首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cyclosporine, tacrolimus, sirolimus, and everolimus are commonly used immunosuppressants following organ transplantation. Their monitoring is used to determine the optimal dose for therapeutic effectiveness and minimize toxicity. High-performance liquid chromatographic–tandem mass spectrometry with positive electrospray ionization and multiple reaction monitoring mode was validated for the determination of cyclosporine A, tacrolimus, sirolimus, and everolimus in whole blood. A C18 analytical column was employed with a gradient elution of pH 4.0 aqueous 10?mmol/L ammonium acetate and acetonitrile. For the pretreatment of whole blood, simple protein precipitation was used with methanol:zinc sulfate. The calibration curves were linear from 20.0 to 1000?ng/mL for cyclosporine A, 1.0 to 50?ng/mL for tacrolimus and sirolimus, and 1.0 to 30?ng/mL for everolimus. The intra-assay precision and inter-assay precision were less than 15%. The method provides reliable and reproducible results according to the linearity, precision, accuracy, recovery, and matrix effects. The method has been introduced to routine clinical practice in Slovakia for the determination of immunosuppressants in patients after kidney transplantation.  相似文献   

2.
To investigate the consistency and bioequivalence of tacrolimus ointment reference and trial formulation, the tacrolimus concentrations in blood and skin were determined by HPLC‐ESI‐MS/MS following topical application of two kinds of ointment in porcine skin in a parallel, cross‐over trial. The plasma protein of blood was precipitated by acetonitrile and the tacrolimus in skin was extracted by acetonitrile before HPLC‐ESI‐MS/MS analysis. The internal calibration method (diazepam was the internal standard) was used for quantification analysis (R2 > 0.9999), with linear range from 0.05 to 5 ng/mL for blood samples and from 1 to 200 ng/mL for skin samples. The limits of detection for the porcine blood and skin were 0.005 and 0.5 ng/mL, respectively. The average recoveries for the porcine blood and skin spiked at three levels were 97.56–109.53 and 96.48–103.57%, respectively. The precision expressed in RSDs was from 3.43 to 10.83% for porcine blood and from 3.10 to 8.69% for porcine skin. For the same pig, the tacrolimus concentrations and variation with time of the two kinds of ointment in porcine skin were similar, although variation occurred with different individuals. These results showed that the release and penetration of tacrolimus from the reference and trial formulation are similar. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
An accurate, simple, reproducible, and sensitive liquid chromatographic method was developed and validated for the determination of omeprazole in powder for injection and in pellets. The analyses were performed at room temperature on a reversed-phase C18 column of 250 x 4.6 mm id, 5 microm particle size. The mobile phase, composed of methanol-water (90 + 10, v/v), was pumped at a constant flow rate of 1.5 mL/min. Detection was performed on a UV detector at 301 nm. The method was validated in terms of linearity, precision, accuracy, and ruggedness. The response was linear in the range 32-48 microg/mL (r2 = 0.9976). The relative standard deviation values for intra- and interday precision studies were 1.22 and 1.56% for injectable and 2.13 and 2.45% for pellets, respectively. Recoveries ranged between 95.81 and 100.48%.  相似文献   

4.
A sensitive and selective method for determining the residual monoethanolamine in a developmental drug substance is developed and validated. Marfey's reagent, which is commonly used for the chiral analysis of amino acids, is reacted with the primary amine group of monoethanolamine and then analyzed by high-performance liquid chromatography-UV at 340 nm. Quantitation is performed by a standard addition method by preparing drug substance samples with added monoethanolamine ranging from 0.25-1.0 microg/mL (equivalent to 12.5-50 ppm with respect to the drug substance). The method performance is evaluated for linearity, specificity, detection and quantitation limits, accuracy, precision, and sample stability. The method is linear from 0.25-1.0 microg/mL with a coefficient of determination (r(2)) > 0.95. The accuracy and precision obtained is 105.5 +/- 4.8% (n = 3). The limits of detection and quantitation are 0.03 and 0.10 microg/mL, respectively. Instrument precision (% relative standard deviation of six injections of a derivatized 0.5 microg/mL monoethanolamine solution on two separate days) is >/= 2.0%. This method is suitable for the determination of monoethanolamine at the 25 ppm level in drug substance.  相似文献   

5.
Tacrolimus has a narrow therapeutic index and large individual differences in pharmacokinetics. The distribution of tacrolimus in ascitic fluid and its influence on whole-blood tacrolimus were unclear. In this study, a sensitive ultra-performance liquid chromatography-tandem mass spectrometry method was established and validated for the quantification of tacrolimus in the ascitic fluid of liver transplant recipients. Chromatographic separation was achieved on an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl column (2.1 × 100 mm, 3.5 μm). Mass spectrometry was performed in multiple reaction monitoring conditions of transitions m/z 821.4→768.5 for tacrolimus. The concentrations of tacrolimus in the ascitic fluid range from 0.2 to 3.0 ng/mL, accounting for 1.19–31.87% of whole-blood tacrolimus concentrations. A linear mixed model showed a statistically significant positive correlation between the steady-state trough blood concentration of tacrolimus and the corresponding amount of tacrolimus excreted in the ascitic fluid for 24 consecutive hours, especially after normalization by daily dose per unit body weight. These data suggested that the distribution of tacrolimus in the ascitic fluid has great individual differences. The whole-blood tacrolimus concentration, dose per unit body weight, and other confounding factors may contribute to the excretion of tacrolimus in ascitic fluid, but the influence of tacrolimus excretion in drained ascitic fluid on the whole-blood tacrolimus concentration is negligible.  相似文献   

6.
A simple and reliable high-performance liquid chromatographic (HPLC) method has been developed for the determination of nodakenin in rat plasma. The concentration of nodakenin was determined in plasma samples after deproteinization with methanol using hesperidin as internal standard. HPLC analysis was performed on a Diamonsil C(18) analytical column using acetonitrile-water (25:75, v/v) as the mobile phase and a UV detection at 330 nm. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day variation). The extraction recoveries were 91.3 ± 10, 87.8 ± 4.8 and 92.6 ± 5.1 at concentrations of 0.500, 5.00 and 40.0 μg/mL, respectively. The standard curve for nodakenin was linear (r(2) ≥ 0.99) over the concentration range 0.250-50.0 μg/mL with a lower limit of quantification of 0.250 μg/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were not higher than 12% and the accuracy (relative error, RE) was within ± 5.8% at three quality control levels. The validated method was successfully applied for the evaluation of the pharmacokinetics of nodakenin in rats after oral administration of Rhizoma et Radix Notopterygii decoction and nodakenin solution.  相似文献   

7.
A novel, sensitive and specific method for the quantitative determination of diclazuril in animal plasma using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with negative ion detection is presented. Extraction of the samples was performed with a rapid deproteinization step using acetonitrile. Chromatography of diclazuril and the internal standard was achieved on a Nucleosil ODS 5-microm column, using a gradient elution with 0.01 M ammonium acetate and acetonitrile. To obtain the highest sensitivity and specificity possible, the mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1-100 ng/mL and 100-2000 ng/mL showed good linear correlation (r >or= 0.9991, goodness-of-fit coefficient 相似文献   

8.
An LC–MS/MS method was developed and validated for bioanalysis of clofazimine in human dried blood spot (DBS) samples in support of a clinical study on multidrug‐resistant tuberculosis in developing countries. The validated assay dynamic range was from 10.0 to 2000 ng/mL using a 1/8 inch DBS punch. The accuracy and precision of the assay were ±11.0% (bias) and ≤13.5% (CV) for the LLOQs (10.0 ng/mL) and ±15% (bias) and ≤15% (CV) for all other QC levels. The assay was proved to be free from the possible impact owing to spot size and storage temperature (e.g. at 60°C, ≤ − 60°C). The validated assay is well suited for the intended clinical study where conventional pharmacokinetic sample collection is not feasible.  相似文献   

9.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to determine the concentrations of adefovir [9-(2-phosphonylmethoxyethyl)adenine, PMEA] in human plasma. After one-step protein precipitation of plasma samples by methanol, adefovir was analyzed by LC/MS/MS using positive electrospray ionization. Chromatography was performed on a C18 column. The extraction recoveries of adefovir were found to be 85.1-89.3%. Adefovir was stable under routine laboratory conditions. A minimal matrix effect resulting in a slight ionization enhancement of adefovir (<10.9%) was observed, which did not markedly affect the behavior of the calibrations curves and accuracy and precision data. The method had a chromatographic run time of 7.8 min and a linear calibration curve over the concentration range 1.5-90 ng/mL for adefovir. The lower limit of quantification of the method was 1.5 ng/mL. The intra- and inter-day precision was less than 8.4%. These results indicated that this LC/MS/MS method has high selectivity and efficiency, and acceptable accuracy, precision and sensitivity. The validated LC/MS/MS method has been successfully used in a pharmacokinetic study in healthy volunteers treated with oral adefovir dipivoxil at 10 and 20 mg.  相似文献   

10.
A new, simple, sensitive, rapid, and accurate isocratic RP-HPLC method was developed and validated for simultaneous analysis of the principal antioxidants of Nigella sativa, i.e., thymoquinone (TQ), carvacrol (CR), and its isomer thymol (THY), in different phytopharmaceuticals. The mobile phase was water-methanol (40 + 60, v/v) at a flow rate of 1.5 mL/min. Quantification was achieved with UV detection at 254 nm, based on peak area. The method was validated for linearity, accuracy, precision, selectivity, and robustness. The proposed method is stability-indicating for determination of TQ in the presence of its degradants. The LOD and LOQ (microg/mL) were, respectively, 0.006 and 0.021 for TQ, 0.002 and 0.006 for CR, and 0.027 and 0.090 for THY. The mean recoveries measured at three concentrations were higher than 99%, with RSD <2%. This analytical method is suitable for quality control of the marker substances in this widely used natural protective and curative remedy.  相似文献   

11.
A rapid and simple high-performance liquid chromatographic method for the analysis of 1,3-dihydroxy-2-methylxanthone (DHMXAN) in biodegradable poly(D,L-lactide-co-glycolide) (PLGA) nanosphere and nanocapsule formulations is developed and validated. The method does not require any complex sample extraction procedure. Chromatographic separation is made with a reversed-phase C18 column, using methanol-water (90:10, v/v) containing 1% (v/v) acetic acid as a mobile phase at a flow rate of 1 mL/min. Identification is made by UV detection at 237 nm. The isocratic system operates at ambient temperature and requires 7.5 min of chromatographic time. The developed method is statistically validated according to ICH guidelines and USP 29 for its specificity, linearity, accuracy, and precision. The assay method proposed in this study is specific for DHMXAN in the presence of nanosphere and nanocapsule excipients. Diode-array analyses confirm the purity of DHMXAN peak in stress conditions (> 99.0%). The method is shown to be linear (r > or = 0.999) over the concentration range of 0.25-3.0 microg/mL. Recovery ranges from 99.0% to 102.7% (RSD: 1.49%) and from 98.3% to 101.6% (RSD: 1.07%) for nanospheres and nanocapsules, respectively. Repeatability (intra-assay precision) and intermediate precision is acceptable with RSD values ranging from 0.6% to 1.9% and from 0.3% to 2.0%, respectively. The method is shown to be suitable for the evaluation of DHMXAN content entrapped in PLGA nanoparticles.  相似文献   

12.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated to simultaneously determine mifepristone and monodemethyl-mifepristone in human plasma using levonorgestrel as the internal standard (IS). After solid-phase extraction of the plasma samples, mifepristone, monodemethyl-mifepristone and the IS were subjected to LC-MS/MS analysis using electro-spray ionization (ESI) in the multiple reaction monitoring (MRM) mode. Chromatographic separation was performed on an XTERRA MS C(18) column (150 x 2.1 mm i.d., 5 microm). The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration ranges of 5-2000 ng/mL for mifepristone and monodemethyl-mifepristone. The recoveries of the method were found to be 94.5-103.7% for mifepristone and 70.7-77.3% for monodemethyl-mifepristone. The method had a lower limit of quantification (LLOQ) of 5.0 ng/mL and a lower limit of detection (LOD) of 1.0 ng/mL for both mifepristone and monodemethyl-mifepristone. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 10, 100 and 1000 ng/mL. These results indicate that the method was efficient with a short run time (4.5 min) and acceptable accuracy, precision and sensitivity. The validated LC-MS/MS method was successfully used in a pharmacokinetic study in healthy female volunteers after oral administration of 25 mg mifepristone tablet.  相似文献   

13.
Methotrexate(MTX) is an antineoplastic therapeutic medicine as antimetabolite of folic acid. In this paper, a sensitive and rapid ultra-performance liquid chromatographic(UPLC) method was developed and validated for the separation and determination of impurities in MTX drug substances. The UPLC method was accomplished on an Agilent Zorbax Extend C-18(50 mm 4.6 mm, 1.8 mm) with a gradient elution system composed of sodium dihydrogen phosphate in water(20 mmol/L, pH 3.0) and acetonitrile. The flow rate was 2.2 mL/min. The method was validated. The calibration curves displayed good linearity(r 0.999) within the tested concentration ranges. The limit of detection(LOD) and limit of quantification(LOQ) of the six analytes were all less than 0.774 mg/mL and 1.03 mg/mL. The relative standard deviation(RSD) for intra- and inter-day precision of the six analytes was less than 9.8%, including at the LOQ. The average recovery ranged from 95.2% to 103% except at the LOQ, where recovery ranged from 82.7% to 117%. The validated method was successfully used to determine the relative abundance of six impurities in the MTX drug substances.  相似文献   

14.
A simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for determining rosuvastatin in human plasma, a new synthetic hydroxymethylglutaryl-coenzyme A reductase inhibitor. The analyte and internal standard (IS; cilostazol) were extracted by simple one-step liquid/liquid extraction with ether. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The chromatographic separation was performed on an Atlantis C18 column (2.1 mm x 150 mm, 5.0 microm) with a mobile phase consisting of 0.2% formic acid/methanol (30:70, v/v) at a flow rate of 0.20 mL/min. The analyses were carried out by multiple reaction monitoring (MRM) using the precursor-to-product combinations of m/z 482 --> 258 and m/z 370 --> 288. The areas of peaks from the analyte and the IS were used for quantification of rosuvastatin. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification (LLOQ) was 0.2 ng/mL and the assay exhibited a linear range of 0.2-50.0 ng/mL and gave a correlation coefficient (r) of 0.9991 or better. Quality control samples (0.4, 8, 25 and 40 ng/mL) in six replicates from three different runs of analysis demonstrated an intra-assay precision (RSD) 7.97-15.94%, an inter-assay precision 3.19-15.27%, and an overall accuracy (relative error) of < 3.7%. The method can be applied to pharmacokinetic or bioequivalence studies of rosuvastatin.  相似文献   

15.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

16.
A highly sensitive high-performance liquid chromatographic quantification method with fluorescence detection was developed and validated for the determination of doxazosin in human plasma. The developed method employed one-step extraction of doxazosin from plasma matrix with ethyl acetate using propranolol as an internal standard. Chromatographic separation was obtained within 8.0 min using a reverse-phase Capcell-Pak C(18) column (150 x 4.6 mm i.d., 5 microm) and the mobile phase consisted of methanol-water containing 10 mM perchloric acid and 1.8 mM sodium heptane sulfonic acid (50:50, v/v) and was set at a flow rate of 1.5 mL/min. The calibration curve constructed was linear in the range of 0.3-50.0 ng/mL. The proposed method achieved a lower limit of quantification of 0.3 ng/mL, better than the reported HPLC methods. Average recoveries of doxazosin and the internal standard from human plasma matrix were 87.0 and 85.9%, respectively. The present method was validated by evaluating the precision and accuracy for inter- and intraday variation in the concentration range 0.3-50 ng/mL. The precision values expressed as relative standard deviations in the inter- and intraday validation were 1.17-6.29 and 0.84-5.94%, respectively. This method was successfully applied to the bioequivalence study of two doxazosin controlled release tablets in healthy, male human subjects.  相似文献   

17.
A simple, precise, and accurate isocratic RP-HPLC method was developed and validated for determination of eprosartan in bulk drug and tablets. Isocratic RP-HPLC separation was achieved on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using the mobile phase 0.5% formic acid-methanol-acetonitrile (80 + 25 + 20, v/v/v, pH 2.80) at a flow rate of 1.0 mL/min. The retention time of eprosartan was 7.64 +/- 0.05 min. The detection was performed at 232 nm. The method was validated for linearity, precision, accuracy, robustness, solution stability, and specificity. The method was linear in the concentration range of 10-400 microg/mL with a correlation coefficient of 0.9999. The repeatability for six samples was 0.253% RSD; the intraday and interday precision were 0.21-0.57 and 0.33-0.71% RSD, respectively. The accuracy (recovery) was found to be in the range of 99.86-100.92%. The drug was subjected to the stress conditions hydrolysis, oxidation, photolysis, and heat. Degradation products produced as a result of the stress conditions did not interfere with detection of eprosartan; therefore, the proposed method can be considered stability-indicating.  相似文献   

18.
An ultraviolet spectrophotometric method was validated for total flavonoid quantitation, as rutin equivalents, present in the Trichilia catigua Adr. Juss (Meliaceae) and Ptychopetalum olacoides Bentham (Olacaceae) commercial extract. Parameters as linearity, interval (range), specificity, estimated limit of detection (LOD, microg/mL), estimated limit of quantitation (LOQ, microg/mL), recovery (R, %), precision or relative standard deviation (RSD, %), and accuracy (E, %) were established. The analytical method was validated according to the experimental results: correlation coefficient (r = 0.9997); interval (RSD = 0.15-0.47%; E = 98.98-101.24%); specificity to total flavonoids quantitation, as rutin equivalents, at wavelength 361.0 nm; LOD = 0.09 microg/mL and LOQ = 0.27 microg/mL; R = 99.36-102.14%; adequate intra- and interrun precision (0.30-0.49% and 0.31-0.81%), and intra- and interrun accuracy (100.60-102.38% and 98.58-100.38%).  相似文献   

19.
A sensitive and specific method was developed and validated for the determination of mitiglinide in human plasma using liquid chromatographic separation with electrospray ionization tandem mass spectrometric detection. Acidified plasma samples were extracted with ethyl acetate. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C(18) column with a mobile phase of methanol-10 mm ammonium acetate solution at a flow rate of 0.3 mL/min. Analytes were detected with an Agilent 6410 Triple qudrupole mass spectrometer equipped with an electrospray ionization source in positive multiple reaction monitoring mode: m/z 316.2 (precursor ion) to 298.2 (product ion) for mitiglinide and m/z 318.2 (precursor ion) to 120.2 (product ion) for the internal standard. This method was validated over a linear range of 0.5-4000 ng/mL for mitiglinide in human plasma. The lower limit of quantification (LLOQ) was 0.5 ng/mL, while a relative standard deviation (RSD) was less than 3.9%. The intra- and inter-run precision (as RSD, %) obtained from three validation runs were all less than 15%. The validated method was successfully used to analyze human plasma samples for application in pharmacokinetic studies.  相似文献   

20.
A fast and sensitive HPLC-MS method for the quantification of apovincaminic acid, a vinpocetine metabolite, in human plasma has been developed and validated. After protein precipitation with methanol, 10 mL of supernatant was injected at 45 degrees C onto a Zorbax SB-C18 column. Elution was performed in less than three minutes with water containing 0.2% formic acid and acetonitrile (80:20) at 0.75 mL/min. A linearity domain between 4 and 240 ng/mL and a limit of quantification of 4 ng/mL apovincaminic acid were established by monitoring the signal corresponding to m/z = 323. Accuracy and precision were less than 5.2% for within-run assay and 10% for between-run assay. The method was successfully applied in a bioequivalence study of two pharmaceutical products containing 5 mg vinpocetine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号