首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A capillary electrophoresis (CE) with UV absorption detection method is described for the simultaneous determination of glufosinate, glyphosate, and aminomethylphosphoric acid. The 9‐fluorenylmethyl chloroformate (FMOC‐Cl) was used for precolumn derivatization of the non‐absorbing herbicides. The three analytes were separated by CE in 9 min with 25 mM borate buffer at pH 9, followed by detection with a UV detector at 260 nm. We demonstrate how the detection limit can be enhanced by using acetonitrile‐salt mixtures. With acetonitrile‐salt mixtures, the limit of detection (LOD) was in the 10?7 M range. Linearity of more than two orders of magnitude was generally obtained. Precisions of migration times and peak areas were less than 0.9% and 7.5%, respectively. The applicabilities of the method for the analysis of ground water and lake water were examined.  相似文献   

2.
Rapid and direct online preconcentration followed by CE with capacitively coupled contactless conductivity detection (CE‐C4D) is evaluated as a new approach for the determination of glyphosate, glufosinate (GLUF), and aminophosphonic acid (AMPA) in drinking water. Two online preconcentration techniques, namely large volume sample stacking without polarity switching and field‐enhanced sample injection, coupled with CE‐C4D were successfully developed and optimized. Under optimized conditions, LODs in the range of 0.01–0.1 μM (1.7–11.1 μg/L) and sensitivity enhancements of 48‐ to 53‐fold were achieved with the large volume sample stacking‐CE‐C4D method. By performing the field‐enhanced sample injection‐CE‐C4D procedure, excellent LODs down to 0.0005–0.02 μM (0.1–2.2 μg/L) as well as sensitivity enhancements of up to 245‐ to 1002‐fold were obtained. Both techniques showed satisfactory reproducibility with RSDs of peak height of better than 10%. The newly established approaches were successfully applied to the analysis of glyphosate, glufosinate, and aminophosphonic acid in spiked tap drinking water.  相似文献   

3.
A rapid and practical method for direct detection of the herbicides (glufosinate, bialaphos and glyphosate) in anion-exchange chromatography has been developed with integrated pulsed amperometric detection (IPAD). The electrochemical behavior of these herbicides showed catalytic currents based on the oxidation of amines in their structures. Waveform in IPAD was similar to that for amino acids, which exhibited adsorption/desorption catalytic features at gold electrode surface in alkaline solution. Under optimized conditions, detection limits (signal-to-noise ratio of 3) for glufosinate, bialaphos and glyphosate were 20, 65 and 50 ng ml(-1), respectively, with correlation coefficients of 0.995, 0.997 and 0.996 over concentration ranges of 0.1-45, 0.3-32 and 0.1-50 microg ml(-1), respectively. The relative standard deviations (n=5) were 1.7-3.0%. The present method was successfully applied to the determination of glyphosate in urine and serum.  相似文献   

4.
This paper describes a method for the sensitive and selective determination of glyphosate, glufosinate and aminomethylphosphonic acid (AMPA) residues in water and soil samples. The method involves a derivatization step with 9-fluorenylmethylchloroformate (FMOC) in borate buffer and detection based on liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS). In the case of water samples a volume of 10 mL was derivatized and then 4.3 mL of the derivatized mixture was directly injected in an on-line solid phase extraction (SPE)-LC-MS/MS system using an OASIS HLB cartridge column and a Discovery chromatographic column. Soil samples were firstly extracted with potassium hydroxide. After that, the aqueous extract was 10-fold diluted with water and 2 mL were derivatized. Then, 50 microL of the derivatized 10-fold diluted extract were injected into the LC-MS/MS system without pre-concentration into the SPE cartridge. The method has been validated in both ground and surface water by recovery studies with samples spiked at 50 and 500 ng/L, and also in soil samples, spiked at 0.05 and 0.5 mg/kg. In water samples, the mean recovery values ranged from 89 to 106% for glyphosate (RSD <9%), from 97 to 116% for AMPA (RSD < 10%), and from 72 to 88% in the case of glufosinate (RSD < 12%). Regarding soil samples, the mean recovery values ranged from 90 to 92% for glyphosate (RSD <7%), from 88 to 89% for AMPA (RSD <5%) and from 83 to 86% for glufosinate (RSD <6%). Limits of quantification for all the three compounds were 50 ng/L and 0.05 mg/kg in water and soil, respectively, with limits of detection as low as 5 ng/L, in water, and 5 microg/kg, in soil. The use of labelled glyphosate as internal standard allowed improving the recovery and precision for glyphosate and AMPA, while it was not efficient for glufosinate, that was quantified by external standards calibration. The method developed has been applied to the determination of these compounds in real water and soil samples from different areas. All the detections were confirmed by acquiring two transitions for each compound.  相似文献   

5.
何书海  曹小聪  吴海军  李腾崖  张鸣珊  梁焱  陈表娟 《色谱》2019,37(11):1179-1184
建立了一种简便、直接进样的超高效液相色谱-三重四极杆质谱法(UPLC-MS/MS)快速测定环境水样中草甘膦、氨甲基膦酸、草铵膦及乙烯利的残留。环境水样经0.22 μm滤膜过滤或冷冻离心去除杂质后,滤液无需衍生化直接进行定量分析。4种农药通过Metrosep A Supp 5柱(150 mm×4.0 mm,5 μm)分离,以碳酸氢铵-氨水溶液为流动相进行梯度洗脱,在负离子模式下以MRM方式进行检测。结果表明,4种农药在0.50~50.0 μg/L范围内相关系数(r)均大于0.999,线性关系良好,方法检出限为0.05~0.09 μg/L。实际水样在低、中、高3种加标浓度水平下,回收率分别为76.3%~108%、83.0%~107%和87.0%~105%,相对标准偏差分别为2.0%~12.3%、2.4%~5.6%和2.7%~6.8%。使用该方法对海南省34个水样进行测定,其中30个饮用水源地水样中均未检出4种农药,槟榔园附近3个水样均检出草甘膦和氨甲基膦酸,香蕉园附近的1个水样检出草铵膦和氨甲基膦酸。与传统的衍生化方法比较,该方法操作简便,重现性好,准确性高,不受基体干扰,适用于环境水样中草甘膦、氨甲基膦酸、草铵膦及乙烯利的残留检测。  相似文献   

6.
We developed a rapid and sensitive method using in-capillary derivatization and laser-induced fluorescence (LIF) detection for the fully automated analysis of organophosphorus pesticides (OPPs), including glufosinate, aminomethylphosphonic acid (AMPA) and glyphosate by micellar electrokinetic chromatography (MEKC). The potential of 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) as in-capillary derivatization reagent is described for the first time. The unique feature of this MEKC method is the capillary being used as a small reaction chamber. In in-capillary derivatization, the sample and reagent solutions were injected directly into the capillary by tandem mode, followed by an electrokinetic step to enhance the mixing efficiency of analytes and reagent plugs in accordance with their different electrophoretic mobilities. Standing a specified time for reaction, the derivatives were then immediately separated and determined. Careful optimization of the derivatization and separation conditions allowed the determination of glufosinate, AMPA and glyphosate with detection limits of 2.8, 3.6 and 32.2 ng/mL, respectively. These detection limits were comparable to those of 1.4, 1.9 and 23.8 ng/mL obtained from conventional pre-capillary derivatization. Furthermore, repeatability better than 0.40% for migration time and 3.4% for peak area, as well as shorter migration time, was obtained. The method was successfully applied to the analysis of spiked river water sample with satisfactory results.  相似文献   

7.
The paper presents the application of pre-chromatographic derivatisation reaction of aminophosphonic acids (glyphosate and glufosinate) with phenylisothiocyanate in thin-layer chromatography (TLC). Silica gel as stationary phase and a mixture of methanol–water–diethyl ether (2:1:1, v/v/v) and ethanol–water–diethyl ether (4:1:2, v/v/v) were used as the mobile phase, respectively. Detection was performed by spraying TLC plates with a freshly prepared mixture of sodium azide (1%), starch solution (1% for glyphosate and 2% for glufosinate), and potassium iodide (1.0 × 10–2 mol L?1) adjusted to pH 6.0 and exposed to iodine vapour for 15 s. Both glyphosate and glufosinate as phenylthiocarbamates (PTC-derivatives) were visible as white spots against a violet background which were converted into chromatograms using TLSee software. The calibration curves for glyphosate and glufosinate were within the ranges of 8.45–84.5 ng and 1.98–79.2 ng per spot, respectively. The limits of detection and quantification for glyphosate were at a level of 4 and 8.45 ng per spot, and for glufosinate were 0.99 and 1.78 ng per spot, respectively. The proposed method was successfully used in the determination of aminophosphonic acids in spiked plants samples.  相似文献   

8.
建立了一种梯度洗脱-电导抑制-离子色谱同时测定4种强极性农药的方法.通过对淋洗液及浓度、色谱柱、柱温、进样量等条件的优化,得到最佳检测条件:色谱柱为IonPac AS11-HC分析柱及IonPac AG11-HC保护柱,柱温33℃,进样量50μL,RFIC系统的淋洗液自动发生器在线产生的KOH作为淋洗液,梯度洗脱,淋洗...  相似文献   

9.
The potential of capillary electrophoresis combined with mass spectrometry for the simultaneous determination of two herbicides (glyphosate and glufosinate) and their metabolites (aminomethylphosphonic acid and methylphosphinicopropionic acid) as the native species is demonstrated utilising a simple microelectrospray interface. The interface uses the voltage applied to the CE capillary to drive separation and generate the electrospray, avoiding sample dilution associated with the use of a sheath liquid interface. The chemistry of the internal walls of the capillary has a marked influence on peak shape, and appropriate choice is essential to successful operation of the interface. A linear polyacrylamide coated capillary, which has no electroosmotic flow, gave best reproducibility, with precision of migration time and peak area in the range 1-2 and 7-12% RSD, respectively, for the four analytes. Limits of detection, low-pg on-column, are substantially better than for previous methods and calibration curves over the range 1-100 microM have R2 values greater than 0.97. The observed concentration limit of detection for glyphosate in water is 1 microM and for a water-acetone extract of wheat is 2.5 microM, allowing the underivatised herbicide to be detected at 10% of the maximum residue limit in wheat.  相似文献   

10.
In this work, the potential of inductively coupled plasma-mass spectrometry (ICP-MS) coupled to capillary electrophoresis (CE) to determine organophosphorus pesticides (OPPs) is demonstrated. Element specific detection of (31)P with ICP-MS is performed for the detection of OPPs. Three common OPPs, including glyphosate, glufosinate, and aminomethylphosphonic acid (AMPA), were analyzed by CE-ICP-MS to demonstrate its applicability for the analysis of OPPs. The advantages of using ICP-MS with respect to other common detectors, such as flame photometric detection (FPD), for CE analysis of OPPs are shown. Additionally, different CE separation conditions were studied to achieve complete baseline separation of the pesticide compounds in short migration times. Two CE buffer systems were evaluated for the separation of OPPs using ICP-MS detection. A buffer solution containing 40 mmol.L(-1) ammonium acetate at pH 9.0 and an applied voltage of +20 kV were finally selected leading to a separation time of 10.0 min. Both migration time and area relative standard deviations (%RSD) were evaluated and their respective values were in the intervals of 1.1-3.3% and 2.7-5.3%. Detection limits obtained with the CE-ICP-MS system were in the range of 0.11-0.19 mg.L(-1) (as compound) yielding an enhancement of 130- to 230-fold with respect to FPD. The proposed methodology was finally applied for the determination of the OPPs mentioned above in natural river water samples.  相似文献   

11.
A novel magnetic metal‐organic framework composite was prepared by a self‐assembly approach. The material properties were characterized by Fourier‐transform infrared spectroscopy, vibrating sample magnetometry, thermogravimetry and differential thermogravimetric analysis, and X‐photoelectron spectroscopy. Then, the as‐prepared material was used as an adsorbent and indicated great enrichment ability toward glyphosate, glufosinate, bialaphos, and their main metabolites aminomethylphosphonic acid and 3‐methylphosphinicopropionic acid. Based on this, an efficient magnetic solid‐phase extraction method combined with ultra high performance liquid chromatography with high‐resolution mass spectrometry for the pretreatment and determination of five target compounds in environmental waters was established. Parameters that could impact on the adsorption performance had been studied in detail. The proposed method was successfully applied for the simultaneous determination of glyphosate, glufosinate, bialaphos, and their main metabolites aminomethylphosphonic acid and 3‐methylphosphinicopropionic acid in environmental water with recoveries in range of 86.2–104.6% with relative standard deviations less than 10%. Desired linearity was achieved varying from 1 to 100 μg/L for five target analytes, respectively. The limits of detection were between 0.01 and 0.03 μg/L.  相似文献   

12.
曹丽伟  梁丝柳  谭小芳  孟建新 《色谱》2012,30(12):1295-1300
建立了一种快速、有效的毛细管电泳分离-激光诱导荧光检测有机磷除草剂草甘膦、草胺膦和草甘膦的代谢物氨甲基膦酸的方法。将荧光衍生试剂5-(4, 6-二氯三嗪基)氨基荧光素(DTAF)成功用于衍生上述3种化合物。最佳衍生条件: DTAF的浓度为1.0 μmol/L,以50 mmol/L硼酸(pH 9.5)作为缓冲溶液,在30 ℃下反应40 min。以pH 9.5的30 mmol/L硼酸缓冲溶液(含15 mmol/L Brij-35)作为电泳背景电解质,3种衍生物得到基线分离。在优化的条件下,草甘膦、草胺膦、氨甲基膦酸的检出限分别为3.21、6.14和1.99 ng/kg。将该方法应用于环境水样和土壤中除草剂及代谢物的测定,回收率为91.3%~106.0%。该方法准确、灵敏,可满足环境样品中有机磷农药及其代谢物残留的检测要求。  相似文献   

13.
Analysing herbicides in soil is a complex issue that needs validation and optimization of existing methods. An extraction and analysis method was developed to assess concentrations of glyphosate, glufosinate and aminomethylphophonic acid (AMPA) in field soil samples. After testing extractions by accelerated solvent extraction and ultrasonic extraction, agitation was selected with the best recoveries. Water was preferred as solvent extraction because it resulted in a cleaner chromatogram with fewer impurities than was the case with alkaline solvents. Analysis was performed by FMOC pre-column derivatization followed by high-performance liquid chromatography (HPLC) on a 300 mm C(18) column which permitted enhanced separation and sensitivity than a 250 mm C(18) column and increased resistance than the NH(2) column for soil samples. This extraction and analysis method allowing a minimum of steps before the injection in the HPLC with fluorescence detection is efficient and sensitive for a clay-loamy soil with detection limits of 103 μg kg(-1) for glyphosate, 15 μg kg(-1) for glufosinate and 16 μg kg(-1) for AMPA in soil samples.  相似文献   

14.
We developed a simple and rapid method for the simultaneous determination of phosphorus-containing amino acid herbicides (glyphosate, glufosinate, bialaphos) and their major metabolites, aminomethylphosphonic acid (AMPA) and 3-methylphosphinicopropionic acid (MPPA), in human serum. Serum samples were filtrated through an ultrafiltration membrane to remove proteins. The filtrate was then washed with chloroform, and injected into a liquid chromatography-tandem mass spectrometry (LC-MS/MS) system. Chromatographic separation was achieved on a hydrophilic interaction chromatography (HILIC) column. Determination of the target herbicides and metabolites was successfully carried out without derivatization or solid phase extraction (SPE) cartridge clean-up. The recoveries of these compounds, added to human serum at 0.2μg/mL, ranged from 94% to 108%, and the relative standard deviations (RSDs) were within 5.9%. The limits of detection (LODs) were 0.01μg/mL for MPPA, 0.02μg/mL for AMPA, 0.03μg/mL for both glyphosate and glufosinate, and 0.07μg/mL for bialaphos, respectively.  相似文献   

15.
建立了一种非衍生化高效液相色谱-串联质谱快速检测生物体液中草甘膦、草铵膦及其代谢物等8种极性农药的方法。8种极性农药经Metrosep A Supp 5阴离子色谱柱(150 mm×4.0 mm,5μm)分离,以纯水-200 mmol/L碳酸氢铵溶液(含0.1%氨水)为流动相进行梯度洗脱,负离子多反应监测(MRM)模式进行检测。实验结果表明,8种极性农药在0.5~50 ng/mL范围内线性关系良好(r2>0.99),检出限(S/N≥3)为0.08~0.3 ng/mL,定量下限(S/N≥10)为0.3~1 ng/mL。方法的基质效应为86.5%~106%,目标化合物的回收率为81.5%~114%,日内相对标准偏差(RSD)为0.30%~2.8%,日间RSD为0.50%~5.3%。该方法无需复杂的衍生化过程,简便快速、灵敏度高、稳定性好,适用于生物体液中8种极性农药的检测。  相似文献   

16.
Analysis of the broad-spectrum herbicide glyphosate and its related compounds is quite challenging. Tedious and time-consuming derivatization is often required for these substances due to their high polarity, high water solubility, low volatility and molecular structure which lacks either a chromophore or fluorophore. A novel liquid chromatography/tandem mass spectrometry (LC/MS–MS) method has been developed for the determination of glyphosate, aminomethylphosphonic acid (AMPA) and glufosinate using a reversed-phase and weak anion-exchange mixed-mode Acclaim® WAX-1 column. Aqueous environmental samples are directly injected and analyzed in 12 min with no sample concentration or derivatization steps. Two multiple reaction monitoring (MRM) channels are monitored in the method for each target compound to achieve true positive identification, and 13C,15N-glyphosate is used as an internal standard to carry out isotope dilution mass spectrometric (IDMS) measurement for glyphosate. The instrument detection limits (IDLs) for glyphosate, AMPA and glufosinate are 1, 2 and 0.9 μg/L, respectively. Linearity of the detector response with a minimum coefficient of determination (R2) value (R2 > 0.995) was demonstrated in the range of ∼10 to 103 μg/L for each analytes. Spiked drinking water, surface water and groundwater samples were analyzed using this method and the average recoveries of analytes in three matrices ranged from 77.0 to 102%, 62.1 to 101%, 66.1 to 93.7% while relative standard deviation ranged from 6.3 to 10.2%, 2.7 to 14.8%, 2.9 to 10.7%, respectively. Factors that may affect method performance, such as metal ions, sample preservation, and storage time, are also discussed.  相似文献   

17.
Molina M  Silva M 《Electrophoresis》2001,22(6):1175-1181
The potential of micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection for the separation and determination of phosphorus-containing amino acid-herbicides (glufosinate and glyphosate), and aminomethylphosphonic acid (the major metabolite of glyphosate), involving derivatization with fluorescein isothiocyanate (FITC) isomer I, was investigated. Different variables that affect derivatization (pH, FITC concentration, time and temperature) and separation (pH and concentration of the buffer, kind and concentration of surfactants and applied voltage) were studied. The analysis was conducted within about 8 min and the use of the nonionic surfactant Triton X-100 improved the selectivity, thus indirectly enhancing sensitivity by shifting of the interfering peaks of the FITC excess. Dynamic ranges of 2.0-3,000 microg/L, limits of detection at microgram or submicrogram-per-liter level, and relative standard deviations from 4.7 to 6.4% were obtained. The ensuing method--nonionic surfactant MEKC-- is a useful choice for the determination of these herbicides as it provides limits of detection similar or lower than those reported by existing chromatographic alternatives without the use of an additional preconcentration technique such as solid-phase extraction. The separation of a mixture of nine FITC-derivatized amino acids, selected as target compounds, was also carried out to assess the discrimination power of the nonionic surfactant MEKC method for the analysis of closely related anionic analytes.  相似文献   

18.
A sensitive and robust analytical method for the quantification of glyphosate, aminomethylphosphonic acid (AMPA) and glufosinate in natural water has been developed on the basis of a derivatization with 9-fluorenylmethylchloroformate (FMOC-Cl), solid-phase extraction (SPE) and liquid chromatography followed by electrospray tandem mass spectrometry (LC-ESI-MS/MS). In order to maximize sensitivity, the derivatization was optimized regarding organic solvent content, amount of FMOC-Cl and reaction time. At an acetonitrile content of 10% a derivatization yield of 100% was reached within two hours in groundwater and surface water samples. After a twofold dilution the low acetonitrile content allowed solid-phase extraction of a sample of originally 80 mL over 200 mg Strata-X cartridges. In order to decrease the load of the LC column and mass spectrometer with derivatization by-products (e.g., 9-fluorenylmethanol FMOC-OH), a rinsing step was performed for the SPE cartridge with dichloromethane. Acidification of the sample and addition of EDTA was used to minimize complexation of the target compounds with metal ions in environmental samples. Due to the large sample volume and the complete FMOC-OH removal, limits of quantification of 0.7 ng/L, 0.8 ng/L and 2.3 ng/L were achieved in surface water for glyphosate, AMPA and glufosinate, respectively. The limits of detection were as low as 0.2 ng/L, 0.2 ng/L and 0.6 ng/L for glyphosate, AMPA and glufosinate, respectively. Surface water and ground water samples spiked at 2 ng/L showed recoveries of 91–107%. Figure LC-MS/MS chromatogram of a water sample from a remote alpine region spiked at 1 ng/L  相似文献   

19.
A surface-sampling technique of liquid extraction surface analysis (LESA) was in-line coupled with capillary electrophoresis (CE) to expand the specimen types for CE to solid surfaces. The new direct surface analysis method of LESA–CE was applied to the determination of organophosphorus pesticides, including glufosinate-ammonium, aminomethylphosphonic acid, and glyphosate on the external surface of a fruit such as apple. Without any sample pretreatment, the analytes sprayed on the surface of a half apple were directly extracted into a liquid microjunction formed by dispensing the extractant from the inlet tip of a separation capillary. After extraction, the analytes were derivatized in-capillary with a fluorophore 4-fluoro-7-nitro-2,1,3-benzoxadiazole and analyzed with CE-laser induced fluorescence (LIF). The limits of detection for glufosinate-ammonium, aminomethylphosphonic acid, and glyphosate were 2.5, 1, and 10 ppb, respectively, which are at least 20 times lower than the tolerance limits established by the U.S. Environmental Protection Agency. Thus, we demonstrated that LESA–CE is a quite sensitive and convenient method to determine analytes on a solid surface avoiding the dilution from sample pretreatment procedures including homogenization of a bulk sample.  相似文献   

20.

An electrospray condensation nucleation light scattering detector (ESI-CNLSD) was coupled with capillary electrophoresis (CE) for analysis of glyphosate, a chemical of agricultural interest, which is otherwise difficult to detect owing to its lack of chromophores or fluorophores. To reduce the absorption of glyphosate on the CE capillary and to reduce the separation time, an N-cetyltrimethylammonium bromide (CTAB) pre-rinsing CE method was developed here. The protocol consisted of 15 min pre-rinsing of the capillary before analysis with CTAB solution and 5 min with ammonium acetate buffer at pH 2.8. The capillary inner wall coating established by this treatment lasted up to 10 h without bleeding to interfere with CNLSD signal. Calibration data were linear over two orders of magnitude, the instrument detection limit was 0.06 µg/mL and the method detection limit was 0.2 µg/mL. The method was applied to the analysis of local (rural area) lake water and commercial herbicide samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号