Directly coupled LC-MS and LC-NMR were applied to identify and structurally characterize an acarbose degradation product A in acidic media. A comparative analysis of the stop-flow LC-NMR (1H and TOCSY) and LC-MS data provided evidence that A is structurally related to acarbose, differing from the parent compound in a number of subunits present in the molecule. Spectral analysis revealed that A was the alpha-glucosidase inhibitor amylostatin XG. Complementary information obtained from the two methods led to the structural elucidation of A which was later corroborated by high-resolution NMR spectroscopy of the isolated molecule.  相似文献   

2.
Rapid and unambiguous identification of three degradation products (DP-1, DP-2 and DP-3) found in heat-stressed loxoprofen sodium adhesive tapes (Loxonin tapes) was achieved by LC-MS and dynamic pressurized liquid extraction (PLE)-solid-phase extraction (SPE) coupled to LC-NMR without complicated isolation or purification processes. The molecular formulae of the degradation products were determined by accurate mass measurements and product ion analyses and on-line hydrogen/deuterium (H/D) exchange experiments provided information about changes in the degradation of loxoprofen. To compensate for the low sensitivity of NMR, on-line dynamic PLE-SPE was employed and higher concentrations of degradation products trapped on the SPE column were afforded in a shorter time than they would be in such time-consuming sample preparations as pre-concentration after extraction. The loop-storage procedure was used in the LC-NMR analysis to allow the acquisition of the (1)H spectra of the three degradation products in one chromatographic run without affecting the peak separation and to avoid the carry-over of previously eluted DP-1 of high concentration by washing the NMR detection cell prior to the measurement of the DP-2 spectrum. Based on the resulting (1)H NMR spectra in combination with the MS results, DP-1 was successfully identified as an oxidation product having an oxodicarboxylic acid structure formed by the cleavage of the cyclopentanone ring of loxoprofen, DP-2 as a cyclopentanone ring-hydroxylated loxoprofen and DP-3 as a loxoprofen l-menthol ester.  相似文献   

3.
The usefulness of applying an integrated LC-NMR and LC-MS approach to acarbose bulk drug impurity profiling is demonstrated. LC-MS and LC-NMR methodologies were employed for the online separation and structural elucidation of a final drug product. Combining data provided by the stop-flow LC-NMR and LC-MS experiments made it possible to identify the main components present in the acarbose sample. Spectral analysis revealed that A and B were known impurities while C was an unknown compound. LC-MS and LC-NMR analyses revealed that C was a pentasaccharide differing from the acarbose in number and nature of sugar subunits in the molecule. It was subsequently isolated and its structure was confirmed by the offline 1- and 2-D NMR experiments, and atom assignment was made.  相似文献   

4.
The present study dealt with the forced degradation behaviour of rosuvastatin under ICH prescribed stress conditions. The drug was found to be labile under acid hydrolytic and photolytic conditions, while it was stable to base/neutral hydrolytic, oxidative and thermal stress. In total, 11 degradation products were formed, which were separated on a C-18 column using a stability-indicating method. LC-MS analyses indicated that five degradation products had the same molecular mass as that of the drug, while the remaining six had 18 Da less than the drug. Structure elucidation of all the degradation products was executed using sophisticated and modern structural characterization tools, viz. LC-MS/TOF, LC-MSn, on-line H/D exchange and LC-NMR. The degradation pathway and mechanisms of degradation of the drug were delineated. Additionally, in silico toxicity was predicted for all the degradation products using TOPKAT and DEREK software and compared with the drug. This study demonstrates a comprehensive approach of degradation studies during the drug development phase.
Figure
Degradation pathway of rosuvastatin  相似文献   

5.
We find polymers everywhere in our daily activities, for example, as a part of consumer electronics products, healthcare devices, vehicles, etc. Analytical characterization of such materials is an important step towards understanding their properties and behavior in various applications. The increase of material complexity driven by highly demanding requirements for many applications necessitates the use of sophisticated analytical techniques to obtain sufficient insight into the structure of these materials. Coupling of liquid chromatography with other information-rich instrumental techniques becomes more and more important in the field of polymer characterization. Such combination can enable simultaneous separation, identification, and quantification of polymer sample components. In addition, it can provide information on interdependence of two polymer properties, e.g., molecular weight and chemical composition. Different hyphenated systems may be applied to address different problems in polymer research and development and a selection of the right technique may not be an easy and straightforward task. In this paper, the applications of LC-NMR, LC-IR, LC-Raman, LC-MS, LC-MALDI, LC × LC, and LC × Py-GC for polymer analysis are reviewed, their advantages and limitations are discussed, and practical challenges for the implementation of these techniques in a lab are addressed. Different hyphenated options are compared to facilitate selection of a suitable instrument for the particular problem at hand.  相似文献   

6.
Five groundwater samples from the former ammunition production site at Elsnig, Germany, were analyzed for highly polar components by LC-NMR and LC-MS. A variety of unknown pollutants could be identified. Possibilities and limitations of the combined use of LC-NMR and LC-MS techniques for on-line identification are discussed. Further unknown components were identified through isolation by HPLC cuts and off-line NMR and MS investigations. Most of the polar compounds in the investigated samples could also be quantified.  相似文献   

7.
For rapid screening of natural products from Actinomycetes, a combination of on-line couplings LC-NMR, LC-DAD-MS and HPLC-PDA, as well as MALDI-TOF-MS is particularly suitable. Simultaneous use of these coupling techniques provides considerable advantages for the rapid identification of natural compounds in mixtures.The results of our present investigation on secondary metabolite products of Streptomyces violaceoruber TU 22 showed that more than 50% of the identified metabolites are new compounds. The structures of four new polyketides (granaticin C, metenaticin A, B and C) as well as four known ones (granaticin A, granatomycin E, daidzein and genistein) have been elucidated using LC-NMR, LC-MS/MS and -MS(n) techniques in combination with two-dimensional NMR spectroscopy.  相似文献   

8.
The use of hyphenated LC-NMR and LC-MS techniques for the purpose of directly identifying the major constituents of Belamcanda chinensis was investigated. Reversed-phase isocratic chromatography was performed using an acetonitrile-water solvent system on a C18 column. The NMR spectrum yielded five main peaks, whose analysis revealed them to be 5, 6, 7, 3'-tetrahydroxy-4'-methoxyisoflavone (1), tectorigenin (2), iristectorigenin A (3), irigenin (4), and irisflorentine (5). The identification of these constituents was confirmed by performing LC-ESI-MS experiment. This study shows that hyphenated LC-NMR and LC-MS can be used for the rapid (70 min) identification of the isoflavonoids.  相似文献   

9.
Previous studies revealed that the main isoflavones in extracts of leaves of T. pratense L. are biochanin A and formononetin, their 7-O-glucosides, and two glucoside malonate isomers of each of them. Since LC-MS(/MS) did not provide sufficient information to distinguish the glucoside malonate isomers, in the present paper LC-NMR as well as off-line two-dimensional NMR were used to obtain further structural information. Matrix solid-phase dispersion (MSPD) was applied to obtain sufficiently high analyte concentrations to perform LC-NMR. Stop-flow reversed-phase LC-NMR was performed using a gradient of deuterated water and deuterated acetonitrile. Offline COSY and NOESY experiments were carried out to determine the positions of the glucose moiety on the flavonoid aglycone, and of the malonate moiety on the glucose. Based on the fragmentation patterns in MS/MS and the NMR spectra, the two formononetin glucoside malonate isomers were identified as 7-O-beta-D-glucoside 6"-O-malonate and 7-O-beta-D-glucoside 4"-O-malonate; i.e. they only differ in the substitution position of the malonate group on the glucoside ring. The biochanin A glucoside malonate isomers, however, have quite different structures. The main and later eluting isomer is biochanin A 7-O-beta-D-glucoside 6"-O-malonate, and the minor and earlier eluting isomer is 5-hydroxy-7-methoxyisoflavone 4'-O-beta-D-glucoside 4"-O-malonate: the positions of the methoxy group and the glucoside 6"-O-malonate group on the flavonoid skeleton are interchanged.  相似文献   

10.
Two commercial liquid chromatography-Fourier-transform infrared spectroscopy interfaces (LC-FTIR), viz. a flow cell and a solvent-elimination interface have been assessed for use in size-exclusion chromatography (SEC) with respect to their chromatographic integrity (i.e. peak asymmetry, chromatographic resolution), quantitative and qualitative aspects. A polycarbonate/aliphatic polyester (PC/APE) blend and a polycarbonate-co-polydimethylsiloxane (PC-co-PDMS) copolymer were selected for the assessment. Both samples were successfully and selectively analyzed. The relatively large volume of the flow cell and the inherent deposition characteristics of the solvent-elimination interface led to a comparable decrease in the chromatographic resolution. The separation of oligomers was diminished in comparison with SEC-ultra-violet (UV). However, the peak asymmetry was not significantly affected by either interface. For both interfaces, a linear relationship was obtained for the FTIR response versus the injected concentration. The sensitivity was found to be higher for the solvent-elimination interface. For the current model compounds, the flow-cell interface detection limits are worse. However, the repeatability of flow-cell SEC-FTIR, evaluated by means of four SEC-FTIR analyses of polycarbonate, was considerably better than for solvent-elimination SEC-FTIR. This is probably due to the well-defined optical path length of the sample in the flow cell. By spectral subtraction, it was very well possible to obtain qualitative (functional group) information for compound identification also with flow-cell SEC-FTIR.  相似文献   

11.
Plants represent an extraordinary reservoir of novel molecules and there is currently a resurgence of interest in the vegetable kingdom as a possible source of new lead compounds for introduction into therapeutical screening programs. In order to discover potential new bioactive natural products, the dereplication of crude plant extracts performed prior to isolation work is of crucial importance for avoiding the isolation of a known constituent. In this respect, chemical screening strategies have been developed using hyphenated techniques (LC/UV-DAD, LC-MS and LC-NMR). In our laboratory, these techniques have been fully integrated into the isolation process and are used for the chemical screening of crude plant extracts in complement with on-line or at-line bioassays. LC-UV-MS is used as a first dereplication step in combination with UV and MS databases, while LC-NMR is performed in a second step for de novo on-line structure determination. This approach enables the partial or the complete on-line identification of natural products in complex matrices such as crude plant extracts. These methods also give a unique possibility to study unstable compounds, which rapidly degrade or which are not separable at a preparative level.In the multi-hyphenated approach used (hypernation), LC-NMR plays a key role since it provides the most detailed structural information. The relatively low sensitivity of this technique, however, requires that strategies for high loading of plant extracts are developed and compromises for solvent selection have to be made. For more demanding experiments, at-line strategies based on the microfractionation of the LC-peak of interest and recording of spectra in fully deuterated solvents in microflow probes represent a promising alternative.  相似文献   

12.
Liquid chromatography with photodiode array detection (LC-DAD) and liquid chromatography with mass spectrometry (LC-MS) are two techniques that have been widely used in monitoring pesticides and their degradation products in the environment. However, the application of liquid chromatography with tandem mass spectrometry (LC-MS-MS) for such purposes, once considered too costly, is now gaining considerable ground. In this study, we compare these methods for the multi-residue analysis of pesticides in surface waters collected from the central and southeastern regions of France, and from the St. Lawrence River in Canada. Forty-eight pesticides belonging to eight different classes (triazine, amide, phenylurea, triazole, triazinone, benzimidazole, morpholine, phenoxyalkanoic), along with some of their degradation products, were monitored on a regular basis in the surface waters. For LC-MS, we used the electrospray ionization (ESI) interface in the negative ionization mode on acidic pesticides (phenoxyalkanoic, sulfonylurea), and the atmospheric pressure chemical ionization (APCI) interface in the positive ionization mode on the remaining chemicals. Different extraction techniques were employed, including liquid-liquid extraction with dichloromethane, and solid-phase extraction using C18-bonded silica and graphitized carbon black cartridges. Eleven of the target chemicals (desethylatrazine, desisopropylatrazine, atrazine, simazine, terbuthylazine, metolachlor, carbendazime, bentazone, penconazole, diuron and isoproturon) were detected by LC-MS at concentrations ranging from 20 to 900 ng/l in the surface waters from France, and six pesticides (atrazine, desethylatrazine, desisopropylatrazine, cyanazine, simazine and metolachlor) were detected by LC-MS and LC-MS-MS at concentrations ranging from 3 to 52 ng/l in the samples drawn from the St. Lawrence River. There was good correlation between the LC-DAD and LC-MS techniques for 60 samples. The slope of the curves expressing the relationship between the results obtained with LC-DAD versus those obtained by LC-MS was near 1, with a correlation coefficient (r) of over 0.93. The identification potential of the LC-MS technique, however, was greater than that of the LC-DAD; its mass spectra, mainly reflecting the pseudomolecular ion resulting from a protonation or a deprotonation of the molecule, was rich in information. The LC-MS-MS technique with ion trap detectors, tested against the LC-MS on 10 surface water samples, gave results that correlated well with the LC-MS results, albeit generating mass spectra that yielded far more information about the structure of unknown substances. The sensitivity of the LC-MS-MS was equivalent to the selected ion monitoring (SIM) acquisition mode in LC-MS. The detection limits of the target pesticides ranged from 20 to 100 ng/l for the LC-MS technique (under full scan acquisition), and from 2 to 6 ng/l for LC-MS-MS. These limits were improved by a factor of almost 10 by increasing the sample volume to 10 l.  相似文献   

13.
The present study deals with the forced degradation behavior of dexlansoprazole under International Conference on Harmonisation (ICH) prescribed stress conditions. The drug was found to be more labile under acid, base, neutral, oxidative hydrolysis and thermal stress, while it was moderately stable under photolytic conditions. The known and unknown degradation products were separated on a C-18 column using a stability-indicating method. Liquid chromatography-mass spectrometry (LC-MS) analysis was performed for all the degradation studies. Isolation and structure characterization of oxidation degradation products were executed using sophisticated tools, viz. preparative high performance liquid chromatography (HPLC), liquid chromatography-mass spectrometry/time of flight (LC-MS/TOF), liquid chromatography-tandem mass spectrometry (LC-MS/MS), and nuclear magnetic resonance (NMR). This study demonstrates an ample methodology of degradation studies and structure elucidation of unknown degradation products of dexlansoprazole, which helps in the development and stability study of active pharmaceutical ingredients and formulated products.  相似文献   

14.
An overview of recent advances in nuclear magnetic resonance (NMR) coupled with separation technologies and their application in natural product analysis is given and discussed. The different modes of LC-NMR operation are described, as well as how technical improvements assist in establishing LC-NMR as an important tool in the analysis of plant-derived compounds. On-flow, stopped-flow and loop-storage procedures are mentioned, together with the new LC-SPE-NMR configuration. The implementation of mass spectrometry in LC-NMR is also useful on account of the molecular weight and fragmentation information that it provides, especially when new plant species are studied. Cryogenic technology and capillary LC-NMR are the other important recent developments. Since the plant kingdom is endless in producing potential drug candidates, development and optimization of LC-NMR techniques convert the study of natural products to a less-time-consuming task, speeding up identification.  相似文献   

15.
《色谱》2016,(3)
The present study deals with the forced degradation behavior of dexlansoprazole under International Conference on Harmonisation(ICH)prescribed stress conditions. The drug was found to be more labile under acid,base,neutral,oxidative hydrolysis and thermal stress,while it was moderately stable under photolytic conditions. The known and unknown degradation products were separated on a C-18 column using a stabilityindicating method. Liquid chromatography-mass spectrometry(LC-MS)analysis was performed for all the degradation studies. Isolation and structure characterization of oxidation degradation products were executed using sophisticated tools,viz. preparative high performance liquid chromatography(HPLC),liquid chromatographymass spectrometry / time of flight(LC-MS / TOF),liquid chromatography-tandem mass spectrometry(LC-MS /MS),and nuclear magnetic resonance(NMR). This study demonstrates an ample methodology of degradation studies and structure elucidation of unknown degradation products of dexlansoprazole,which helps in the development and stability study of active pharmaceutical ingredients and formulated products.  相似文献   

16.
A main degradation product of Irgarol [2-(methylthio)-4-(tert-butylamino)-6-(cyclopropylamino)-s-triazine], one of the most widely used compounds in antifouling paints, was detected at trace levels in seawater and sediment samples collected from several marinas on the Mediterranean coast. This degradation product was identified as 2-methylthio-4-tert-butylamino-s-triazine. The unequivocal identification of this compound in seawater samples was carried out by solid-phase extraction (SPE) coupled on-line with liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS). SPE was carried out by passing 150 ml of seawater sample through a cartridge containing a polymeric phase (PLRP-s), with recoveries ranging from 92 to 108% (n=5). Using LC-MS detection in positive ion mode, useful structural information was obtained by increasing the fragmentor voltage, thus permitting the unequivocal identification of this compound in natural samples. Method detection limits were in the range of 0.002 to 0.005 microg/l. Overall, the combination of on-line SPE and LC-APCI-MS represents an important advance in environmental analysis of herbicide degradation products in seawater, since it demonstrates that trace amounts of new polar metabolites may be determined rapidly. This paper reports the LC-MS identification of the main degradation product of Irgarol in seawater and sediment samples.  相似文献   

17.
A variety of structural analogues of streptolydigin exists in the cultural supernatants of Streptomyces lydicus AS 4.2501. The degradation of streptolydigin in cultural supernatants with different pH values kept at 25°C in a thermostatic bath was investigated using LC-MS/MS detection. Analysis of the alkaline supernatants (pH 9.50) provides evidence of degradation and conversion between streptolydigin and its structural analogues. Interestingly, a new streptolydigin analogue was detected by LC-MS and photo-diode array (PDA) detection in the process of alkaline degradation. After 48 h in a thermostatic bath, the degradation of streptolydigin and its two analogues at pH 9.50 approached pseudo-first order kinetics. Comparatively, the degradation of streptolydigin was much more rapid in the cultural supernatants with pH 3.05, only requiring 2 hours. Qualitative analysis of the degradation products by LC-MS/MS and PDA indicated that hydrolysis of the epoxy ether bond and acid amide bond was the major mechanism of degradation in acidic cultural supernatants. Two degradation products in the acid supernatant were assumed.  相似文献   

18.
A rapid, specific and reliable isocratic high-performance liquid chromatography combined with quadrupole time-of-flight electrospray ionization tandem mass spectrometry (LC/Q-TOF-ESI-MS/MS) method has been developed and validated for the identification and characterization of stressed degradation products of metoprolol. Metoprolol, an anti-hypertensive drug, was subjected to hydrolysis (acidic, alkaline and neutral), oxidation, photolysis and thermal stress, as per ICH-specified conditions. The drug showed extensive degradation under oxidative and hydrolysis (acid and base) stress conditions. However, it was stable to thermal, neutral and photolysis stress conditions. A total of 14 degradation products were observed and the chromatographic separation of the drug and its degradation products was achieved on a C(18) column (4.6 × 250 mm, 5 μm). To characterize degradation products, initially the mass spectral fragmentation pathway of the drug was established with the help of MS/MS, MS(n) and accurate mass measurements. Similarly, fragmentation pattern and accurate masses of the degradation products were established by subjecting them to LC-MS/QTOF analysis. Structure elucidation of degradation products was achieved by comparing their fragmentation pattern with that of the drug. The degradation products DP(2) (m/z 153) and DP(14) (m/z 236) were matched with impurity B, listed in European Pharmacopoeia and British Pharmacopoeia, and impurity I, respectively. The LC-MS method was validated with respect to specificity, linearity, accuracy and precision.  相似文献   

19.
CCl4 对左旋氧氟沙星超声降解的影响   总被引:2,自引:0,他引:2  
研究了CCl4对超声降解喹诺酮类抗生素左旋氧氟沙星(Levofloxacin)的影响, 考察了CCl4添加量、 超声功率、 溶液初始pH值及左旋氧氟沙星初始浓度等影响因素, 并采用HPLC和LC-MS/MS对超声降解产物进行了初步分析. 结果表明, CCl4增强了左旋氧氟沙星的超声降解, 当反应液体积为50 mL, 超声35 min时, 随着CCl4体积分数的增大(0~0.06%), 左旋氧氟沙星的降解率由1.9%增至69.2%; 超声功率为100~200 W时, 降解率随着功率的升高而增大, 功率为200~400 W时降解率有所降低; pH值对左旋氧氟沙星的超声降解影响很大, pH =7.14时容易超声降解, pH过低或过高均导致降解率显著减小; CCl4的体积分数一定时, 左旋氧氟沙星的降解率随其初始浓度的增大而降低; 左旋氧氟沙星的降解率在33~49 ℃时最大. CCl4强化超声降解左旋氧氟沙星过程主要是由·OH和一系列氯自由基参与的反应. HPLC分析发现, 降解过程中同时生成了2个产物, 并通过LC-MS/MS对其进一步鉴定.  相似文献   

20.
Application of the HPLC hyphenated techniques of LC-two-dimensional (2D) NMR using pre-concentration column trapping and LC-MS was demonstrated by the identification of two major degradation products, DP-1 and DP-2, in stressed commercial tablets of amlodipine maleate. The molecular formulas were estimated by LC-MS. Sample pre-concentration by column trapping was conducted to obtain adequate 2D-NMR signals by reducing the peak widths of the degradation products and making sure that the maximum amount of each component was inside the flow cell for NMR detection. Double-quantum filtered correlation spectroscopy (DQF-COSY) was applied to identify DP-1 as beta-N-lactosylamlodipine by suppressing the residual water signal without affecting the sample signal and by measuring the coupling constant of the lactose anomeric proton. Heteronuclear multiple bond coherence spectroscopy (HMBC) was applied to characterize DP-2 as an aspartic acid derivative of amlodipine by detecting long-range CH correlations. The chemical structures of the degradation products could be successfully elucidated unambiguously without an isolation process.  相似文献   