首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
应用高效液相色谱法,建立了硫酸氨基葡萄糖氯化钾胶囊中氨基葡萄糖含量的快速测定方法。采用Hedera NH2色谱柱(250 mm ×4.6 mm,5 μm),流动相为乙腈-磷酸缓冲液( 65∶35),流速为 1.0 mL/min,可变波长紫外检测器,检测波长为195 nm。 结果表明,在上述色谱条件下,氨基葡萄糖浓度在1.6~2.4 g/L范围内线性关系良好,检出限为7.81 mg/L,精密度(RSD,n=6)为0.53%;平均加标回收率为 100%,相对标准偏差为1.1%。该法准确、可靠,无需衍生反应,适用于硫酸氨基葡萄糖氯化钾胶囊中氨基葡萄糖的含量测定。  相似文献   

2.
建立高效液相色谱仪同时测定洗手液中水杨酸和对氯间二甲苯酚含量的方法。采用Shim-pack Scepter C18柱(250 mm×4.6 mm,5 μm),流动相为甲醇–0.1%磷酸水溶液(体积比为70∶30),流量为1.0 mL/min,柱温为室温,检测器为岛津SPD–M20A二极管阵列检测器,检测波长为280 nm。水杨酸和对氯间二甲苯酚与色谱峰面积呈良好的线性关系,线性范围分别为40~400 μg/mL,20~200 μg/mL,相关系数均为r^2=0.999 9。方法的检出限为0.1 μg/mL,水杨酸和对氯间二甲苯酚测定结果的相对标准偏差分别为0.79%,1.39%(n=5),加标回收率为96.9%~99.8%。该方法方法简便、快速、灵敏度高、重现性好,能同时准确检测洗手液中水杨酸和对氯间二甲苯酚的含量。  相似文献   

3.
建立高效液相色谱法测定马来酸麦角新碱注射液中甲硫氨酸含量的方法。采用Venusil HILIC色谱柱(250 mm×4.6 mm, 5μm),以5 mmol/L磷酸氢二钾溶液(用磷酸调节pH值至6.9)-乙腈(体积比为20∶80)为流动相,流量为1.0 mL/min,柱温为30℃,检测波长为215 nm。结果表明,甲硫氨酸质量浓度在20~400μg/mL范围内与色谱峰面积的线性关系良好,相关系数为0.999 9,检出限和定量限分别为0.5、1.6μg/mL,平均加标回收率为99.7%,测定结果的相对标准偏差为0.3%(n=6)。该方法适用于测定马来酸麦角新碱注射液中甲硫氨酸的含量。  相似文献   

4.
邓金  肖正华  张惠静  张梦军  汤建林 《色谱》2007,25(6):942-943
建立了测定人血浆中巴洛沙星含量的固相萃取高效液相色谱紫外检测方法。采用pH 4.5的磷酸盐缓冲液并经Waters Oasis HLB固相萃取小柱对血浆样品进行预处理。以环丙沙星作内标,以十二烷基磺酸钠溶液(取560 mL水加入3.2 g十二烷基磺酸钠)-乙腈(体积比为56∶44,用磷酸调pH至3.0)为流动相,在Diamonsil C18色谱柱(150 mm×4.6 mm,5 μm)上进行分离。方法的线性范围为25~3200 μg/L,线性关系良好(r=0.9996);巴洛沙星的检出限(S/N≥3)为5 μg/L;方法的准确度为100.3%~103.8%;平均提取回收率为57.5%~77.0%,相对标准偏差小于5.1%。方法准确、灵敏,可满足血药浓度监测和药代动力学参数测试的需求。  相似文献   

5.
通过优化色谱条件,建立专属性良好的高效液相色谱测定多种布洛芬药物制剂中布洛芬含量。采用Dikma Silversil C18键合硅胶色谱柱(250 mm×4.6 mm,5μm)为分析柱,柱温为30℃,以乙腈-磷酸溶液(体积比为80∶20)作为流动相,流量为1.0 mL/min,进样体积为10μL,以光电二极管阵列检测器检测,检测波长为263 nm。采用色谱峰面积外标法测定布洛芬缓释胶囊、原料药和颗粒剂中布洛芬的含量。布洛芬质量浓度在0.091 6~1.099mg/mL范围内与色谱峰面积线性关系良好,相关系数为0.999 7,检出限为3.68μg/mL。布洛芬缓释胶囊、原料药和颗粒剂的样品加标平均回收率分别为99.73%~102.00%、99.45%和101.80%,测定结果的相对标准偏差分别为0.27%~1.18%、1.97%和1.99%(n=6)。优化后的高效液相色谱法准确可靠,适用于多种布洛芬药物制剂中布洛芬的含量测定,可以为多种布洛芬药物制剂的质量评价和质量控制提供参考和方法选择依据。  相似文献   

6.
反相高效液相色谱法测定肉松制品中姜黄素的含量   总被引:1,自引:0,他引:1  
建立了肉松制品中姜黄素含量的反相高效液相色谱测定方法。35℃下,以Ultimate XB-C18(4.6mm×150 mm,5μm)为分析柱,乙腈和0.1%磷酸水溶液(pH2.2)作流动相(体积比为50∶50)等度洗脱,流速1.0 mL/min,425 nm波长下检测。结果表明姜黄素在1.69~169μg/mL浓度范围内呈良好的线性关系,线性回归系数r=0.999 9,方法检出限为1.0 mg/kg,实际样品加标回收率范围为86.9%~94.5%,相对标准偏差为4.6%~7.8%(n=6)。该方法准确可靠、重复性好,可用于肉松制品中姜黄素含量测定。  相似文献   

7.
建立人房水中氧氟沙星的高效液相色谱测定法.取房水100 μL,加甲醇去蛋白后,进高效液相色谱分析.色谱条件:色谱柱为Agilent ZORBAX SB-C18(4.6× 150 mm,5μm),柱温25℃,流动相为乙腈-0.4%磷酸(三乙胺调pH 3.5)(13:87),流速1.0 mL/min,检测波长295 nm.氧氟沙星和内标的保留时间分别为7.98和9.55 min,氧氟沙星的线性范围为0.1~2.5μg/mL,回归方程为Y=2.47X+0.08,r=0.9996.低中高三个质控样品的日内精密度(RSD)分别为1.89%,1.71%,1.48%,日间精密度(RSD)分别为3.74%,2.40%,1.75%,方法回收率分别为99.43%,101.4%,101.4%,最低检测浓度为0.01μg/mL.本法操作简单,方法准确,可用于房水中氧氟沙星的含量测定.  相似文献   

8.
建立高效液相色谱法测定化妆品原料中N-乙酰神经氨酸含量的方法。以体积分数为50%的乙酸溶液为水解溶剂,样品于80℃水浴中加热30 min,以CAPCELL PAK SCX柱(250 mm×4.6 mm,5μm)为分析柱,流动相为乙腈-0.1%磷酸水溶液(体积比为80∶20),等度洗脱,流量为1.0 mL/min,柱温为35℃,采用高效液相色谱二极管阵列检测器测定,以色谱峰面积外标法定量。检测波长为205 nm,进样体积为10μL。N-乙酰神经氨酸的色谱峰面积与质量浓度在10.0~500.0μg/ml范围内线性关系良好,相关系数为0.999 9,方法检出限为0.12μg/mL,定量限为0.4μg/mL。样品加标平均回收率为97.7%~98.9%,测定结果的相对标准偏差为0.37%~1.36%(n=6)。该方法样品处理简便、高效,适用于化妆品原料中N-乙酰神经氨酸的含量测定。  相似文献   

9.
反相高效液相色谱法同时测定柿叶中齐墩果酸和熊果酸   总被引:1,自引:0,他引:1  
建立反相高效液相色谱法同时测定柿(Diospyros koki Linn.f.)叶中齐墩果酸和熊果酸的含量.采用Kromasil C18色谱柱(4.6 mm×250 mm,5 μm);流动相:V(甲醇):V(0.2%磷酸水溶液)=87:13;流速:0.8 mL/min;检测波长:210nm;柱温:30℃.齐墩果酸进样量在0.0848~1.696 μg范围内线性关系良好,r=0.9996,平均加样回收率为101.3%;熊果酸进样量在0.1408~2.816 μg范围内线性关系良好,r=0.9995,平均加样回收率为99.0%.3批样品测定结果表明,本法可作为柿叶中齐墩果酸和熊果酸含量测定的方法.  相似文献   

10.
目的 为了研究不同生长期新鲜烟叶中无机阴离子的含量和变换规律,建立了一种固相萃取净化/离子色谱方法测定新鲜烟叶中的7种无机阴离子(F-,Cl-,Br-,NO2-,NO3-,SO42-,PO43-)。方法 样品经0.1 mol/L NaOH水溶液超声提取,萃取液经RP1.0cc固相萃取柱净化后,使用AS11-HC(4 mm×250 mm)色谱柱进行分离,以KOH为流动相,梯度洗脱。 结果 7种无机阴离子在0.10-5.0 μg/mL范围内具有较好的线性(r>0.996),检出限在0.01-0.04 μg/mL之间,定量限在0.04-0.14 μg/mL之间,加标回收率为96.3%~102.1%,相对标准偏差(RSD%)在2.7%~4.8%之间。结论 方法前处理操作简单,7种无机阴离子分离好,检测灵敏准确,可用于不同生长时期新鲜烟叶样品中多种无机阴离子含量的检测分析。  相似文献   

11.
建立测定虫草源饲料添加剂地顶孢霉培养物中腺苷含量的高效液相色谱方法。样品经过研碎、超声处理,离心、过滤后上机测定。腺苷的最佳提取条件:以超纯水为浸提液,用超声波浸提,浸提温度为40℃,浸提时间为55 min。使用Waters Spherisorb ODS2柱(150 mm×3.9 mm,5μm),以甲醇-0.01 mol/L磷酸二氢钾混合液(10∶90)为流动相,流量为1.0 mL/min,进样体积为20μL,检测波长为254 nm。腺苷的质量浓度在0.5~100μg/mL范围内与色谱峰面积成良好的线性关系,相关系数为0.9990。样品测定结果的相对标准偏差为1.65%(n=6),3水平加标的平均回收率为98.19%。该方法简便、快捷,可准确测定虫草饲料添加剂地顶孢霉培养物中腺苷的含量。  相似文献   

12.
建立了羊肉组织中胺菊酯和三氟氯氰菊酯的固相萃取-反相高效液相色谱测定法。采用氟罗里硅土固相萃取柱(1000 mg/6 mL)进行固相萃取。以Shim-pack VP-ODS(200 mm×4.6 mm)柱为分析柱,流动相为甲醇:水=95:5(V/V),流速为0.7 mL/min。胺菊酯和三氟氯氰菊酯分别在0.01~6.40μg/mL(r=0.9999)和0.068~7.20ug/mL(r=0.9998)范围内与峰面积呈良好线性关系,检出限分别为0.001μg/mL和0.002μg/mL,胺菊酯和三氟氯氰菊酯的回收率为90.2%~101.4%,相对标准偏差为2.3%~4.0%。该方法可作为羊肉组织中胺菊酯和三氟氯氰菊酯含量监测的控制方法。  相似文献   

13.
A fast liquid chromatographic separation, coupled with sensitive and straightforward detection using a boron-doped diamond (BDD) electrode, was developed and validated for the determination of α-lipoic acid in dietary supplement samples. The analysis was carried out using a reversed phase C18 (150 mm × 4.6 mm, 5 μm) column with a mobile phase consisting of a 1:1 (v/v) ratio of 0.05 M phosphate solution (pH 2.5):acetonitrile, at a flow rate of 1.0 mL/min. The detection potential obtained from hydrodynamic voltammetry was 1.05 V vs. Ag/AgCl. Under optimized conditions, the chromatographic separation was performed in less than 5 min, a good linear relationship was obtained between the current and the α-lipoic concentration within the range of 0.01-60 μg/mL (correlation coefficient of 0.9971), and a detection limit of 3.0 ng/mL was determined. Furthermore, this method was successfully applied to determine α-lipoic acid concentrations in selected commercial dietary supplement samples. The recovery of α-lipoic acid in spiked samples at 0.5, 5.0 and 30 μg/mL ranged from 94.4% to 103.6% with a relative standard deviation (RSD) of between 1.2% and 3.7%. In real samples, this developed methodology produced results that were highly correlated with the standard HPLC-UV approach. Therefore, the present method can be used for fast, selective and sensitive quantification of α-lipoic acid in dietary supplements.  相似文献   

14.
建立了一种快速、准确的离子色谱法测定铬矿中氟含量的方法,将铬矿与石英砂混合,控制氧气和水蒸气的流量,于1 100℃高温下热水解30min,水解液经吸收后,选用Dionex AS11-HC阴离子分析柱,以KOH(20mmol/L)作淋洗液,自动再生抑制型电导检测器检测,离子色谱法测定铬矿中氟的含量。方法的检出限为0.022μg/mL,定量限为0.073μg/mL,方法的检测范围为0.0015%~0.20%,加标回收率在92%~101%。应用于实际样品的测定结果表明,铬矿中氟含量的测定值与标准方法的测定值一致。方法简单快速、检出限低、精密度高、准确度好。能满足铬矿中氟含量的快速准确检测要求。  相似文献   

15.
建立高效液相色谱法同时测定地表水中雌二醇、炔雌醇、雌酮、尼尔雌醇、苯甲酸雌二醇5种雌激素的残留量。水样经固相萃取柱富集,甲醇洗脱,以高效液相色谱法定量分析,5种雌激素分离良好。5种雌激素的质量浓度在0.08~4.00μg/m L范围内与色谱峰面积线性相关,相关系数均大于0.999;测定结果的相对标准偏差均小于5%(n=6);检出限分别为雌二醇0.04μg/m L,炔雌醇0.06μg/m L,雌酮0.03μg/m L,尼尔雌醇0.04μg/m L,苯甲酸雌二醇0.06μg/m L;加标回收率在87.6%~104.5%之间。该方法简单、灵敏、准确,可用于检测地表水中5种雌激素的残留量。  相似文献   

16.
建立超高效液相色谱法快速检测虾青素的方法。采用UPLC BEH C_8色谱柱(50 mm×2.1 mm,1.7μm),考察了流动相、流量及柱温对虾青素样品分离的影响,确定了最佳色谱条件:等度洗脱,流动相为甲醇–水(体积比为75∶25),流量为0.5 mL/min,柱温为40℃,检测波长为475 nm。虾青素的质量浓度在0.2~10.0μg/mL范围内与其色谱峰面积呈良好的线性关系,线性相关系数r=0.998 8,检出限(S/N=3)为0.1μg/mL,定量限(S/N=10)为0.2μg/mL。测定结果的相对标准偏差为0.41%(n=6),加标回收率为105.8%~110.3%。该方法快速、简单、可靠、灵敏、重复性好,可用于虾青素有关样品的快速检测。  相似文献   

17.
建立了超高效液相色谱-串联质谱(UPLC- MS/MS)测定食品包装材料中全氟辛烷磺酸盐(PFOS)的方法.采用乙腈作为溶剂,加速溶剂提取法提取食品包装材料中的PFOS.色谱条件:ACQUITY UPLC BEH C18色谱柱(1.7 μm,2.1 mm×50 mm);柱温:30 ℃;流动相:乙腈/水,梯度洗脱;流速:0.2 mL/min;经UPLC分离后用多级反应监测(MRM)方式测定.用2个子离子的相对丰度定性, 外标法定量.PFOS在0.005~0.500 μg/mL范围内线性良好(R2=0.999),PFOS的回收率为90.0%~101.6%,相对标准偏差RSD为1.5%~3.5%.方法检出限为0.1 μg/m2(S/N≥3).  相似文献   

18.
顶空气相色谱-质谱法测定土壤中丙烯腈的研究   总被引:3,自引:0,他引:3  
建立了用顶空气相色谱-质谱联用仪测定土壤中丙烯腈的方法.优化色谱-质谱联用仪和顶空仪对温度、时间等分析条件的设置,选用HP-INNOWAX(30 m×0.32 mm,0.50 μm)毛细管柱,在柱流速1.5 mL/min条件下采用电子轰击电离源,选择离子m/z 53进行外标法定量.该方法线性良好,相关系数r=0.999...  相似文献   

19.
胡忠阳  潘广文  叶明立 《色谱》2009,27(3):337-340
建立了一种同时测定离子液体中六氟磷酸根(PF~6)和痕量杂阴离子氟、氯、溴(F~,Cl~,Br~)的离子色谱方法(IC)。样品经溶解、稀释、过滤后用Dionex IonPac AS22分离柱(250 mm×4 mm)分离,淋洗液为碳酸盐-乙腈体系(体积比为70:30),流速1.0 mL/min,采用Dionex DS6电导检测器检测,外标法定量。F~,Cl~,Br~和PF~6的线性范围分别为0.5~50 μg/L、10~200 μg/L、10~200 μg/L和0.9~45 mg/L,线性相关系数分别为0.9999,0.9998,0.9999和0.9998,加标回收率为94.5%~100.5%,相对标准偏差为0.63%~1.03%,检出限(以信噪比为3计)分别为0.5 μg/L、2.0 μg/L、5.0 μg/L和0.9 mg/L。该方法用于离子液体中六氟磷酸根和痕量杂阴离子的同时测定,结果令人满意。  相似文献   

20.
Dimethylacetamide (DMA) is a solvent used in the preparation of intravenous busulfan, an alkylating agent used in blood or marrow transplantation. DMA may contribute to hepatic toxicity, so it is important to monitor its clearance. The aim of this study was to develop an HPLC‐UV assay for measurement of DMA in human plasma. After precipitation of plasma proteins with acetonitrile followed by dilution (1:4) with water, the extract was injected onto the HPLC and detected at 195 nm. Separation was performed using a Cogent‐HPS 5 μm C18 column (250 × 4.6 mm) preceded by a Brownlee 7 μm RP18, pre‐column (1.5 cm × 3.2 mm). The mobile phase was 25 mm sodium phosphate buffer (pH 3), containing 2.5% (v /v) acetonitrile and 0.0005% (v /v) sodium‐octyl‐sulfonate. Using a flow rate of 1 mL/min, the retention times of DMA and the internal standard (IS), 2‐chloroacetamide, were 9.5 and 3.5 min, respectively. Peak area ratio (DMA:IS) was a linear function of concentration from 1 to 1000 μg/mL. There was excellent intraday precision (<5% for 5–700 μg/mL DMA), accuracy (<3% deviation from the true concentration) and recovery (74–98%). The limits of detection and quantification were 1 and 5 μg/mL, respectively. In eight children who received intravenous busulfan, DMA concentrations ranged from 110 to 438 μg/mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号