首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Some selection criteria and experimental considerations for selecting an internal standard in flame atomic absorption spectrometry were studied. Rational criteria for the selection of internal standards include the atomization efficiencies of the elements. An experimental study of the variation of the atomization degree due to a temperature decrease can be made with the help of plots of absorbance against the rate at which the sample solution is introduced. The temperature decrease produced by increasing the rate at which water was introduced using a heated chamber without water-cooled condenser was estimated to vary from 2420 K to 2218 K with 1.0 ml water per minute. Curves for the alkali, alkaline earth, and several other metals were obtained in the air-acetylene flame. The shapes of the curves are critically dependent on the degree of atomization of the metal itself. Elements with curves that have similar slopes can be used as mutual internal standards. Some of the other factors which affect the atomization efficiencies—i.e. changes in fuel and air flow, and matrix composition—were also studied.  相似文献   

2.
The interference of the organophosphorus acids, 1-hydroxyethane-1,1-bisphosphonic acid, aminotris(methylenephosphonic acid), ethylenediaminetetrakis(methylenephosphonic acid) and hexamethylenediaminetetrakis(methylenephosphonic acid) on the determination of eighteen metal ions by flame atomic absorption spectrometry is reported. Comparisons with the effect of orthophosphoric acid reveal similarities and distinct differences in their interfering effects. In the air/acetylen flame, depressive interferences are attributed to the formation of phosphates, M3(PO4)2, or hydroxynpatite-like compounds, M5(OH)(PO4)3, in the flame aerosol particles for Mg, Ca, Sr, Ba, Mn, Co and Ni. Iron(III) and chromium(III) appear to form stable oxide phosphates, M2O3?MPO4 or M3O4?MPO4. Evidence for the formation of stable molybdenum carbides, MoC and MoC2, is also presented. In the nitrous oxide/acetylene flame, serious interferences perssisted only for molybdenum but were eliminated by the addition of sodium sulphate.  相似文献   

3.
In thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) a nickel atomization tube is placed in the acetylene/air flame on a holder built onto a standard AAS burner head. The liquid to be analyzed is transported by a low or high-pressure pump through a very hot, simple, inexpensive ceramic capillary tip acting as a flame-heated thermospray into the flame furnace. This results in complete sample introduction and increases the residence time of the sample in the absorption volume. This leads for 17 elements to a 3-110-fold improvement in the power of detection compared to conventional flame AAS. The absolute detection limits (3s values, N=25) lie between 0.2 μg l−1 (Zn) and 310 μg l−1 (Se) according to the element. The R.S.D. (N=15) is 1.4-5.5% according to the element and applied concentration. TS-FF-AAS can easily be incorporated on any standard flame AAS instrument and can be automated with a standard autosampler.  相似文献   

4.
A hydride generation flame atomic absorption spectrometric method was developed and optimized to quantitate arsenic (As) in foods. A wet digestion of the samples with HNO3 + H2O2 was performed and excess oxidants were eliminated by addition of hydrochloric acid and urea. As5+ in As3+ was then reduced by potassium iodide. The As3+ solution was analyzed by generation of arsine with sodium tetrahydroborate. As determination ranged from 2.5 to 20 microg/L, with a determination coefficient of 0.997. The limits of detection (LOD) and quantitation (LOQ) were 0.6 and 2.1 microg/L, respectively. The method was validated and good results were obtained for recovery, precision, accuracy, LOD, and LOQ. This method is now used to analyze foods from Rwanda.  相似文献   

5.
A method is described for the determination of Tl in soils by FAAS, involving extraction of Tl from 5 g of soil by digestion with HClO4/HNO3 followed by separation of the extracted Tl into 5 mL of diisopropylether from HBr solution, including Ce(SO4)2. Tl in the organic phase is determined by direct aspiration into the spectrophotometer. The percentage relative standard deviation (% RSD) for 5 replicate samples is about 1%. The detection limits (S/N = 3) of this method are 0.001 mg/L for aqueous solution and 0.02 mg/kg DW for soil, when 50 mL of soil solution corresponding to 2.5 g soil are used. The Tl concentration even of unpolluted soils can be determined. The method was shown to be unaffected by the presence of various ions in soil and was able to recover nearly 100% Tl added to soils. The arithmetic mean (range) of 18 Japanese unpolluted surface soils was 0.33 (0.10–0.56)mgTl/kg DW.  相似文献   

6.
基于钨丝电热蒸发设备,建立了一种全新的钨丝电热蒸发-氩/氢火焰串联原子吸收光谱系统.研究了系统抗酸、抗盐能力,结果表明:Na<'+>和Ca<'2+>质量浓度小于400 mg/L、Mg<'2+>质量浓度小于1500 mg/L时不干扰测定.在优化的仪器条件下:Pb、Cd、Au和Ag的检出限分别为:0.016、0.0005、...  相似文献   

7.
原子吸收、原子荧光和火焰光谱分析   总被引:3,自引:0,他引:3  
本文主要根据1993年4月~1994年10月国内重要分析刊物所发表的文章以及在此期间召开的重要全国性会议的主要论文,对我国原子吸收光谱法、原子荧光光谱法及火焰发射光谱法的进展作一综述。文中共收集文献528篇。  相似文献   

8.
9.
A manifold is described which allows continuous liquid/liquid extraction of aqueous solutions of metal ions. A fraction of the organic stream is separated and led into the sample loop of an injector. The injector is situated in an aqueous carrier stream which is pumped into the nebulizer. The organic extract enters as an undispersed plug into the carrier when the valve is actuated. A preconcentration factor of 5.5 resulting in a correspondent sensitivity increase is readily obtained for aqueous samples.  相似文献   

10.
Two manifolds allowing the automation of the standard additions method in flame atomic absorption spectrometry by using two computer-controlled variable-speed peristaltic pumps operating in a programmed way are presented in this article. One of the pumps increases and the other decreases its turning speed linearly with time, so that the flow-rate supplied to the nebulizer is constant. In the first manifold, one pump moves the sample solution, while the other pump propels a standard solution, so that a continuously changing on-line mixture of both the solutions is obtained. In the second manifold, both pumps, one of which also pumps a standard solution, while the other pumps a diluent solution, propel the sample solution. This second manifold that exactly reproduces the standard additions method, is automatic and allows releaser solutions to be used. Both the procedures present the additional advantage over the conventional batch procedure of the very high number of data that can be acquired by the computer. The theoretical background of both manifolds is presented and their correct operation is experimentally verified.  相似文献   

11.
建立火焰原子吸收光谱法测定锌合金中镁含量。选用10 mL盐酸溶液(1+1)溶解样品,加入5 mL质量浓度为100 g/L的LaCl3溶液,以消除铝对镁的化学干扰,在选定的仪器工作条件下进行测定。结果表明,镁的质量浓度在0~1.238 mg/L范围内与与吸光度具有良好的线性关系,相关系数为0.999 4,线性方程为Y=1.086 4X+0.018 5,方法测定下限为0.010 mg/L。样品测定结果的相对标准偏差为1.61%~3.45%(n=6),加标回收率为91.3%~94.7%。该方法准确度高,精密度好,满足锌合金中镁含量的日常检测要求。  相似文献   

12.
本文利用高碘酸钠对相邻羟基氧化作用的专属性,在一定介质中,高碘酸钠与核黄素完全反应后,过量的高碘酸的钠与硝酸铅或者硝酸铜生成沉淀,通过测定Pb<'2+>或者Cu<'2+>,建立了间接测定核黄素含量的方法.铅体系和铜体系测定的相对标准偏差(RSD)分别为4.8%和5.2%,检出限分别为0.6μg.mL<'-1>和0.5μ...  相似文献   

13.
The behavior of selenium in thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was studied and the developed procedure was applied for selenium determination in biological materials after microwave-assisted sample digestion. A sample volume of 600 μL was introduced into the hot metallic Ni tube at a flow rate of 0.4 mL min−1 using water as carrier. The limit of detection obtained for Se was 8.7 μg L−1 (3sblank/slope, n = 10), which is 95-fold better than that typically obtained using FAAS. The applicability of the TS-FF-AAS procedure was evaluated for selenium determination in biological materials. Certified reference materials of pig kidney (BCR 186) and mussel (GBW 08571) were analyzed and a t-test had not shown any statistically significant difference at a 95% confidence level between determined and certified values for both materials. The procedure was successfully applied for determination of Se in pig kidney and shellfish. It was demonstrated that TS-FF-AAS improved the performance of FAAS (flame atomic absorption spectrometry) for determination of Se.  相似文献   

14.
炭末中银的准确测定对于其金属平衡和贸易结算具有重要意义。采用硝酸-硫酸体系除碳分解试样,在20%盐酸介质中,采用空气-乙炔火焰,以328.1nm作为测定波长,建立了火焰原子吸收光谱法(FAAS)测定炭末中银的方法。在最优的实验条件下,银质量浓度在0.30~3.00μg/mL范围内与其吸光度呈良好线性关系,相关系数为0.9999。方法检出限为0.004μg/mL,定量下限为0.013μg/mL。干扰试验表明,根据炭末中干扰元素含量,在载金炭国家标准物质中加入一定量的共存元素,共存元素不影响银量的测定。实验方法用于测定实际炭末样品中银,结果的相对标准偏差(RSD,n=7)为0.91%~3.4%,且结果与《GB∕T 29509.2-2013 载金炭化学分析方法 第2部分:银量的测定 火焰原子吸收光谱法》方法测定结果一致。按照实验方法测定了4个载金炭标准样品中银,结果与标准值吻合。准确度和精密度符合实际生产需求,可用于炭末中银的测定。  相似文献   

15.
Flame atomic absorption spectrometry (FAAS) is an accepted and widely used method for the determination of trace elements in a great variety of samples. But its sensitivity doesn’t meet the demands of trace and ultra-trace analysis for some samples. The derivative signal processing technique, with a very high capability for enhancing sensitivity, was developed for FAAS. The signal models of conventional FAAS are described. The equations of derivative signals are established for FAAS, flow injection atomic absorption spectrometry (FI-FAAS) and atom trapping flame atomic absorption spectrometry (AT-FAAS). The principle and performance of the derivative atomic absorption spectrometry are evaluated. The derivative technique based on determination of variation rate of signal intensity with time (dI/dt) is different from the derivative spectrophotometry (DS) based on determination of variation rate of signal intensity with wavelength (dI/dλ). Derivative flame atomic absorption spectrometry (DFAAS) has higher sensitivity, lower detection limits and better accuracy. It has been applied to the direct determination of trace elements without preconcentration. If the derivative technique was combined with several preconcentration techniques, the sensitivity would be enhanced further for ultra-trace analysis with good linearity. The applications of DFAAS are reviewed for trace element analysis in biological, pharmaceutical, environmental and food samples.  相似文献   

16.
17.
The flow-injecton preconcentration of lead with immobilised reagents under a variety of conditions is discussed. Timed sample loading and matrix removal without passing the matrix to the nebuliser were achieved simply with one valve. Reagent consumption and calibration time were reduced by the addition of further valves. A system design incorporating control of the timing of operations by a commercial autosample is described. The effects of pH and interferent ions were examined. Water samples were analysed against aqueous standards and as standard additions solutions. For an analysis time of about 3 min a preconcentration factor of about 40 was obtained for both peak height and area measurements. Detection limits of down to 1.4 ml?1 were obtained.  相似文献   

18.
A continuous-flow procedure is proposed for the indirect determination of ascorbic acid, based on its reducing properties because of the oxidation of its 1,2-enediol group. Iron(III) was injected into a 1,10-phenanthroline stream, which was mixed with a sample carrier and then with a sodium picrate solution stream. In these conditions the iron(III) was reduced to iron(II) by the ascorbic acid. Thus, the iron(II) formed reacts with 1,10-phenanthroline to form a charged red complex, which with picrate ion forms a stable red-orange uncharged ion-association complex that is adsorbed on-line on a non-ionic polymeric adsorbent (Amberlite XAD-4), proportionally to the ascorbic acid in the sample. The unadsorbed iron was determined by flame atomic absorption spectrometry. The proposed method allows the determination of ascorbic acid in the range 0.5–25 g ml–1 with a relative standard deviation of 2.9% at a rate of ca. 90 samples h–1. This method has been applied to the determination of ascorbic acid in pharmaceutical preparations, fruit juices and sweets. The results obtained in the analysis are compared with those provided by the 2,6-dichloroindophenol method.  相似文献   

19.
鸡尾木(ExcoecariaVenenataS.LeeetF.N.Wei)属大戟科,海漆属,为民间药用珍贵植物,用于治疗牛皮癣、慢性湿疹等,疗效颇佳[1]。鸡尾木中无机元素,尤其是医学微量元素的测定对其药理效的研究有重要的参考价值。1 实验部分1 1 仪器及试剂TAS 986原子吸收分光光度计(北京普析通用仪器有限责任公司);空心阴极灯:Fe、Cu、Ni、Cr、Cd、Zn、Co、Ba、Ca(北京瑞利普光电器厂);Mg、Pb(北京真空电子技术总公司);Mn(北京市朝阳天宫电器厂);AdventurerTM电子天平(奥豪斯国际贸易〈上海〉有限公司)。标准储备液:配制Zn2+、Mg2+、Fe3+、Mn2…  相似文献   

20.
火焰原子吸收光谱法测定软儿梨中微量元素   总被引:2,自引:0,他引:2  
采用火焰原子吸收光谱法测定了软儿梨果肉和果汁中K、Mg、Fe、Ca、Mn、Cu、Zn的含量.样品以HNO3-HClO4消解,对消解和仪器测定条件进行了优化选择,建立了相应的原子吸收光谱测定方法.方法的RSD在1.0%~3.0%之间,加标回收率在90%~100%之间.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号