首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The solid-phase extraction (SPE) method for the preconcentration of trace amounts of cadmium using synthetic zeolite A-4 and its determination by graphite furnace atomic absorption spectrometry (GFAAS) was investigated. The preconcentration conditions, such as the optimum pH range of the sample solution for the adsorption of cadmium and the kind of acid solution for dissolving the cadmium-adsorbed synthetic zeolite A-4, as well as the measurement conditions for the determination of cadmium by GFAAS, e.g., the ashing and atomizing temperature, were investigated. Quantitative recovery of cadmium onto zeolite A-4 from the sample solution over the pH range 2.0 - 9.0 was achieved by the batch method. After the solid-phase (cadmium-adsorbed zeolite A-4) was separated from the sample solution by a membrane filter, it was dissolved in 2.0 cm(3) of 2.0 mol dm(-3) nitric acid. An aliquot of the resulting solution was injected into the graphite furnace. In GFAAS measurements an alternate gas (Ar, 90%; O(2), 10%) was used as a sheath gas, and the ashing temperature and atomizing temperature were 400 degrees C and 1600 degrees C, respectively. The detection limit (3 sigma) for cadmium was 0.002 microg dm(-3). The relative standard deviation at 0.010 microg dm(-3) was 3.5 - 4.5% (n = 5). The proposed method has been successfully applied to the analysis of trace cadmium in environmental water samples.  相似文献   

2.
A sensitive and simple method for the determination of trace amounts of indium in water samples by graphite furnace atomic absorption spectrometry (GFAAS) after coprecipitation with chitosan was investigated. Indium was quantitatively preconcentrated from water samples by coprecipitation with chitosan at pH 7.0-9.0. The coprecipitant was easily dissolved with acetic acid, and indium in the resulting solution was determined by GFAAS. The addition of lanthanum as a chemical modifier was more effective for the atomic absorbance of indium. The detection limit (S/N > or = 3) for indium was 0.04 microg dm(-3), and the relative standard deviations (n = 5) were 3.5-4.5% at 1.0 microg/100 cm3. The results obtained in this study indicate that the proposed method can be successfully applied to the determination of trace indium in water samples.  相似文献   

3.
The cloud-point methodology was successfully employed for the preconcentration of heavy metal cations at trace levels from aqueous samples prior to flame atomic absorption spectrometry (FAAS). Cations were taken into a complex with 8-quinolinol in an aqueous non-ionic surfactant, Triton X-114, medium and concentrated in the surfactant rich phase by bringing the solution to the cloud-point temperature. The preconcentration of only 100 mL of the solution with 1% Triton X-114 and 10(-3) M 8-quinolinol at pH 7.0 gave a preconcentration factor higher than 100 for most cations. Under these conditions, the detection limits of the cloud-point extraction-FAAS system were 0.8 - 15 microg/L.  相似文献   

4.
A novel method for cobalt preconcentration by cloud point extraction with on-line phase separation in a PTFE knotted reactor and further determination by electrothermal atomic absorption spectrometry (ETAAS) is proposed. The cloud point system was formed in the presence of non-ionic micelles of polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) and it was retained on the inner walls of a knotted reactor (KR). The surfactant rich-phase was removed from the knotted reactor with 75 microL of methanol acidified with 0.8 mol L(-1) nitric acid, directly into the dosing hole of the L'Vov graphite tube. An enrichment factor of 15 was obtained with a preconcentration time of 60 s, with respect to the direct determination of cobalt by ETAAS in aqueous solutions. The value of the detection limit for the preconcentration of 5 mL of sample solution was 10 ng L(-1). The precision, expressed as the relative standard deviation (R.S.D.), for 10 replicate determinations at 0.5 microg L(-1) Co level was 4.5%. Verification of the accuracy was carried out by analysis of a standard reference material (NIST SRM 1640e "Trace elements in natural water"). The method was successfully applied to the determination of cobalt in drinking water samples.  相似文献   

5.
A procedure for the determination of trace amount of cadmium after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been proposed. This chelate is adsorbed on the adsorbent in the pH range 3-8 from large volumes of aqueous solution of water samples with a preconcentration factor of 200. After being sorbed, cadmium was eluted by 5 mL of 2.0 mol L(-1) nitric acid solution and determined directly by flame atomic absorption spectrophotometery (FAAS). The detection limit (3sigma) of cadmium was 0.32 microg L(-1). The precision of the proposed procedure, calculated as the relative standard deviation of recovery in sample solution (100 mL) containing 5 microg of cadmium was satisfactory (1.9%). The adsorption of cadmium onto adsorbent can formally be described by a Langmuir equation with a maximum adsorption capacity of 19.6 mg g(-1) and a binding constant of 6.5 x 10(-3) L mg(-1). Various parameters, such as the effect of pH and the interference of a number of metal ions on the determination of cadmium, have been studied in detail to optimize the conditions for the preconcentration and determination of cadmium in water samples. This procedure was applied to the determination of cadmium in tap and river water samples.  相似文献   

6.
A reliable procedure for the electrothermal atomic absorption spectrometry (ETAAS) determination of gold and silver in waters at trace level is described. The method is based on prior separation and preconcentration of the metals using a chelating sorbent SPHERON® Thiol 1000 after acidification of water samples (pH < 3) with nitric acid. Optimization of analytical variables during enrichment and ETAAS determination of the metals are discussed. The accuracy of the method is verified by analysis of certified reference materials. The limits of determinations based on 10 σ definition were 0.005 ng cm?3 for Au and 0.02 ng cm?3 for Ag. Precision of studied elements determination expressed by relative standard deviation varied in the range from 2.9 % to 16.4 %.  相似文献   

7.
Electrodeposition is known to be suitable for separation and preconcentration of extremely low concentrations of analyte from bulk samples and is instrumentally is very simple. In this approach a new combined system was designed for in-situ electrodeposition of ultratrace levels of gold from micro samples on to a graphite furnace prior to determination by electrothermal atomic absorption spectrometry (ETAAS). Sediment samples were digested and traces of the gold content were extracted with boiling aqua regia. To prevent the highly corrosive effect of aqua regia media, the graphite tube surface was pre-coated by electrodeposition of ppm amounts of Pd prior to sample introduction. Separation of the analyte from the matrix was achieved by electrodeposition of the analyte in situ on the Pd/C surface of the furnace tube. Vanadium was also used as a modifier to stabilize the analyte from decomposition at charring temperatures. By using the proposed microelectrolysis preconcentration technique a considerable improvement in sensitivity and detection limit was achieved compared with conventional ETAAS. Characteristic masses for ED-ETAAS techniques in both nitric acid and aqua regia were reported to be m(o)=4.1 pg, with %RSD=2.9; the calculated LOD was 0.105 ppb, and typical calibration graphs for this element in nitric acid and aqua regia for both techniques were linear up to 70 microg L(-1) with about 99% recovery. Six reference sediments samples were tested by the proposed technique and by the Conv-ETAAS method. The results were in agreement with recommended values (reported by a reference laboratory using UV-visible spectrometry), demonstrating the efficiency of extraction and preconcentration of ultratrace levels of gold.  相似文献   

8.
A flow injection on-line sorption preconcentration system has been synchronously coupled to an electrothermal atomic absorption spectrometry (ETAAS) system for the selective determination of trace amounts of Sb(III) in water, soil and plant. The determination was achieved by selective complexation and sorption of Sb(III) with [1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydarzide (PSTH) immobilized on an anion-exchange resin (Dowex 1× 8-200)] at a wide range of pH, quantitative elution with 50 μl of 2 M HNO3 and subsequent ETAAS detection. ETAAS determination of the analyte was performed in parallel with the preconcentration of the next sample. Using a preconcentration time of 60 s and a sample loading flow rate of 2.8 ml min−1, an enhancement factor of 12 was obtained in comparison with direct injection of 50 μl aqueous solution, resulting in a sampling frequency of 31 samples h−1. The detection limit (3 s) was 2 μg l−1 and the precision was 3.1% (R.S.D.) for 11 replicate determinations at 10 μg l−1. The accuracy of the proposed method was demonstrated by analyzing one certified sample and different spiked samples.  相似文献   

9.
A determination method for lead in waste water and effluent was studied using flame atomic absorption spectrometry after preconcentration of lead by the rapid coprecipitation technique with gallium phosphate. Lead ranging from 0.5 to 50 microg was quantitatively coprecipitated with gallium phosphate from 100-150 mL sample solution (pH approximately 5). The presence of gallium phosphate did not affect the atomic absorbance of lead. Since the concentration of gallium in the final sample solution is also measurable by flame atomic absorption spectrometry at 250.0 nm without further dilution, the rapid coprecipitation technique, which does not require complete collection of the precipitate, becomes possible using a known amount of gallium and measuring the concentrations of both lead and gallium in the final sample solution by flame atomic absorption spectrometry. The 32 diverse ions tested gave no significant interferences in the lead determination. The method proposed here is rapid and has good reproducibility.  相似文献   

10.
Coprecipitation with terbium hydroxide quantitatively recovered trace amounts of chromium(III), copper(II) and lead(II) at pH 8.4 - 10.8, 8.0 - 11.5 and 8.7 - 11.5, respectively. The precipitate was dissolved in 0.85 mol dm(-3) nitric acid, and the analytes were determined by graphite-furnace atomic absorption spectrometry (GF-AAS). The presence of terbium (up to 7 g dm(-3)) did not interfere with the determination. The detection limits were 0.3 microg dm(-3) for chromium, 0.4 microg dm(-3) for copper and 0.5 microg dm(-3) for lead, when the analytes in 200 cm3 of the sample solution were concentrated into 10 cm3. The ions added to river or seawater were quantitatively recovered. Chromium and copper in a contaminated river water were successfully determined.  相似文献   

11.
A laboratory constructed molybdenum tube atomizer was used for direct determination of trace cadmium in drug samples by the electrothermal atomic absorption spectrometric (ETAAS) method. An ultrasonic agitation method for a solution including the sample powder was used. A calibration curve was constructed with a cadmium standard solution including matrix. To eliminate interference from other matrix elements, a chemical modifier thiourea, was used. The detection limit were 17 pg ml(-1) (3 S/N), and the RSD of the direct analysis was 5-17%. The results for cadmium in the four drug samples analysed by the direct ETAAS method matched well with those obtained with nitric acid digested samples. The recovery of added cadmium was 103-106%. An accurate method is elaborated for the determination of cadmium in drug samples by direct ETAAS techniques. The merits of this method are rapid calibration, simplicity, fast analysis, and low cost.  相似文献   

12.
Co(III) hexamethylenedithiocarbamate has been applied as a collector in colloid flotation preconcentration of Cd from water prior to electrothermal atomic absorption spectrometry (ETAAS). All experimental parameters necessary for successful flotation have been studied and optimized. The ETAAS results were compared with those obtained by inductive coupled plasma-atomic emission spectrometry (ICP-AES). The ETAAS detection limit was found to be 0.003 microg L(-1) Cd.  相似文献   

13.
A flow injection on-line sorption preconcentration electrothermal atomic absorption spectrometric system for fully automatic determination of lead in water was investigated. The discrete non-flow-through nature of ETAAS, the limited capacity of the graphite tube and the relatively large volume of the knotted reactor (KR) are obstacles to overcome for the on-line coupling of the KR sorption preconcentration system with ETAAS. A new FI manifold has been developed with the aim of reducing the eluate volume and minimizing dispersion. The lead diethyldithiocarbamate complex was adsorbed on the inner walls of a knotted reactor made of PTFE tubing (100 cm long, 0.5 mm i.d.). After that, an air flow was introduced to remove the residual solution from the KR and the eluate delivery tube, then the adsorbed analyte chelate was quantitatively eluted into a delivery tube with 50 μl of ethanol. An air flow was used to propel the eluent from the eluent loop through the reactor and to introduce all the ethanolic eluate onto the platform of the transversely heated graphite tube atomizer, which was preheated to 80°C. With the use of the new FI manifold, the consumption of eluent was greatly reduced and dispersion was minimized. The adsorption efficiency was 58%, and the enhancement factor was 142 in the concentration range 0.01–0.05 μg l−1 Pb at a sample loading rate of 6.8 ml min−1 with 60 s preconcentration time. For the range 0.1–2.0 μg l−1 of Pb a loading rate of 3.0 ml min−1 and 30 s preconcentration time were chosen, resulting in an adsorption efficiency of 42% and an enhancement factor of 21, respectively. A detection limit (3σ) of 2.2 ng l−1 of lead was obtained using a sample loading rate of 6.8 ml min−1 and 60 s preconcentration. The relative standard deviation of the entire procedure was 4.9% at the 0.01 μg l−1 Pb level with a loading rate of 6.8 ml min−1 and 60 s preconcentration, and 2.9% at the 0.5 μg l−1 Pb level with a 3.0 ml min−1 loading rate and 30 s preconcentration. Efficient washing of the matrix from the reactor was critical, requiring the use of the standard addition method for seawater samples. The analytical results obtained for seawater and river water standard reference materials were in good agreement with the certified values.  相似文献   

14.
An electrothermal atomic absorption (ETAAS) method for the determination of traces of iron (0.1-1.0 microgram g-1) in Fe-doped indium phosphide (InP) has been developed. In order to overcome the indium matrix-effect and to achieve a useful detection limit, a preliminary solvent-extraction of Fe(III) with acetylacetone (HAA) is necessary. After sample dissolution with hydrochloric acid (1 + 1) the digest is evaporated to dryness, Fe(II) is oxidized to Fe(III) with nitric acid, the residue is dissolved in 0.01 mol L-1 HCl and the iron is extracted at pH 2.0 with 0.5 mol L-1 HAA in toluene. The organic phase is injected into the graphite furnace and the iron is directly evaluated by external organic standard calibration. The limit of detection (3SB) resulting from further in-situ preconcentration is 0.03 microgram g-1. When the method was applied to the analysis of real samples containing 0.2-0.7 microgram g-1 Fe, the RSD was in the range 8-21%. Results were compared with those independently obtained on the decomposed sample solution with inductively coupled atomic emission spectrometry (ICP-AES). The detection limit of the ICP-AES method, that needs matrix-matched standards, is 0.20 microgram g-1.  相似文献   

15.
A method of determining trace levels of platinum and rhodium in different samples was investigated. The method involves separation and preconcentration of the platinum and rhodium from the matrix by flow injection (FI) on-line coupled with electrothermal atomic absorption spectrometry (ETAAS) with Zeeman effect background correction. Platinum and rhodium were adsorbed on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The sorbed metals were directly eluted with nitric acid into the graphite furnace and determined by AAS.  相似文献   

16.
Y Cai  G Jiang  J Liu 《The Analyst》2001,126(10):1678-1682
The adsorption characteristics of five commercially available Chromosorb GC stationary phases towards Cd2+ and their application to the preconcentration and ETAAS determination of Cd2+ in several water samples were studied. The experimental results indicated that although all of the five Chromosorb GC stationary phases studied can retain Cd2+ quantitatively from aqueous solutions at appropriate pH values without adding chelating reagent. Chromosorb 105 displayed the highest adsorption capacity. A highly sensitive, simple methodology for preconcentration and ETAAS determination of trace amounts of cadmium in natural water samples using a Chromosorb 105 packed minicolumn is proposed. Conditions for quantitative and reproducible preconcentration, elution and subsequent ETAAS determination were established. The high retention efficiency (> 95%) for Cd2+ provides a sensitivity enhancement of 100-fold for a 200 mL sample volume with a detection limit of 6.2 ng L(-1) (3 sigma).  相似文献   

17.
Two methods have been developed for the determination of boron impurities in silicon-doped gallium arsenide (GaAs) for electronics. The first method employs the electrothermal atomic absorption spectrometry (ETAAS), the second, the UV-Vis molecular absorption spectrophotomety. In both cases the GaAs sample is decomposed with aqua regia (1+1). To prevent Ga(III) interference on the ETAAS determination of boron, a double extraction of the chlorogallic acid (HGaCl4) in diethyl ether is performed. To improve the overall ETAAS performance, the graphite tubes were pre-treated with iridium(III) and tungsten(IV). A mixed chemical modifier containing Ni(II), Sr(II) and citric acid was also used. The characteristic mass (m0) is 301 +/- 47 pg and the detection limit (3sB) is 2.4 microg g(-1). The classic UV-Vis spectrophotometric procedure using curcumin was also extended to the determination of boron in GaAs. By masking Ga(III) with EDTA and a preliminary extraction of boron with 2-ethyl-hexane 1,3-diol, performed on a semi-micro scale, a detection limit of 0.6 microg g(-1) was achieved. Both methods were applied to the analysis of two Si-doped GaAs samples which were suspected of being boron-contaminated. Results are compared with those obtained by direct analysis of the decomposed sample solution using the inductively coupled plasma atomic emission spectrometry (ICP-AES).  相似文献   

18.
An on-line flow injection (FI) preconcentration-electrothermal atomic absorption spectrometry (ETAAS) method is developed for trace determination of chromium in drinking water samples by sorption on a conical minicolumn packed with activated carbon (AC) at pH 5.0. The chromium was removed from the minicolumn with 1.0% (v/v) nitric acid. An enrichment factor (EF) of 35-fold for a sample volume of 10 ml was obtained. The detection limit (DL) value for the preconcentration method proposed was 3.0 ng l−1. The precision for 10 replicate determinations at the 0.5 μg l−1 Cr level was 4.0% relative standard deviation (R.S.D.), calculate with the peak heights obtained. The calibration graph using the preconcentration system for chromium was linear with a correlation coefficient of 0.9992 at levels near the detection limits up to at least 50 μg l−1. The method was successfully applied to the determination of Cr(III) and Cr(VI) in drinking water samples.  相似文献   

19.
A resin-phase extraction method has been optimized for the trace determination of tin(II) by ETAAS. Tin(II) was extracted on a finely divided anion exchange resin as the complex with ammonium pyrrolidinedithiocarbamate (APDC). The resin was collected on a membrane filter and then dispersed in 1.00 ml of 1 mol l(-1) nitric acid containing 100 microg of Pd(II) and 60 microg of Ni(II). The resulting resin suspension was subjected to GFAAS. The proposed method was applied to the determination of tin(II) in hydrochloric acid.  相似文献   

20.
Tang AN  Ding GS  Yan XP 《Talanta》2005,67(5):942-946
Cloud point extraction was applied as a preconcentration step for electrothermal atomic absorption spectrometry (ETAAS) determination of As(III) in aqueous solutions. After complexation with ammonium pyrrolidinedithiocarbamate, the analyte was quantitatively extracted to the surfactant-rich phase in the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) after centrifugation. 0.1 mol L−1 HNO3 in methanol was added to the surfactant-rich phase before ETAAS determination. The precision (R.S.D.) for 11 replicate determinations of 5.0 μg L−1 of As(III) was 3.0%. The concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for ETAAS determination and in the initial solution, was 36 for As(III). The linear concentration range was from 0.1 to 20 μg L−1. The developed method was applied to the determination of As(III) in lake water and river water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏