共查询到20条相似文献,搜索用时 0 毫秒
1.
A nitrogen-doped graphene/carbon nanotubes (NGR–NCNTs) nanocomposite was employed into the study of the electrochemical sensor via electrodeposition for the first time. The morphology and structure of NGR–NCNTs nanocomposite were investigated by scanning electron microscopy (SEM) and transmission electron microscopy (TEM), respectively. Meanwhile, the electrochemical performance of the glassy carbon electrode (GCE) modified with electrodeposited NGR–NCNTs (ENGR–NCNTs/GCE) towards caffeine (CAF) and vanillin (VAN) determination was demonstrated by cyclic voltammetry (CV) and square wave voltammetry (SWV). Under optimal condition, ENGR–NCNTs/GCE exhibited a wide linearity of 0.06–50 μM for CAF and 0.01–10 μM for VAN with detection limits of 0.02 μM and 3.3 × 10−3 μM, respectively. Furthermore, the application of the proposed sensor in food products was proven to be practical and reliable. The desirable results show that the ENGR–NCNTs nanocomposite has promising potential in electrocatalytic biosensor application. 相似文献
2.
Single-wall carbon nanotubes (SWNT) were dispersed into water in the presence of dicetyl phosphate (DCP), and then a SWNT-DCP
film-coated glassy carbon electrode (GCE) was constructed. The electrochemical behavior of acetaminophen at bare GCE and SWNT-DCP
modified GCE were compared, suggesting that the SWNT-DCP-modified GCE significantly enhances the oxidation peak current of
acetaminophen. A sensitive and simple electrochemical method with a good linear relationship in the range of 1.0 × 10−7–2.0 × 10−5 mol L−1, was developed for the determination of acetaminophen. The detection limit is 4.0 × 10−8 mol L−1 for 3-min accumulation. This method was successfully demonstrated with tablets. 相似文献
3.
Ali A. Ensafi Hassan Karimi-Maleh M. Keyvanfard 《International journal of environmental analytical chemistry》2013,93(6):650-660
The electrochemical response of a modified-carbon nanotubes paste electrode with p-aminophenol was investigated as an electrochemical sensor for sulfite determination. The electrochemical behaviour of sulfite was studied at the surface of the modified electrode in aqueous media using cyclic voltammetry and square wave voltammetry. It has been found that under the optimum condition (pH 7.0) in cyclic voltammetry, the oxidation of sulfite occurs at a potential about 680?mV less positive than that of an unmodified-carbon nanotubes paste electrode. Under the optimized conditions, the electrocatalytic peak current showed linear relationship with sulfite concentration in the range of 2.0?×?10?7–2.8?×?10?4?mol?L?1 with a detection limit of 9.0?×?10?8?mol?L?1 sulfite. The relative standard deviations for ten successive assays of 1.0 and 50.0?µmol?L?1 sulfite were 2.5% and 2.1%, respectively. Finally, the modified electrode was examined as a selective, simple and precise new electrochemical sensor for the determination of sulfite in water and wastewater samples. 相似文献
4.
5.
Electrochemical determination of malachite green using a multi-wall carbon nanotube modified glassy carbon electrode 总被引:1,自引:0,他引:1
A multi-wall carbon nanotube (MWNT) film-modified electrode is described for the determination of malachite green (MG). The
electrochemical profile of MG was examined using cyclic voltammetry (CV) and differential pulse voltammetry (DPV), suggesting
that the MWNT film facilitates the electron transfer of MG in terms of a potential shift and then significantly enhances the
oxidation peak current of MG. The experimental parameters, such as supporting electrolyte, thickness of MWNT film, scan rate
and accumulation time, were optimized. Consequently, a sensitive and convenient electrochemical method is proposed for the
determination of MG. The oxidation peak current is proportional to the concentration of MG over the range from 5.0 × 10−8 to 8.0 × 10−6 mol L−1 obeying the following equation: ip = 0.09 + 1.19 × 107 C (r = 0.995, ip in μA, C in mol L−1). The detection limit is 6.0 × 10−9 mol L−1 (signal to noise = 3) after 5 min of accumulation. Moreover, this method possesses good reproducibility (RSD is 5.6%, n =
8) as well as long-term stability. Finally, the new method was employed to determine MG in fish samples.
Correspondence: W. Huang, Department of Chemistry, Hubei Institute for Nationalities, Enshi 445000, P.R. China 相似文献
6.
Cansu Bayraktar Bahire Filiz Senkal 《International journal of environmental analytical chemistry》2018,98(10):889-906
In this study, a carbon paste electrode modified with a novel 1-(3-aminopropyl) imidazole functionalised crosslinked chlorosulfonated poly(styrene)-divinyl benzene polymer was used for selective and sensitive determination of the trace amounts of Pb2+, Cu2+ and Hg2+ ions by square wave anodic stripping voltammetry. The effect of some parameters such as paste composition, pH, preconcentration time, reduction potential and time, type of supporting electrolyte and potential scan rate on the determination of metal ions were investigated to find the optimal conditions. The effective open-circuit accumulation of the studied metal ions was succeeded only by the modification of the carbon paste electrode with functional polymer. For 6 min open-circuit preconcentration, the detection limit of Pb2+, Cu2+ and Hg2+ was found to be 5, 9 and 14 µgL?1, respectively at 100 mVs?1. The results confirmed that the lower concentration levels of these trace metal ions can be determined with the increase of preconcentration time and/or potential scan rate. Good detection limits and large dynamic concentration ranges were also obtained for their binary and ternary mixtures. The optimised method was successively applied to determine the concentration of Pb2+, Cu2+ ions in the tap water sample and Cu2+ ion in the waste water sample in the presence of possible interfering species (RSD<1%, recoveries 96–110% for 4 min preconcentration). 相似文献
7.
A catalytic adsorptive stripping voltammetric method for the determination of copper(II) on a carbon paste electrode (PCE)
in an alizarin red S (ARS)-K2S2O8 system is proposed. In this method, copper(II) is effectively enriched by both the formation and adsorption of a copper(II)-ARS
complex on the PCE, and is determined by catalytic stripping voltammetry. The catalytic enhancement of the cathodic stripping
current of the Cu(II) in the complex results from a redox cycle consisting of electrochemical reduction of Cu(II) ion in the
complex and subsequent chemical oxidation of the Cu(II) reduction product by persulfate, which reduces the contamination of
the working electrode from Cu deposition and also improves analytical sensitivity. In Britton-Robinson buffer (pH 4.56±0.1)
containing 3.6×10−5 mol L−1 ARS and 1.6×10−3 mol L−1 K2S2O8, with 180 s of accumulation at −0.2 V, the second-order derivative peak current of the catalytic stripping wave was proportional
to the copper(II) concentration in the range of 8.0×10−10 to ∼3.0×10−8 mol L−1. The detection limit was 1.6×10−10 mol L−1. The proposed method was evaluated by analyzing copper in water and soil. 相似文献
8.
A sensitive and stable electrochemical sensor was developed by modification of carbon paste electrode with ZrO2/graphene/chitosan nanocomposite. The modified sensor served as a potential electrocatalytic platform for dopamine. Electrochemical impedance spectroscopy studies indicated reduction of charge transfer resistance at the modified electrode surface thereby facilitating the electron transfer process which resulted in higher current response to dopamine. The electrochemical behavior of dopamine at the modified electrode was studied using cyclic and square wave voltammetry. The maximum current response for the electro-oxidation of dopamine was observed at pH 7.4 and the process was realized to be diffusion controlled. The modified sensor demonstrated linearity in the range 1000–5000 nM, with high sensitivity (22 nA/nM), detection limit of 11.3 nM and selectivity for dopamine in the presence of ascorbic and uric acid which are found to co-exist with dopamine in physiological media. The method was employed for quantification of dopamine in a pharmaceutical formulation. 相似文献
9.
A carbon nanotube paste (CNTP) electrode and a carbon nanotube paste/glucose oxidase (CNTP/GOx) electrode were prepared, and the electrochemiluminescent (ECL) behavior of luminol in the presence of glucose was investigated in detail at each of these electrodes. Compared to the classical carbon paste (CP) electrode, the CNTP electrode incorporating glucose oxidase greatly enhanced the response of the ECL sensor to glucose due to the electrocatalytic activity of the carbon nanotubes, the specificity of the enzymatic reaction, and the sensitivity of the luminol ECL reaction. Under optimal conditions, the electrode was found to respond linearly to glucose in the concentration range 1.0x10(-6) approximately 2.0x10(-3) mol/L, and the detection limit (defined as the concentration that can be detected at a signal-to-noise ratio of 3) was found to be a glucose concentration of 5.0x10(-7) mol/L. The method used to prepare the CNTP/GOx electrode was very convenient, and the electrode surface could be renewed in the case of fouling by simply polishing or cutting it to expose a new and fully active surface. The relative standard deviations (RSD) were found to be 6.8% and 8.9% for the CNTP electrode and the CNTP/GOx electrode (n=6). The electrode retained 95% of its initial response after two weeks. 相似文献
10.
Abbas Afkhami Hasan Bagheri Hosein Khoshsafar Mohammad Saber-Tehrani Masoumeh Tabatabaee Ali Shirzadmehr 《Analytica chimica acta》2012
A modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and 3-(4-methoxybenzylideneamino)-2-thioxothiazolodin-4-one as a new synthesized Schiff base was constructed for the simultaneous determination of trace amounts of Hg(II) and Pb(II) by square wave anodic stripping voltammetry. The modified electrode showed an excellent selectivity and stability for Hg(II) and Pb(II) determinations and for accelerated electron transfer between the electrode and the analytes. The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as pH, deposition potential and deposition time were optimized for the purpose of determination of traces of metal ions at pH 3.0. Under optimal conditions the limits of detection, based on three times the background noise, were 9.0 × 10−4 and 6.0 × 10−4 μmol L−1 for Hg(II) and Pb(II) with a 90 s preconcentration, respectively. In addition, the modified electrode displayed a good reproducibility and selectivity, making it suitable for the simultaneous determination of Hg(II) and Pb(II) in real samples such as sea water, waste water, tobacco, marine and human teeth samples. 相似文献
11.
This work offers construction and comparative evaluation the performance characteristics of conventional polymer (I), carbon paste (II) and carbon nanotubes chemically modified carbon paste ion selective electrodes (III) for meclofenoxate hydrochloride are described. These electrodes depend mainly on the incorporation of the ion pair of meclofenoxate hydrochloride with phosphomolybdic acid (PMA) or phosphotungestic acid (PTA). They showed near Nernestian responses over usable concentration range 1.0 × 10−5 to 1.0 × 10−2 M with slopes in the range 55.15–59.74 mV (concentration decade)−1. These developed electrodes were fully characterized in terms of their composition, response time, working concentration range, life span, usable pH and temperature range. The electrodes showed a very good selectivity for Meclo with respect to a large number of inorganic cations, sugars and in the presence of the degradation product of the drug (p-chloro phenoxy acetic acid). The standard additions method was applied to the determination of MecloCl in pure solution, pharmaceutical preparations and biological samples. Dissolution testing was also applied using the proposed sensors. 相似文献
12.
Xiuhui He Li Chen Xuan Xie Zhaohong Su Cong Qin Ying Liu Ming Ma Shouzhuo Yao Le Deng Qingji Xie Yun Tian Dilan Qin Yueping Luo 《Mikrochimica acta》2012,176(1-2):81-89
We report on a glassy carbon electrode (GCE) modified with a lead ionophore and multiwalled carbon nanotubes. It can be applied to square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) for 300?s in pH?4.5 acetate buffer containing 400?μg?L?1 of Bi(III). The ionophore-MWCNTs film on the GCE possesses strong and highly selective affinity for Pb(II) as confirmed by quartz crystal microbalance experiments. Under the optimum conditions, a linear response was observed for Pb(II) ion in the range from 0.3 to 50?μg?L?1. The limit of detection (at S/N?=?3) is 0.1?μg?L?1. The method was applied to the determination of Pb(II) in water samples with acceptable recovery. Figure
A glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes is successfully applied to sensitive and selective square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) in pH?4.5 solutions containing 400?μg?L?1 of Bi(III). 相似文献
13.
A chemically modified electrode is constructed based on the multi-walled carbon nanotubes (MWNTs)/4-aminobenzeresulfonic acid (4-ABSA) film-coated glassy carbon electrode. The electrocatalytic oxidation of tyrosine (Tyr) is investigated on the surface of the MWNTs/4-ABSA-modified electrode using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The prepared modified electrode shows voltammetric responses with high sensitivity and selectivity for Tyr in optimal conditions, which makes it very suitable for sub-micromolar detection of Tyr. A sensitive oxidation peak at +0.64 V is employed to determine Tyr. Good linear relationship between the oxidation peak current and the Tyr concentration in the range of 1 × 10−7 to 5 × 10−5 mol/L is obtained in phosphate buffer solution with pH 7.0. By use of modified electrode, the voltammetric detection limit for Tyr in DPV measurements is 8 × 10−8 mol/L (S/N = 3). Good sensitivity, selectivity and stability of the low-cost modified electrode make it very suitable for the determination of trace amounts of Tyr in pharmaceutical and clinical preparations. 相似文献
14.
The preparation of Hg(II)-modified multi walled carbon nanotube (MWCNT) by reaction of oxidized MWCNT with aqueous HgCl2 was carried out. The Hg(II)-modified multi walled carbon nanotube (Hg(II)/MWCNT) dispersed in Nafion solution was used to coat the polished graphite electrode surface. The Hg(II)/MWCNT modified graphite electrode was held at a cathodic potential (−1.0 V) to reduce the coordinated Hg(II) to Hg forming nanodroplets of Hg. The modified electrode was characterized by FESEM/EDAX which provided useful insights on the morphology of the electrode. The SEM images showed droplets of Hg in the size of around 260 nm uniformly distributed on the MWCNT. Differential pulse anodic stripping voltammetry (DPASV) and electrochemical impedance spectroscopy were used to study the Hg(II) binding with MWCNT. Differential pulse anodic stripping voltammetry of ppb levels of cadmium and lead using the modified electrode yielded well-defined peaks with low background current under a short deposition time. Detection limit of 0.94 and 1.8 ng L−1 were obtained following a 3 min deposition for Pb(II) and Cd(II), respectively. Various experimental parameters were characterized and optimized. High reproducibility was observed from the RSD values for 20 repetitive measurements of Pb(II) and Cd(II) (1.7 and 1.9%, respectively). The determination of Pb(II) and Cd(II) in tap water and Pb(II) in human hair samples was carried out. The above method of fabrication of Hg(II)/MWCNT modified graphite electrode clearly suggests a safe route for preparing Hg immobilized electrode for stripping analysis. 相似文献
15.
在0.40 mol/L的NaAc-HAc(pH 4.5)缓冲液中,使用JP-303极谱分析仪,依诺沙星在碳糊电极(CPE)上有一灵敏的吸附伏安氧化峰,峰电位为1.17 V(vs.SCE).该氧化峰的二阶导数峰电流与依诺沙星的浓度在4.0×10-9~4.0×10-7 mol/L(富集90 s)范围内呈良好的线性关系,相关系数为0.995,检出限为2.0×10-9 mol/L(S/N=3,富集110 s).探讨了依诺沙星在碳糊电极上的伏安性质和电极反应机理,并且用于诺佳胶囊中依诺沙星的测定. 相似文献
16.
Xiaohua Cai Kurt Kalcher Josef Lintschinger Christian Neuhold 《Mikrochimica acta》1993,112(1-4):135-146
A carbon paste electrode modified with 2-mercapto-4(3H)-quinazolinone was used for the voltammetric determination of mercury(II). Mercury was preconcentrated onto the surface of the modified electrode only by the complexing effect of the modifier without application of potential (i.e. in open-circuit conditions). After exchange of the medium, the accumulated amount of mercury(II) was determined by differential pulse anodic stripping voltammetry. The response depended on the concentration of mercury in the bulk solution, preconcentration time, and other parameters. The detection limit was 0.1 g 1–1 Hg(II) for a preconcentration time of 15 min. Preconcentration for suitable times yielded a linear calibration graph from 0.5 to 6000 g 1–1 Hg(II). For multiple determinations (5 runs), the relative standard deviation was 5% for a concentration of 100 g 1–1 Hg(II). The proposed procedure was used to determine trace mercury in plant and sewage sludge samples with good results.On leave from Hainan University, Hainan Peoples Republic of China 相似文献
17.
This study used square-wave voltammetry and cyclic voltammetry to investigate the electrochemical oxidation of Thioctic Acid (TA) on a Carbon Paste Electrode (CPE) modified with copper-cobalt nanostructures and poly (1,5-Diaminonaphthalene). The voltammetric sensor was sensitive to the oxidation of TA. In addition, we optimized the effects of multiple cycles of deposition of Cu-Co nanostructures, and electro-polymerization of monomer 1,5-DAN, scan rate, and pH. The sensor showed good identification capabilities for TA. The linear responses obtained ranged from 0.6 μM to 150 μM with a detection limit of 0.48 μM for the modified CPE. The adsorption process controlled the oxidation of TA. We used the proposed sensor and method to determine TA in real samples. 相似文献
18.
A simple and rapid electrochemical method is developed for the determination of trace-level norfloxacin, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNTs/Nafion film-coated glassy carbon electrode (GCE) is constructed and the electrochemical behavior of norfloxacin at the electrode is investigated in detail. The results indicate that MWCNTs modified glassy carbon electrode exhibited efficiently electrocatalytic oxidation for norfloxacin (NFX) with relatively high sensitivity, stability and life time. Under conditions of cyclic voltammetry, the current for oxidation of selected analyte is enhanced significantly in comparison to the bare GCE. The electrocatalytic behavior is further exploited as a sensitive detection scheme for the analyte determinations by linear sweep voltammetry (LSV). Under optimized condition in voltammetric method the concentration calibration range and detection limit (S/N=3) are 0.1-100 micromol/L and 5 x 10(-8)mol/L for NFX. The proposed method was successfully applied to NFX determination in tablets. The analytical performance of this sensor has been evaluated for detection of the analyte in urine as a real sample. 相似文献
19.
Electrochemical behavior of metol, which coexists with p-benzeneiol (HQ) at a glassy-carbon electrode modified with multiwall carbon nanotubes (MWNT/GCE), is studied in the thesis.
The results indicate that metol yields a well-defined peak of which two concomitant reductive peaks separate and the potential
separation reaches to 178 mV, and that concomitant HQ has almost no interference with the reduction signal of metol. The values
of the reductive peak current (I
pc) are found to be linearly related to metol concentration over the range of 8.0 × 10−2 −1.0 × 10−5 M, with a detection limit of 5.0 × 10−6 M. Some common matter has no interference with the determination of metol.
Published in Russian in Elektrokhimiya, 2006, Vol. 42, No. 1, pp. 31–35.
The text was submitted by the authors in English. 相似文献
20.
Fariba Tadayon Ali Katebi Abbas Afkhami Yunes Panahi 《International journal of environmental analytical chemistry》2013,93(9):901-915
A new potentiometric sensor for the rapid determination of Hg2+ based on modified carbon paste electrode consisting of room temperature ionic liquid, 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6), multi-walled carbon nanotubes (MWCNTs), alumina nanoparticles and a synthetic macrocyclic diamide ‘7,10,13-triaza-1-thia-4,16-dioxa-6,14-dioxo-2,3;17,18-dinaphtho-cyclooctadecane’ as an efficient ionophore was constructed. Prepared composite is an ideal paste because it has low drift of potential, high selectivity and fast response time (10 s), which leads to a more stable potential signal. The morphology and properties of electrodes surface were characterised by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy. A linear dynamic range of 2.01–2.01 × 107 µg L?1 with detection limit of 1.40 µg L?1 Hg2+ was obtained at pH range of 2.5 to 4.5. The prepared modified electrode shows several advantages such as simple preparation method, high stability of the composite paste, high sensitivity, long-term life time (at least 13 weeks) and remarkable potentiometric reproducibility. The modified electrode was successfully applied for the accurate determination of trace amounts of Hg 2+ in environmental samples. 相似文献