首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 0 毫秒
1.
The flexural modulus of polymeric foams determined from three-point bending tests is usually inaccurate due to the local deformation undergone by the material during testing. The machine used in the test gives deflection values larger than the actual deflection of the foam specimen due to the deformation of the material at the loading point. This leads to errors in the computation of the modulus value. In this work, the deflection values of a beam made of polymeric foam in a three-point bending test were determined using the moiré method. The change in the moiré pattern at the neutral axis of the foam during loading was recorded and converted into deflection values. The deflection data were used to generate the stress–strain curve from which the flexural modulus of the foam material was determined. The proposed method was verified using aluminum beams, where a high correlation between the deflection data from the machine readings and the moiré method was obtained. The flexural modulus of the foam determined using the moiré method was found to be within 3% of the value published in the material data sheet.  相似文献   

2.
3.
4.
An HPLC method has been developed for the fast separation and quantification of permethrin using C18 column packed with 1.8 μm particles. The method is specific with good resolution to degradation products and to other present components. It has acceptable validation results. The run time is 4.5 min (or may be within 1.6 min is rapid resolution mode) with an organic solvent consumption of 3.6 mL per run. The method has been applied to samples of formulations for various uses: mattress cleaner, shampoo, and veterinary powder. The performance of the applied column is compared with other common column types. The relationships between linear velocity of the mobile phase (u) and resolution factor (Rs), back-pressure (ΔP), and efficiency (H) are presented. The experimental data shows the advantages of 1.8-μm particle columns to be a significant reduction in solvent consumption (by factor of 4.4 and 1.5) and a reduction in run-time (by factor 4.7 and 1.5), and the weaknesses are a high back-pressure and lower efficiency. Finally, it has been shown that use of 1.8-μm particle packed columns with conventional HPLC systems is possible, but with limitations in mobile phase flow-rate.  相似文献   

5.
Hydrophobic silica aerogels possesses potential applications as insulating materials for refrigerators, furnaces and thermos flasks. In such applications, aerogel materials may get exposed for longer time to atmosphere and the adsorbed water content from surroundings may deteriorate its properties. Therefore, hydrophobicity of the arogels becomes crucial parameter and needs to be evaluated critically. In the present works, silica alcogels were prepared using the mixture of tetramethoxysilane and methyltrimethoxysilane (MTMS) as precursor chemicals for silica. The concentration of MTMS, which is used as hydrophobic reagent, in the said mixture of silicon alkoxide was varied between 0 and 100% in steps of 25%. After gelation, the alcogels were dried supercritically by solvent extraction method. Resulted aerogels were exposed to relative humidity of 90% for a period of one month which were then characterized to assess hydrophobicity by the contact angle using water drop method and adsorbed water content measurements by Karl Fischer’s Titration method. Observed contact angle and water content measurements were compared and the results are reported in the present research paper.  相似文献   

6.
7.
The aim of this study was to establish a high-throughput and sensitive LC–MS/MS method for the determination of doxepin and its major active metabolite nordoxepin in human plasma. It has been designed for bioequivalence study for formulations containing 25 mg of doxepin. Doxepin and nordoxepin were extracted from human plasma samples by protein precipitation with acetonitrile by using protein precipitation 96-well plates. The analyte was separated using a Phenomenex Kinetex Biphenyl column (100 × 2.1 mm, 2.6 μm) using isocratic elution with a mobile phase of 20 mM ammonium formate (30%) and acetonitrile:methanol 3:7 v:v (70%) at a flow rate of 0.5 mL/min and an injection volume of 10 μL. The detection was performed using a triple quadrupole mass spectrometer by multiple reaction monitoring mode to monitor the precursor-to-product ion transitions of m/z 280.4 → 107.0 and 283.4 → 235.0 for doxepin and doxepin-D3, respectively, and 266.3 → 106.9 and 269.3 → 235.0 for nordoxepin and nordoxepin-D3, respectively, in positive electrospray ionization mode. The total run time was 3.5 min. The method was validated over a concentration range of 50–10,000 pg/mL using a Triple Quad 4500 MS System (Sciex) for both analytes. The developed and validated method can be successfully used to study the bioequivalence/pharmacokinetics of doxepin and nordoxepin.  相似文献   

8.
This paper presents the application of an efficient method for extraction and fractionation of intact phospholipids (PLs) from complex sediment matrices and elucidation of their molecular structure by normal-phase HPLC–ESI-MS–MS. Flow-blending extraction was tested with different solvent mixtures and the best recovery of all PLs classes from the sediment matrix was achieved by using methanol–dichloromethane–buffer, 2:1:0.8. The applied LC–ESI-MS system has linearity of R2=0.98 and a detection limit of 0.5 ng/PL, sufficient for reliable identification of complex mixtures of PLs. MS–MS analyses using a triple-quadrupole mass spectrometer enables detection of individual PL side-chain composition and, hence, characterization of the living organisms contributing to the sedimentary organic material. Parallel GC–MS analysis of the hydrolysed phospholipid fatty acids supports the characterized fatty acid patterns determined from intact PLs. The PL inventory of different investigated lacustrine surface sediments shows predominantly high abundance of phosphatidylglycerols and phosphatidylethanolamines and phosphatidyl-mono- and dimethyl-ethanolamines with fatty acyl side-chains typically known from bacteria. In a sample from Lake Baikal intense signals of bacterial 14:0-acyl-PGs were also identified, for the first time in sediments as far as we are aware.  相似文献   

9.
CuAlO2 thin films were deposited on quartz substrates by sol–gel process using copper acetate monohydrate and aluminum nitrate nanohydrate as starting materials and isopropyl alcohol as solvent. The influence of annealing temperature on the film structure and the phase evolution of CuAlO2 films were investigated, so as to obtain CuAlO2 films with superior performance. The phase compositions of the films were dependent on the annealing temperature. The films annealed at temperatures below 400 °C were amorphous while those annealed above 400 °C were polycrystalline. The phases of CuO and CuAl2O4 appeared gradually with the increase of annealing temperature. When the heat treatment temperature was elevated to 900 °C, the uniform and dense films with single phase of CuAlO2 were obtained, with a resistivity of 15 Ωcm. The transmittance of the 310 nm-thick CuAlO2 film is 79% at 780 nm and the direct optical band gap is 3.43 eV.  相似文献   

10.
11.
Kurumanna  A.  Ashok  K.  Rambabu  S.  Sonyanaik  B.  Ravi  D.  Madhu  P.  Sakram  B. 《Russian Journal of General Chemistry》2017,87(11):2703-2711
Russian Journal of General Chemistry - A novel and efficient aromatization of tetrahydro-β-carbolines under mild conditions using K2S2O8 as a catalyst was developed. The method is applicable...  相似文献   

12.
Mercury in plants or animal tissue is supposed to occur in the form of complexes formed with biologically relevant thiols (biothiols), rather than as free cation. We describe a technique for the separation and molecular identification of mercury and methylmercury complexes derived from their reactions with cysteine (Cys) and glutathione (GS): Hg(Cys)2, Hg(GS)2, MeHgCys, MeHgGS. Complexes were characterised by electrospray mass spectrometry (MS) equipped with an ion trap and the fragmentation pattern of MeHgCys was explained by using MP2 and B3LYP calculations, showing the importance of mercury–amine interactions in the gas phase. Chromatographic baseline separation was performed within 10 min with formic acid as the mobile phase on a reversed-phase column. Detection was done by online simultaneous coupling of ES-MS and inductively coupled plasma MS. When the mercury complexes were spiked in real samples (plant extracts), no perturbation of the separation and detection conditions was observed, suggesting that this method is capable of detecting mercury biothiol complexes in plants. Figure Separation and structural identification of Hg and MeHg biothiols A part of this work was presented as a poster at the European Winter Conference on Plasma Spectrochemistry, 2007, held in Taormina, Italy.  相似文献   

13.
A novel method is developed for the direct determination of naphazoline hydrochloride(NAP) and pyridoxine hydrochloride(VB6) in commercial eye drops. By using excitation–emission matrix(EEM)fluorescence coupled with second-order calibration method based on the alternating trilinear decomposition(ATLD) algorithm, the proposed approach can achieve quantitative analysis successfully even in the presence of unknown and uncalibrated interferences. The method shows good linearity for NAP and VB6 with correlation coefficients greater than 0.99. The results were in good agreement with the labeled contents. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring(MRM) based on LC–MS/MS method.T-test demonstrated that there are no significant differences between the prediction results of the two methods. The satisfactory results obtained in this work indicate that the use of the second-order calibration method coupled with the EEM is a promising tool for industrial quality control and pharmaceutical analysis due to its advantages of high sensitivity, low-cost and simple implementation.  相似文献   

14.
Three novel thiaazacrown ethers 1, 2 and 3 were synthesized in a simple way and in high yield. The complex formation between Ag+, Cu2+, Zn2+, Pb2+, Hg2+ and Cd2+ metal cations with thiaazacrown ethers 1, 2 and 3 have been studied in acetonitrile:chloroform (1:1) binary solvent system using conductometric technique. The conductance data show that the stochiometry of the complexes with Ag+, Cu2+ and Zn2+ cations is 1:1 (L:M), but in the case of Pb2+ and Hg2+ cations, a 1:2 (L:M) complex is formed in solutions. The formation constants of the resulting 1:1 complexes were determined from the molar conductance-mole ratio data at 25 °C. It was found that the stability constants of 1-Ag2+, 2-Ag+ and 3-Ag+ complexes are higher than those of their corresponding Zn2+ and Cu2+ complexes and found to vary in order 2 for Ag+.  相似文献   

15.
The optimization of a clean procedure based on ultrasound-assisted emulsification liquid-liquid microextraction for the sensitive determination of four bisphenols is presented. The miniaturized technique was coupled with gas chromatography-mass spectrometry after derivatization by in situ acetylation. The Taguchi experimental method, an orthogonal array design, was applied to find the optimal combination of seven factors (each factor at three levels) influencing the emulsification, extraction and collection efficiency, namely acetic anhydride volume, sodium phosphate concentration, carbon tetrachloride volume, aqueous sample volume, sodium chloride concentration and ultrasound power and application time. A second factorial design was applied with four factors and five levels for each factor, 25 experiments being performed in this instance. The matrix effect was evaluated, and it was concluded that sample quantification can be done by calibration with aqueous standards. The detection limits ranged from 0.01 to 0.03 ng mL(-1) depending on the compound. The environmentally friendly sample pretreatment procedure was applied to study the migration of the bisphenols from different types of samples: thermal printer paper, compact discs, digital versatile discs, small tight-fitting waistcoats, baby's bottles, baby bottle nipples of different materials and children's toys.  相似文献   

16.
A sensitive and rapid method based on alcoholic-assisted dispersive liquid–liquid microextraction followed by high-performance liquid chromatography for determination of citalopram in human plasma and urine samples was developed. The effects of six parameters (extraction time, stirring speed, pH, volume of extraction and disperser solvents, and ionic strength) on the extraction recovery were investigated and optimized utilizing Plackett–Burman design and Box–Behnken design, respectively. According to Plackett–Burman design results, the volume of disperser solvent, stirring speed, and extraction time had no effect on the recovery of citalopram. The optimized condition was a mixture of 172 µL of 1-octanol as extraction solvent and 400 µL of methanol as disperser solvent, pH of 10.3 and 1% w/v of salt in the sample solution. Replicating the experiment in optimized condition for five times, gave the average extraction recoveries equal to 89.42%. The detection limit of citalopram in human plasma was obtained 4 ng/mL, and the linearity was in the range of 10–1200 ng/mL. The corresponding values for human urine were 5.4 ng/mL with the linearity in the range of 10–2000 ng/mL. Relative standard deviations for inter- and intraday extraction of citalopram were less than 7% for five measurements. The proposed method was successfully implemented for the determination of citalopram in human plasma and urine samples.  相似文献   

17.
This paper introduces a new perspective for total-reflection X-ray fluorescence analysis (TXRF), that is the simultaneous determination of Ge, As, Sn and Sb in seawater. As is well known from atomic absorption spectroscopy (AAS) and inductively coupled plasma techniques (ICP) compounds of these elements can be reduced by sodium borohydride to their hydrides and thus separated from the matrix. In this work the hydride generation is used for matrix separation in TXRF measurements. For this purpose the following procedures are considered: (1) Preconcentration of hydrides by absorption in solvents, and evaporation of some μl of this solution on the sample carrier. (2) Decomposition of hydrides in a heated thin silica tube, or at rough and/or catalytically active surfaces, e.g. in adequately prepared columns, eluting of the species by acid and evaporation of some μl of this solution on the sample carrier. (3) Decomposition of hydrides directly on the surface of a heated silica sample carrier as a thin amorphous film. (4) Combustion of hydrides in the hydrogen flame and deposition of an elemental film on the sample carrier. Basically, all four ways have been tested and the results are promising. © 1997 Elsevier Science B.V.  相似文献   

18.
Gas-phase hydrogen abstraction reactions have been compared using the popular density functional theory(DFT) functional BHandHLYP/aug-cc-pVTZ/RECP level of theory,on the basis of the model reaction CHCl·-/CCl2·-+ CX3H(X = F,Cl,Br and I).Our theoretical findings suggest the efficiency of the H-abstraction reactions induced by either CHCl·-or CCl2·-increases as the substrate is changed from CF3H to CI3H,and that CHCl·-has a higher activity in hydrogen abstraction than CCl2·-for a given substrate.The entropy effect at 298 K does not significantly change the trend in reactivity of the various reactions,which is in general controlled by the heights of activation energies △E≠.Therefore,we have explored the origin of the energy barriers △E≠ of the reactions using the activation strain model of chemical reactivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号