首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe CHASE, a novel algorithm for automated de novo sequencing based on the mass spectrometric (MS) fragmentation analysis of tryptic peptides. This algorithm is used for protein identification from sequence similarity criteria and consists of four steps: (1) derivatization of tryptic peptides at the N-terminus with a negatively charged reagent; (2) post-source decay (PSD) fragmentation analysis of peptides; (3) interpretation of the mass peaks with the CHASE algorithm and reconstruction of the amino acid sequence; (4) transfer of these data to software for protein identifications based on sequence homology (Basic Local Alignment Search Tool, BLAST). This procedure deduced the correct amino acid sequence of tryptic peptide samples and also was able to deduce the correct sequence from difficult mass patterns and identify the amino acid sequence. This allows complete automation of the process starting from MS fragmentation of complex peptide mixtures at low concentration (e.g. from silver-stained gel bands) to identification of the protein. We also show that if PSD data are collected in a single spectrum (instead of the segmented mode offered by conventional matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) instrumentation), the complete workflow from MS-PSD data acquisition to similarity-based identification can be completely automated. This strategy may be applied to proteomic studies for protein identification based on automated de novo sequencing instead of MS or tandem MS patterns. We describe the Charge Assisted Sequencing Engine (CHASE) algorithm, the working protocol, the performance of the algorithm on spectra from MALDI-TOFMS and the data comparison between a TOF and a TOF-TOF instrument.  相似文献   

2.
The N-terminal sequence is important for the identification of a protein and the confirmation of its N-terminal processing. Although mass spectrometry (MS) is a sensitive and high-throughput method to sequence and identify peptides and proteins, N-terminal peptides, diluted among most of the peptides that do not originate at the N-termini, are not easy to identify directly with MS. To develop a simple and rapid method to identify and sequence the N-terminal peptide of a protein, a new strategy based on specific sulfonation of terminal amino groups and selective monitoring of the sulfonated peptide was introduced. After a protein had been guanidinated, 2-sulfobenzoylated, and reduced, it was digested with trypsin and analyzed by MS. Because of the strong acidity of sulfonic groups and the specific sulfonation of alpha-amino groups, the sulfonated N-terminal peptide dominated as base peak in the negative mode peptide mass fingerprint (PMF) and was easy to identify. The N-terminal peptide was then selected as precursor ion for tandem mass spectrometric (MS/MS) analysis. Four proteins were tested with this method and their N-terminal peptides were successfully recognized and sequenced. The results suggest that the addition of a sulfonic acid group facilitates the identification and de novo sequencing of N-terminal peptides.  相似文献   

3.
De novo analysis of protein N-terminal sequence is important for identification of N-terminal proteolytic processing such as N-terminal methionine or signal peptide removal, or for the genome annotation of uncharacterized proteins. We introduce a de novo sequencing method of protein N terminus utilizing matrix-assisted laser desorption/ionization (MALDI) signal enhancing picolinamidination with bromine isotopic tag incorporated to the N terminus. The doublet signature of bromine in the tandem mass (MS/MS) spectrum distinguished N-terminal ion series from C-terminal ion series, facilitating de novo N-terminal sequencing of protein. The dual advantage of MALDI signal enhancement by the basic picolinamidine and b-ion selection aided by Br signature is demonstrated using a variety of peptides. The N-terminal sequences of myoglobin and hemoglobin as model proteins were determined by incorporating the Br tag to the N terminus of the proteins and obtaining a series of b-ions with Br signature by MS/MS analysis after chymotryptic digestion of the tagged proteins. The N-terminal peptide was selected for MS/MS analysis from the chymotryptic digest based on the Br signature in the mass spectrum. Identification of phosphorylation site as well as N-terminal sequencing of a phosphopeptide was straightforward.  相似文献   

4.
Matrix-assisted laser desorption ionization (MALDI), Peptide Mass Fingerprinting (PMF) and MALDI-MS/MS ion search (using MASCOT) have become the preferred methods for high-throughput identification of proteins. Unfortunately, PMF can be ambiguous, mainly when the genome of the organism under investigation is unknown and the quality of spectra generated is poor and does not allow confident identification. The post-source decay (PSD) fragmentation of singly charged tryptic peptide ions generated by MALDI-TOF/TOF typically results in low fragmentation efficiency and/or complex spectra, including backbone fragmentation ions (series b and y), internal fragmentation etc. Interpreting these data either manually and/or using de novo sequencing software can frequently be a challenge. To overcome this limitation when studying the proteome of adult Angiostrongylus costaricensis, a nematode with unknown genome, we have used chemical N-terminal derivatization of the tryptic peptides with 4-sulfophenyl isothiocyanate (SPITC) prior to MALDI-TOF/TOF MS. This methodology has recently been reported to enhance the quality of MALDI-TOF/TOF-PSD data, allowing the obtainment of complete sequence of most of the peptides and thus facilitating de novo peptide sequencing. Our approach, consisting of SPITC derivatization along with manual spectra interpretation and Blast analysis, was able to positively identify 76% of analyzed samples, whereas MASCOT analysis of derivatized samples, MASCOT analysis of nonderivatized samples and PMF of nonderivatized samples yielded only 35, 41 and 12% positive identifications, respectively. Moreover, de novo sequencing of SPITC modified peptides resulted in protein sequences not available in NCBInr database paving the way to the discovery of new protein molecules.  相似文献   

5.
Matrix-assisted laser desorption ionization (MALDI), Peptide Mass Fingerprinting (PMF) and MALDI-MS/MS ion search (using MASCOT) have become the preferred methods for high-throughput identification of proteins. Unfortunately, PMF can be ambiguous, mainly when the genome of the organism under investigation is unknown and the quality of spectra generated is poor and does not allow confident identification. The post-source decay (PSD) fragmentation of singly charged tryptic peptide ions generated by MALDI-TOF/TOF typically results in low fragmentation efficiency and/or complex spectra, including backbone fragmentation ions (series b and y), internal fragmentation etc. Interpreting these data either manually and/or using de novo sequencing software can frequently be a challenge. To overcome this limitation when studying the proteome of adult Angiostrongylus costaricensis, a nematode with unknown genome, we have used chemical N-terminal derivatization of the tryptic peptides with 4-sulfophenyl isothiocyanate (SPITC) prior to MALDI-TOF/TOF MS. This methodology has recently been reported to enhance the quality of MALDI-TOF/TOF-PSD data, allowing the obtainment of complete sequence of most of the peptides and thus facilitating de novo peptide sequencing. Our approach, consisting of SPITC derivatization along with manual spectra interpretation and Blast analysis, was able to positively identify 76% of analyzed samples, whereas MASCOT analysis of derivatized samples, MASCOT analysis of nonderivatized samples and PMF of nonderivatized samples yielded only 35, 41 and 12% positive identifications, respectively. Moreover, de novo sequencing of SPITC modified peptides resulted in protein sequences not available in NCBInr database paving the way to the discovery of new protein molecules.  相似文献   

6.
Condensed phase protein sequencing typically relies on N-terminal labeling with phenylisothiocyanate ("Edman" reagent), followed by cleavage of the N-terminal amino acid. Similar Edman degradation has been observed in the gas phase by collision-activated dissociation of the N-terminal phenyl thiocarbamoyl protonated peptide [1] to yield complementary b1 and y(n-1) fragments, identifying the N-terminal amino acid. By use of infrared multiphoton (rather than collisional) activation, and Fourier transform ion cyclotron resonance (rather than quadrupole) mass analysis, we extend the method to direct analysis of a mixture of tryptic peptides. We validate the approach with bradykinin as a test peptide, and go on to analyze a mixture of 25 peptides produced by tryptic digestion of apomyoglobin. A b1+ ion is observed for three of the Edman-derivatized peptides, thereby identifying their N-terminal amino-acids. Search of the SWISS-PROT database gave a single hit (myoglobin, from the correct biological species), based on accurate-mass FT-ICR MS for as few as one Edman-derivatized tryptic peptide. The method is robust-it succeeds even with partial tryptic digestion, partial Edman derivatization, and partial MS/MS IRMPD cleavage. Improved efficiency and automation should be straightforward.  相似文献   

7.
A novel protein with factor Xa-like activity was isolated from Lonomia obliqua caterpillar spicules by gel filtration chromatography and reversed-phase high-performance liquid chromatography. The protein had a mass of 20745.7 Da, as determined by mass spectrometry, and contained four Cys residues. Enzymatic hydrolysis followed by de novo sequencing by tandem mass spectrometry was used to determine the primary structure of the protein and the cysteine residues linked by disulfide bridges. The positions of 24 sequenced tryptic peptides, including the N-terminal, were deduced by comparison with a homologous protein from the superfamily Bombycoidea. Approximately 90% of the primary structure of the active protein was determined.  相似文献   

8.
Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.  相似文献   

9.
A method has been developed for rapid and sensitive identification of epitope-containing peptides, based on direct MALDI-MS/MS analysis of epitope-containing peptides affinity bound to affinity beads. This technique provides sequence information of the epitope that allows unambiguous identification of the epitope either by database searching or de novo sequencing. With MALDI-MS, affinity beads with bound peptides can be placed directly on the MALDI target and analyzed. Coupling a MALDI source to an orthogonal injection quadrupole time-of-flight (QqTOF) mass spectrometer allows direct sequencing of the bound peptides. In contrast to ESI-MS/MS, elution of the affinity-bound peptides followed by additional concentration and purification steps is not required, thus reducing the potential for sample loss. Direct mass spectrometric sequencing of affinity-bound peptides eliminates the need for chemical or enzymatic sequencing. Other advantages of this direct MALDI-MS/MS analysis of epitope-containing peptides bound to the affinity beads include its sensitivity (femtomole levels) and speed. In addition, direct analysis of peptides on affinity beads does not adversely affect the high mass accuracy of a QqTOF, and database searching can be performed on the MS/MS spectra obtained. In proof-of-principle experiments, this method has been demonstrated on beads containing immobilized antibodies against phosphotyrosine, the c-myc epitope tag, as well as immobilized avidin. Furthermore, de novo sequencing of epitope-containing peptides is demonstrated. The first application of this method was with anti-FLAG-tag affinity beads, where direct MALDI MS/MS was used to determine an unexpected enzymatic cleavage site on a growth factor protein.  相似文献   

10.
Solid-phase sulfonation of tryptic peptides adsorbed to C18 muZipTips has been carried out to facilitate de novo sequencing with mass spectrometry. Peptides are reacted with the sulfonation reagent while they are still adsorbed to the solid phase. Excess reagent passes through the ZipTip to waste. Washing the products before subsequent elution from the mini-column also affords sample cleanup prior to analysis. Near quantitative N-terminal sulfonation can be achieved reliably at room temperature in only a few seconds. The method has been applied successfully to model peptides and to solution or in-gel digests of proteins. Current sequencing limits are about 100 fmol of protein. Multiplexed sample sulfonation reactions have been carried out with a manual 8-position micropipettor or using centrifugal force to reliably pass reagents and wash solutions over sample-loaded ZipTips. With multiplexing, overall preparation times have been reduced to about 1 min per sample. The solid-phase format facilitates efficient use of precious digest samples by enabling them to be recovered from the matrix-assisted laser desorption/ionization (MALDI) sample stage after mass fingerprinting, derivatized and re-analyzed by MALDI postsource decay mass spectrometry.  相似文献   

11.
Guanidination of the epsilon-amino group of lysine-terminated tryptic peptides can be accomplished selectively in one step with O-methylisourea hydrogen sulfate. This reaction converts lysine residues into more basic homoarginine residues. It also protects the epsilon-amino groups against unwanted reaction with sulfonation reagents, which can then be used to selectively modify the N-termini of tryptic peptides. The combined reactions convert lysine-terminated tryptic peptides into modified peptides that are suitable for de novo sequencing by postsource decay matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The guanidination reaction is very pH dependent. Product yields and reaction kinetics were studied in aqueous solution using either NaOH or diisopropylethylamine as the base. Methods are reported for derivatizing and sequencing lysine-terminated tryptic peptides at low pmole levels. The postsource decay (PSD) MALDI tandem mass spectra of a model peptide (VGGYGYGAK), the homoarginine analog and the sulfonated homoarginine analog are compared. These spectra show the influence that each chemical modification has on the peptide fragmentation pattern. Finally, we demonstrate that definitive protein identifications can be achieved by PSD MALDI sequencing of derivatized peptides obtained from solution digests of model proteins and from in-gel digests of 2D-gel separated proteins.  相似文献   

12.
A simple and effective method was developed for peptide sequencing and protein identification through the determination of its N-terminal residue. The method of N-terminal carbamidomethylation with iodoacetamide could specifically and remarkably enhance the intensity of a1 ions in the tandem mass spectra of the peptide derivatives without significantly altering their fragmentation pattern, thus allowing determination of their N-terminal residues. The effectiveness and specificity of the method was demonstrated by confirming and extending sequence interpretation of several model peptides and proteins. The developed method was then applied in the LC-MS/MS analysis of the tryptic digests of myoglobin and a whole protein extract from rat heart tissues. The results from database searches were well validated with the enhancement of a1 ions in tandem mass spectra and the specificity of protein identification was obtained when the information of N-terminal residues was included in the database search.  相似文献   

13.
A method for de novo sequencing of N(α)-blocked proteins by mass spectrometry (MS) is presented. The approach consists of enzymatic digestion of N(α)-blocked protein, recovery of N-terminal peptide by depletion of non-N-terminal peptides from the digest pool, and selective derivatization of a C-terminal α-carboxyl group of isolated N-terminal peptide. The C-terminal α-carboxyl group of the N-terminal peptide was selectively derivatized with 3-aminopropyl-tris(2,4,6-trimethoxyphenyl)phosphonium bromide (TMPP-propylamine), according to oxazolone chemistry. The reagent TMPP-propylamine was designed to facilitate sequence analysis with MALDI-MS by mass- and charge-tagging. All of the identities and N-terminal sequences of two N(α)-acetylated proteins (rabbit phosphorylase b and bovine calmodulin) and human orexin A, which has pyroglutamic acid at the N-terminus, were successfully analyzed by allowing for the y-type ions almost exclusively.  相似文献   

14.
A study has been undertaken to evaluate the usefulness of MALDI Q-TOF data for protein identification. The comparison of MS data of protein digests obtained on a conventional MALDI TOF instrument to the MS data from the MALDI Q-TOF reveal peptide patterns with similar intensity ratios. However, comparison of MS/MS Q-TOF data produced by nanoelectrospray versus MALDI reveals striking differences. Peptide fragment ions obtained from doubly charged precursors produced by nanoelectrospray are mainly y-type ions with some b-ions in the lower mass range. In contrast, peptide fragment ions produced from the singly charged ions originating from the MALDI source are a mixture of y-, b- and a-ions accompanied by ions resulting from neutral loss of ammonia or water. The ratio and intensity of these fragment ions is found to be strongly sequence dependent for MALDI generated ions. The singly charged peptides generated by MALDI show a preferential cleavage of the C-terminal bond of acidic residues aspartic and glutamic acid and the N-terminal bond of proline. This preferential cleavage can be explained by the mobile proton model and is present in peptides that contain both arginine and an acidic amino acid. The MALDI Q-TOF MS/MS data of 24 out of 26 proteolytic peptides produced by trypsin or Asp-N digestions were successfully used for protein identification via database searching, thus indicating the general usefulness of the data for protein identification. De novo sequencing using a mixture of 160/18O water during digestion has been explored and de novo sequences for a number of peptides have been obtained.  相似文献   

15.
通过在肽段的N端引入磺酸基,从而使含组氨酸的肽段与其他肽段在pH<3.0的条件下产生电荷差异,建立了一种基于强阳离子交换色谱(SCX)结合生物质谱富集鉴定含组氨酸肽段的方法,并以含有组氨酸的标准蛋白质为模型,进行了方法学考察。结果表明,经N端磺酸化后,含组氨酸的肽段能有效地被阳离子交换色谱富集,且在肽的N端引入磺酸基促进了肽的裂解,使之产生简单而信息丰富的二级质谱图,从而得到完美的质谱鉴定结果。这说明磺化修饰结合强阳离子交换色谱用于含组氨酸肽段的富集鉴定是可行的,且具有在蛋白质组研究中应用的潜力。  相似文献   

16.
A new method to determine N-terminal amino acid sequences of multiple proteins at low pmol level by a parallel processing has been developed. The method contains the following five steps: (1) reduction, S-alkylation and guanidination for targeted proteins; (2) coupling with sulfosucccimidyl-2-(biotinamido)ethyl-1,3-dithiopropionate(sulfo-NHS-SS-biotin) to N(alpha)-amino groups of proteins; (3) digestion of the modified proteins by an appropriate protease; (4) specific isolation of N-terminal fragments of proteins by affinity capture using the biotin-avidin system; (5) de novo sequence analysis of peptides by MALDI-TOF-/MALDI-TOF-PSD mass spectrometry with effective utilization of the CAF (chemically assisted fragmentation) method.1 This method is also effective for N-terminal sequencing of each protein in a mixture of several proteins, and for sequencing components of a multiprotein complex. It is expected to become an essential proteomics tool for identifying proteins, especially when used in combination with a C-terminal sequencing method.  相似文献   

17.
The relative quantification and identification of proteins by matrix‐assisted laser desorption ionization time‐of‐flight MS is very important in /MS is very important in protein research and is usually conducted separately. Chemical N‐terminal derivatization with 4‐sulphophenyl isothiocyanate facilitates de novo sequencing analysis and accurate protein identification, while 18O labeling is simple, specific and widely applicable among the isotopic labeling methods used for relative quantification. In the present study, a method combining 4‐sulphophenyl isothiocyanate derivatization with 18O isotopic labeling was established to identify and quantify proteins simultaneously in one experiment. Reaction conditions were first optimized using a standard peptide (fibrin peptide) and tryptic peptides from the model protein (bovine serum albumin). Under the optimized conditions, these two independent labeling steps show good compatibility, and the linear relativity of quantification within the ten times dynamic range was stable as revealed by correlation coefficient analysis (R2 value = 0.998); moreover, precursor peaks in MS/MS spectrum could provide accurate quantitative information, which is usually acquired from MS spectrum, enabling protein identification and quantification in a single MS/MS spectrum. Next, this method was applied to native peptides isolated from spider venoms. As expected, the de novo sequencing results of each peptide matched with the known sequence precisely, and the measured quantitative ratio of each peptide corresponded well with the theoretical ratio. Finally, complex protein mixtures of spider venoms from male and female species with unknown genome information were analyzed. Differentially expressed proteins were successfully identified, and their quantitative information was also accessed. Taken together, this protein identification and quantification method is simple, reliable and efficient, which has a good potential in the exploration of peptides/proteins from species with unknown genome. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Optimized procedures have been developed for the addition of sulfonic acid groups to the N-termini of low-level peptides. These procedures have been applied to peptides produced by tryptic digestion of proteins that have been separated by two-dimensional (2-D) gel electrophoresis. The derivatized peptides were sequenced using matrix-assisted laser desorption/ionization (MALDI) post-source decay (PSD) and electrospray ionization-tandem mass spectrometry methods. Reliable PSD sequencing results have been obtained starting with sub-picomole quantities of protein. We estimate that the current PSD sequencing limit is about 300 fmol of protein in the gel. The PSD mass spectra of the derivatized peptides usually allow much more specific protein sequence database searches than those obtained without derivatization. We also report initial automated electrospray ionization-tandem mass spectrometry sequencing of these novel peptide derivatives. Both types of tandem mass spectra provide predictable fragmentation patterns for arginine-terminated peptides. The spectra are easily interpreted de novo, and they facilitate error-tolerant identification of proteins whose sequences have been entered into databases.  相似文献   

19.
Recently various methods for the N-terminal sulfonation of peptides have been developed for the mass spectrometric analyses of proteomic samples to facilitate de novo sequencing of the peptides produced. This paper describes the isotope-coded N-terminal sulfonation (ICenS) of peptides; this procedure allows both de novo peptide sequencing and quantitative proteomics to be studied simultaneously. As N-terminal sulfonation reagents, 13C-labeled 4-sulfophenyl[13C6]isothiocyanate (13C-SPITC) and unlabeled 4-sulfophenyl isothiocyanate (12C-SPITC) were synthesized. The experimental and reference peptide mixtures were derivatized independently using 13C-SPITC and 12C-SPITC and then combined to generate an isotopically labeled peptide mixture in which each isotopic pair differs in mass by 6 Da. Capillary reverse-phase liquid chromatography/tandem mass spectrometry experiments on the resulting peptide mixtures revealed several immediate advantages of ICenS in addition to the de novo sequencing capability of N-terminal sulfonation, namely, differentiation between N-terminal sulfonated peptides and unmodified peptides in mass spectra, differentiation between N- and C-terminal fragments in tandem mass spectra of multiply protonated peptides by comparing fragmentations of the isotopic pairs, and relative peptide quantification between proteome samples. We demonstrate that the combination of N-terminal sulfonation and isotope coding in the mass spectrometric analysis of proteomic samples is a viable method that overcomes many problems associated with current N-terminal sulfonation methods.  相似文献   

20.
磺基异硫氰酸苯酯化学辅助方法对新蛋白质进行从头测序   总被引:1,自引:0,他引:1  
利用基质辅助激光解吸电离-串联飞行时间(MALDI-TOF-TOF)质谱结合磺基异硫氰酸苯酯化学辅助的方法对一种从拟青霉(Paecilomyces bainier)分离纯化到的新人参皂苷Rb1水解酶的部分肽段进行了从头测序. 共获得了这个新蛋白质8条肽段的序列, 一些磺化后信噪比非常低的肽段也获得了比较完整的序列. 同时通过从头测序分析确定了一对甲硫氨酸非氧化和氧化肽段的序列. 结果表明, 磺化后的肽段离子化效率大大增强, 在PSD(源后裂解)过程中只有肽键断裂产生的C端的碎片离子系列(y离子系列)出现在质谱图中, 图谱背景清晰, 信噪比高, 单纯的y离子系列使得图谱解析变得非常容易. 将这8条序列在NCBI(美国国立生物技术信息中心)数据库中进行BLAST(蛋白质序列比对工具)检索印证这种β-葡萄糖甘酶是一个新蛋白质, 发现的两条相对保守的序列为进一步研究奠定了基础.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号