首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Meropenem is a β ‐lactam broad‐spectrum antibiotic and belongs to the subgroup of carbapenems. It is primarily used in intensive care units for intravenous treatment of severe infections. To avoid bacterial resistance or toxic side effects, the determination of serum meropenem concentration is highly advisable. A simple and fast method for the quantitative determination of meropenem in human serum using high‐performance liquid chromatography with ultraviolet detection (HPLC/UV) was developed and validated. Meropenem was determined by an isocratic HPLC using a tris(hydroxymethyl)aminomethane buffer (pH 8.5; 15% methanol) as a mobile phase and UV detection at 300 nm, with a flow rate of 1.0 mL/min and an analysis time of 10 min. Chromatographic separation was performed on a Kinetex C18 column (5 μm, 150 × 4.6 mm). In order to remove undesired serum components, solid‐phase extraction was used for sample preparation. Since meropenem is not stable in solution, sample and stock solution were stored at −80°C. After preparation, samples were stable at room temperature for at least 6 h. The calibration curve was linear from 3.5 to 200 mg/L with a correlation coefficient r 2 of 0.999. The method is accurate with an intra‐ and inter‐assay precision <18.5%.  相似文献   

2.
A simple, specific and sensitive HPLC method has been developed for the determination of metoprolol in human plasma and urine. Separation of metoprolol and atenolol (internal standard) was achieved on an Ace C18 column (5 μm, 250 mm×4.6 mm id) using fluorescence detection with λex=276 nm and λem=296 nm. The mobile phase consists of methanol–water (50:50, v/v) containing 0.1% TFA. The analysis was performed in less than 10 min with a flow rate of 1 mL/min. The assay was linear over the concentration range of 3 – 200 and 5 – 300 ng/mL for plasma and urine, respectively. The LOD were 1.0 and 1.5 ng/mL for plasma and urine, respectively. The LOQ were 3.0 and 5.0 ng/mL for plasma and urine, respectively. The extraction recoveries were found to be 95.6 ± 1.53 and 96.4 ± 1.75% for plasma and urine, respectively. Also, the method was successfully applied to three patients with hypertension who had been given an oral tablet of 100 mg metoprolol.  相似文献   

3.
A new straightforward method based on cloud‐point extraction has been developed, optimized, and validated for the determination of doxepin in human plasma by high‐performance liquid chromatography separation and UV detection. The nonionic surfactant Triton X‐114 was chosen as the extraction solvent. Chromatography separation was performed on a μBondapakR C18 column (4.6 mm id × 300 mm, 3 μm particle size), which was used for isocratic elution at a detection wavelength of 289 nm. Under the optimum conditions, the linear range of doxepin in human plasma was 0.1–0.9 μg/mL. Also, the detection limit, preconcentration factor, and enrichment factor were 0.08 μg/mL, 50, and 49.0, respectively.  相似文献   

4.
In order to develop a method that is completely suitable for the routine therapeutic drug monitoring, a sensitive and fully automated on‐line column extraction apparatus in combination with high‐performance liquid chromatography allowing binary peak focusing was developed and validated for the determination of rifampicin in human plasma. Rifapentine was used as an internal standard. The analytical cycle started with the injection of 100 μL of the sample pretreated by protein precipitation in a Venusil SCX extraction column. After the elution, the analytes were transferred and concentrated in an Xtimate C18 trap column. Finally, the trapped analytes were separated by an Xtimate C18 analytical column and were analyzed by an ultraviolet detector at 336 nm. With this new strategy, continuous on‐line analysis of the compounds was successfully performed. The method showed excellent performance for the analysis of rifampicin in plasma samples, including calibration curve linearity (All r were larger than 0.9996), sensitivity (lowest limit of quantification was 0.12 μg/mL), method accuracy (within 6.6% in terms of relative error), and precision (relative standard deviations of intra‐ and interday precision were less than 7.8%). These results demonstrated that the simple, reliable, and automatic method based on on‐line column extraction and binary peak focusing is a promising approach for therapeutic drug monitoring in complex biomatrix samples.  相似文献   

5.
A method based on ultrasound‐assisted liquid–liquid extraction and high‐performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound‐assisted liquid–liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R2 > 0.9962 over a concentration range of 1–100 μg/L) and repeatability (relative standard deviation < 6.3%). Furthermore, the detection limit (S/N = 3) of the method were ranged from 0.02 to 0.13 μg/L and the quantification limit (S/N = 10) ranged from 0.07 to 0.35 μg/L. Finally, the proposed method was applied to spiked samples and satisfactory results were achieved. These results indicate that ultrasound‐assisted liquid–liquid extraction coupled with high‐performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.  相似文献   

6.
A one‐step ultrasound/microwave‐assisted solid–liquid–solid dispersive extraction procedure was used for the simultaneous determination of eight neonicotinoids (dinotefuran, nitenpyram, thiamethoxam, clothianidin, imidacloprid, acetamiprid, thiacloprid, imidaclothiz) in dried Dendrobium officinale by liquid chromatography combined with electrospray ionization triple quadrupole tandem mass spectrometry in multiple reaction monitoring mode. The samples were quickly extracted by acetonitrile and cleaned up by the mixed dispersing sorbents including primary secondary amine, C18, and carbon‐GCB. Parameters that could influence the ultrasound/microwave‐assisted extraction efficiency such as microwave irradiation power, ultrasound irradiation power, temperature, and solvent were investigated. Recovery studies were performing well (70.4–113.7%) at three examined spiking levels (10, 50, and 100 μg/kg). Meanwhile, the limits of quantification for the neonicotinoids ranged from 0.87 to 1.92 μg/kg. The method showed good linearity in the concentration range of 1–100 μg/L with correlation coefficients >0.99. This quick and useful analytical method could provide a basis for monitoring neonicotinoid insecticide residues in herbs.  相似文献   

7.
A simple and selective high‐performance liquid chromatography method coupled with fluorescence detection was developed for the simultaneous measurement of trace levels of four estrogens (estrone, estradiol, estriol and 17α‐ethynyl estradiol) in environmental matrices. For feces samples, solid–liquid extraction was applied with a 1:1 v/v mixture of acetonitrile and ethyl acetate as the extraction solvent. For liquid samples (e.g., leachate and groundwater), hydrophobic/lipophilic balanced automated solid‐phase extraction disks were selected due to their high recoveries compared to conventional C18 disks. Chromatographic separations were performed on a reversed‐phase C18 column gradient‐eluted with a 45:55 v/v mixture of acetonitrile and water. The detection limits were down to 1.1 × 10?2 (estrone), 4.11 × 10?4 (estradiol), 5.2 × 10?3 (estriol) and 7.18 × 10?3 μg/L (17α‐ethynyl estradiol) at excitation/emission wavelengths of 288/310 nm, with recoveries in the range of 96.9 ± 3.2–105.4 ± 3.2% (n = 3). The method was successfully applied to determine estrogens in feces and water samples collected at livestock farms and a major river in Northeast China. We observed relatively high abundance and widespread distribution of all four estrogens in our sample collections, implying the urgency for a comprehensive and intricate investigation of estrogenic fate and contamination in our researched area.  相似文献   

8.
We have developed a method of liquid chromatography in tandem with mass spectrometry to monitor therapeutic levels of imatinib in plasma, a selective inhibitor of protein tyrosine kinase. After solid‐phase extraction of plasma samples, imatinib and its internal standard, imatinib‐D8, were eluted with Zorbax SB‐C18 at 60 °C, under isocratic conditions through a mobile phase consisting of 4 mm ammonium formate, pH: 3.2 (solution A) and acetonitrile solution B. The flow rate was 0.8 mL/min with 55% solution A + 45% solution B. Imatinib was detected and quantified by mass spectrometry with electrospray ionization operating in selected‐reaction monitoring mode. The calibration curve was linear in the range 10–5000 ng/mL, the lower limit of quantitation being 10 ng/mL. The method was validated according to the recommendations of the Food and Drug Administration, including tests of matrix effect (bias < 10%) and recovery efficiency (>80 and <120%). The method is precise (coefficient of variance intra‐day <2% and inter‐day <7%), accurate (95–108%), sensitive and specific. It is a simple method with very fast recording time (1.2 min) that is applicable to clinical practice. This will permit improvement of the pharmacological treatment of patients. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
10.
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.  相似文献   

11.
A novel microextraction method, termed microwave‐assisted ionic liquid/ionic liquid dispersive liquid–liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high‐performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1‐hexyl‐3‐methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1‐butyl‐3‐methylimidazolium tetrafluoroborate. In addition, an ion‐pairing agent (NH4PF6) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00–250.00 μg/L, with the correlation coefficients of 0.9982–0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7–105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples.  相似文献   

12.
In recent years, the use of human saliva for diagnostic purposes has evoked great interest. Thus, the aim of this study was to choose the optimal solid‐phase extraction cartridges and extraction solvents for the quantitation of venlafaxine in saliva. Blank saliva samples spiked with venlafaxine concentrations between 25 and 750 ng/mL were analyzed using five solid‐phase extraction columns (C18, C8, Strata‐X, Strata‐X‐C, and Strata‐X‐AW), washing solvents (deionized water, phosphate buffer at pH 5.5, and their mixtures with methanol), and elution solvents (methanol, acetonitrile, and their mixtures with 25% ammonia). A high‐performance liquid chromatography system was used to quantify venlafaxine in saliva. The results of this study revealed that nine of 25 procedures enabled quantitation of venlafaxine in the tested concentration range. The procedure that used a C18 cartridge, a mixture of methanol and deionized water as the washing solvent, and methanol as the elution solvent was the most effective and allowed quantitation of all venlafaxine concentrations with an acceptable recovery. In contrast, the Strata‐X‐C cartridge could not detect venlafaxine at the lowest concentration (25 ng/mL). The data acquired from the high‐performance liquid chromatography system were confirmed by a multivariate data analysis.  相似文献   

13.
Levetiracetam is an antiepileptic drug for the treatment of psychiatric patients. In this study, a selective, straightforward, and rapid online heart‐cutting liquid chromatography method was developed for the therapeutic drug monitoring of levetiracetam. This method allows for the determination of levetiracetam in human plasma without complex sample preparation. The mobile phases consisted of 30 mM aq. orthophosphoric acid solution/methanol (70:30) at a flow rate of 1 mL/min for the first system and 10 mM aq. orthophosphoric acid solution/methanol (55:45) at a flow rate of 1 mL/min for the second system. The first separation was carried out on a GL Sciences Intersil ODS‐3 column (4.6 mm × 150 mm, 3 µm) and the second separation was carried out on a Restek Ultra PFPP column (4.6 mm × 150 mm, 5 µm). The detection was carried out at 205 nm for both systems. The method was validated for selectivity and linearity, which were in the 6–60 µg/mL range. Intra‐ and interassay accuracies were <112.6%, and the intra‐ and interassay precisions were <6.4% for all quality control samples. The lower limit of quantitation was 6 µg/mL. The developed method was successfully applied for therapeutic drug monitoring of plasma samples from patients.  相似文献   

14.
Levofloxacin, pefloxacin, ciprofloxacin and moxifloxacin are four fluoroquinolones used in the treatment of serious bacterial infections. The antibacterial activity of fluoroquinolones is concentration dependent. Therefore, therapeutic drug monitoring in daily clinical practice is warranted to ensure the therapy's efficacy and prevent bacterial resistance. The purpose of the present study was to develop a method using high‐pressure liquid chromatography with an ultraviolet detector for simultaneous quantification of these four fluoroquinolones in human plasma. A 50 μL aliquot of plasma was precipitated by 200 μL of methanol using gatifloxacin as internal standard. The chromatographic separation was performed on a Kinetex XB‐C18 column using a mobile phase composed of a mixture of orthophosphoric acid 0.4% (v/v), acetonitrile and methanol at a flow rate of 1.2 mL/min. Dual UV wavelength mode was used, with levofloxacin and moxifloxacin monitored at 293 nm, and pefloxacin and ciprofloxacin monitored at 280 nm. The calibration was linear over the ranges of 0.125–25 mg/L for levofloxacin, 0.1–20mg/L for moxifloxacin and 0.05‐10 mg/L for both pefloxacin and ciprofloxacin. Inter‐ and intra‐day trueness and precision were <13% for all the compounds under study. The proposed method was simple, reliable, cost‐effective and suitable for therapeutic drug monitoring or pharmacokinetics studies.  相似文献   

15.
The drug‐transporting proteins can affect the pharmacokinetics and pharmacodymanics of many drugs, resulting in an erratic and unpredictable pharmacological response. The Caco‐2 monolayer is routinely applied to investigate the carrier‐mediated transport of drugs. Therefore, the selection of a marker compound able to characterize the activity of such transporters is crucial. Fexofenadine (FEX), a P‐gp/OATP substrate, can be considered a suitable probe. However, in order to use be used as a marker compound, it is mandatory to develop an analytical method able to quantify this drug during the in vitro permeability assay. An HPLC method with ultraviolet detection was developed; the mobile phase consisted of phosphate buffer (pH 3.2) containing 10 m m of sodium octanosulphonate and acetonitrile (60:40) and the flow rate was set at 1.2 mL/min. Fexofenadine was eluted at 40°C, the retention time was about 4.6 min. The LOD and LOQ values were 1.9 and 6.2 ng/mL, respectively. Verapamil and ketoconazole, the most common P‐gp inhibitors, were eluted as distinct peaks of that corresponding to fexofenadine The method was successfully applied to quantify the amount of FEX transported across the Caco‐2 monolayer and could be an additional tool for those investigating the role of membrane transporters on drug absorption. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
In this work, a simple method, namely, tandem dispersive liquid–liquid microextraction, with a high sample clean‐up is applied for the rapid determination of the antidementia drugs rivastigmine and donepezil in wastewater and human plasma samples. This method, which is based on two consecutive dispersive microextractions, is performed in 7 min. In the method, using a fast back‐extraction step, the applicability of the dispersive microextraction methods in complicated matrixes is conveniently improved. This step can be performed in less than 2 min, and very simple tools are required for this purpose. To achieve the best extraction efficiency, optimization of the variables affecting the method was carried out. Under the optimized experimental conditions, the relative standard deviations for the method were in the range of 6.9–8.7%. The calibration curves were obtained in the range of 2–1100 ng/mL with good correlation coefficients, higher than 0.995, and the limits of detection ranged between 0.5 and 1.0 ng/mL.  相似文献   

17.
A vortex‐assisted liquid–liquid micro‐extraction coupled with high‐performance liquid chromatography, with UV–vis, is proposed to pre‐concentrate methyl methacrylate and to improve separation in biological matrices. The use of 1‐octanol as extracting phase, its volume, the need for a dispersant agent, the agitation conditions and the cooling time before phase separation were evaluated. In optimum conditions, enrichment factors of 20 (±0.5) and enrichment recovery of 99% were obtained. The straightforward association of this extraction process with the HPLC method, previously regulated by the International Organization for Standardization, afforded a detection limit of 122 ng/mL and a quantification limit of 370 ng/mL. The within‐batch precision, relative standard deviation, was 3% for a sample with 1.49 µg/mL and 4% for a sample with 13.4 µg/mL. The results showed a between batch‐precision of 21% for experiments performed on five different days, for a sample with a concentration of 1.10 µg/mL in methyl methacrylate. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A solid–liquid extraction method in combination with high‐performance liquid chromatography and tandem mass spectrometry was developed and optimized for extraction and analysis of organophosphorus flame retardants in soil and fish. Methanol was chosen as the optimum extraction solvent, not only in terms of extraction efficiency, but also for its broader analyte coverage. The subsequent clean‐up by solid‐phase extraction is required to eliminate matrix coextractives and reduce matrix effects. Recoveries of the optimized method were 50–121% for soil and 47–123% for biota, both with high precision (RSDs <12% in soil and <23% in biota). The method limits of detection ranged from 0.06 to 0.20 ng/g dry weight and between 0.02 and 0.30 ng/g wet weight for soil and biota samples, respectively. However, samples with a high lipid content produce several problems as solid‐phase extraction cartridge clogging that increase variability and analysis time. The method was successfully applied for the determination of organophosphorus flame retardants in soil and fish from L'Albufera Natural Park (Valencia, Spain). Target compounds were detected in all soil and fish samples with values varying from 13.8 to 89.7 ng/g dry weight and from 3.3 to 53.0 ng/g wet weight, respectively.  相似文献   

19.
This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid–liquid extraction and ultra‐high‐performance liquid chromatography coupled with ultra‐high‐resolution TOF mass spectrometry. After liquid–liquid extraction, beta blockers were separated on a reverse‐phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients.  相似文献   

20.
This paper describes a method for the determination of eight sedative hypnotics (benzodiazepines and barbiturates) in sewage sludge using pressurized liquid extraction and liquid chromatography with tandem mass spectrometry. Pressurized liquid extraction operating conditions were optimized and maximum recoveries were reached using methanol under the following operational conditions: 100ºC, 1500 psi, extraction time of 5 min, one extraction cycle, flush volume of 60% and purge time of 120 s. Pressurized liquid extraction recoveries were higher than 88% for all the compounds except for carbamazepine (55%). The repeatability and reproducibility between days, expressed as relative standard deviation (n = 5), were lower than 6 and 10%, respectively. The detection limits for all compounds were lower than 12.5 μg/kg of dry weight. The method was applied to determine benzodiazepines and barbiturates in sewage sludge from urban sewage treatment plants, and carbamazepine showed the highest concentration (7.9–18.9 μg/kg dry weight).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号