首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cyclic peptides provide attractive lead compounds for drug discovery and excellent molecular probes in biomedical research. Large combinatorial libraries of cyclic peptides can now be routinely synthesized by the split-and-pool method and screened against biological targets. However, post-screening sequence determination of hit peptides has been problematic. In this report, a high-throughput method for the sequence determination of cyclic peptide library members has been developed. TentaGel microbeads (90 mum) were spatially segregated into outer and inner layers; cyclic peptides were displayed on the bead surface, whereas the inner core of each bead contained the corresponding linear peptide as the encoding sequence. After screening of the cyclic peptide library against a macromolecular target, the identity of hit peptides was determined by sequencing the linear encoding peptides inside the bead using a partial Edman degradation/mass spectrometry method. On-bead screening of an octapeptide library (theoretical diversity of 160 000) identified cyclic peptides that bind to streptavidin. A 400-member library of tyrocidine A analogues was synthesized on TentaGel macrobeads and solution-phase screening of the library directly against bacterial cells identified a tyrocidine analogue of improved antibacterial activity. Our results demonstrate that the new method for cyclic peptide sequence determination is reliable, operationally simple, rapid, and inexpensive and should greatly expand the utility of cyclic peptides in biomedical research.  相似文献   

2.
Electrospray mass spectrometry was used to simultaneously determine aspartame (APM) and five of its degradation products; aspartic acid, aspartylphenylalanine, 5-benzyl-3,6-dioxo-2-piperazieacetic acid (diketopiperazine), phenylalanine, and phenylalanine methyl ester. Under the ionization conditions used, there was no interfering fragmentation for any of the six compounds, i.e., no fragmentation of the compound being tested into other species also being monitored. A study of APM degradation in solution at various pH's and at various temperatures using this method was performed.  相似文献   

3.
The matrix metalloproteinase (MMP) family has been implicated in the process of a variety of diseases such as arthritis, atherosclerosis, and tumor cell metastasis. We have been designing single-stranded peptides (SSPs) and triple-helical peptides (THPs) as potential discriminatory MMP substrates. Edman degradation sequence and matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analyses of proteolytic activity have been utilized to aid in further substrate design. THP models of the alpha1(I)772-786 sequence from type I collagen were synthesized to examine the triple-helical substrate specificity of MMP family members. Sequence and MALDI-MS analyses were used in conjunction with a fluorometric assay to determine the exact point of cleavage by each MMP. MMP-1 (interstitial collagenase) cleaved the substrates at a single Gly-Ile bond, analogous to the cleavage site in type I collagen. MMP-2 (Mr 72 000 type IV collagenase; gelatinase A) was found to cleave the substrates at two sites, a Gly-Ile bond and a Gly-Gln bond. MMP-3 (stromelysin 1) was found to cleave only one of the substrates after reaction for 48 h. Ultimately, sequence and MALDI-MS analyses allowed us to detect an additional cleavage site for MMP-2 in comparison to MMP-1, while MMP-3 was found to cleave a substrate after an extended time period. The second cleavage site would cause the kinetic parameters for MMP-2 to be overestimated by the fluorometric assay. Further design variations for these substrates need to consider the presence of more stable triple-helical conformation (to eliminate MMP-3 binding) and the removal of Gly-Gln bonds that may be susceptible to MMP-2.  相似文献   

4.
Alkaline metal adduct ions of sphingomyelin were formed by electrospray ionization in positive ion mode. Under low energy collisionally activated dissociation (CAD), the product ion spectra yield abundant fragment ions representative of both long chain base and fatty acid which permit unequivocal determination of the structure. Tandem spectra obtained by constant neutral loss scanning permit identification of sphingomyelin class and specific long chain base subclass in the mixture. The fragmentation pathways under CAD were proposed, and were further confirmed by source CAD tandem mass spectrometry. The total analysis of sphingomyelin mixtures from bovine brain, bovine erythrocytes, and chicken egg yolk is also presented.  相似文献   

5.
Arsenic pollution of public water supplies has been reported in various regions of the world. Recently, some cancer patients are treated with arsenite (AsIII); most Japanese people consume seafoods containing large amounts of negligibly toxic arsenic compounds. Some of these arsenic species are metabolized, but some remain intact. For the determination of toxic AsIII, a simple, rapid and sensitive method has been developed using electrospray ionization mass spectrometry (ESI-MS). AsIII was reacted with a chelating agent, pyrrolidinedithiocarbamate (PDC, C4H8NCSS-) and tripyrrolidinedithiocarbamate-arsine, As(PDC)3, extracted with methyl isobutyl ketone (MIBK). A 1 μL aliquot of MIBK layer was directly injected into ESI-MS instrument without chromatographic separation, and was detected within 1 min. Arsenate (AsV) was reduced to AsIII with thiosulfate, and then the total inorganic As was quantified as AsIII. This method was validated for the analysis of urine samples. The limit of detection of As was 0.22 μg L−1 using 10 μL of sample solution, and it is far below the permissible limit of As in drinking water, 10 μg L−1, recommended by the WHO. Results were obtained in < 10 min with a linear calibration range of 1-100 μg L−1. Several organic arsenic compounds in urine did not interfere with AsIII detection, and the inorganic As in the reference materials SRM 2670a and 1643e were quantified after the reduction of AsV to AsIII.  相似文献   

6.
Bovine surfactant proteins B (SP-B) and C (SP-C) were analyzed by nano-electrospray ionization mass spectrometry (nano-ESI-MS). The observed molecular masses showed discrepancies compared to the calculated molecular masses using the published amino acid sequences. The number of cysteine residues in the published bovine SP-B amino acid sequences also failed to match the observed mass shift upon reduction of the SP-B dimer. To determine the amino acid sequences of two proteins, SP-B was first digested with trypsin and analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS), while SP-C was analyzed by MS/MS in its intact form. The amino acid sequence of bovine SP-B determined here matches the observed molecular mass. The sequence is almost identical to the sheep SP-B except for two amino acid residues, consistent with the proximity of the two species. The correct sequence contains seven cysteine residues. Bovine SP-B exists as dimers and all cysteines are oxidized to form disulfide bonds in physiological conditions, which is in agreement with the observed mass shift upon reduction of the SP-B dimer. These cysteine residues are completely conserved across all species indicating their importance for the biological functions of this surfactant protein. The sequence of SP-C determined here also reveals an L to V substitution at its position 22 compared with the published bovine SP-B sequence.  相似文献   

7.
This work compares several different methods of site-specific analysis of glycoproteins using electrospray mass spectrometry. The glycoprotein, oLHalpha (ovine luteinizing hormone, alpha-subunit) was chosen as an appropriate example protein for these studies because of its biological relevance and extreme microheterogeneity. More than 20 unique glycoforms were detected for this glycoprotein at the Asn(56) site of oLHalpha. The carbohydrates present at this site affect receptor binding affinity, so understanding the great variety in the composition of these carbohydrates is important in studying ligand binding interactions. MS data was acquired on a quadrupole ion trap, a triple quadrupole, and a quadrupole time of flight mass spectrometer, and carbohydrate composition at the Asn(56) site of oLHalpha was determined using these instruments. Additionally, neutral loss and precursor ion scanning modes were also used to identify the glycoforms present, and these techniques were compared to the standard MS data. Of the three instruments compared in the study, the qTOF mass spectrometer achieved the lowest sample consumption, but all three instruments were useful in profiling the glycopeptide composition.  相似文献   

8.
The degradation of the dye Indigo Carmine by hypochlorite in aqueous solution was monitored by electrospray ionization mass spectrometry in the negative ion mode (ESI(—)‐MS). Hypochlorite was highly efficient in removing the color of aqueous solutions of the dye. ESI(—)‐MS monitoring showed that concomitant with the Indigo Carmine consumption two transient species appeared (detected as doubly charged anions) probably formed via a net insertion of two hydroxyl groups at the exocyclic C?C bond followed by the incorporation of two (mainly) or one oxygen atoms at the indolic rings of the dye. Structures of these products were proposed based on the ESI(—)‐MS/MS data and high accuracy mass measurements. These two transient intermediates quickly decomposed, both in the condensed and in the gas phase, to yield mono‐charged anions. Based on these results, a route for the Indigo Carmine degradation by hypochlorite in aqueous solution has been proposed. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

9.
Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.  相似文献   

10.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

11.
Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human plasma samples was developed. The absolute minimum detection limit was around 10-20 pg per injection, corresponding to 0.5 ppb in an injection equivalent to 20-40microg of human plasma. Ochratoxin B (OTB) was used as an internal standard and its absence in real-life samples was carefully checked before samples were spiked with the internal standard. It was found that these two ochratoxins are susceptible to sodium adduct formation. Fragment ions from the [M + H](+) and [M + Na](+) ions of both OTA and OTB were monitored in the multiple reaction monitoring mode. Three quantitative approaches, standard addition method, internal standard method (using ochratoxin B as an internal standard) and external standard method, were compared in the analysis of human blood plasma. Results from the mass spectrometric method were comparable to those from a conventional LC/fluorescence method. The LC/MS/MS method was also applied to the analysis of contaminated coffee samples.  相似文献   

12.
Electrospray ionization mass spectrometry (ESI-MS) is now routinely used for the detection of cyclodextrin noncovalent complexes, complementing previously established methods. Host-guest complexes formed in solution are also stable for characterization by ESI in the gas phase. This paper reports the first investigations to characterize the stability of three inclusion complexes between beta-cyclodextrin (beta-CD) and three model "guest" molecules, by determining the cyclodextrin compound complex stability constant (K(st)) with the use of mass spectrometric studies. The relative signal intensity of the complexes were monitored in the positive ion mode by mixing each "guest" molecule with an up to 50-fold molar excess of betaCD. A novel linear equation, similar to Benesi-Hildebrand, was derived allowing the determination of K(st) for 1:1 stoichiometry in all complexes. These values were compared with the K(st) obtained by spectrophotometric experiments and they were evaluated to be slightly different, indicating the validity of the described method.  相似文献   

13.
Mass spectrometry (MS) and ion mobility with electrospray ionization (ESI) have the capability to measure and detect large noncovalent protein-ligand and protein-protein complexes. Using an ion mobility method of gas-phase electrophoretic mobility molecular analysis (GEMMA), protein particles representing a range of sizes can be separated by their electrophoretic mobility in air. Highly charged particles produced from a protein complex solution using electrospray can be manipulated to produce singly charged ions, which can be separated and quantified by their electrophoretic mobility. Results from ESI-GEMMA analysis from our laboratory and others were compared with other experimental and theoretically determined parameters, such as molecular mass and cryoelectron microscopy and X-ray crystal structure dimensions. There is a strong correlation between the electrophoretic mobility diameter determined from GEMMA analysis and the molecular mass for protein complexes up to 12 MDa, including the 93 kDa enolase dimer, the 480 kDa ferritin 24-mer complex, the 4.6 MDa cowpea chlorotic mottle virus (CCMV), and the 9 MDa MVP-vault assembly. ESI-GEMMA is used to differentiate a number of similarly sized vault complexes that are composed of different N-terminal protein tags on the MVP subunit. The average effective density of the proteins and protein complexes studied was 0.6 g/cm(3). Moreover, there is evidence that proteins and protein complexes collapse or become more compact in the gas phase in the absence of water.  相似文献   

14.
Based on analysis by liquid chromatography/electrospray ionisation mass spectrometry, we have developed a new method for fast and sensitive fingerprinting of gliadins and glutenins in wheat flour. Using this procedure the two protein fractions from seven durum wheat varieties have been analysed by high resolution high performance liquid chromatographic separation coupled to accurate determination of molecular mass. In this way, the molecular mass of the single components from both gliadin and glutenin fractions were measured and more than forty components were detected for each fraction indicating a high heterogeneity. Although the chromatographic profiles were similar, the molecular masses of protein components with similar retention times among the varieties were often different. The difference ranged from a few mass units corresponding to single amino acid substitution(s) up to thousands implying peptide deletion or insertion along the protein chain. Two components representing about a half of the gliadin fraction, e.g. gamma(2)- and gamma(3)-gliadin, were identified through the N-terminal sequence and molecular mass determination. We suggest the use of the high level and the molecular mass of these gliadin components as markers to detect traces of wheat in gluten-free food preparations for celiac patients.  相似文献   

15.
Herein we report a novel calibration routine for use in positive ion mode electrospray ionization mass spectrometry (ESI-MS). Monoisotopic masses were calculated for a series of water clusters and used as calibration reference files (available at http://www.hbcg.utmb.edu/xray). The water cluster series contains singly charged peaks every 18 Da, which allows calibration curves to be precisely defined over a broad mass-to-charge ratio range. Water clusters, induced by a combination of high flow rate and high cone voltage, were used to accurately calibrate a quadrupole mass spectrometer from 100 to 1900 m/z. Calibration curves thus generated have many more data points and greatly reduced standard deviations compared to those obtained from myoglobin, sodium iodide, cesium iodide, or poly(ethylene glycol) based calibration standards. This calibration routine reduces the error in protein mass measurements by a factor of 3, from ±0.01% to ±0.0035% at the 95% confidence limit. The implications of this increased mass accuracy and wider calibrated mass-to-charge ratio scale for the study of protein sequence, structure, and folding by ESI-MS are discussed.  相似文献   

16.
The electrospray ionisation ion trap tandem mass spectrometry (ESI-MS(n)) of selected antidepressant drugs, i.e., citalopram, fluoxetine, mirtazapine, paroxetine, sertraline, and venlafaxine, has been investigated. Sequential product ion fragmentation experiments (MS(n)) have been performed in order to elucidate the degradation pathways for the [M+H](+) ions and their predominant product ions. These MS(n) experiments show certain characteristic fragmentations in that functional groups are generally cleaved from the ring systems as molecules such as H(2)O, amines and phenols. When an aromatic entity is present in a drug molecule together with a nitrogen-containing saturated ring structure as with mirtazapine, fragmentation initially occurs at the latter ring with the former being predictably resistant to fragmentation. Also, when an amine-containing drug molecule such as fluoxetine also contains a functional group, which liberates a phenol with a significantly lower DeltaH(f) (0) value than that of the corresponding amine, the phenol is preferentially liberated. The structures of product ions proposed for ESI-MS(n) can be supported by electrospray ionisation quadrupole-time-of-flight tandem mass spectrometry (ESI-QToF-MS/MS). These molecules can be identified and determined in mixtures at low ng/mL concentrations by the application of high-performance liquid chromatography/electrospray ionisation tandem mass spectrometry (HPLC/ESI-MS(2)), which can also be used for their analysis in hair samples.  相似文献   

17.
We describe an approach for the determination of binding constants for protein-ligand complexes with electrospray ionization mass spectrometry, based on the observation of unbound ligands competing for binding to a protein target. For the first time, dissociation constants lower than picomolar could be determined with good accuracy by electrospray ionization mass spectrometry. The presented methodology relies only on the determination of signal intensity ratios for free ligands in the low mass region. Therefore, all the advantages of measuring low masses with mass spectrometry, such as high resolution are preserved. By using a reference ligand with known binding affinity, the affinity of a second ligand can be determined. Since no noncovalently bound species are observed, assumptions about response factors are not necessary. The method is validated with ligands binding to avidin and applied to ligands binding to p38 mitogen-activated protein kinase.  相似文献   

18.
Charge detection mass spectrometry (CD-MS) has been used to determine the mass of double-stranded, circular DNA and single-stranded, circular DNA in the range of 2500 to 8000 base pairs (1.5–5.0 MDa). Simultaneous measurement of the charge and velocity of an electrostatically accelerated ion allows a mass determination of the ion, with instrument calibration determined independently of samples. Positive ion mass spectra of electrosprayed commercial DNA samples supplied in tris(hydroxymethyl)ethylenediaminetetraacetic acid buffer, diluted in 50 vol. % acetonitrile, were obtained without cleanup of the sample. A CD mass spectrum constructed from 3000 ion measurements takes 10 min to acquire and yields the DNA molecular mass directly (mass resolution = 6). The data collected represent progress toward a more automatable alternative to sizing of DNA by gel electrophoresis. In addition to the mass spectra, CD-MS generates charge versus mass plots, which provide another means to investigate the creation and fate of large electrospray ions.  相似文献   

19.
The acid-induced denaturation of cellular retinol-binding proteins types I and II (CRBP I and II), in the presence and in the absence of the ligand, was studied by electrospray ionization mass spectrometry (ESI-MS) in the pH range 6.9-2.4. To avoid artifacts generated by the ESI process, suitable interface parameters were selected. Different charge-state distributions were observed in the ESI-MS spectra, reflecting the pH-dependent equilibria among protein conformations in solution. In the absence of retinol, CRBP II appeared to be more resistant than CRBP I to acid denaturation. The bound ligand stabilized both carriers, with a markedly higher effect on CRBP I. Retinol release from the ligand-bound carriers and protein denaturation occurred concomitantly. This finding suggests that the lowering of pH, reported to occur in proximity to a biomembrane, might contribute to the conformational transitions required to promote dissociation of the otherwise very stable retinal-carrier complexes and thus permit targeted delivery of vitamin A to the enzymes involved in its metabolism.  相似文献   

20.
Oxysterols are oxygenated derivatives of cholesterol. They are intermediates in cholesterol excretion pathways and may also be regarded as transport forms of cholesterol. The introduction of additional hydroxyl groups to the cholesterol skeleton facilitates the flux of oxysterols across the blood brain barrier, and oxysterols have been implicated in mediating a number of cholesterol-induced metabolic effects. Oxysterols are difficult to analyze by atmospheric pressure ionization mass spectrometry on account of the absence of basic or acidic functional groups in their structures. In this communication, we report a method for the derivatization and analysis of oxysterols by electrospray mass spectrometry. Oxysterols with a 3beta-hydroxy-Delta5 structure were converted by cholesterol oxidase to 3-oxo-Delta4 steroids and then derivatized with the Girard P reagent to give Girard P hydrazones, which were subsequently analyzed by tandem mass spectrometry. The improvement in sensitivity for the analysis of 25-hydroxycholesterol upon oxidation and derivatization was over 1000.  相似文献   