首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Oxyresveratrol (trans‐2,4,3′,5′‐tetrahydroxystilbene) is a major compound isolated from Smilax china, a Chinese herbal medicine. The rat urine and bile samples were pretreated by solid‐phase extraction method after oral administration at a dose of 100 mg/kg of oxyresveratrol. Seven metabolites were identified by LC‐MS/MS method with electrospray ionization in negative ion mode. The results indicated that main metabolites of oxyresveratrol were monoglucuronided and monosulfated oxyresveratrol. Based on the results, the metabolic pathway of oxyresveratrol in rat urine and bile was proposed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive and selective liquid chromatographic–tandem mass spectrometric (LC–MS/MS) method for the determination of bergenin and its phase II metabolite in rat plasma, bile and urine has been developed. Biological samples were pretreated with protein precipitation extraction procedure and enzymatic hydrolysis method was used for converting glucuronide metabolite to its free form bergenin. Detection and quantitation were performed by MS/MS using electrospray ionization and multiple reaction monitoring. Negative electrospray ionization was employed as the ionization source. Sulfamethoxazole was used as the internal standard. The separation was performed on a reverse‐phase C18 (250 × 4.6 mm, 5 μm) column with gradient elution consisting of methanol and 0.5% aqueous formic acid. The concentrations of bergenin in all biological samples were in accordance with the requirements of validation of the method. After oral administration of 12 mg/kg of the prototype drug, bergenin and its glucuronide metabolite were determined in plasma, bile and urine. Bergenin in bile was completely excreted in 24 h, and the main excreted amount of bergenin was 97.67% in the first 12 h. The drug recovery in bile within 24 h was 8.97%. In urine, the main excreted amount of bergenin was 95.69% in the first 24 h, and the drug recovery within 24 h was <22.34%. Total recovery of bergenin and its glucuronide metabolite was about 52.51% (20.31% in bile within 24 h, 32.20% in urine within 48 h). The validated method was successfully applied to pharmacokinetic and excretion studies of bergenin.  相似文献   

3.
A robust and sensitive high‐performance liquid chromatographic–tandem mass spectrometric (HPLC‐MS/MS) assay for the high‐throughput quantification of the antihypertensive drug azelnidipine in human plasma was developed and validated following bioanalytical validation guidelines. Azelnidipine and internal standard (IS), telmisartan, were extracted from human plasma by precipitation protein and separated on a C18 column using acetonitrile–methanol–ammonium formate with 0.1% formic acid as mobile phase. Detection was performed on a turbo‐spray ionization source (ESI) and mass spectrometric positive multiple reaction monitoring mode (+MRM) using the respective transitions m/z 583.3 → 167.2 for azelnidipine and m/z 515.3 → 497.2 for IS. The method has a wide analytical measuring range from 0.0125 to 25 ng/mL. For the lowest limit of quantitation, low, medium and high quality controls, intra‐ and interassay precisions (relative standard deviation) were 3.30–7.01% and 1.78–8.09%, respectively. The drug was sufficiently stable under all relevant analytical conditions. The main metabolite of azelnidipine, M‐1 (aromatized form), was monitored semiquantitatively using the typical transition m/z 581.3 → 167.2. Finally, the method was successfully applied to a clinical pharmacokinetic study in human after a single oral administration of azelnidipine 8 mg. The assay meets criteria for the analysis of samples from large research trials. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
A sensitive and selective liquid chromatography coupled to tandem mass spectrometry (LC‐MS/MS) was developed and validated for the determination of salbutamol in human plasma and urine, and successfully applied to the pharmacokinetic study of salbutamol in Chinese healthy volunteers after inhalation of salbutamol sulfate aerosol. Salbutamol and the internal standard (IS) acetaminophen in plasma and urine were extracted with ethyl acetate, separated on a C18 reversed‐phase column, eluted with mobile phase of acetonitrile–ammonium acetate (5 m m ; 30:70, v/v), ionized by positive ion pneumatically assisted electrospray and detected in the multi‐reaction monitoring mode using precursor → product ions of m/z 240.2 → 148.1 for salbutamol and 152 → 110 for the IS. The lower limits of quantitation of salbutamol in human plasma and urine by this method were 0.02 and 1 ng/mL, respectively. The specificity, matrix effect, recovery, sensitivity, linearity, accuracy, precision and several stabilities were validated for salbutamol in human plasma and urine. In conclusion, the validation results showed that this method is robust, specific and sensitive, and can successfully fulfill the requirement of clinical pharmacokinetic study of salbutamol in healthy Chinese volunteers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
We aimed to investigate the pharmacokinetics, bioavailability and urinary excretion of scopolin and its metabolite scopoletin in rats. An LC–tandem mass spectrometry (MS/MS) method for simultaneous determination of scopolin and scopoletin in rat biomatrices was developed and validated over a plasma and urine concentration range of 5.0–2000 ng/mL. Chromatographic separation was performed on a Hypersil GOLD C18 column with acetonitrile and 0.1% formic acid in water as mobile phase with gradient elution. Detection was performed in the positive ionization and selected reaction monitoring mode. The intra‐ and inter‐batch precision and accuracy, extraction recovery and matrix effect and stability of scopolin and scopoletin were well within the acceptable limits of variation. There was no gender‐related difference in the pharmacokinetic profiles of scopolin. There were significant differences in total area under the concentration–time curve (AUC), time required to achieve a maximal concentration (Tmax) and apparent clearance from plasma (Cl/F) of scopoletin between the male and female rats (p < .05). The bioavailability (F) of scopolin was exceptionally low. The maximal excretion rates were 7.61 μg/h and 7.15 μg/h for scopolin and 31.68 μg/h and 25.58 μg/h for scopoletin in male and female rats, respectively. The LC–MS/MS method was successfully applied to the pharmacokinetic, bioavailability and urinary excretion studies of scopolin and its metabolite scopoletin following a single administration of scopolin to rats.  相似文献   

6.
Oral prochlorperazine (PCZ), an antiemetic, undergoes extensive first-pass metabolism. The study developed a simultaneous analytical method for PCZ and its major metabolites, prochlorperazine sulfoxide (PCZSO), N-demethylprochlorperazine (NDPCZ) and 7-hydroxyprochlorperazine (PCZOH), in human plasma using an isocratic liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Deproteinized plasma specimens were separated using a 3 μm particle size octadecylsilyl column, and the run time was 10 min. The calibration curves were linear over the concentration ranges of 0.01-40 μg/L for PCZ, NDPCZ and PCZOH, and 0.05-80 μg/L for PCZSO. The intra- and inter-assay precisions and accuracies were within 7.0 and 99-104% and within 9.0 and 99-105%, respectively. The lower limits of quantification in human plasma were 10 ng/L for PCZ, NDPCZ and PCZOH, and 50 ng/L for PCZSO. The validated method was applied to the determination of plasma samples in 37 cancer patients receiving PCZ. Large interindividual variations were observed in plasma concentrations of PCZ, PCZSO, NDPCZ and PCZOH (relative standard deviation, 89.4, 88.7, 86.4 and 78.2%, respectively). In conclusion, this simultaneous LC-MS/MS method with acceptable analytical performance can be helpful for evaluating the pharmacokinetics of PCZ, including the determination of its metabolites in cancer patients and in clinical research.  相似文献   

7.
A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase. The mobile phase consists of 85% acetonitrile, 15% water, 0.5% acetic acid and 0.04% trifluoroacetic acid and runs isocratically at a flow rate of 2.0 mL/min. The column ef fluent was split so that 50% of it was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 2.0 min per injection. Atenolol and the internal standard, atenolol-d(7), showed a retention time of 1.0 min. The inter-day and intra-day precision and accuracy of the quality control samples were <5.3% relative standard deviation and <8.0% relative error, respectively. To explore the application of the current method for the analysis of other beta-blocking agents, propranolol and metoprolol were tested under the same chromatographic conditions with retention times of 0.68 and 0.75 min, respectively. The present method could be used for therapeutic drug monitoring, pharmacokinetic and drug--drug interaction studies of beta-blocking agents.  相似文献   

8.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

9.
A rapid and sensitive LC/MS/MS assay was developed and validated for the determination of clopidogrel in human plasma. Clopidogrel was extracted by single liquid-liquid extraction with pentane, and chromatographic separations were achieved on a C(18) column. The method was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), stability, accuracy and precision. The multiple reaction monitoring was based on m/z transition of 322.2 --> 211.9 for clopidogrel and 264.1 --> 125.1 for ticlopidine (internal standard). The total analytical run time was relatively short (3 min), and the LLOQ was 10 pg/mL using 0.5 mL of human plasma. The assay was linear over a concentration range from 10 to 10,000 pg/mL (r > 0.999). The intra- and inter-day accuracies were 101.3-108.8 and 98.4-103.5%, respectively, and the intra- and inter-day assay precisions were 1.9-5.5 and 4.4-8.1%, respectively. The developed assay method was applied to a pharmacokinetic study in human volunteers after oral administration of clopidogrel at a dose of 150 mg.  相似文献   

10.
Hu W  Xu Y  Liu F  Liu A  Guo Q 《Biomedical chromatography : BMC》2008,22(10):1108-1114
A sensitive, specific and rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described and validated for the quantification of ambroxol in human plasma using enalaprilat as the internal standard (IS). Chromatographic separation was performed on a Lichrospher CN column with a mobile phase of methanol and water (containing 0.1% formic acid) (70:30, v/v). The total run time was 5.0 min for each sample. The analytes was detected by mass spectrometry with electrospray ionization source in positive selected reaction monitoring mode. The precursor-fragment ion reaction for ambroxol was m/z 378.9 --> 263.8, and for IS was m/z 349.0 --> 205.9. The linearity was established over the concentration range of 1.56-400.00 ng/mL. The inter-day and the intra-day precisions were all within 10%. A simple protein precipitation with methanol was adopted for sample preparation. The extraction recoveries of ambroxol and IS were higher than 90.80%. The validated method was successfully applied in pharmacokinetic study after oral administration of 90 mg ambroxol to 24 healthy volunteers.  相似文献   

11.
A simple, rapid and sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay method has been developed and fully validated for the simultaneous quantification of tetrabenazine and its active metabolites α‐dihydrotetrabenazine and β‐dihydrotetrabenazine in human plasma. Tetrabenazine d7 was used as internal standard (IS). The analytes were extracted from 200 μL aliquots of human plasma via solid‐phase extraction using C18 solid‐phase extraction cartridges. The reconstituted samples were chromatographed on a Zorbax SB C18 column using a 60:40 (v/v) mixture of acetonitrile and 5 mm ammonium acetate as the mobile phase at a flow rate of 0.8 mL/min. The API‐4000 LC‐MS/MS in multiple reaction‐monitoring mode was used for detection. The calibration curves obtained were linear (r2 ≥ 0.99) over the concentration range of 0.01–5.03 ng/mL for tetrabenazine and 0.50–100 ng/mL for α‐dihydrotetrabenazine and β‐dihydrotetrabenazine. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. The method is precise and sensitive enough for its intended purpose. A run time of 2.5 min for each sample made it possible to analyze more than 300 plasma samples per day. The proposed method was found to be applicable to clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A liquid chromatographic–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0834 and its amide hydrolysis metabolite (M1) in human plasma to support clinical development. The method consisted of semi‐automated 96‐well protein precipitation extraction for sample preparation and LC‐MS/MS analysis in positive ion mode using TurboIonSpray® for analysis. D6‐GDC‐0834 and D6‐M1 metabolite were used as internal standards. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 1 – 500 ng/mL for both GDC‐0834 and M1 metabolite. The accuracy (percentage bias) at the lower limit of quantitation (LLOQ) was 5.20 and 0.100% for GDC‐0834 and M1 metabolite, respectively. The precision (CV) for samples at the LLOQ was 3.13–8.84 and 5.20–8.93% for GDC‐0834 and M1 metabolite, respectively. For quality control samples at 3, 200 and 400 ng/mL, the between‐run CV was ≤7.38% for GDC‐0834 and ≤8.20% for M1 metabolite. Between run percentage bias ranged from ?2.76 to 6.98% for GDC‐0834 and from ?6.73 to 2.21% for M1 metabolite. GDC‐0834 and M1 metabolite were stable in human plasma for 31 days at ?20 and ?70°C. This method was successfully applied to support a GDC‐0834 human pharmacokinetic‐based study. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A direct injection liquid chromatography–electrospray ionization–tandem mass spectrometric method (LC‐ESI‐MS/MS) was developed and validated for the rapid and simple determination of 13 phenylalkylamine derivatives. Eight deuterium‐labeled compounds were prepared for use as internal standards (ISs) to quantify the analytes. Urine samples mixed with ISs were centrifuged, filtered through 0.22 µm filters and then injected directly into the LC‐ESI‐MS/MS system. The mobile phase was composed of 0.2% formic acid and 2 mM ammonium formate in distilled water and 0.2% formic acid and 2 mM ammonium formate in acetonitrile. The analytical column was a Capcell Pak MG‐II C18 (150 × 2.0 mm i.d., 5 µm, Shiseido). Separation and detection of the analytes were accomplished within 10 min. The linear ranges were 5–750 ng/mL (ephedrine and fenfluramine), 10–750 ng/mL (3,4‐methylenedioxyamphetamine, phendimetrazine, methamphetamine, 3,4‐methylenedioxyethylamphetamine and benzphetamine), 20–750 ng/mL (norephedrine, amphetamine, phentermine and ketamine) and 30–1000 ng/mL (3,4‐methylenedioxymethamphetamine and norketamine), with determination coefficients, R2, ≥ 0.9967. The intra‐day and inter‐day precisions were within 19.1%. The intra‐day and inter‐day accuracies ranged from ?16.0 to 18.7%. The lower limits of quantification for all the analytes were lower than 26.5 ng/mL. The applicability of the method was examined by analyzing urine samples from drug abusers (n = 30). Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
A sensitive and specific method using liquid chromatography–electrospray tandem mass spectrometry (LC‐MS/MS) for the determination of pinaverium bromide in human plasma was developed and validated. Pinaverium bromide and an internal standard (paclitaxel) were isolated from plasma samples by precipitating plasma, and determined by LC‐MS/MS in multiple‐reaction monitoring mode. The main metabolite of pinaverium bromide and endogenous substances in plasma did not show any interference. The calibration curve was linear over the plasma concentration range of 10.0–10000.0 pg/mL with a correlation coefficient of 0.9979. The relative standard derivations intra‐ and inter‐day at 30.0, 300.0 and 8000.0 pg/mL in plasma were less than 15%. The absolute recoveries of pinaverium bromide and the internal standard were 99.7–111.7 and 106.2%, respectively. The lower limit of quantitation was 10 pg/mL. The analytical method was successfully applied to study the pharmacokinetics of pinaverium bromide tablets in healthy Chinese volunteers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
In the present study, the development and validation of an LC‐MS/MS method for quantifying mefenamic acid in human plasma is described. The method involves liquid–liquid extraction using diclofenac as an internal standard (IS). Chromatographic separation was achieved on a Thermo Hypurity C18, 50 × 4.6 mm, 5 µm column with a mobile phase consisting of 2 m m ammonium acetate buffer and methanol (pH 4.5 adjusted with glacial acetic acid; 15:85, v/v) at a flow‐rate of 0.75 mL/min and the total run time was 1.75 min. Analyte was introduced to the LC‐MS/MS using an atmospheric pressure ionization source. Both the drug and IS were detected in negative‐ion mode using multiple reaction monitoring m/z 240.0 → 196.3 and m/z 294.0 → 250.2, respectively, with a dwell time of 200 ms for each of the transitions. The standard curve was linear from 20 to 6000 ng/mL. This assay allows quantification of mefenamic acid at a concentration as low as 20 ng/mL in human plasma. The observed mean recovery was 73% for the drug. The applicability of this method for pharmacokinetic studies has been established after successful application during a 12‐subject bioavailibity study. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
Sirolimus, an effective immunosuppressive agent, is used for drug eluting stents. During stent development, an analytical method for the determination of sirolimus in tissue needs to be established. Normally, tissue samples are homogenized and then analyzed against the calibration standards prepared in a tissue homogenate. This approach provides insufficient control of the homogenization process. In this paper, tissue quality control samples were introduced for the optimization of the homogenization process during method development, but also allowance for the performance evaluation of the entire analytical process. In addition, a new approach using rabbit blood as a homogenization medium was developed to stabilize sirolimus in rabbit tissue homogenates. Calibration standards and quality controls were prepared by spiking different sirolimus working solutions into rabbit blood. Homogenization quality control samples were prepared by injecting other sirolimus working solutions into empty test tubes and pre-cut arteries within pre-defined masses. A high-throughput homogenization procedure was optimized based on the specific chemical properties of sirolimus. The linear dynamic range was between 49.9 pg/mL and 31.9 ng/mL to accommodate the expected artery homogenate concentrations. Additionally, quality controls in rabbit blood were also used in the extraction to support the calibration standards. The accuracy and precision of the quality controls in rabbit blood reflect the extraction performance and the accuracy and precision of the homogenization tissue quality controls reflect the overall performance of the method. The mean bias was between -4.5 and 0.2% for all levels of quality controls in the blood and between 4.8 and 14.9% for all levels of the homogenization tissue quality controls. The CVs of all concentration levels were < or =5.3% for the quality controls in blood and < or =9.2% for the homogenization tissue quality controls. The method was successfully applied to determine the concentration of sirolimus in the rabbit arteries.  相似文献   

17.
A rapid and sensitive ultraperformance liquid chromatography tandem mass spectrometry assay was developed for the simultaneous analysis of oxcarbazepine and its main metabolite in human plasma. The assay involves a simple solid‐phase extraction procedure of 0.3 mL of human plasma and analysis was performed on a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. Separation was achieved on an Acquity UPLC™ BEH C18 column (50 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.25 mL/min and imipramine was used as the internal standard. The standard calibration curve was linear over the range 9.580–5070.205 ng/mL for oxcarbazepine (OXC) and 19.444–10290.800 ng/mL for 10,11‐dihydro‐10‐hydroxycarbamazepine (MHD), expressed by the linear correlation coefficient r2, which was better than 0.995 for OXC and MHD. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recoveries were 81.0, 89.6 and 66.6% for OXC, MHD and imipramine, respectively. The total run time was 1.5 min only for each sample, which makes it possible to analyze more than 350 samples per day. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
A liquid chromatography–tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7‐hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7‐hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5–100 ng/mL for granisetron and 0.1–100 ng/mL for 7‐hydroxy granisetron in human plasma samples, and 2–2000 ng/mL for granisetron and 2–1000 ng/mL for 7‐hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was <10%. No significant matrix effects were observed for granisetron or 7‐hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry (LC-MS/MS) quantitative detection method, using cefalexin as internal standard, was developed for the analysis of faropenem in human plasma and urine. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a C18 reversed-phase column with 0.1% formic acid-methanol (45:55, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves with good linearities (r=0.9991 for plasma sample and r=0.9993 for urine sample) were obtained in the range 5-4000 ng/mL for faropenem. The limit of detection was 5 ng/mL. Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of faropenem in humans, and to our knowledge, it is the first time the pharmacokinetic of faropenem has been elucidated in vivo using LC-MS/MS.  相似文献   

20.
Huperzine A is a potent, reversible acetylcholinesterase inhibitor. In the present work, a rapid and sensitive LC-MS-MS method for the determination of huperzine A in human plasma using codeine phosphate as internal standard has been developed and validated. The analyte and internal standard were extracted from plasma using ethyl acetate, chromatographed on a C(18) column (5 microm, 150 x 4.6 mm i.d.) with a mobile phase consisting of 1% formic acid-methanol (40:60, v/v), and detected using a tandem mass spectrometer with a TurboIonSpray ionization interface. The run time was only 2 min. Good linearity was achieved in the range 0.126 -25.2 ng/mL and the limit of detection in plasma was 0.064 ng/mL. The average recovery for huperzine A was 83.4% from plasma. The analytical sensitivity and accuracy of this assay is adequate for characterization of huperzine A in human plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号