首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Perampanel (Fycompa®), a novel α‐amino‐3‐hydroxy‐5‐methyl‐4‐isoxazolepropionic acid (AMPA) receptor antagonist, is registered for the adjunctive treatment of patients (aged ≥12 years) with refractory partial‐onset seizures. To support therapeutic drug monitoring, a simple high‐performance liquid chromatography (HPLC) assay with fluorescence detection was developed to determine perampanel concentrations in human plasma and validated to support clinical trials. Human plasma samples (1.0 mL) were processed by liquid extraction using diethyl ether, followed by chromatographic separation on a YMC Pack Pro C18 column (150 × 4.6 mm i.d., 5 µm) with isocratic elution of acetonitrile–water–acetic acid–sodium acetate (840:560:3:1.8, v/v/v/w) at a flow rate of 1.0 mL/min. Column eluent was monitored at excitation and emission wavelengths of 290 and 430 nm, respectively. The assay was linear (range 1.0–500 ng/mL) and this could be extended to 25 µg/mL by 50‐fold dilution integrity. No endogenous peaks were detected in the elution of analytes in drug‐free blank human plasma from six individuals and no interference was observed with co‐medications tested. Intra‐ and inter‐batch reproducibility studies demonstrated accuracy and precision within the acceptance criteria of bioanalytical guidelines. Validation data demonstrated that our assay is simple, selective, reproducible and suitable for therapeutic drug monitoring of perampanel. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
Rapid and simple HPLC‐UV and LC‐MS methods were developed and validated for the quantification of ertapenem (Invanz?) in human plasma. Ertapenem is a unique drug in that current dosing recommendations call for a 1 g dose for normal renal function patients, despite body weight. These assays, which involve a protein precipitation followed by liquid–liquid extraction, allow for fast therapeutic drug monitoring of ertapenem in patients, which is especially useful in special populations. Both methods were sufficient to baseline resolve meropenem (internal standard) and ertapenem, and were validated over 3 days using a six‐point calibration curve (0.5–50 µg/mL). Validation was collected using four different points on the calibrations curve yielding acceptable precision (<15% inter‐day and intra‐day; <20% for lower limit of quantitation, LLOQ) as well as accuracy (<15% inter‐day and intra‐day; <20% for LLOQ). The lower limit of detection (LOD) was determined to be 0.1 and 0.05 µg/mL for the HPLC‐UV and LC‐MS methods, respectively. The developed HPLC‐UV and LC‐MS methods for ertapenem quantification are fast, accurate and reproducible over the calibration range and can be used to determine ertapenem plasma concentrations for monitoring clinical efficacy. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Cross‐validation (CV) is a common approach for determining the optimal number of components in a principal component analysis model. To guarantee the independence between model testing and calibration, the observation‐wise k‐fold operation is commonly implemented in each cross‐validation step. This operation renders the CV algorithm computationally intensive, and it is the main limitation to apply CV on very large data sets. In this paper, we carry out an empirical and theoretical investigation of the use of this operation in the element‐wise k‐fold (ekf) algorithm, the state‐of‐the‐art CV algorithm. We show that when very large data sets need to be cross‐validated and the computational time is a matter of concern, the observation‐wise k‐fold operation can be skipped. The theoretical properties of the resulting modified algorithm, referred to as column‐wise k‐fold (ckf) algorithm, are derived. Also, its performance is evaluated with several artificial and real data sets. We suggest the ckf algorithm to be a valid alternative to the standard ekf to reduce the computational time needed to cross‐validate a data set. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
A sensitive high‐performance liquid chromatography–tandem mass spectrometric (HPLC‐MS/MS) assay has been developed for the quantitative analysis of vardenafil in human plasma. Vardenafil and the internal standard, alprazolam, were extracted from 0.2 mL aliquots of alkalinized plasma by a single solvent extraction into hexane : dichloromethane. Reversed‐phase chromatographic separation was affected by gradient elution with mobile phases consisting of 10 mM ammonium formate pH 7.0 (solvent A) and methanol (100%, solvent B), delivered at a flow rate of 0.4 mL/min. The analytes were detected by using an electrospray ion source on a 4000 QTrap triple quadrupole mass spectrometer operating in positive ionization mode. The mass transitions were m/z 489.3 → 312.2 for vardenafil and m/z 309.2 → 281.0 for alprazolam. The assay was linear over the concentration range of 0.2–100 ng/mL, with correlation coefficients ≥0.995. The intra‐ and inter‐day precision was less than 5.4% in terms of relative standard deviation and the accuracy was within 12.7% in terms of relative error. The lower limit of quantitation was set at 0.2 ng/mL. The high sensitivity and acceptable performance of the assay allowed its application to the analysis of plasma samples obtained following the oral administration of vardenafil to healthy male volunteers in a pharmacokinetic study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0152 in human plasma to support clinical development. The method consisted of a solid‐phase extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d7‐GDC‐0152 was used as the internal standard. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 0.02–10.0 ng/mL for GDC‐0152. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 99.3% with a precision (%CV) of 13.9%. For quality control samples at 0.0600, 2.00 and 8.00 ng/mL, the between‐run %CV was ≤8.64. Between‐run percentage accuracy ranged from 98.2 to 99.6%. GDC‐0152 was stable in human plasma for 363 days at ?20°C and for 659 days at ?70°C storage. GDC‐0152 was stable in human plasma at room temperature for up to 25 h and through three freeze–thaw cycles. In whole blood, GDC‐0152 was stable for 12 h at 4°C and at ambient temperature. This validated LC‐MS/MS method for determination of GDC‐0152 was used to support clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A simple and fast liquid chromatographic method coupled with fluorescence detection (LC‐FD) is reported, for the first time, for the simultaneous quantification of norfloxacin (NOR), ciprofloxacin (CIP) and lomefloxacin (LOM) in human plasma, using levofloxacin as internal standard (IS). Sample preparation consists of a single‐step precipitation of plasma proteins followed by vortex‐mixing and centrifugation. Chromatographic separation was achieved within 7 min on a reversed‐phase C18 column with a mobile phase consisting of 0.1% aqueous formic acid (pH = 3.0, triethylamine)–methanol (82:18, v/v) pumped isocratically at 1.2 mL/min. The detector was set at excitation/emission wavelengths of 278/450 nm. Calibration curves were linear (r2 ≥ 0.994) in the range of 0.02–5.0 µg/mL, and the limit of quantification was established at 0.02 µg/mL for all analytes (NOR, CIP and LOM). The overall precision did not exceed 8.19% and accuracy was within ±10.91%. NOR, CIP and LOM were extracted from human plasma with an overall mean recovery ranged from 90.1 to 111.5%. No interferences were observed at the retention times of the analytes and IS. This novel LC‐FD method enables the reliable determination of NOR, CIP and LOM in a single chromatographic run, which may be suitable to support human pharmacokinetic‐based studies with those antimicrobial agents. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A sensitive, rapid assay method for estimating ivabradine in human plasma has been developed and validated using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The procedure involved extraction of ivabradine and the internal standard (IS) from human plasma by solid‐phase extraction. Chromatographic separation was achieved using an isocratic mobile phase (0.1% formic acid–methanol, 60:40, v/v) at a flow rate of 1.0 mL/min on an Aglient Eclipse XDB C8 column (150 × 4.6 mm, 5 µm; maintained at 35°C) with a total run time of 4.5 min. Detection was achieved using an Applied Biosystems MDS Sciex (Concord, Ontario, Canada) API 3200 triple‐quadrupole mass spectrometer. The MS/MS ion transitions monitored were 469–177 for ivabradine and 453–177 for IS. Method validation was performed according to Food and Drug Administration guidelines, and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 0.1–200 ng/mL. The lower limit of quantitation achieved was 0.1 ng/mL. Intra‐ and inter‐day precisions were in the range of 1.23–14.17% and 5.26‐8.96%, respectively. Finally, the method was successfully used in a pharmacokinetic study that measured ivabradine levels in healthy volunteers after a single 5 mg oral dose of ivabradine. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A novel stability‐indicating reversed phase ultra‐high performance liquid chromatography (UPLC) coupled photodiode array gradient method was developed for determination of the nifedipine and related compounds. Furthermore, based on the chromatographic conditions and forced degradation studies performed through the development of the related substances method a UPLC isocratic method was validated for the determination of the assay of this active substance. An Acquity Shield RP18 (50 × 3.0 mm 1.7 µm) column was used for separation of nifedipine and its five potential impurities within 11 min, which is 5‐fold less than the official method. A mobile phase consisting of 10 mm ammonium formate (pH 4.5) and methanol, delivered at a flow rate 0.5 mL/min, was employed to achieve a minimum resolution of 2.0 for all consecutive pairs of compounds. The precision value expressed as percentage relative standard deviation for method repeatability and reproducibility was <5.0%. The recoveries for all the related compounds were in the range of 99–105.0%. Linearity was found to be acceptable over the concentration range of 0.25–1.5 µg/mL for nifedipine and its impurities. The limit of quantification for nifedipine was 0.05 µg/mL, which is much less than the European Pharmacopoeia method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A robust, specific and fully validated LC‐MS/MS method as per general practices of industry has been developed for estimation of lacidipine (LAC) with 100 μL of human plasma using lacidipine‐13C8 as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode. A simple liquid–liquid extraction process was used to extract LAC and IS from human plasma. The total run time was 3.0 min and the elution of LAC and IS occurred at 1.96 and 1.97 min; this was achieved with a mobile phase consisting of 5 mm ammonium acetate buffer–acetontrile (15:85 v/v) at a flow rate of 0.60 mL/min on a Zorbax SB C18 (50 × 4.6 mm, 5 µm) column. A linear response function was established for the range of concentrations 50–15,000 pg/mL (r > 0.998) for LAC. The current developed method has negligible matrix effect and is free from unwanted adducts and clusters which are formed owing to system such as solvent or mobile phase. The developed assay method was applied to an oral pharmacokinetic study in humans and successfully characterized the pharmacokinetic data up to 72 h. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
PCK3145 is a synthetic peptide, derived from the Prostate Secreted Protein 94 (PSP94), with promising in vitro and animal in vivo results in prostate cancer. The aim of the present study was to develop and validate a fast and robust ultra‐high‐performance liquid chromatography with ultraviolet detection for the determination of PCK3145 in human plasma which would be suitable for the assessment of PCK3145 stability to proteolytic degradation. Following protein precipitation, chromatographic separation was carried out on an Aeris Peptide C18 column with mobile phase consisting of acetonitrile–water at a flow‐rate of 0.50 mL/min. The calibration curve was linear over the range 0.50–20.00 μg/mL. Intra‐ and inter‐day percentage relative standard deviation and relative error were ≤10%. The limit of detection and the lower limit of quantification were 0.15 and 0.50 μg/mL, respectively. Recovery of PCK3145 from human plasma was ≥96%. The peptide presented high stability in whole blood and in human plasma (>98% intact peptide after 24 h incubation at 37°C in human plasma), which represents a distinctive advantage in the therapeutic use of the compound. This is the first validated UHPLC method for the determination of PCK3145 reported, and it was successfully applied in the study of the proteolytic stability of PCK3145 in human plasma ex vivo. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
A newly developed LC—APCI mass spectrometric method is described for human plasma determination of atovaquone using lapachol internal standard. A single‐step protein precipitation technique for plasma extraction of atovaquone achieving mean recovery of 94.17% (CV 8%) without compromising sensitivity (limit of quantitation 50.3 ng/mL) or linearity (50.3 ng/mL—23924.6 ng/mL) is delineated in this paper. Heated nebulizer in negative multiple reaction monitoring mode was employed with transitions m/z 365.2 → m/z 337.1 and m/z 240.9 → m/z 185.7 for atovaquone and lapachol respectively in this liquid chromatographic–tandem mass spectrometric method. Excellent chromatographic separation on a Synergi 4 μ Polar‐RP 80A (150 × 2.0 mm) column, using 100 μL of plasma extraction volume along with 10 μL of injection load, completing analysis run‐time within 2.5 min, highlights this simple yet unique bioanalytical method. The developed method can be successfully applied to pharmacokinetic studies on atovaquone suspension administered in healthy volunteers or HIV‐infected patients. Moreover full method validation results not published before are presented and discussed in detail for the first time in this article. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
A sensitive and high‐throughput LC‐MS/MS method has been developed and validated for the combined determination of esomeprazole and naproxen in human plasma with ibuprofen as internal standard. Solid‐phase extraction was used to extract both analytes and internal standard from human plasma. Chromatographic separation was achieved in 4.0 min on XBridge C18 column using acetonitrile–25 mM ammonium formate (70:30, v/v) as mobile phase. Mass detection was achieved by ESI/MS/MS in negative ion mode, monitoring at m/z 344.19 → 194.12, 229.12 → 169.05 and 205.13 → 161.07 for esomeprazole, naproxen and IS, respectively. The calibration curves were linear from 3.00 to 700.02 ng/mL for esomeprazole and 0.50 to 150.08 ng/mL for naproxen. The intra‐ and inter‐batch precision and accuracy across four quality control levels met established criteria of US Food and Drug Administration guidelines. The assay is suitable for measuring accurate esomeprazole and naproxen plasma concentrations in human bioequivalence study following combined administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A simple and high sensitive ultra‐high‐performance liquid chromatography tandem mass spectrometry method for the determination of fludrocortisone in human plasma was developed and validated as per guidelines. The analyte and internal standard (IS), fludrocortisone‐d5, were extracted from human plasma via liquid–liquid extraction using tert‐butyl methyl ether. The chromatographic separation was achieved on a Chromolith RP18e column using a mixture of acetonitrile and 2 mm ammonium formate (70:30, v/v) as the mobile phase at a flow rate of 0.7 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique, operating in multiple reaction monitoring and positive ion mode. The precursors to product ion transitions monitored for fludrocortisone and IS were m/z 381.2 → 343.2 and 386.2 → 348.4, respectively. The assay was validated with linear range of 40–3000 pg/mL. The intra‐ and inter‐day precisions (relative standard deviation) were within 0.49–7.13 and 0.83–5.87%, respectively. The proposed method was successfully applied to pharmacokinetic studies in humans. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
Summary Elevated plasma homocysteine is, a known risk factor in arteriosclerotic vascular disease. To measure homocysteine in a large number of samples, we have developed a rapid, simple, robust and inexpensive reversed-phase HPLC method for routine analysis. Mercaptopro-pionylglycine was used as the internal standard and an external calibration in plasma was performed. Improvement was achieved by the use of gradient elution (using a sodium acetate buffer and methanol) resulting in a higher number of samples analyzed per day. Plasma samples were reduced with tributylphosphine and the proteins were precipitated with perchloric acid before addition of internal standard. The analytes were derivatized by use of 7-fluorobenzofurazone-4-sulfonic acid ammonium salt. For calibration human plasma was spiked with nine different concentrations of homocysteine (range 2–50 μmol L−1). The inter-assay precision of replicate (n=29) analysis of the concentration of homocysteine in a sample of pooled plasma was 3.0%. The limit of detection, defined as three times the signal-to-noise ratio, was 0.25 μmol L−1. The linearity of the assay was confirmed for a plasma concentration range of 2–2000 μmol L−1. The variation of duplicate analyses of 842 plasma samples was 2.6±1.7%.  相似文献   

15.
A readily applicable method was developed to determine the concentration level of zaltoprofen, a non‐steroidal antiinflammatory drug from the propionic acid family, in human plasma. This method is based on manual‐shaking‐assisted dispersive liquid–liquid microextraction coupled with liquid chromatography with ultraviolet detection. Factors affecting the extraction efficiency were screened and optimized by experimental design using fractional factorial and central composite designs, respectively. Optimal conditions were: 220 μL of C2H4Cl2 (extraction solvent), 5 mL of 3.75% w/v NaCl aqueous solution at pH 2.0, and manual shaking for 13 s (65 times). The resulting extraction method yielded a reasonable enrichment factor of 18.0 (±0.6, = 3) and extraction recovery of 86.0% (±3.3%, = 3). The established method was validated for selectivity, linearity, precision, accuracy, matrix effect, recovery, dilution integrity, and stability, and it met the acceptable criteria for all of the tested parameters. Specifically, the method was linear in the range of 0.16–50.0 mg/L, precise (< 8.8% RSD), accurate (–7.5–5.6% deviation), and showed negligible matrix effects (96.1–106.4%) with high absolute recovery (94.5–97.7%). Compared with previous methods involving labor‐intensive liquid–liquid extraction or non‐specific protein precipitation, our method allows the simple, rapid, and efficient determination of zaltoprofen using the most affordable analytical instrument, liquid chromatography with ultraviolet detection.  相似文献   

16.
A simple, rapid and sensitive high‐performance liquid chromatography (HPLC)‐based method with ultraviolet detection was developed for the quantitation of nilotinib, a tyrosine kinase inhibitor, in human plasma. Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% KH2PO4 (pH2.5)–acetonitrile–methanol (55:25:20, v/v/v) on a Capcell Pak MG II column (250 × 4.6 mm) at a flow rate of 0.5 mL/min and optical measurement at 250 nm. Analysis required only 100 μL of plasma and involved a rapid and simple solid‐phase extraction with an Oasis HLB cartridge, which gave recoveries from 72 to 78% for nilotinib and from 74 to 76% for dasatinib. The lower limit of quantification for nilotinib was 10 ng/mL. The linear range of this assay was between 10 and 5000 ng/mL (r2 > 0.9992 for the regression line). Intra‐ and inter‐day coefficients of variation were less than 10.0% and accuracies were within 10.4% over the linear range. Our results indicate that this method is applicable to the monitoring of plasma levels of nilotinib in a clinical setting. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
Summary Samples were extracted with dichloromethane and the organic layer evaporated to dryness. The residue was dissolved in methanol, and 10 μl aliquot injected onto the column. Tolbutamide was used as the internal standard for chlorpropamide. The UV detector response was linear over the range 0–200 μg ml−1 with a correlation coefficient of 0.999; detection limit: 0.002 μg ml−1. Within-day and between-day assay variation was generally ≤7%. No interference from endogenous constituents was observed. The utility of the method was demonstrated by determining chlorpropamide in samples from six healthy volunteers following a single oral dose of 250 mg. The procedure is simple and requires small volumes of plasma.  相似文献   

18.
Ibrutinib is an oral inhibitor of Bruton tyrosine kinase, which is one of the key drugs used for the treatment of chronic lymphocytic leukemia and mantle cell lymphoma. In this study, we aimed to develop a simple method for determining plasma ibrutinib concentration. The analysis required extraction of a 200 μL plasma sample and precipitation of proteins using solid‐phase extraction. Ibrutinib and nilotinib, which was used as an internal standard, were separated using high‐performance liquid chromatography (HPLC) using a mobile phase of acetonitrile–0.5% monopotassium phosphate (KH2PO4, pH 3.0; 52:48, v/v) on a Capcell Pack C18 MG II (250 × 4.6 mm) monitored at 260 nm, at a flow rate of 1.0 mL/min. The calibration curve was linear at the plasma concentration range of 10–500 ng/mL with a coefficient of determination (r2) of 0.9999. The coefficients of intra‐day and inter‐day validation were 4.0–6.6 and 2.6–7.7%, respectively. The assay accuracy was ?4.4–8.6%, and the recovery was >84%. This HPLC method coupled with ultraviolet (UV) detection for determining ibrutinib plasma concentration has several advantages such as simplicity and applicability to routine therapeutic drug monitoring at hospital laboratories.  相似文献   

19.
A highly sensitive, rapid assay method has been developed and validated for the estimation of bicalutamide in mouse plasma using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the negative‐ion mode. The assay procedure involves extraction of bicalutamide and tolbutamide (internal standard, IS) from mouse plasma with a simple protein precipitation method. Chromatographic separation was achieved using an isocratic mobile phase (0.2% formic acid:acetonitrile, 35:65, v/v) at a flow rate of 0.5 mL/min on an Atlantis dC18 column (maintained at 40 ± 1°C) with a total run time of 3.0 min. The MS/MS ion transitions monitored were m/z 428.9 → 254.7 for bicalutamide and m/z 269.0 → 169.6 for IS. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 1.04 ng/mL and the linearity range extended from 1.04 to 1877 ng/mL. The intra‐ and inter‐day precisions were in the ranges of 0.49–4.68 and 2.62–4.15, respectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
Linezolid is an antimicrobial agent for the treatment of multiresistant Gram‐positive infections. A practical high‐performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o‐ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5–50 µg/mL using a 200 μL sample volume. The intra‐ and interday precisions were all <6.44% for plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid–liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号