首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Despite the rapid development of nanomaterials and nanotechnology, it is still desirable to develop novel nanoparticle-based techniques which are cost-effective, timesaving, and environment-friendly, and with ease of operation and procedural simplicity, for assay of target analytes. In the work discussed in this paper, the dye fluorescein isothiocyanate (FITC) was conjugated to 1,6-hexanediamine (HDA)-capped iron oxide magnetic nanoparticles (FITC–HDA Fe3O4 MNPs), and the product was characterized. HDA ligands on the surface of Fe3O4 MNPs can bind 2,4,6-trinitrotoluene (TNT) to form TNT anions by acid–base pairing interaction. Formation of TNT anions, and captured TNT substantially affect the emission of FITC on the surface of the Fe3O4 MNPs, resulting in quenching of the fluorescence at 519 nm. A novel FITC–HDA Fe3O4 MNPs-based probe featuring chemosensing and magnetic separation has therefore been constructed. i.e. FITC–HDA Fe3O4 MNPs had a highly selective fluorescence response and enabled magnetic separation of TNT from other nitroaromatic compounds by quenching of the emission of FITC and capture of TNT in aqueous solution. Very good linearity was observed for TNT concentrations in the range 0.05–1.5 μmol?L?1, with a detection limit of 37.2 nmol?L?1 and RSD of 4.7 % (n?=?7). Approximately 12 % of the total amount of TNT was captured. The proposed methods are well-suited to trace detection and capture of TNT in aqueous solution.
Figure
Iron oxide magnetic nanoparticles-based selective fluorescent response and magnetic separation probe for 2,4,6-trinitrotoluene  相似文献   

2.
A new amperometric immunosensor for 2,4,6-trinitrotoluene based on the working principle of competitive enzyme-linked immunosorbent assay was developed and characterised. An electrodeposited nanogold substrate was functionalised by deposition of self-assembled monolayers of 2-aminoethanethiol as linkers for the subsequent immobilisation of polyamidoaminic dendrimers. Our approach makes use of those dendrimers to anchor a trinitrobenzene-ovalbumin conjugate on the electrode surface. The immunosensor was tested and validated for the determination of 2,4,6-trinitrotoluene showing high selectivity with respect to other nitroaromatic compounds, a limit of detection of 4.8 ng/mL and a limit of quantitation of 6 ng/mL. The immunosensor was tested for the quantification of the analyte in spiked soils and in a real sample of post-blast soil, evidencing a good recovery rate (113 %).
Figure
Setup of sensor and immunoassay for TNT  相似文献   

3.
We have prepared a kind of molecularly imprinted nano-porous sensing film for the adsorption of melamine. It consists of a graphite electrode impregnated with paraffin and modified with melamine, chitosan, silver nanoparticles and polyquercetin by employing an electrochemical method. The film displays excellent and highly selective sorption of melamine in the 3-dimensional porous nanomaterial, and this was applied to the determination of melamine in dairy products. The electrode responds linearly to melamine in the concentration range of 1?×?10?8 to 9?×?10?7?M, with a detection limit of 1.3?×?10?9?M (at 3??) in real samples, and with recoveries in the range of 99 to 102%. The surface structure and composition of the sensor was characterized by scanning electron microscopy, X-ray photoelectron spectroscopy, infrared spectroscopy, and electrochemical techniques. The interaction between the porous film and melamine was also studied by using hexacyanoferrate (III) as an electrochemical indicator.
Figure
Extremely sensitive sensor for melamine used a kind of molecularly mprinted nano-porous film, which displays an excellent and highly selective sorption to melamine in the 3-dimensional porous nanomaterial. The interaction between the porous film and melamine also was studied by using hexacyanoferrate (III) as an electrochemical indicator.  相似文献   

4.
A sensitive amperometric sensor for norfloxacin (NF) was introduced. The receptor layer was prepared by molecularly imprinted photopolymerization of acrylamide and trimethylolpropane trimethacrylate on the surface of a gold electrode. The binding mechanism of the molecularly imprinted polymer was explored by ultraviolet (UV) and infrared (IR) spectroscopy. The chemosensor was characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance (EI), and scanning electron microscopy (SEM). The electrode prepared by photopolymerization has a better recognition ability to template molecules than that of electropolymerization and NIP. Some parameters affecting sensor response were optimized. Norfloxacin was detected by measurements of an amperometric it curve. The linear relationships between current and logarithmic concentration are obtained from 1.0?×?10?9 to 1.0?×?10?3?mol?L?1. The detection limit of the sensor was 1.0?×?10?10?mol?L?1. The proposed method is sensitive, simple, and cheap, and is applied to detect NF in human urine successfully.
Figure
Amperometric i-t curves of MIPs electrode  相似文献   

5.
A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L?1 and 9 μg L?1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L?1), and coefficients of variation of 7 % and 5 % (n?=?5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.
Figure
?  相似文献   

6.
Xiaoyu Cao 《Mikrochimica acta》2014,181(9-10):1133-1141
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe ssDNA on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. A thiol-tagged DNA strand coupled to horseradish peroxidase conjugated to AuNP served as a tracer. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. Hybridization with the target DNA was studied by measuring the electrochemical signal response of horseradish peroxidase using differential pulse voltammetry. The calibration plot is linear in the 5.0?×?10?14 and 5.0?×?10?9 M concentration range, and the limit of detection is 2.2?×?10?15 M. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA. The approach is deemed to provide a sensitive and reliable tool for highly specific detection of DNA.
Figure
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe (ssDNA) on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA  相似文献   

7.
We report on a graphite electrode onto which polypyrrole was electrodeposited and then doped with chromate ion. This electrode can serve as a Cr(VI)-selective solid-state electrode. Electropolymerization of pyrrole was performed potentiostatically at 0.80?V (vs. SCE) using battery graphite as the working electrode in a solution containing 0.10?M of pyrrole and 20?mM of chromate. A platinum wire was used as an auxiliary electrode. The new electrode displays high selectivity, a very wide dynamic range, a sufficiently fast response time and a good shelf lifetime. It shows a linear Nernstian response over 1.0?×?10?6 to 1.0?×?10?1?M concentration range (with a slope of 26.55?±?0.20?mV per log of concentration). The detection limit is 0.5?μM, and the pH optimum is 7.0.
Figure
A highly selective solid state Cr(VI) ion-selective electrode based on polypyrrole conducting polymer was prepared. The introduced Cr(VI) micro sensor electrode exhibited linear response over a wide working concentration range with a high regression coefficient and a near Nernstian slope. The SEM image of PPy/CrO4 thin film shows unevenly distributed nanoparticles.  相似文献   

8.
We report on a new method for the selective extraction of the antibiotic sulfamethoxazole (SMO) in milk that is making use of a molecularly imprinted polymer (MIP) monolith as the sorbent. The monolith was synthesized in the tip of a micropipette using SMO as the template and a combination of acrylamide and 4-vinylpyridine as the co-functional monomers. The monolith was connected to syringes in different sizes and used for microextraction without any other treatment and showed high selectivity and enrichment ability for SMO. It was applied to the selective extraction and sensitive determination of SMO in milk. The linear range is from 5–600?μg?L?1, the correlation coefficient (r2) is 0.9984, and the detection limit (at S/N?=?3) is 1?μg?L?1. Recoveries range from 93.6 to 101.7?%, with relative standard deviations of <6.1?%.
Figure
A method for the selective extraction of sulfamethoxazole (SMO) in milk based on molecularly imprinted polymer (MIP) monolith as the sorbent was developed. The linear ranges were 5–600?μg/L for SMO in milk. High recoveries of 93.6?~?101.7?% from milk were obtained with relative standard deviations less than 6.1?%.  相似文献   

9.
A biomimetic sensor for norfloxacin is presented that is based on host-guest interactions and potentiometric transduction. The artificial host was imprinted into polymers made from methacrylic acid and/or 2-vinyl pyridine. The resulting particles were entrapped in a plasticized poly(vinyl chloride) (PVC) matrix. The sensors exhibit near-Nernstian response in steady state evaluations, and detection limits range from 0.40 to 1.0???g?mL?1, respectively, and are independent of pH values at between 2 and 6, and 8 and 11, respectively. Good selectivity was observed over several potential interferents. In flowing media, the sensors exhibit fast response, a sensitivity of 68.2?mV per decade, a linear range from 79???M to 2.5?mM, a detection limit of 20???g?mL?1, and a stable baseline. The sensors were successfully applied to field monitoring of norfloxacin in fish samples, biological samples, and pharmaceutical products.
Figure
?  相似文献   

10.
We describe a molecularly imprinted electrochemical sensor for selective and sensitive determination of β2-agonists. It is making use of a combination of single-wall carbon nanotubes (SWNTs) with a molecularly imprinted sol–gel. The SWNTs were introduced in order to enhance electron transport and sensitivity. The imprinted sol–gel film with its specific binding sites acts as a selective recognition element and as a preconcentrator for β2-agonists. The morphology of the imprinted film was characterized by scanning electron microscopy. The optimized sensor displays high sensitivity and excellent selectivity for the β2-agonists as shown for their determination in human serum samples.
Figure
A molecularly imprinted electrochemical sensor was constructed for selective and sensitive determination of β2-agonists. The optimized sensor displays high sensitivity and excellent selectivity for the β2-agonists as shown for their determination in human serum samples.  相似文献   

11.
We have examined the specificity of electrosynthesized poly-o-phenylenediamine as a kind of material molecularly imprinted with metal chelates. Molecularly imprinted polymers (MIPs) were prepared in situ by an electrochemical method. The EDTA chelate complexes of Cu(II), Zn(II), Fe(III) and Cd(II) ions were used as templates of the MIPs deposited on a gold electrode of a quartz crystal microbalance (QCM). The binding ability and specificity of the MIPs were investigated via the frequency response of the QCM to the adsorption of the template chelates and their analogs. Linear relationships are observed between the frequency shift and the concentration of the template chelates over a typical range of ~10?6 to ~10?4?mol·L?1. The results reveal good binding specificity of such MIPs for their templates over structurally related analogs, but the selectivity coefficients are less significant than that for enantiomers. The results also suggest no significant correlation between binding specificity and the ionic (or atomic) radius of the investigated metal ions. The observed specificity is qualitatively attributed to the overall conformational difference of the metal-EDTA complexes resulting from their difference in both ionic radius and electronic structures.
Figure
Schematic Representation of the Molecular Imprinting Procedures. The metal ions chelate with EDTA to form metal-EDTA chelates as the template, then polymerization is initiated by an electrochemical method. After the polymerization, the templates are removed to create cavities in the polymer film which have binding ability and specificity to the templates.  相似文献   

12.
We present two kinds of electrochemical immunoassays for the tumor necrosis factor α (TNF-α) which is a protein biomarker. The antibody against TNF-α was immobilized on a graphite screen-printed electrode modified with poly-anthranilic acid (ASPE). The first is based on impedimetry (and thus label-free) and the target antigen (TNF-α) is captured by the surface of the modified electrode via an immunoreaction upon which impedance is changed. This sensing platform has a detection limit of 5.0 pg mL?1. In the second approach, the monoclonal antibodies on the modified electrode also bind to the target antigen (TNF-α), but detection is based on a sandwich immunoreaction. This is performed by first adding secondary anti-TNF-α antibodies labeled with horseradish peroxidase, and then detecting the response of the sandwich system by adding hydrogen peroxide and acetaminophen as a probe system for HRP activity. This immunosensor also has a very low detection limit (3.2 pg mL?1). The experimental conditions of both assays were studied and optimized via electrochemical impedance spectroscopy and differential pulse voltammetry. The method was then applied to the determination of TNF-α in serum samples where it displayed high sensitivity, selectivity and reproducibility.
Figure
A novel electrochemical immunosensor capable of sensitive and selective detection of tumor necrosis factor α is developed. It is based on the poly-anthranilic acid modified graphite screen-printed electrodes. Validation was made by analyzing human serum.  相似文献   

13.
We report on a highly sensitive glucose biosensor that was fabricated from a composite made from mesoporous hydroxyapatite and mesoporous titanium dioxide which then were ultrasonically mixed with multi-walled carbon nanotubes to form a rough nanocomposite film. This film served as a platform to immobilize glucose oxidase onto a glassy carbon electrode. The morphological and electrochemical properties of the film were examined by scanning electron microscopy and electrochemical impedance spectroscopy. Cyclic voltammetry and chronoamperometry were used to characterize the electrochemical performances of the biosensor which exhibited excellent electrocatalytic activity to the oxidation of glucose. At an operating potential of 0.3?V and pH 6.8, the sensor displays a sensitivity of 57.0?μA?mM?1?cm?2, a response time of <5?s, a linear dynamic range from 0.01 to 15.2?mM, a correlation coefficient of 0.9985, and a detection limit of 2?μM at an SNR of 3. No interferences are found for uric acid, ascorbic acid, dopamine and most carbohydrates. The sensor is stable and was successfully applied to the determination of glucose in real samples.
Figure
Mesoporous hydroxyapatite, titanium dioxide and multi-walled carbon nanotubes were ultrasonically mixed to form a rough nanofilm, and a new glucose biosensor was fabricated based on this nanofilm. The biosensor had great bioelectrocatalytic activity to glucose oxidation, and it exhibited a high sensitivity, wide linear dynamic range and high selectivity for glucose determination.  相似文献   

14.
We have developed a rapid, selective and efficient method for dispersive solid-phase microextraction (DSPME) using microbeads of a molecularly imprinted polymer (MIP). It enables the pre-concentration of sulfamethazine and sample clean-up prior to capillary electrophoresis with UV detection. The microbeads were synthesized via precipitation polymerization using sulfamethazine, methacrylic acid and ethylene glycol dimethacrylate (EGDMA) as the template molecule, the functional monomer and the cross-linking monomer, respectively. Characterization by SEM displayed the high uniformity and dispersibility of the MIP microbeads. The adsorption and desorption of sulfamethazine and the parameters for CE were optimized to result in a limit of detection of 1.1?μg?L?1, which is 373-fold lower than that of direct CE detection. The equilibration time of extraction was reduced to 5?min, and the selectivity of the microbeads was significantly improved compared to the non-imprinted polymer. The method was successfully applied to the determination of trace sulfamethazine in several milk samples, with recoveries in the range of 89?% to 110?%.
Figure
A novel, rapid, selective and efficient dispersive solid-phase microextraction approach using molecularly imprinted polymer microbeads was developed for pre-concentration of sulfamethazine and sample clean-up prior to capillary electrophoresis detection.  相似文献   

15.
Deoxyribonucleic acid (DNA) was electrochemically deposited on a carbon ionic liquid electrode to give a biosensor with excellent redox activity towards paraquat as shown by cyclic voltammetry and differential pulse voltammetry. Experimental conditions were optimized with respect to sensing paraquat by varying the electrochemical parameters, solution pH, and accumulation time of DNA. Under the optimized conditions, a linear relation exists between the reduction peak current and the concentration of paraquat in the range from 5?×?10?8 mol L?1 to 7?×?10?5 mol L?1, with a detection limit of 3.6?×?10?9 mol L?1. The utility of the method is illustrated by successful analysis of paraquat in spiked real water samples.
Figure
The DNA was electrodeposited onto the CILE under +1.5?V for 1200?s. The electrochemical behaviors of paraquat on the modified electrode had been studied by cyclic voltammetry and differential pulse voltammetry. Five ml phosphate buffer (pH 7.0) solution was added into an electrochemical cell (10?ml) and then paraquat was successfully added into the cell. The differential pulse voltammograms were recorded when swept from ?0.8?V to ?0.3?V. The peak currents at about ?0.63?V for paraquat were measured.  相似文献   

16.
We report on a simple and reliable method for the determination of trace cadmium ion using a glassy carbon electrode (GCE) modified with cupferron, ß-naphthol and MWCNTs. The operational mechanism consists of several steps: first, the ligand cupferron on the modified electrode reacts with Cd2+ ion to form a chelate compound. Next, this chelate is adsorbed by the carrier ß-naphthol following the principle of organic co-precipitation. Finally, the coprecipitated complex is detected by the GCE. This scheme is interesting because it combines preconcentration and electrochemical detection. Two linear responses are obtained, one in the concentration range of 5.0?×?10?11 to 1.6?×?10?8 M, the other in the range of 1.6?×?10?8 to 1.42?×?10?6 M, with a lower detection limit of 1.6?×?10?11 M. This modified GCE does not suffer from significant interferences by Cu(II), Hg(II), Ag(I), Fe(III), Pb(II), Cr(III), Zn(II), NO3?, Cl?, SO 4 2? ions and EDTA. The response of the electrode remained constant for at least 3 weeks of successive operation. The method presented here provides a new way for the simultaneous separation, enrichment, and electrochemical detection of trace cadmium ion.
Figure
Separation, enrichment and electrochemical detection of trace cadmium ion were simultaneously and synchronously carried through on the electrode modified with cupferron, ß-naphthol, and multiwalled carbon nanotubes. It shows higher selectivity, excellent sensitivity and good stability.  相似文献   

17.
Human mammaglobin (MG) has been found to be the most specific molecular marker for the hematogenous spread of breast cancer cells. In our study, an electrochemical impedance spectroscopic DNA biosensor was established for the detection of MG in breast cancer patients. The working conditions for the biosensor, such as immobilization time, rinse process, and hybridization process, were optimized. Under the optimal conditions, the charge transfer resistance of the proposed DNA biosensor shows excellent correlation with the amount of the complementary oligonucleotides in the range from 1.0?×?10?9 to 2.0?×?10?8?M. The detection limit is 5.0?×?10?10?M. The proposed biosensor was used to detect the polymerase chain reaction amplification products of actual clinical breast cancer samples. The results were compared with that obtained by conventional gel electrophoresis. The results indicate that the electrochemical impedance spectroscopic assay is significantly sensitive and time-saving. The simple strategy described here is expected to be used in clinical application for early diagnosis of breast cancer.
Figure
The specificity of the electrochemical biosensor for the PCR products investigated by comparing the detection results of positive sample and negative control.  相似文献   

18.
We describe a molecularly imprinted polymer (MIP) for the solid-phase extraction of the skin protectant allantoin. The MIP was deposited on the surface of monodisperse silica microspheres possessing acroyl groups on the surface (MH-SiO2). The resulting MIP microspheres (MH-SiO2@MIP) showed a 3.4-fold higher adsorption capacity and a 1.9-fold better selectivity for allantoin than the respective non-imprinted polymer (MH-SiO2@NIP). The monolayer adsorption capacities of the MH-SiO2@MIP and the MH-SiO2@NIP were calculated with the help of the Langmuir model and found to be 6.8 and 1.9 mg?g?1, respectively. Adsorption kinetics fit a pseudo-second order rate mechanism, with an initial adsorption rate of 1.44 for the MH-SiO2@MIP, and of 0.07 mg?g?1?min?1 for the MH-SiO2@NIP. The material can be regenerated, and its adsorption capacity for allantoin remains stable for at least five regeneration cycles. It was successfully used as a sorbent for the selective solid-phase extraction of allantoin from Rhizoma dioscoreae.
Figure
A molecularly imprinted polymer for the selective separation of allantoin was developed. It was successfully used as a sorbent for the selective solid-phase extraction of allantoin from Rhizoma dioscoreae.  相似文献   

19.
We describe a silver(I)-selective carbon paste electrode modified with multi-walled carbon nanotubes and a silver-chelating Schiff base, and its electrochemical response to Ag(I). Effects of reduction potential and time, accumulation time, pH of the solution and the stripping medium were studied by differential pulse anodic stripping voltammetry and optimized. The findings resulted in a method for the determination of silver over a linear response range (from 0.5 to 235 ng?mL?1) and with a detection limit as low as 0.08 ng?mL?1. The sensor displays good repeatability (with the RSD of ±?2.75 % for 7 replicates) and was applied to the determination of Ag(I) in water samples and X-ray photographic films.
Figure
Open circuit accumulation of Ag(I) onto a surface of EHPO-MCPE and determination by Differential pulse anodic stripping voltammetry  相似文献   

20.
We report on the synthesis of cesium ion-imprinted polymer nanoparticles that were prepared by a precipitation polymerization strategy using dibenzo-24-crown-8 ether as a selective crown ether, methacrylic acid as the functional monomer, ethyleneglycol dimethacrylate as the crosslinker, and AIBN as the radical initiator. The prepared sorbents have a diameter of 50–90 nm and display highly selective binding capability for Cs(I) ion, with rapid adsorption and desorption. The maximum adsorption capacity is 50 mg g?1, and the preconcentration factor is around 100 at pH 9.0. Cesium ion was then determined by flame photometry with a detection limit (3σ) of 0.7 ng mL?1 and with a standard deviation of 0.9 %.
Figure
A novel nano-sized ion imprinted polymer has been prepared for separation and determination of Cs(I) ions in different water samples. The results indicated that the use of imprinted nanoparticles has many advantages, such as selectivity, reusability, application in the complex matrixes and preconcentration of the initial ions in dilute solutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏