1.

Purpose

The purpose of our study was to compare diffusion-weighted MR imaging (DWI) with conventional dynamic MRI in terms of the assessment of small intrahepatic metastases from hepatocellular carcinoma (HCC).

Materials and Methods

In 24 patients with multifocal, small (≤2 cm) intrahepatic metastatic foci of advanced HCC, a total of 134 lesions (≤1 cm, n=81; >1 cm, n=53) were subjected to a comparative analysis of hepatic MRI including static and gadopentetate dimeglumine-enhanced dynamic imaging, and DWI using a single-shot spin-echo echo-planar MRI (b values=50, 400 and 800 s/mm2), by two independent reviewers.

Results

A larger number of the lesions were detected and diagnosed as intrahepatic metastases on DWI [Reviewer 1, 121 (90%); Reviewer 2, 117 (87%)] than on dynamic imaging [Reviewer 1, 107 (80%); Reviewer 2, 105 (78%)] (P<.05). For the 81 smaller lesions (≤1 cm), DWI was able to detect more lesions than dynamic imaging [Reviewer 1, 68 (84%) vs. 56 (69%), P=.008; Reviewer 2, 65 (80%) vs. 55 (68%), P=.031], but there was no statistically significant difference between the two image sets for larger (>1 cm) lesions.

Conclusion

Due to its higher detection rate of subcentimeter lesions, DWI could be considered complementary to dynamic MRI in the diagnosis of intrahepatic metastases of HCCs.  相似文献   

2.

Purpose

To evaluate the usefulness of diffusion-weighted magnetic resonance imaging (DW-MRI) in the differentiation of cystic pancreatic lesions.

Materials and Methods

Institutional review board approval was obtained, and written informed consent was taken from all enrolled subjects. Fifty-four patients with cystic pancreatic lesions of at least 1 cm in diameter (range:10–96 mm) at ultrasonography and/or computed tomography and 10 normal subjects underwent MRI at 1.5 T. These subjects included thirty-four patients with intraductal papillary mucinous tumors (IPMTs), 10 with pseudocysts, 5 with serous cystoadenoma and 5 with mucinous cystoadenoma. The MR protocol included axial T1w and T2w sequences and coronal MR cholangiopancreatography images. DW-MRI was performed using a breath-hold single-shot echo-planar sequence with a b gradient factor value of 500 s/mm2 in the three orthogonal axes. Apparent diffusion coefficient (ADC) was calculated for cerebrospinal fluid, normal pancreatic parenchyma, and for each focal pancreatic lesion. Imaging results were correlated with endoscopic retrograde cholangiopancreatography, endoscopic ultrasound-guided fine needle aspiration, surgery and/or imaging follow-up.

Results

Mean ADC value was 4.1×10−3 mm2/s for cerebrospinal fluid, 1.73×10−3 mm2/s for normal pancreatic parenchyma, 4.09×10−3 mm2/s for IPMT, 3.89×10−3 mm2/s for mucinous cystoadenoma, 3.65×10−3 mm2/s for serous cystoadenoma and 2.83×10−3 mm2/s for pseudocyst. Mean ADC values of each of the different types of pancreatic lesions were statistically different (P<.05).

Conclusion

DW-MRI may be helpful in the differential diagnosis of cystic pancreatic lesions.  相似文献   

3.

Purpose

The purpose of the study was to validate diffusion-weighted imaging (DWI) in the assessment of hypervascular hepatocellular carcinoma (HCC) compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging (MRI) in the cirrhotic liver.

Material and Methods

Forty-six consecutive patients with 106 hypervascular focal lesions in the cirrhotic liver who underwent DWI using three b factors and gadopentetate dimeglumine-enhanced dynamic MRI followed by SPIO-enhanced MRI were enrolled. Two independent radiologists evaluated two separated image sets (SPIO set, dynamic MRI and SPIO-enhanced T2*-weighted images; DWI set, DWI and dynamic MRI) and assigned confidence levels for diagnosis of HCC using a five-point scale for each lesion. Area under the receiver operating characteristic curve (Az) was calculated for each image set.

Results

The Az value of the DWI set was larger than the SPIO set by both readers (reader 1, 0.936 vs. 0.900, P=.050; reader 2, 0.938 vs. 0.905, P=.110). For the sensitivity (reader 1, 93.1% vs. 86.2%, P=.146; reader 2, 95.4% vs. 88.5%, P=.070) and specificity (reader 1, 89.5% vs. 73.7%, P=.250; reader 2, 79.0% vs. 73.7%, P=1.000) of HCC diagnosis, DWI sets were superior to SPIO sets without statistically significant differences.

Conclusion

For assessment of hypervascular HCC, DWI in combination with dynamic MRI provides comparable or slightly better information compared with the combination of dynamic and SPIO-enhanced MRI.  相似文献   

4.

Purpose

To present diffusion and perfusion magnetic resonance imaging (MRI) characteristics of focal nodular hyperplasia (FNH) of the liver.

Materials and Methods

Thirty-five patients with 52 FNHs (21 were pathologically-confirmed) underwent MRI at 1.5-T device. MR diffusion [diffusion-weighted imaging (DWI)] was performed using a free-breathing single-shot, spin-echo, echo-planar sequence with b gradient factor value of 500 s/mm². MR perfusion [perfusion-weighted imaging (PWI)] consisted of a 3D free-breathing LAVA sequence repeated up to 5 minutes after injection of 7 mL Gd-BOPTA (MultiHance, Bracco, Italy) and 20 mL saline flush at a flow rate of 4 mL/s. Apparent diffusion coefficient (ADC) and time-signal intensity curve (TSIC) were obtained for both normal liver and each FNH by two reviewers in conference; maximum enhancement (ME) percentage, time to peak enhancement (TTP), and maximal slope (MS) were also calculated.

Results

On DWI mean ADC value was 1.624×10− 3 mm2/s for normal liver and 1.629×10− 3 mm2/s for FNH. ADC value for each FNH and the normal liver was not statistically different (P= .936). On PWI, TSIC-Type 1 (quick and marked enhancement and quick decay followed by slowly decaying) was observed in all 52 FNHs, and TSIC-Type 2 (fast enhancement followed by slowly decaying plateau) in all normal livers. The mean ME, TTP and MS values were significantly different for FNH and normal liver (P= .005).

Conclusion

FNHs of the liver showed typical diffusion and perfusion MRI characteristics in all cases. On the ADC map, we could get similar value between the FNHs and the background parenchyma. On the perfusion imaging, FNHs showed a different pattern distinguished from the background liver.  相似文献   

5.
The effect of superparamagnetic iron oxide particles on magnetic resonance myocardial signal intensity was examined in order to define the ability of this agent to identify normal, ischemic, and reperfused myocardium. Data were obtained from 6 normal rats (group 1) and from 6 heterotopic isogenic rat heart transplants (group 2) at 4.7 T with a multislice spin-echo sequence. Images were acquired in (a) normal rats before and after the infusion of 36 μmol Fe/kg of AMI-25 (group 1) and (b) rat heart transplants during control, global myocardial ischemia (before and after the injection of 72 μmol Fe/kg of AMI-25), and following reperfusion (group 2). Myocardial signal intensity decreased by 36 ± 4%, p < 0.001, following contrast infusion in normal hearts (group 1). The intensity remained constant in the rat heart transplants (group 2) during coronary occlusion, both before and after the infusion of AMI-25 and decreased by 61 ± 7%, p < 0.001, upon reperfusion. The larger effect of AMI-25 in reperfused as compared to normal myocardium suggests the presence of ischemia-induced hyperemia. There was no significant difference (analysis of variance) among intensities from different myocardial regions in either group at any stage of the experiment. We conclude that the use of AMI-25 permits identification of normal, ischemic, and reperfused myocardium and may therefore be helpful for the early detection of reperfusion following thrombolytic therapy for acute myocardial infarction.  相似文献   

6.
We report a novel flocculation-redispersion method to synthesize and purify the biocompatible superparamagnetic ultrasmall iron oxide (USPIO) nanoparticles coated with carboxyl dextran derivative. First, USPIO nanoparticles were synthesized and flocculated to form the large clusters through bridging effect of polyvinyl alcohol (PVA) during coprecipitation process. Then the flocculated USPIO was separated and purified from the solution conveniently through magnetic sedimentation. Finally, USPIO in the clusters were released again and well dispersed through electrostatic repelling effect of citric acid with the aid of ultrasonic. The dispersed carboxyl-functionalized USPIO was conjugated with the monoclonal antibodies. And it has been proved that the antibodies anchored on USPIO still retained their bioactivity after the conjugation. These results implied that the USPIO synthesized have good potential as active targeting molecular probe in biomedical application.  相似文献   

7.
In this study, the volume of susceptibility artifact was evaluated in T1 and T2-weighted spin echo (SE) and gradient echo (GRE) images at various parameters using registration and subtraction methods. In order to state an important misinterpretation problem in lymphography, it was demonstrated that a lymph node size may be enlarged approximately 10 times when a T2*-weighted GRE protocol is used. To overcome this problem a technical consideration using multisequence (GRE and SE) paradigm was suggested to ensure both lymph node detection and metastasis identification in lymphatic system. The paradigm was also extended by post-processing manipulation of the SE images using a registration and subtraction approach for detection of lymphatic lesions.  相似文献   

8.
The purpose of this study was to evaluate the potential of superparamagnetic iron oxide particles (SPIO) as tissue specific contrast agent in magnetic resonance (MR) imaging in detection and characterization of focal hepatic lesions. We investigated 45 patients with focal hepatic lesions. T1-weighted SE (TR 650/TE 15 ms) and T2-weighted SE (TR 2015-2030/TE 45 and 90 ms) unenhanced images were obtained. After SPIO application we performed T1-weighted images with and T2-weighted images with and without fat suppression using the same image parameters. Liver signal intensity decreased by 74% (min 47%, max 83%) on T2-weighted images after application of the contrast agent. Benign lesions (FNH, adenoma) showed an average signal drop of 40% (min 20%, max 47%) whereas malignant lesions showed no significant change of signal intensity on post-contrast images. The mean tumor-to-liver contrast-to-noise ratio (C/N) was improved in all post-contrast sequences irrespective of the lesion type. An additional increase of tumor-to-liver contrast by use of fat suppression technique could be established in the slightly T2-weighted sequence (TE 45 ms). In metastases, divided in different size groups, we could determine a significant size relation of tumor-to-liver C/N. After SPIO application the number of detected lesions increased distinctly, especially small foci are more easily demonstrated. SPIO particles are a efficacious contrast agent for MR examinations of the liver. For tumor characterization T1- and T2-weighted pre- and post-contrast images are necessary. The T1-weighted sequences are helpful to differentiate benign lesions such as cysts and hemangiomas from malignant lesions. Detection and differential diagnoses of hepatic lesions are improved by use of the SPIO-particles.  相似文献   

9.

Purpose

To assess the feasibility of full diffusional kurtosis tensor imaging (DKI) in prostate MRI in clinical routine. Histopathological correlation was achieved by targeted biopsy.

Materials and Methods

Thirty-one men were prospectively included in the study. Twenty-one were referred to our hospital with increased prostate specific antigen (PSA) values (> 4 ng/ml) and suspicion of prostate cancer. The other 10 men were volunteers without any history of prostate disease. DKI applying diffusion gradients in 20 different spatial directions with four b-values (0, 300, 600, 1000 s/mm2) was performed additionally to standard functional prostate MRI. Region of interest (ROI)-based measurements were performed in all histopathologically verified lesions of every patient, as well as in the peripheral zone, and the central gland of each volunteer.

Results

DKI showed a substantially better fit to the diffusion-weighted signal than the monoexponential apparent diffusion coefficient (ADC). Altogether, 29 lesions were biopsied in 14 different patients with the following results: Gleason score 3 + 3 = 6 (n = 1), 3 + 4 = 7 (n = 7), 4 + 3 = 7 (n = 6), 4 + 4 = 8 (n = 1), and 4 + 5 = 9 (n = 2), and prostatitis (n = 12). Values of axial (Kax) and mean kurtosis (Kmean) were significantly different in the tumor (Kax 1.78 ± 0.39, Kmean 1.84 ± 0.43) compared with the normal peripheral zone (Kax 1.09 ± 0.12, Kmean 1.16 ± 0.13; p < 0.001) or the central gland (Kax 1.40 ± 0.12, Kmean 1.44 ± 0.17; p = 0.01 respectively). There was a minor correlation between axial kurtosis (r = 0.19) and the Gleason score.

Conclusion

Full DKI is feasible to utilize in a routine clinical setting. Although there is some overlap some DKI parameters can significantly distinguish prostate cancer from the central gland or the normal peripheral zone. Nevertheless, the additional value of DKI compared with conventional monoexponential ADC calculation remains questionable and requires further research.  相似文献   

10.
The purpose of this study was to investigate the feasibility of diffusion-weighted imaging (DWI) in detecting synovitis of wrist and hand in patients with rheumatoid arthritis (RA) and evaluate its sensitivity, specificity and accuracy as compared to T2-weighted imaging (T2WI) with short tau inversion recovery (STIR) with the reference standard contrast-enhanced magnetic resonance imaging (CE-MRI). Twenty-five patients with RA underwent MR examinations including DWI, T2WI with STIR and CE-MRI. MR images were reviewed for the presence and location of synovitis of wrist and hand. The sensitivity, specificity and accuracy of DWI and T2WI with STIR were calculated respectively and then compared. All patients included in this study completed MR examinations and yielded diagnostic image quality of DWI. For individual joint, there was good to excellent inter-observer agreement (k = 0.62–0.83) using DWI images, T2WI with STIR images and CE-MR images, respectively. There was a significance between DWI and T2WI with STIR in analyzing proximal interphalangeal joints II–V, respectively (P < 0.05). The k-values for the detection of synovitis indicated excellent overall inter-observer agreements using DWI images (k = 0.86), T2WI with STIR images (k = 0.85) and CE-MR images (k = 0.91), respectively. Overall, DWI demonstrated a sensitivity, specificity and accuracy of 75.6%, 89.3% and 84.6%, respectively, for detection of synovitis, while 43.0%, 95.7% and 77.6% for T2WI with STIR, respectively. DWI showed positive lesions much better and more than T2WI with STIR. Our results indicate that DWI presents a novel non-invasive approach to contrast-free imaging of synovitis. It may play a role as an addition to standard protocols.  相似文献   

11.
Superparamagnetic iron oxide nanoparticles (SPIONs) were coated with polyethylenimine. Here, we briefly describe the synthesis as well as DNA:PEI:SPION complexes and the characterization of the compounds according to their particle size, ζ-potential, morphology, DNA complexing ability, magnetic sedimentation, and colloidal stability. PEI coating of SPIONs led to colloidally stable beads even in high salt concentrations over a wide pH range. DNA plasmids and PCR products encoding for green fluorescent protein were associated with the described beads. The complexes were added to cells and exposed to permanent and pulsating magnetic fields. Presence of these magnetic fields significantly increased the transfection efficiency.  相似文献   

12.
PURPOSE: The aim of this study was to evaluate the frequency and magnetic resonance imaging (MRI) features of clinically benign, small (<2 cm) hyperintense hepatic lesions in the cirrhotic liver on T1-weighted MR images seen at serial MRI. MATERIALS AND METHODS: This study included 189 patients with cirrhosis, who underwent hepatic MRI more than twice with an interval of at least 12 months. The initial MR images were reviewed for the presence of small hyperintense lesions on T1-weighted images. The size, location and signal intensity on T2-weighted images as well as enhancement patterns of the corresponding lesions were recorded. RESULTS: On the initial T1-weighted MR images, 43 small hyperintense hepatic lesions were detected in 23 (12%) of 189 patients. Twelve (28%) of 43 lesions showed early enhancement and were pathologically diagnosed as hepatocellular carcinoma (HCC) during the follow-up period. Thirty-one (72%) of 43 lesions showed no early enhancement with various signal intensity on T2-weighted images (hyperintensity=4, isointensity=20, hypointensity=7). Among these 31 lesions, 12 showed no interval change, while 11 disappeared (n=10) or decreased in size (n=1). In the remaining eight lesions, seven were diagnosed as HCC on the basis of pathologic confirmation or the interval growth. CONCLUSION: Small hyperintense hepatic lesions on T1-weighted magnetic resonance (MR) images without early enhancement on the arterial-phase contrast-enhanced dynamic studies in patients with cirrhosis usually showed no interval growth or disappeared during the serial MRI. These lesions with additional findings of iso- or hypointensity on the T2-weighted MR images without "washout effect" on the contrast-enhanced equilibrium-phase images may more frequently be clinically benign or hyperplastic nodules than HCCs.  相似文献   

13.
14.
Liver iron concentration was determined in 28 patients by magnetic resonance imaging using the method of Gandon et al. (Non-invasive assessment of hepatic iron stores by MRI. Lancet 2004;363:357-362). The result showed a significant correlation with blood plasma ferritin content (Spearman's r=.66; P<.001) and a slightly improving correlation coefficient when limited to those patients not known to have inflammation (r=.82; n=17; P<.001). Zooming in on patients with hematologic disease also had a beneficial effect on the correlation between liver iron content and plasma ferritin level (r=.79; n=13; P=.001). It is concluded that in patients without inflammation and in patients with hematologic disease, the content of ferritin in blood is a better predictor of liver iron content than in other patient categories.  相似文献   

15.
This study was conducted to compare the sensitivity and specificity of abdominal magnetic resonance imaging using oral superparamagnetic iron oxide with oral contrast-enhanced computed tomography in the detection of GI pathology. Overall sensitivity was calculated to be 83% for OECT compared to 67% by SPIO MRI. Specificity for OECT was 68% compared to 89% for SPIO MRI. The results from imaging with superparamagnetic iron oxide and imaging with oral contrast-enhanced computed tomography were in agreement in 14 subjects who had normal gastrointestinal tracts. In the remaining 16 patients, eight pathologic entities were detected by both modalities whereas 15 abnormalities were seen by only one modality. Superparamagnetic iron oxide magnetic resonance imaging was helpful in discriminating normal bowel from solid lesions and in detecting subtle gastrointestinal tract mass effect. In 30 consecutively studied patients suspected of having GI pathology, OECT was more sensitive than SPIO MRI in detecting abdominal pathology. Conversely, SPIO MRI was more specific than OECT.  相似文献   

16.

Purpose

To investigate whether image quality can be improved using liquid perfluorocarbon pads (Sat Pad) and clarify the optimal fat-suppression method among chemical shift selective (CHESS), water excitation (WEX), and short TI inversion recovery (STIR) methods in diffusion-weighted imaging (DWI) of the head and neck using 3-T magnetic resonance imaging. Correlations between results of visual inspection and quantitative analysis were also examined.

Material and Methods

This study was approved by our Institutional Review Board and informed consent was waived. DWI was performed on 25 subjects with/without Sat Pad and using three fat-suppression methods (6 patterns). Image quality was evaluated visually (4-point scales and lesion-depiction capability) and by quantitative analysis (signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)). Two-way repeated-measures analysis of variance (ANOVA) was used to detect significant differences in scores of visual evaluation, SNR, and CNR.

Results

Mean visual evaluation scores were significantly higher with Sat Pad using STIR than without Sat Pad for all fat-suppression methods (P < 0.05). DWI with Sat Pad using STIR tended to be useful for depicting lesions. DWI using STIR showed reduced W-SNR (W: whole area of depicted structure) and CNR (between semispinalis capitis muscle and subcutaneous fat) due to fewer artifacts and uniform fat suppression.

Conclusion

Combining Sat Pad with STIR provides good image quality for visual inspections. When numerous artifacts are present and fat suppression is insufficient, higher SNR and CNR do not always provide good diagnostic image quality.  相似文献   

17.
Superior mesenteric lymph nodes which lie as a chain near the small intestine are difficult to visualize in the rat with MRI either with or without the use of contrast agents. We previously demonstrated that the oral administration of an ultrasmall superparamagnetic iron oxide (AMI-227) produces a brightening of the lumen of the GI tract with a T1-weighted spin-echo pulse sequence. We have also shown that AMI-227 darkens abdominal lymph nodes. In the present study we show that the combined oral and intravenous administration of AMI-227 produces a brightening of the lumen of the GI tract and a darkening of the superior mesenteric lymph node chain. As a result of these combined and opposing effects on image signal intensity, a necessary contrast is established to reliably locate the superior mesenteric lymph nodes in vivo, which, to our knowledge, have been elusive by other techniques.  相似文献   

18.

Purpose

To evaluate the apparent diffusion coefficient (ADC) of skeletal muscle based on signal intensity (SI) attenuation vs. increasing b values and to determine ADC differences in skeletal muscles between genders, age groups and muscles.

Materials and Methods

Diffusion-weighted images (b values in the range of 0–750 s/mm2 at increments of 50 s/mm2) of the ankle dorsiflexors (116 subjects) and the erector spinae muscles (86 subjects) were acquired with a 1.5-T MR device. From the two different slopes obtained in SI vs. b-value logarithmic plots, ADCb0–50 (b values=0 and 50 s/mm2) reflected diffusion and perfusion, while ADCb50–750 (b values in the range of 50–750 s/mm2 at increments of 50 s/mm2) approximated the true diffusion coefficient. Moreover, to evaluate whether this b-value combination is appropriate for assessing the flow component within muscles, diffusion-weighted images of the ankle dorsiflexors (10 subjects) were obtained before and during temporal arterial occlusion.

Results

ADCb0–50 and ADCb50–750 were found to be 2.64×10–3 and 1.44×10–3 mm2/s in the ankle dorsiflexors, and 3.02×10–3 and 1.49×10–3 mm2/s in the erector spinae muscles, respectively. ADCb0–50 was significantly higher than ADCb50–750 in each muscle (P<.01). The erector spinae muscles showed significantly higher ADC values than the ankle dorsiflexors (P<.01). However, for each muscle, there were few significant gender- and age-related ADC differences. Following temporal occlusion, ADCb0–50 of the ankle dorsiflexors decreased significantly from 2.49 to 1.6×10–3 mm2/s (P<.01); however, ADCb50–750 showed no significant change.

Conclusion

Based on the SI attenuation pattern, muscle ADC could be divided into ADC that reflects both diffusion and perfusion, and ADC that approximates a true diffusion coefficient. There were significant differences in ADC of functionally distinct muscles. However, we barely found any gender- or age-related ADC differences for each muscle.  相似文献   

19.

Purpose

To evaluate the liver-to-muscle signal intensity and R2* methods to gain a transferable, clinical application for liver iron measurement.

Materials and Methods

Sixteen liver phantoms and 33 human subjects were examined using three 1.5-T MRI scanners from two different vendors. Phantom-to-muscle and liver-to-muscle signal intensity ratios were analyzed to determine MRI estimated phantom and hepatic iron concentration (M-PIC and M-HIC, respectively). R2* was calculated for the phantoms and the liver of human subjects. Seven patients' biochemical hepatic iron concentration was obtained.

Results

M-PIC and R2* results of three scanners correlated linearly to phantom iron concentrations (r=0.984 to 0.989 and r=0.972 to 0.981, respectively), and no significant difference between the scanners was found (P=.482 and P=.846, respectively) in vitro. The patients' R2* correlated linearly to M-HIC of the standard scanner (r=0.981). M-HIC values did not differ from those obtained from the biopsy specimens (P=.230). The difference in M-HIC was significant, but the difference in R2* was not significant between the scanners (P<.0001 and P=.505, respectively) in vivo.

Conclusion

Both methods, M-HIC and R2*, are reliable iron concentration indicators with linear dependence on iron concentration in vivo and in vitro. The R2* method was found to be comparable among different scanners. Transferability testing is needed for the use of the methods at various scanners.  相似文献   

20.

Objective

The purpose of this study was to assess the influence of liver cirrhosis and portal hypertension on diffusion coefficients of the spleen.

Material and Methods

We retrospectively evaluated 50 patients with liver cirrhosis and 50 patients without any history of liver disease who underwent magnetic resonance imaging of the upper abdomen, including echo planar diffusion-weighted imaging using b values of 50, 300 and 600 mm2/s. Spleen apparent diffusion coefficient (ADC), liver ADC, muscle ADC and normalized spleen ADC (defined as the ratio of spleen ADC to muscle ADC) were compared between cirrhotic patients and patients in the control group and correlated with Child–Pugh stages. Reproducibility was assessed by measuring interclass correlation coefficient (n = 11). Additionally, in eight patients, ADC measurements were performed 1 day before and 3 days after transjugular intrahepatic portosystemic shunt (TIPSS) implantation.

Results

Compared with control subjects, patients with cirrhosis and portal hypertension had significantly higher spleen ADCs (P = .0001). There was a statistically significant correlation between Child–Pugh grade and spleen ADC (Pearson correlation coefficient, observer 1 r = 0.6, P = .0001; observer 2 r = 0.5, P = .0001). After TIPSS implantation, we observed a reduction in spleen ADC values. Spleen ADC measurements showed a high reproducibility (interclass correlation coefficient 0.75, P = .001).

Conclusion

Our data suggest that different stages of liver cirrhosis and portal hypertension correlate with ADC values of the spleen. Furthermore, ADC values of the spleen decrease after TIPSS implantation. Further studies are required to understand the potential clinical values of these observations.  相似文献   