首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Speech-understanding difficulties observed in elderly hearing-impaired listeners are predominantly errors in the recognition of consonants, particularly within consonants that share the same manner of articulation. Spectral shape is an important acoustic cue that serves to distinguish such consonants. The present study examined whether individual differences in speech understanding among elderly hearing-impaired listeners could be explained by individual differences in spectral-shape discrimination ability. This study included a group of 20 elderly hearing-impaired listeners, as well as a group of young normal-hearing adults for comparison purposes. All subjects were tested on speech-identification tasks, with natural and computer-synthesized speech stimuli, and on a series of spectral-shape discrimination tasks. As expected, the young normal-hearing adults performed better than the elderly listeners on many of the identification tasks and on all but two discrimination tasks. Regression analyses of the data from the elderly listeners revealed moderate predictive relationships between some of the spectral-shape discrimination thresholds and speech-identification performance. The results indicated that when all stimuli were at least minimally audible, some of the individual differences in the identification of natural and synthetic speech tokens by elderly hearing-impaired listeners were associated with corresponding differences in their spectral-shape discrimination abilities for similar sounds.  相似文献   

2.
The ability to discriminate between sounds with different spectral shapes was evaluated for normal-hearing and hearing-impaired listeners. Listeners detected a 920-Hz tone added in phase to a single component of a standard consisting of the sum of five tones spaced equally on a logarithmic frequency scale ranging from 200 to 4200 Hz. An overall level randomization of 10 dB was either present or absent. In one subset of conditions, the no-perturbation conditions, the standard stimulus was the sum of equal-amplitude tones. In the perturbation conditions, the amplitudes of the components within a stimulus were randomly altered on every presentation. For both perturbation and no-perturbation conditions, thresholds for the detection of the 920-Hz tone were measured to compare sensitivity to changes in spectral shape between normal-hearing and hearing-impaired listeners. To assess whether hearing-impaired listeners relied on different regions of the spectrum to discriminate between sounds, spectral weights were estimated from the perturbed standards by correlating the listener's responses with the level differences per component across two intervals of a two-alternative forced-choice task. Results showed that hearing-impaired and normal-hearing listeners had similar sensitivity to changes in spectral shape. On average, across-frequency correlation functions also were similar for both groups of listeners, suggesting that as long as all components are audible and well separated in frequency, hearing-impaired listeners can use information across frequency as well as normal-hearing listeners. Analysis of the individual data revealed, however, that normal-hearing listeners may be better able to adopt optimal weighting schemes. This conclusion is only tentative, as differences in internal noise may need to be considered to interpret the results obtained from weighting studies between normal-hearing and hearing-impaired listeners.  相似文献   

3.
Thresholds of ongoing interaural time difference (ITD) were obtained from normal-hearing and hearing-impaired listeners who had high-frequency, sensorineural hearing loss. Several stimuli (a 500-Hz sinusoid, a narrow-band noise centered at 500 Hz, a sinusoidally amplitude-modulated 4000-Hz tone, and a narrow-band noise centered at 4000 Hz) and two criteria [equal sound-pressure level (Eq SPL) and equal sensation level (Eq SL)] for determining the level of stimuli presented to each listener were employed. The ITD thresholds and slopes of the psychometric functions were elevated for hearing-impaired listeners for the two high-frequency stimuli in comparison to: the listener's own low-frequency thresholds; and data obtained from normal-hearing listeners for stimuli presented with Eq SPL interaurally. The two groups of listeners required similar ITDs to reach threshold when stimuli were presented at Eq SLs to each ear. For low-frequency stimuli, the ITD thresholds of the hearing-impaired listener were generally slightly greater than those obtained from the normal-hearing listeners. Whether these stimuli were presented at either Eq SPL or Eq SL did not differentially affect the ITD thresholds across groups.  相似文献   

4.
Profile-analysis thresholds were measured in the presence and absence of overall level variation at different stimulus levels to determine whether nonlinear changes in the shape of the edges of excitation pattern peaks contribute to poorer spectral-shape sensitivity observed under roving levels. Roving levels decreased sensitivity for stimuli having few components separated widely in frequency to a greater extent than for stimuli having more densely spaced components. The stimulus level did not influence sensitivity when overall level variation was absent, suggesting that listeners rely on peaks in the excitation patterns and not the edges of the peaks (as would have been predicted by the near miss to Weber's law). Because the edges of the peaks were not used in the absence of roving levels, it follows that the larger rove effects for sparse stimuli were not likely due to excitation pattern inconstancy.  相似文献   

5.
A conditional-on-a-single-stimulus (COSS) analysis procedure [B. G. Berg, J. Acoust. Soc. Am. 86, 1743-1746 (1989)] was used to estimate how well normal-hearing and hearing-impaired listeners selectively attend to individual spectral components of a broadband signal in a level discrimination task. On each trial, two multitone complexes consisting of six octave frequencies from 250 to 8000 Hz were presented to listeners. The levels of the individual tones were chosen independently and at random on each presentation. The target tone was selected, within a block of trials, as the 250-, 1000-, or 4000-Hz component. On each trial, listeners were asked to indicate which of the two complex sounds contained the higher level target. As a group, normal-hearing listeners exhibited greater selectivity than hearing-impaired listeners to the 250-Hz target, while hearing-impaired listeners showed greater selectivity than normal-hearing listeners to the 4000-Hz target, which is in the region of their hearing loss. Both groups of listeners displayed large variability in their ability to selectively weight the 1000-Hz target. Trial-by-trial analysis showed a decrease in weighting efficiency with increasing frequency for normal-hearing listeners, but a relatively constant weighting efficiency across frequency for hearing-impaired listeners. Interestingly, hearing-impaired listeners selectively weighted the 4000-Hz target, which was in the region of their hearing loss, more efficiently than did the normal-hearing listeners.  相似文献   

6.
The ability of normally hearing and hearing-impaired subjects to use temporal fine structure information in complex tones was measured. Subjects were required to discriminate a harmonic complex tone from a tone in which all components were shifted upwards by the same amount in Hz, in a three-alternative, forced-choice task. The tones either contained five equal-amplitude components (non-shaped stimuli) or contained many components, but were passed through a fixed bandpass filter to reduce excitation pattern changes (shaped stimuli). Components were centered at nominal harmonic numbers (N) 7, 11, and 18. For the shaped stimuli, hearing-impaired subjects performed much more poorly than normally hearing subjects, with most of the former scoring no better than chance when N=11 or 18, suggesting that they could not access the temporal fine structure information. Performance for the hearing-impaired subjects was significantly improved for the non-shaped stimuli, presumably because they could benefit from spectral cues. It is proposed that normal-hearing subjects can use temporal fine structure information provided the spacing between fine structure peaks is not too small relative to the envelope period, but subjects with moderate cochlear hearing loss make little use of temporal fine structure information for unresolved components.  相似文献   

7.
To determine the minimum difference in amplitude between spectral peaks and troughs sufficient for vowel identification by normal-hearing and hearing-impaired listeners, four vowel-like complex sounds were created by summing the first 30 harmonics of a 100-Hz tone. The amplitudes of all harmonics were equal, except for two consecutive harmonics located at each of three "formant" locations. The amplitudes of these harmonics were equal and ranged from 1-8 dB more than the remaining components. Normal-hearing listeners achieved greater than 75% accuracy when peak-to-trough differences were 1-2 dB. Normal-hearing listeners who were tested in a noise background sufficient to raise their thresholds to the level of a flat, moderate hearing loss needed a 4-dB difference for identification. Listeners with a moderate, flat hearing loss required a 6- to 7-dB difference for identification. The results suggest, for normal-hearing listeners, that the peak-to-trough amplitude difference required for identification of this set of vowels is very near the threshold for detection of a change in the amplitude spectrum of a complex signal. Hearing-impaired listeners may have difficulty using closely spaced formants for vowel identification due to abnormal smoothing of the internal representation of the spectrum by broadened auditory filters.  相似文献   

8.
Temporal processing ability in the hearing impaired was investigated in a 2IFC gap-detection paradigm. The stimuli were digitally constructed 50-Hz-wide bands of noise centered at 250, 500, and 1000 Hz. On each trial, two 400-ms noise samples were paired, shaped at onset and offset, filtered, and presented in the quiet with and without a temporal gap. A modified up-down procedure with trial-by-trial feedback was used to establish threshold of detection of the gap. Approximately 4 h of practice preceded data collection; final estimate of threshold was the average of six listening blocks. There were 10 listeners, 19-25 years old. Five had normal hearing; five had a moderate congenital sensorineural hearing loss with relatively flat audiometric configuration. Near threshold (5 dB SL), all listeners performed similarly. At 15 and 25 dB SL, the normal-hearing group performed better than the hearing-impaired group. At 78 dB SPL, equal to the average intensity of the 5-dB SL condition for the hearing impaired, the normal-hearing group continued to improve and demonstrated a frequency effect not seen in the other conditions. Substantial individual differences were found in both groups, though intralistener variability was as small as expected for these narrow-bandwidth signals.  相似文献   

9.
The present study assesses the ability of four listeners with high-frequency, bilateral symmetrical sensorineural hearing loss to localize and detect a broadband click train in the frontal-horizontal plane, in quiet and in the presence of a white noise. The speaker array and stimuli are identical to those described by Lorenzi et al. (in press). The results show that: (1) localization performance is only slightly poorer in hearing-impaired listeners than in normal-hearing listeners when noise is at 0 deg azimuth, (2) localization performance begins to decrease at higher signal-to-noise ratios for hearing-impaired listeners than for normal-hearing listeners when noise is at +/- 90 deg azimuth, and (3) the performance of hearing-impaired listeners is less consistent when noise is at +/- 90 deg azimuth than at 0 deg azimuth. The effects of a high-frequency hearing loss were also studied by measuring the ability of normal-hearing listeners to localize the low-pass filtered version of the clicks. The data reproduce the effects of noise on three out of the four hearing-impaired listeners when noise is at 0 deg azimuth. They reproduce the effects of noise on only two out of the four hearing-impaired listeners when noise is at +/- 90 deg azimuth. The additional effects of a low-frequency hearing loss were investigated by attenuating the low-pass filtered clicks and the noise by 20 dB. The results show that attenuation does not strongly affect localization accuracy for normal-hearing listeners. Measurements of the clicks' detectability indicate that the hearing-impaired listeners who show the poorest localization accuracy also show the poorest ability to detect the clicks. The inaudibility of high frequencies, "distortions," and reduced detectability of the signal are assumed to have caused the poorer-than-normal localization accuracy for hearing-impaired listeners.  相似文献   

10.
The ability to discriminate between sounds with different spectral shapes was evaluated for normal-hearing and hearing-impaired listeners. Listeners discriminated between a standard stimulus and a signal stimulus in which half of the standard components were decreased in level and half were increased in level. In one condition, the standard stimulus was the sum of six equal-amplitude tones (equal-SPL), and in another the standard stimulus was the sum of six tones at equal sensation levels re: audiometric thresholds for individual subjects (equal-SL). Spectral weights were estimated in conditions where the amplitudes of the individual tones were perturbed slightly on every presentation. Sensitivity was similar in all conditions for normal-hearing and hearing-impaired listeners. The presence of perturbation and equal-SL components increased thresholds for both groups, but only small differences in weighting strategy were measured between the groups depending on whether the equal-SPL or equal-SL condition was tested. The average data suggest that normal-hearing listeners may rely more on the central components of the spectrum whereas hearing-impaired listeners may have been more likely to use the edges. However, individual weighting functions were quite variable, especially for the HI listeners, perhaps reflecting difficulty in processing changes in spectral shape due to hearing loss. Differences in weighting strategy without changes in sensitivity suggest that factors other than spectral weights, such as internal noise or difficulty encoding a reference stimulus, also may dominate performance.  相似文献   

11.
The purpose of this experiment was to evaluate the utilization of short-term spectral cues for recognition of initial plosive consonants (/b,d,g/) by normal-hearing and by hearing-impaired listeners differing in audiometric configuration. Recognition scores were obtained for these consonants paired with three vowels (/a,i,u/) while systematically reducing the duration (300 to 10 ms) of the synthetic consonant-vowel syllables. Results from 10 normal-hearing and 15 hearing-impaired listeners suggest that audiometric configuration interacts in a complex manner with the identification of short-duration stimuli. For consonants paired with the vowels /a/ and /u/, performance deteriorated as the slope of the audiometric configuration increased. The one exception to this result was a subject who had significantly elevated pure-tone thresholds relative to the other hearing-impaired subjects. Despite the changes in the shape of the onset spectral cues imposed by hearing loss, with increasing duration, consonant recognition in the /a/ and /u/ context for most hearing-impaired subjects eventually approached that of the normal-hearing listeners. In contrast, scores for consonants paired with /i/ were poor for a majority of hearing-impaired listeners for stimuli of all durations.  相似文献   

12.
The ability of hearing-impaired (HI) listeners to use high-rate envelope information in a competing-talker situation was assessed. In experiment 1, signals were tone vocoded and the cutoff frequency (f(c)) of the envelope extraction filter was either 50?Hz (E filter) or 200?Hz (P filter). The channels for which the P or E filter was used were varied. Intelligibility was higher with the P filter regardless of whether it was used for low or high center frequencies. Performance was best when the P filter was used for all channels. Experiment 2 explored the dynamic range over which HI listeners made use of high-rate cues. In each channel of a vocoder, the envelope extracted using f(c)?=?16?Hz was replaced by the envelope extracted using f(c)?=?300?Hz, either at the peaks or valleys, with a parametrically varied "switching threshold." For a target-to-background ratio of +5?dB, changes in speech intelligibility occurred mainly when the switching threshold was between -8 and +8?dB relative to the channel root-mean-square level. This range is similar in width to, but about 3?dB higher in absolute level than, that found for normal-hearing listeners, despite the reduced dynamic range of the HI listeners.  相似文献   

13.
"Masking release" (MR), the improvement of speech intelligibility in modulated compared with unmodulated maskers, is typically smaller than normal for hearing-impaired listeners. The extent to which this is due to reduced audibility or to suprathreshold processing deficits is unclear. Here, the effects of audibility were controlled by using stimuli restricted to the low- (≤1.5 kHz) or mid-frequency (1-3 kHz) region for normal-hearing listeners and hearing-impaired listeners with near-normal hearing in the tested region. Previous work suggests that the latter may have suprathreshold deficits. Both spectral and temporal MR were measured. Consonant identification was measured in quiet and in the presence of unmodulated, amplitude-modulated, and spectrally modulated noise at three signal-to-noise ratios (the same ratios for the two groups). For both frequency regions, consonant identification was poorer for the hearing-impaired than for the normal-hearing listeners in all conditions. The results suggest the presence of suprathreshold deficits for the hearing-impaired listeners, despite near-normal audiometric thresholds over the tested frequency regions. However, spectral MR and temporal MR were similar for the two groups. Thus, the suprathreshold deficits for the hearing-impaired group did not lead to reduced MR.  相似文献   

14.
Speech-reception thresholds (SRT) were measured for 17 normal-hearing and 17 hearing-impaired listeners in conditions simulating free-field situations with between one and six interfering talkers. The stimuli, speech and noise with identical long-term average spectra, were recorded with a KEMAR manikin in an anechoic room and presented to the subjects through headphones. The noise was modulated using the envelope fluctuations of the speech. Several conditions were simulated with the speaker always in front of the listener and the maskers either also in front, or positioned in a symmetrical or asymmetrical configuration around the listener. Results show that the hearing impaired have significantly poorer performance than the normal hearing in all conditions. The mean SRT differences between the groups range from 4.2-10 dB. It appears that the modulations in the masker act as an important cue for the normal-hearing listeners, who experience up to 5-dB release from masking, while being hardly beneficial for the hearing impaired listeners. The gain occurring when maskers are moved from the frontal position to positions around the listener varies from 1.5 to 8 dB for the normal hearing, and from 1 to 6.5 dB for the hearing impaired. It depends strongly on the number of maskers and their positions, but less on hearing impairment. The difference between the SRTs for binaural and best-ear listening (the "cocktail party effect") is approximately 3 dB in all conditions for both the normal-hearing and the hearing-impaired listeners.  相似文献   

15.
This study investigated the effect of mild-to-moderate sensorineural hearing loss on the ability to identify speech in noise for vowel-consonant-vowel tokens that were either unprocessed, amplitude modulated synchronously across frequency, or amplitude modulated asynchronously across frequency. One goal of the study was to determine whether hearing-impaired listeners have a particular deficit in the ability to integrate asynchronous spectral information in the perception of speech. Speech tokens were presented at a high, fixed sound level and the level of a speech-shaped noise was changed adaptively to estimate the masked speech identification threshold. The performance of the hearing-impaired listeners was generally worse than that of the normal-hearing listeners, but the impaired listeners showed particularly poor performance in the synchronous modulation condition. This finding suggests that integration of asynchronous spectral information does not pose a particular difficulty for hearing-impaired listeners with mild/moderate hearing losses. Results are discussed in terms of common mechanisms that might account for poor speech identification performance of hearing-impaired listeners when either the masking noise or the speech is synchronously modulated.  相似文献   

16.
Temporal modulation transfer functions were obtained using sinusoidal carriers for four normally hearing subjects and three subjects with mild to moderate cochlear hearing loss. Carrier frequencies were 1000, 2000 and 5000 Hz, and modulation frequencies ranged from 10 to 640 Hz in one-octave steps. The normally hearing subjects were tested using levels of 30 and 80 dB SPL. For the higher level, modulation detection thresholds varied only slightly with modulation frequency for frequencies up to 80 Hz, but decreased for high modulation frequencies. The decrease can be attributed to the detection of spectral sidebands. For the lower level, thresholds varied little with modulation frequency for all three carrier frequencies. The absence of a decrease in the threshold for large modulation frequencies can be explained by the low sensation level of the spectral sidebands. The hearing-impaired subjects were tested at 80 dB SPL, except for two cases where the absolute threshold at the carrier frequency was greater than 70 dB SPL; in these cases a level of 90 dB was used. The results were consistent with the idea that spectral sidebands were less detectable for the hearing-impaired than for the normally hearing subjects. For the two lower carrier frequencies, there were no large decreases in threshold with increasing modulation frequency, and where decreases did occur, this happened only between 320 and 640 Hz. For the 5000-Hz carrier, thresholds were roughly constant for modulation frequencies from 10 to 80 or 160 Hz, and then increased monotonically, becoming unmeasurable at 640 Hz. The results for this carrier may reflect "pure" effects of temporal resolution, without any influence from the detection of spectral sidebands. The results suggest that temporal resolution for deterministic stimuli is similar for normally hearing and hearing-impaired listeners.  相似文献   

17.
The present study compared the abilities of normal and hearing-impaired subjects to discriminate differences in the spectral shapes of speechlike sounds. The minimum detectable change in amplitude of a second-formant spectral peak was determined for steady-state stimuli across a range of presentation levels. In many cases, the hearing-impaired subjects required larger spectral peaks than did the normal-hearing subjects. The performance of all subjects showed a dependence upon presentation level. For some hearing-impaired subjects, high presentation levels resulted in discrimination values similar to that of normal-hearing subjects, while for other hearing-loss subjects, increases in presentation level did not yield normal values, even when the second-formant spectral region was presented at levels above the subject's sensitivity thresholds. These results demonstrate that under certain conditions, some sensorineural hearing-impaired subjects require more prominent spectral peaks in certain speech sounds than normal subjects for equivalent performance. For the group of subjects who did not achieve normal discrimination results at any presentation level, application of high-frequency amplification to the stimuli was successful in returning those subjects' performance to within normal values.  相似文献   

18.
Articulation index (AI) theory was used to evaluate stop-consonant recognition of normal-hearing listeners and listeners with high-frequency hearing loss. From results reported in a companion article [Dubno et al., J. Acoust. Soc. Am. 85, 347-354 (1989)], a transfer function relating the AI to stop-consonant recognition was established, and a frequency importance function was determined for the nine stop-consonant-vowel syllables used as test stimuli. The calculations included the rms and peak levels of the speech that had been measured in 1/3 octave bands; the internal noise was estimated from the thresholds for each subject. The AI model was then used to predict performance for the hearing-impaired listeners. A majority of the AI predictions for the hearing-impaired subjects fell within +/- 2 standard deviations of the normal-hearing listeners' results. However, as observed in previous data, the AI tended to overestimate performance of the hearing-impaired listeners. The accuracy of the predictions decreased with the magnitude of high-frequency hearing loss. Thus, with the exception of performance for listeners with severe high-frequency hearing loss, the results suggest that poorer speech recognition among hearing-impaired listeners results from reduced audibility within critical spectral regions of the speech stimuli.  相似文献   

19.
The forward-masking properties of inharmonic complex stimuli were measured both for normal and hearing-impaired subjects. The signal threshold for a 1000-Hz pure-tone probe was obtained for six different maskers, which varied in the number of pure-tone components. The masking stimuli consisted of 1, 3, 5, 7, 9, or 11 components, logarithmically spaced in frequency surrounding the signal and presented at a fixed level of 80 dB SPL per component. In most normal-hearing subjects, the threshold for the probe decreased as the number of masking components was increased, demonstrating that stimuli with more components tended to be less effective maskers. Results from hearing-impaired subjects showed no decrease in threshold with increasing number of masking components. Instead, the thresholds increased as more components were added to the first masker. These results appear to be consistent with suppression effects within the multicomponent maskers for the normal subjects and a lack of suppression effects for the hearing-impaired subjects. The results from the normal-hearing subjects are also consistent with "across-channel" cuing.  相似文献   

20.
The purpose of this study is to specify the contribution of certain frequency regions to consonant place perception for normal-hearing listeners and listeners with high-frequency hearing loss, and to characterize the differences in stop-consonant place perception among these listeners. Stop-consonant recognition and error patterns were examined at various speech-presentation levels and under conditions of low- and high-pass filtering. Subjects included 18 normal-hearing listeners and a homogeneous group of 10 young, hearing-impaired individuals with high-frequency sensorineural hearing loss. Differential filtering effects on consonant place perception were consistent with the spectral composition of acoustic cues. Differences in consonant recognition and error patterns between normal-hearing and hearing-impaired listeners were observed when the stimulus bandwidth included regions of threshold elevation for the hearing-impaired listeners. Thus place-perception differences among listeners are, for the most part, associated with stimulus bandwidths corresponding to regions of hearing loss.  相似文献   