首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A highly sensitive procedure to detect multiple pesticides at trace levels in foods is presented. Initially a comparative study between capillary electrophoresis (CE)-UV and CE-mass spectrometry (MS) is carried out analyzing five pesticides not studied up to now (pyrimethanil, pyrifenox, cyprodinil, cyromazine, and pirimicarb). The comparison between CE-UV and CE-MS is established in terms of separation efficiency, speed of analysis, reproducibility, and sensitivity. A good separation of these compounds is achieved by both techniques using a volatile aqueous buffer containing 0.3 M ammonium acetate/acetic acid at pH 4. Time analysis reproducibility is studied for the same day (n = 5) and three different days (n = 15), showing no significant differences between CE-UV and CE-MS. The study on peak areas reproducibility shows a slightly worse reproducibility for CE-MS compared with CE-UV. The best limit of detection (LOD) that can be achieved for these pesticides using CE-UV was 0.6 microg/mL. CE-MS provides LODs one order of magnitude better than CE-UV. Chemometrics are used to optimize the multiple parameters that play a role in solid-phase microextraction (SPME) and CE-MS analysis (e.g., extraction and desorption times, nebulizer pressure, dry gas flow, dry gas temperature, percentage of organic solvent and acid in the sheath liquid, etc.). The combined use of chemometrics and SPME-CE-MS clearly improves the LODs that can be achieved allowing the detection of pesticides at concentrations down to 15 ng/mL. The usefulness of this approach is demonstrated detecting multiple pesticides in different food samples as grapes and orange juice in a single run. The concentrations detected are below the maximum residue limits (MRLs) permitted for these pesticides in foods corroborating the value of our approach. This work demonstrates, to our knowledge for the first time, the good possibilities of the combined use of SPME-CE-MS and chemometrics.  相似文献   

2.
Font G  Ruiz MJ  Fernández M  Picó Y 《Electrophoresis》2008,29(10):2059-2078
Food contamination continues to be a serious problem around the world. Surveillance of chemical contaminants in foods is important not only for public health but also because of the negative economic impact of contamination. From the analytical perspective, analysis of contaminants in food is an extremely challenging area. There is a wide variety of questions, ranging from the quantification of extremely low levels of individual components to the detailed assessment and evaluation of the analytical technique possibilities. This review considers the applications of CE coupled to MS detection (CE-MS) for the analysis of organic contaminants in food. Analytical information on sample concentration techniques, as well as on the CE separation conditions and recoveries obtained from water and food are provided. Different sections include several fields of application, such as pesticides, drug residues, or toxic formed during food processing in different matrices. A number of tables report a comprehensive listing of CE-MS applications. As a result, this work presents an update overview on the principal application of CE-MS together with a discussion of their main advantages and drawbacks, and an outline of future trends on analysis of organic contaminants.  相似文献   

3.
The analysis of food components using capillary electromigration methods is reviewed in this work. Papers that were published from February 2009 to February 2011 are included following the previous review by Herrero et al. (Electrophoresis, 2010, 31, 205-228). The analysis of amino acids, biogenic amines, peptides, proteins, DNAs, carbohydrates, phenols, polyphenols, pigments, toxins, pesticides, vitamins, additives, small organic and inorganic ions and other compounds found in foods and beverages are reviewed, as well as those applications of CE for monitoring food interactions and food processing. The use of microchips, CE-MS and chiral-CE in food analysis is also discussed as well as other current and foreseen trends in this area of research including new developments in Foodomics.  相似文献   

4.
In this work, a new capillary electrophoresis-mass spectrometry (CE-MS) procedure is developed to analyze proteins in Spirulina platensis microalgae. It is demonstrated that a fine optimization of several separation parameters is essential in order to achieve suitable CE-MS analysis of these proteins in natural extracts from microalgae. Namely, optimization of the composition of the separation buffer, electrospray conditions, and washing routine between runs are required in order to obtain reliable and reproducible CE-MS analyses of the main proteins found in this microalga (namely, allophycocyanin-alpha chain, allophycocyanin-beta, c-phycocyanin-alpha, and c-phycocyanin-beta). The relative molecular mass of these biopolymers is determined using two different MS instruments coupled to CE, i.e., CE-ion trap-MS and CE-time of flight-MS (CE-TOF-MS). A comparison between the results obtained with both instruments is carried out. The high resolution of the TOF-MS enables the distinction of small modifications in proteins and, thus, a more accurate mass determination. Interestingly, molecular mass values obtained by both CE-MS procedures agree very well while these experimental values are only in partial agreement with those theoretically expected (i.e., genetically derived masses). Some protein modifications due to amino acids exchange induced by nucleotide codon mutations are proposed to explain this difference.  相似文献   

5.
Nanotechnology has emerged as one of the most innovative technologies and has the potential to improve food quality and safety. However, there are a few studies demonstrating that nanomaterials (NMs) are not inherently benign.This review highlights some current applications of NMs in food, food additives and food-contact materials, and reviews analytical approaches suitable to address food-safety issues related to nanotechnology.We start with a preliminary discussion on the current regulatory situation with respect to nanotechnology in relation to foods. We cover sample preparation, imaging techniques (e.g., electron microscopy, scanning electron microscopy and X-ray microscopy), separation methods (e.g., field-flow fractionation and chromatographic techniques) and detection or characterization techniques (e.g., light scattering, Raman spectroscopy and mass spectrometry). We also show the first applications of the analysis of NMs in food matrices.  相似文献   

6.
Simó C  Rizzi A  Barbas C  Cifuentes A 《Electrophoresis》2005,26(7-8):1432-1441
In this work, the development of a new chiral capillary electrophoresis-mass spectrometry (CE-MS) method to separate D- and L-amino acids is shown. On-line coupling between CE and MS is established through an electrospray-coaxial sheath flow interface. Enantiomer separation is achieved by using a cheap, nonvolatile, chiral selector as beta-cyclodextrin in the background electrolyte (BGE) together with a physically coated capillary that is aimed to prevent contamination of the electrospray. The capillary coating is simple and easy to obtain as it only requires flushing of the capillary with a polymer aqueous solution for 3 min. Optimization of CE parameters (pH of BGE, type and concentration of chiral selector, and capillary inner diameter) and electrospray-MS parameters (nature and flow rate of the sheath liquid, nebulizer pressure) is carried out. Two different derivatization protocols of amino acids using dansyl chloride (DNS) and fluorescein isothiocyanate (FITC) are compared in terms of MS sensitivity and chiral resolution. Under optimum CE-MS conditions it is observed that the MS sensitivity obtained for FITC- and DNS-amino acids is similar (with limit of detection (LOD) in the microM range, corresponding to amounts injected in the fmol range) while chiral resolution is better for FITC-amino acids. The optimized method is demonstrated to provide the simultaneous analysis of 15 selected amino acids (i.e., FITC-D/L-Asp, -Glu, -Ser, -Asn, -Ala, -Pro, -Arg, and FITC-gamma-aminobutyric acid (GABA) in a single chiral CE-MS run, corresponding to the main amino acids that can be found in orange. Moreover, as a result of the high resolution achieved, it is possible to detect down to 2% of D-Asp in the presence of 98% of L-Asp. The good possibilities of chiral CE-MS in food analysis are corroborated through the detection of the main amino acids in a commercial orange juice (i.e., FITC-L-Asp, -Glu, -Ser, -Asn, -Pro, -Arg, and the nonchiral FITC-GABA) as well as the determination of the fraudulent addition of synthetic amino acids (containing D- and L-forms) to a fresh orange juice.  相似文献   

7.
The application of capillary electrophoresis-mass spectrometry (CE-MS) to the analysis of compounds of concern to the aquaculture industry is reported. Two different approaches to coupling the CE column to an IonSpray atmospheric pressure ionization (API) interface, viz., a liquid-junction and a coaxial arrangement, are describe and compared with regard to ruggedness, ease of use, sensitivity and electrophoretic performance. The different injection modes used in three commercial capillary electrophoresis systems were also evaluated for their applicability to CE-MS. The use of CE-MS for the analysis of a variety of classes of antibiotics used in the fish aquaculture industry, such as the sulfonamides and their potentiators (e.g., trimethoprim), is demonstrated and was used to confirm the presence of these components in shellfish extracts at the low ppm level. CE-MS was also applied to the analysis of marine toxins such as saxitoxin and its analogues which are associated with paralytic shellfish poisoning, and also the toxins responsible for amnesic and diarrheic shellfish poisoning. Tandem mass spectrometry (MS-MS) was used to provide structural information on these analytes, and the ability to distinguish isomeric compounds based on their different migration and fragmentation characteristics using CE-MS-MS is demonstrated.  相似文献   

8.
The potential of capillary electrophoresis (CE) for the separation of peptides has been extensively demonstrated in the last decade. Their correct characterization and sequenciation is a difficult task that can be accomplished using CE-mass spectrometry (CE-MS). An important limitation of CE-MS is the buffer choice since it should provide an adequate CE separation without ruining the MS signal. In this work, a new strategy is used to help to solve this limitation based on the combination of two different methodologies. Namely, an ab initio semiempirical model that relates electrophoretic behavior of peptides to their sequence is first used to obtain in a fast and easy way adequate CE buffers compatible with MS analysis. Next, CE-MS is used to separate and characterize peptides via the determination of their relative molecular masses. The usefulness of this procedure is demonstrated analyzing in a single CE-MS run a group of 10 standard peptides of very different nature (i.e., relative molecular masses ranging from 132 to 1037 and isoelectric points ranging from 5.69 to 10.62). It is concluded that the use of this strategy can help to overcome the buffer limitation in CE-MS.  相似文献   

9.
魏波  马遥  田文哲  赵新颖  屈锋 《色谱》2021,39(6):559-566
该文为2020年毛细管电泳(capillary electrophoresis,CE)技术年度回顾.归纳总结了以"capillary electro-phoresis-mass spectrometry"或"capillary isoelectric focusing"或"micellar electrokinetic...  相似文献   

10.
Chiral electromigration methods in food analysis   总被引:1,自引:0,他引:1  
Simó C  Barbas C  Cifuentes A 《Electrophoresis》2003,24(15):2431-2441
This review article addresses the different chiral capillary electrophoretic methods that are being used for the study and characterization of foods and food compounds (e.g., amino acids, organic acids, sugars, pesticides). An updated overview, including works published till December 2002, on the principal applications of enantioselective procedures together with their main advantages and drawbacks in food analysis is provided. Some anticipated applications of chiral electromigration methods in food characterization are also discussed.  相似文献   

11.
Thermal analysis,state transitions and food quality   总被引:3,自引:0,他引:3  
Thermal properties of food systems are important in understanding relationships between food properties and changes in food quality. Concentrated food systems (low-moisture and frozen foods) are seldom in an equilibrium state and they tend to form amorphous, non-crystalline structures. Several glass transition-related changes in such foods affect stability, e.g., stickiness and caking of powders, crispness of snack foods and breakfast cereals, crystallisation of amorphous sugars, recrystallisation of gelatinised starch, ice formation and recrystallisation in frozen foods and rates of non-enzymatic browning and enzymatic reactions. Relationships between glass transition, water plasticisation and relaxation times can be shown in state diagrams. State diagrams are useful as stability or quality maps and in the control of rates of changes in food processing and storage.This revised version was published online in November 2005 with corrections to the Cover Date.  相似文献   

12.
This review provides an update of the state-of-the-art of CE-MS for metabolomic purposes, covering the scientific literature from July 2008 to June 2010. This review describes the different analytical aspects with respect to non-targeted and targeted metabolomics and the new technological developments used in CE-MS for metabolomics. The applicability of CE-MS in metabolomics research is illustrated by examples of the analysis of biomedical and clinical samples, and for bacterial and plant extracts. The relevant papers on CE-MS for metabolomics are comprehensively summarized in a table, including, e.g. information on sample type and pretreatment, and MS detection mode. Future considerations such as challenges for large-scale and (quantitative) clinical metabolomics studies and the use of sheathless interfacing and different ionization techniques are discussed.  相似文献   

13.
In recent years, the use of organic polymer monolithic capillary columns in separation science has gained popularity due to the fact that they are easy to fabricate and do not require retaining frits. These materials have been applied in different fields including foods, proteomics, and pharmaceuticals. The interest in food analysis still needs to develop in order to increase the sensitivity towards micro/nano‐scale food applications for food samples of < 5 μg (e.g., foodomics). In this regard, polymer monolithic capillary columns offer great separation capability in the food analytical separation science. We review the most important applications in food analysis using polymer monolithic capillary columns. In addition, several examples of the use of capillary separation methods combined with mass spectrometry detection in food analysis are summarized.  相似文献   

14.
Two important limitations still exist for the characterization of protein digests by capillary electrophoresis-mass spectrometry (CE-MS): (i) the buffer choice (i.e., the buffer must provide an adequate CE separation without ruining the MS signal), and (ii) the frequent generation of "unexpected" peptidic fragments during the enzymatic protein hydrolysis. In this work, a new approach is used to solve these difficulties, namely a theoretical model that relates the electrophoretic behavior of peptides to their sequence. The effectiveness of this procedure is demonstrated by the fast attainment of good CE-MS conditions for analyzing the peptides obtained from an enzymatic protein hydrolysate in a single run. This strategy can provide useful information for helping to characterize "unexpected" fragments from protein digests.  相似文献   

15.
Erny GL  Cifuentes A 《Electrophoresis》2007,28(9):1335-1344
It has been demonstrated that CE-MS is a very useful hyphenated technique for proteomic studies. However, the huge amount of data stored in a single CE-MS run makes it necessary to account with procedures able to extract all the relevant information made available by CE-MS. In this work, we present a new and easy approach capable of generating a simplified 2-D map from CE-MS raw data. This new approach provides the automatic detection and characterization of the most abundant ions from the CE-MS data including their mass-to-charge (m/z) values, ion intensities and analysis times. It is demonstrated that visualization of CE-MS data in this simplified 2-D format allows: (i) an easy and simultaneous visual inspection of large datasets, (ii) an immediate perception of relevant differences in closely related samples, (iii) a rapid monitoring of data quality levels in different samples, and (iv) a fast discrimination between comigrating polypeptides and ESI-MS fragmentation ions. The strategy proposed in this work does not rely on an excellent mass accuracy for peak detection and filtering, since MS values obtained from an IT analyzer are used. Moreover, the methodology developed works directly with the CE-MS raw data, without interference by the user, giving simultaneously a simplified 2-D map and a much easier and more complete data evaluation. Besides, this procedure can easily be implemented in any CE-MS laboratory. The usefulness of this approach is validated by studying the very similar trypsin digests from bovine, rabbit and horse cytochrome c. It is demonstrated that this simplified 2-D approach allows specific markers for each species to be obtained in a fast and simple way.  相似文献   

16.
A new physically adsorbed capillary coating for capillary electrophoresis-mass spectrometry (CE-MS) of basic proteins is presented, which is easily obtained by flushing the capillary with a polymer aqueous solution for two min. This coating significantly reduces the electrostatic adsorption of a group of basic proteins (i.e., cytochrome c, lysozyme, and ribonuclease A) onto the capillary wall allowing their analysis by CE-MS. The coating protocol is compatible with electrospray inonization (ESI)-MS via the reproducible separation of the standard basic proteins (%RSD values (n = 5) < 1% for analysis time reproducibility and < 5% for peak heights, measured from the total ion electropherograms (TIEs) within the same day). The LODs determined using cytochrome c with total ion current and extracted ion current defection were 24.5 and 2.9 fmol, respectively. Using this new coating lysozymes from chicken and turkey egg white could be easily distinguished by CE-MS, demonstrating the usefulness of this method to differentiate animal species. Even after sterilization at 120 degrees C for 30 min, lysozyme could be detected, as well as in wines at concentrations much lower than the limit marked by the EC Commission Regulation. Adulteration of minced meat with 5% of egg-white could also be analysed by our CE-MS protocol.  相似文献   

17.
Injector-internal thermal desorption is a promising technique for the analysis of a wide range of food components (e.g., flavors) or food contaminants (e.g., solvent residues, pesticides, or migrants from packaging materials) in edible oils and fats or fatty food extracts. Separation from the fatty matrix occurs during injection. Using programmed temperature vaporizing (PTV) injection, the oily sample or sample extract was deposited on a small pack of glass wool from which the components of interest were evaporated and transferred into the column in splitless mode, leaving behind the bulk of the matrix. Towards the end of the analysis, the oil was removed by heating out the injector and backflushing the precolumn. The optimization dealt with the gas supply configuration enabling backflush, the injector temperature program (sample deposition, desorption, and heating out), separation of the sample liquid from the syringe needle and positioning it on a support, deactivation of the support surface, holding the plug of fused silica wool by a steel wire, and the analytical sequence maintaining adsorptivity at the desorption site low. It was performed for a mixture of poly(vinyl chloride) (PVC) plasticizers in oil or fatty food. Using MS in SIM, the detection limit was below 0.1 mg/kg for plasticizers forming single peaks and 1 mg/kg for mixtures like diisodecyl phthalate. For plasticizers, RSDs of the concentrations were below 10%; for the slip agents, oleamide and erucamide, it was 12%. The method of incorporating PTV injection was used for about one year for determining the migration from the gaskets of lids for glass jars into oily foods.  相似文献   

18.
毛细管电泳-质谱联用技术的新进展   总被引:1,自引:0,他引:1  
周志贵  李珉  白玉  刘虎威 《色谱》2009,27(5):598-608
毛细管电泳-质谱(CE-MS)联用技术综合了CE的高效分离能力、广泛的样品适应性和MS的高灵敏度、可提供结构信息等优势,已发展成为一种重要的分离分析手段。本文对近几年来CE-MS联用接口技术的发展作一简单介绍,并对CE-MS在生命分析、食品药品分析等领域的一些应用进展予以综述。  相似文献   

19.
Mass spectrometry (MS) has become a key tool for the characterization of biologically relevant molecules in the last decade. Due to the complexity of most biological samples an upstream separation is essential. Capillary electrophoresis (CE) has gained much interest due to its high separation efficiency, speed, and often complementary selectivity to liquid chromatography. We describe the state-of-the-art of on-line CE-MS for the analysis of molecules of biological origin. The characterization of peptides, including the study of post-translational modifications, intact proteins, oligonucleotides, and related interaction studies are reviewed. Relevant publications are summarized in tables, including some important method parameters. Key applications are discussed with respect to the advantages and limitations of CE-MS. Coupling interfaces, preconcentration techniques, capillary coatings, and the different CE techniques, e.g., capillary zone electrophoresis, capillary isoelectric focusing, capillary gel electrophoresis, etc. are briefly discussed against the background of their bioanalytical applications.  相似文献   

20.
CE-MS has evolved into a strong alternative to LC-MS. Most of CE-MS applications deal with characterization and identification. However, quantitative aspects have gained importance in, e.g., pharmaceutical and biotechnological applications. Here we summarize and evaluate various methodological aspects in order to achieve sensitive and reproducible results. Similar to LC-MS, aspects of matrix influence on the electrospray process need to be carefully addressed when quantitative results are intended by CE-MS. Due to a more complicated coupling special emphasis needs to be put on the CE-MS interface. Generally linearity over more than three orders of magnitude can be achieved by CE-ESI-MS. Furthermore, a literature survey has been performed in order to give an overview over quantitative measurements performed by CE-MS. The precision can be doubled when changing from a structural related to an isotopically labeled internal standard. Thus a level of precision better than 5% RSD can be achieved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号