sensitivity, specificity, detection limit, throughput, and repeatability in the light of current literature in the field.  相似文献   

19.
DNA molecules of Vibrio cholerae and Aeromonas species were prepared by incubating immobilized cells for 4 and 2 h, respectively, with a nonenzymatic solution that contains chemical reagents only (NDSUPlus). This method gave results as reproducible as the enzymatic one that uses proteinase K, and rendered DNA molecules suitable for fingerprinting by mini-CHEF electrophoresis. As rapid DNA separations at high electric field are achieved in mini-CHEF chamber with low heat evolution, DNA restriction fragments were separated in 5 h at 10 V/cm in a single resolution window. Then, fragment separations in three resolution windows were done in 15 h. This time is shorter than the one needed by the large CHEF chamber for resolving fragments in a single resolution window. Three windows permitted to include larger numbers of restriction fragments in the calculation of isolate similarities. Both sample preparation and mini-CHEF electrophoresis may represent an alternative for performing massive epidemiological studies of V. cholerae and Aeromonas species.  相似文献   

20.
Xu Y  Qin W  Li SF 《Electrophoresis》2005,26(3):517-523
A portable capillary electrophoresis (CE) system with a novel potential gradient detection (PGD) was utilized to separate DNA fragments. For the first time it was demonstrated that separation of DNA fragments in polymer solution could be detected by a portable CE system integrated with PGD, with a limit of detection (LOD) comparable to that of the CE-ultraviolet (UV) method. Effects of buffer solution, sieving medium, and applied voltage were also investigated. The portable CE-PGD system shows several potential advantages, such as simplicity, cost effectiveness, and miniaturization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号